Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Space Telescope Digicon

The Digicon, chosen by NASA as the detector for the High Resolution Spectrograph (HRS) and the Faint Object Spectrograph (FOS) is a 512 parallel output channel vacuum photodetector. There are two HRS Digicons with spectral sensitivity ranges from 1050 A to 1800 A and 1150 A to 3000 A respectively, and two FOS Digicons, which have spectral ranges extending to 7000 A. The significant requirements for these devices are 0.01 counts per second background count rate per diode, state-of-the-art Digicon pulse height resolution (typical 15%) and a high degree of imaging precision and stability. The results of a manufacturing and test program to develop the Digicons coupled with extensive prior work has shown that these requirements can be met. The Digicon because of its inherent ruggedness is particularly well suited to space applications.

Alting-Mees, H. R.↗

Pre-Launch Performance Trending of Joint Polar Satellite System (JPSS) Advanced Technology Microwave Sounder (ATMS)

The Advanced Technology Microwave Sounder (ATMS) microwave radiometer instrument is utilized on-board NOAA’s Joint Polar Satellite System (JPSS) fleet of spacecraft to perform temperature and water vapor soundings of Earth’s atmosphere. Consisting of 22 channels over a frequency range from 22 to 183 GHz, ATMS provides high-impact observations for numerical weather prediction (NWP) models. A general description of the ATMS instrument is discussed in [1]. There are five ATMS flight units in the polar-orbiting JPSS program; three are currently on-orbit and two are pending launch. The first ATMS was flown on the Suomi National Polar-orbiting Partnership (SNPP) satellite, launched in 2011. The second ATMS was launched on the NOAA-20 (previously JPSS-1) satellite in 2017. The third ATMS was launched on the NOAA-21 (previously JPSS-2) satellite in 2022. The SNPP and NOAA-20 ATMS units are operational. The NOAA-21 ATMS unit is completing on-orbit commissioning and checkout, having achieved provisional maturity status in December 2022 with validated maturity expected in May 2023 [2]. The fourth and fifth ATMS units are planned for the JPSS-3 (launch ~2028) and JPSS-4 (launch ~2032) satellites [3]. This paper will focus on trending performance characteristics of each JPSS ATMS build from the pre-launch activities. Pre-launch trending of some parameters have been previously published up to the JPSS-3 mission [4][5]. This paper differs from and expands the scope of the prior work as it will include all five of the JPSS ATMS builds. The entire suite of JPSS ATMS units have completed their pre-ship instrument-level I&T and verification activities. These activities include a radiometric performance characterization of each instrument. In addition to comparing the performance across builds, the performance will also be compared to requirements and specifications where applicable. The on-orbit performance of the launched units will be excluded from the scope of this paper in order to focus on evaluations that are common across all builds. The post-launch performance of SNPP ATMS is detailed in [1][6][7][8]. The post-launch performance of NOAA-20 ATMS is detailed in [6][8][9]. The pre-launch characterization of the ATMS occurs at both subassembly-level and instrument-level testing. The antenna subsystem is tested at Northrop Grumman’s Compact Antenna Test Range (CATR) in Azusa, CA [9]. This testing characterizes the antenna pattern and the pointing performance of the scan drive mechanism and antenna subsystem. Trended parameters from this evaluation will include beam pointing accuracy, beamwidth, and beam efficiency. These parameters are captured in each instrument’s Calibration Data Book [10]. Instrument-level radiometric performance evaluation is primarily done during thermal vacuum (TVAC) calibration testing at Northrop Grumman’s Azusa, CA facility [9]. A general description of the calibration activities is presented in [1][9]. The testing involves inferring a scene target brightness temperature (TB) and comparing it to the actual scene TB while the instrument is at flight-like temperature and pressure environmental conditions. Trended parameters from this activity will include Noise Equivalent Delta Temperature (NEDT), nonlinearity, radiometric accuracy, gain stability, striping, and inter-channel noise correlation. The trending evaluation will allow for a direct comparison of the ATMS performance across builds. The paper will highlight observed performance improvements.

Edward J Kim↗

Effects of Initial Powder Size on the Mechanical Properties and Microstructure of As-Extruded GRCop-84

GRCop-84 was developed to meet the mechanical and thermal property requirements for advanced regeneratively cooled rocket engine main combustion chamber liners. It is a ternary Cu- Cr-Nb alloy having approximately 8 at% Cr and 4 at% Nb. The chromium and niobium constituents combine to form 14 vol% Cr2Nb, the strengthening phase. The alloy is made by producing GRCop-84 powder through gas atomization and consolidating the powder using extrusion, hot isostatic pressing (HIP) or vacuum plasma spraying (VPS). GRCop-84 has been selected by Rocketdyne, Ratt & Wlutney and Aerojet for use in their next generation of rocket engines. GRCop-84 demonstrates favorable mechanical and thermal properties at elevated temperatures. Compared to NARloy-Z, the currently used inaterial in the Space Shuttle, GRCop-84 has approximately twice the yield strength, 10-1000 times the creep life, and 1.5-2.5 times the low cycle fatigue life. The thermal expansion of GRCop-84 is 7515% less than NARloy-Z which minimizes thermally induced stresses. The thermal conductivity of the two alloys is comparable at low temperature but NARloy-Z has a 20-50 W/mK thermal conductivity advantage at typical rocket engine hot wall temperatures. GRCop-84 is also much more microstructurally stable than NARloy-Z which translates into better long term stability of mechanical properties. Previous research into metal alloys fabricated by means of powder metallurgy (PM), has demonstrated that initial powder size can affect the microstructural development and mechanical properties of such materials. Grain size, strength, ductility, size of second phases, etc., have all been shown to vary with starting powder size in PM-alloys. This work focuses on characterizing the effect of varying starting powder size on the microstructural evolution and mechanical properties of as- extruded GRCop-84. Tensile tests and constant load creep tests were performed on extrusions of four powder meshes: +140 mesh (great3er than l05 micron powder size), -140 mesh (less than or equal to 105 microns), -140 plus or minus 270 (53 - 105 microns), and - 270 mesh (less than or equal to 53 microns). Samples were tested in tension at room temperature and at 500 C (932 F). Creep tests were performed under vacuum at 500 C using a stress of 111 MPa (16.1 ksi). The fracture surfaces of selected samples from both tests were studied using a Scanning Electron Microscope (SEM). The as-extruded materials were also studied, using both optical microscopy and SEM analysis, to characterize changes within the microstructure.

Okoro, Chika L.↗

Status and performance of the GlueX DIRC

In support of the future physics program at Ce+BAF, we propose a prototype positron target. The prototype target consists of a tungsten disk mounted on a water-cooled copper support structure to enhance heat removal. The primary goals of this work are to benchmark CFD simulations, ensure vacuum integrity at the 10^-6 Pa level, achieve stable target rotation up to 10 Hz, and implement efficient water-based cooling for sustained high-power operation. To manage the thermal load, the target is designed to rotate, allowing the deposited heat to spread over a larger region, and thereby reducing localized thermal stress while maintaining the maximum temperature below 1000 K. To experimentally evaluate the thermal performance and structural stability of the target, we plan to conduct high-power laser heating tests at Laser Lab 5, LERF Building, JLab. These tests will serve as a stepping-stone for the positron production target at CEBAF.

Stevens, J.R. [College of William and Mary, Willia↗

Concerning the production of free radicals in proteins by ultraviolet light.

The response to UV light of several solid proteins and model compounds has been studied in vacuum and at low temperature, using electron paramagnetic resonance techniques. The results indicate that the details of amino acid composition and sequence, and the tertiary structure of a protein are important in determining both the rate of, and the mechanism for, the production of free radicals, and in determining the conditions under which sulfur-type radicals can be produced. The results presented are related to enzyme inactivation and to the UV stability of proteins generally.

Androes, G. M.↗

Space Environment Stability and Physical Properties of New Materials for Space Power and Commercial Applications

Useful and informative results were obtained on virtually all materials investigated. For example, the stability of ITO-based arc-proof transparent coatings was greatly improved by substitution of silicon oxide for magnesium fluoride as a dopant. Research on 'air-doped' ITO films has yielded new insight into their conduction mechanism which will help in further development of these coatings. Some air-doped films were found to be extremely pressure sensitive. This work may lead to improved, low-cost gas sensors and vacuum gauges. Work on another promising transparent arc-proof coating (titanium oxide) was initiated in collaboration with industry. Graphite oxide-like materials were synthesized and tested for possible use in high energy-density batteries and other applications. We also started a high-priority project to find the cause of unexpected environmental damage to the exterior of the Hubble Space Telescope (HST) discovered on a recent Shuttle mission. Materials were characterized before and after exposure to soft x-rays and other threats in ground-based simulators.

Hambourger, Paul D.↗

Characteristics of Ultralow Aspect Ratio Toroidal Plasmas and Non-Solenoidal Startup and Edge Stability Studies at Near-Unity Aspect Ratio (Final Report)

This grant supported a long-term research and development program to explore the physics and technology of spherical tokamak (ST) plasma behavior at near-unity aspect ratio ( A ). The PEGASUS Toroidal Experiment is a university-scale ( R ) ~ 0.40 m, α ~ .35 m, I p ≤ 0.3 MA, B T ≤ 0.15 T) experiment that accesses A → 1, to provide large values of the normalized plasma current, I N = I p /α B T , or equivalently the toroidal field utilization factor I p / I TF . The research activities focused on: 1) developing the technique of Local Helicity Injection (LHI) as a viable means of initiating and growing an ST plasma without the use of a central solenoid; 2) exploring the equilibrium and stability properties of spherical tokamak plasmas at extremely low aspect ratio; and 3) obtaining new insights in the properties of the enhanced confinement H-mode regime at A ~ 1. The initial (Phase I) facility employed a unique high-stress central solenoid Ohmic for current drive and heating with simple magnet current waveforms. A subsequent major upgrade (Phase II) offered more flexible control of the plasma evolution along with a powerful LHI system for plasma initiation, heating and sustainment. The LHI technique consists of injection of high-density current streams into vacuum toroidal and vertical magnetic fields. These streams become unstable and support magnetic reconnection to allow the system to relax into a tokamak-like magnetic configuration. This program focused on: 1) development of electron current sources that provide sufficiently high injection currents in the challenging edge plasma region; 2) validation of theoretical limits to achievable I p arising from magnetic helicity and energy conservation plus absolute limits arising from relaxation to a minimal energy states; 3) tests of a power balance model to describe the evolution of the plasma current I p (t); and 4) study of magnetic fluctuations and their role in the I p evolution. This culminated in the production of toroidal currents of I p ≥ 0.2 MA with only ~8 kA of injected current. Operation with Ohmic induction alone in Phase I created plasmas with soft limits on the achievable I p and field utilization ( I p / I TF ~ 1) due to the onset of large low-order (2/1 or 3/2) internal resonant tearing modes. With the expanded capabilities in Phase II operation, methods employed to mitigate those modes and achieve I p / I TF > 1 were: 1) I TF ramp-downs; 2) non-solenoidal startup via LHI; and 3) extremely low I TF Ohmic operations assisted by LHI current injector pre-ionization. Extensive use of LHI-driven startup and drive for non-solenoidal operation produced favorable current profiles to stably operate tokamak plasmas with unprecedentedly high I N = I p / aB T ~ 15 and I p / I TF > 2. With strong reconnection-driven anomalous ion heating, this in turn provided access to tokamak plasmas with B t up to 100%, a world record 2 times higher than that previously achieved in advanced or spherical tokamaks. This high B t regime had a large fraction (~50%) of the plasma volume in a region of an absolute minimum- B configuration. The MHD stability limit in this regime was the ideal external kink mode without a stabilizing wall. These results provided the first demonstration of access to tokamak plasmas with very high B t , high i N , high elongation κ, and low internal inductance ℓ i , and as such served as a proof-ofprinciple for access to this long-sought ST regime. The naturally low B T needed for stability at A ≤ 1.2 reduces the L-H mode power threshold, P LH , so that H-mode plasmas were achieved with Ohmic heating alone. The power threshold for the transition to the H-mode regime was found to be 10× the accepted values from the ITER international scaling, confirming initial trends indicated by experiments on MAST and NSTX, and suggesting that the physics behind this transition is not yet fully understood. The density dependence of the transition and the observed insensitivity to whether the plasma is bounded by a limiter or magnetic divertor are consistent with the recent FM 3 model. Multiple unstable toroidal magnetic modes were measured during ELM (Edge Localized Mode) crashes, with generally lower toroidal mode numbers than seen at higher A , which was attributed to the larger peeling mode instability drive at low A . First-ever edge current profile measurements through an ELM crash showed current-carrying filaments were generated, as seen in ELM simulations and in electromagnetic blob transport theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of extreme ultraviolet spectroscopy on a sheared-flow-stabilized Z pinch

A diagnostic for extreme ultraviolet spectroscopy was fielded on the sheared-flow-stabilized (SFS) fusion Z-pinch experiment (FuZE-Q) for the first time. The spectrometer collected time-gated plasma emission spectra in the 5–40 nm wavelength (30–250 eV) range for impurity identification, radiative power studies, and for plasma temperature and density measurements. The unique implementation of the diagnostic included fast (10 ns risetime) pulsed high voltage electronics and a multi-stage differential pumping system that allowed the vacuum-coupled spectrometer to collect three independently timed spectra per FuZE-Q shot while also protecting sensitive internal components. Analysis of line emission identifies oxygen (N-, C-, B-, Be-, Li-, and He-like O), peaking in intensity shortly after maximum current (>500 kA). This work provides a foundation for future high energy spectroscopy experiments on SFS Z-pinch devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Silicon crystal as a low work function collector

A test vehicle with a low work function collector which can be incorporated in a thermionic converter was constructed from standard vacuum components including an ultrahigh vacuum ion pump. The collector assembly was fabricated by diffusion bonding a (100) oriented silicon single crystal to a molybdenum block. The silicon surface was treated with cesium and oxygen to produce an NEA-type condition and the results were tested by photoemission and work function measurements. An n-type silicon collector was successfully activated to a work function of 1.0 eV, which was verified by photoemission spectral yield measurements. The stability test of an activated surface at elevated temperatures was conducted in the range from room temperature to 619 K, which was slightly lower than the designed collector temperature of 700 K. The work function measurements clearly demonstrated that the behavior of cesium replenishment on the activated Si surface was similar in nature to that of a metallic surface; that is, the loss of cesium by thermal desorption could be compensated by maintaining an adequate vapor pressure of cesium.

Chang, K. H.↗

Measurement and Control of Oxygen Partial Pressure in an Electrostatic Levitator

Recently the NASA Marshall Space Flight Center electrostatic levitation (ESL) laboratory has been upgraded to include an oxygen control system. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled, at elevated temperatures, theoretically in the range from 10(exp -36) to 10(exp 0) bar. The role of active surface agents in liquid metals is fairly well known; however, published surface tension data typically has large scatter, which has been hypothesized to be caused by the presence of oxygen. The surface tension of metals is affected by even a small amount of adsorption of oxygen. It has even been shown that oxygen partial pressures may need to be as low as 10(exp -24) bar to avoid oxidation. While electrostatic levitation is done under high vacuum, oxide films or dissolved oxygen may have significant effects on materials properties, such as surface tension and viscosity. Therefore, the ability to measure and control the oxygen partial pressure within the chamber is highly desirable. The oxygen control system installed at MSFC contains a potentiometric sensor, which measures the oxygen partial pressure, and an oxygen ion pump. In the pump, a pulse-width modulated electric current is applied to yttrium-stabilized zirconia, resulting in oxygen transfer into or out of the system. Also part of the system is a control unit, which consists of temperature controllers for the sensor and pump, PID-based current loop for the ion pump, and a control algorithm. This system can be used to study the effects of oxygen on the thermophysical properties of metals, ceramics, glasses, and alloys. It can also be used to provide more accurate measurements by processing the samples at very low oxygen partial pressures. The oxygen control system will be explained in more detail and an overview of its use and limitations in an electrostatic levitator will be described. Some preliminary measurements have been made, and the results to date will be provided.

SanSoucie, Michael P.↗

Engineering Polymer Blends for Impact Damage Mitigation

Structures containing polymers such as DuPont's Surlyn® 8940, demonstrate puncture healing when impacted by a 9 millimeter projectile traveling from speeds near 300 meters per second (1,100 feet per second) to hypervelocity impacts in the micrometeoroid velocity range of 5 kilometers per second (16,000 feet per second). Surlyn® 8940 puncture heals over a temperature range of minus 30 degrees Centigrade to plus 70 degrees Centigrade and shows potential for use in pressurized vessels subject to impact damage. However, such polymers are difficult to process and limited in applicability due to their low thermal stability, poor chemical resistance and overall poor mechanical properties. In this work, several puncture healing engineered melt formulations were developed. Moldings of melt blend formulations were impacted with a 5.56 millimeter projectile with a nominal velocity of 945 meters per second (3,100 feet per second) at about 25 degrees Centigrade, 50 degrees Centigrade and 100 degrees Centigrade, depending upon the specific blend being investigated. Self-healing tendencies were determined using surface vacuum pressure tests and tensile tests after penetration using tensile dog-bone specimens (ASTM D 638-10). For the characterization of tensile properties both pristine and impacted specimens were tested to obtain tensile modulus, yield stress and tensile strength, where possible. Experimental results demonstrate a range of new puncture healing blends which mitigate damage in the ballistic velocity regime.

Gordon, Keith L.↗

Thermal Vacuum Test of GLAS Propylene Loop Heat Pipe Development Model

This paper presents viewgraphs on Thermal Vacuum Tests of the GLAS (Geoscience Laser Altimeter System) Propylene Loop Heat Pipe Development Model. The topics include: 1) Flight LHP System (Laser); 2) Test Design and Objectives; 3) DM (Development Model) LHP (Loop Heat Pipe) Test Design; 4) Starter Heater and Coupling Blocks; 5) CC Control Heaters and PRT; 6) Heater Plates (Shown in Reflux Mode); 7) Startup Tests; 8) CC Control Heater Power Tests for CC Temperature Control; and 9) Control Temperature Stability.

Baker, Charles↗

Effects of Oxygen Partial Pressure on the Surface Tension of Liquid Nickel

The NASA Marshall Space Flight Center's electrostatic levitation (ESL) laboratory has been recently upgraded with an oxygen partial pressure controller. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled, theoretically in the range from 10‐36 to 100 bar. The oxygen control system installed in the ESL laboratory's main chamber consists of an oxygen sensor, oxygen pump, and a control unit. The sensor is a potentiometric device that determines the difference in oxygen activity in two gas compartments (inside the chamber and the air outside of the chamber) separated by an electrolyte, which is yttria‐stabilized zirconia. The pump utilizes coulometric titration to either add or remove oxygen. The system is controlled by a desktop control unit, which can also be accessed via a computer. The controller performs temperature control for the sensor and pump, PID-based current loop, and a control algorithm. Oxygen partial pressure has been shown to play a significant role in the surface tension of liquid metals. Oxide films or dissolved oxygen may lead to significant changes in surface tension. The effects of oxygen partial pressure on the surface tension of undercooled liquid nickel will be analyzed, and the results will be presented. The surface tension will be measured at several different oxygen partial pressures while the sample is undercooled. Surface tension will be measured using the oscillating drop method. While undercooled, each sample will be oscillated several times consecutively to investigate how the surface tension behaves with time while at a particular oxygen partial pressure.

SanSoucie, Michael P.↗

Moisture interaction and stability of ZOT (Zinc Orthotitanate) thermal control spacecraft coating

Two of the many performance requirements of the zinc orthotitanate (ZOT) ceramic thermal control paint covering parts of the Jupiter-bound Galileo spacecraft are that it be sufficiently electrically conductive so as to prevent electrostatic discharge (ESD) damage to onboard electronics and that it adhere to and protect the substrate from corrosion in terrestrial environments. The bulk electrical resistivity of ZOT on an aluminum substrate was measured over the ranges 22 C to 90 C and 0 percent RH to 100 percent RH, and also in soft (10 (minus 2) Torr) and hard (10 (minus 7) Torr) vacuums. No significant temperature dependence was evident, but measured resistivity values ranged over 9 orders of magnitude: 10 to the 5th power ohm-cm at 100 percent RH greater than 10 to the 12th power ohm-cm in a hard vacuum. The latter value violates the ESD criterion for a typical 0.019 cm thick coating. The corrosion study involved exposing typical ZOT substrate combinations to two moisture environments - 30 C/85 percent RH and 85 C/85 percent RH - for 2000 hours, during which time the samples were periodically removed for front-to-back electrical resistance and scratch/peel test measurements. It was determined that the ZOT/Al and ZOT/Mg systems are stable (no ZOT delamination), although some corrosion (oxide formation) and resistivity increases observed among the ZOT/Mg samples warrant that exposure of some parts to humid environments be minimized.

Mon, Gordon R.↗

Brane-jet instabilities

With one exception, all known non-supersymmetric AdS 4 and AdS 5 vacua of gauged maximal supergravities that descend from string and M theory have been shown to have modes with mass below the BF bound. The remaining non-supersymmetric AdS solution is perturbatively stable within gauged maximal supergravity, and hence appears to contradict recent conjectures about the AdS stability based on the weak gravity conjecture. We show that this solution is actually unstable by exhibiting a new decay channel, which is only visible when the solution is uplifted to eleven dimensions. In particular, M2 brane probes at generic locations inside the internal manifold are attracted to the Poincaré horizon, only to be expelled as “brane jets” along certain directions of the internal manifold. Such instabilities can arise in any non-supersymmetric AdS vacuum in any dimension. When a brane-jet instability is present, the force that expels the branes is the same as the force felt by a probe brane whose mass is less than its charge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization data of an (AlFeNiTiVZr) 1-x Cr x multi-principal element alloy continuous composition spread library

The data provided in this article is related to the research article entitled “Phase stabilization and oxidation of a continuous composition spread multi-principal element (AlFeNiTiVZr) 1-x Cr x alloy”. This data article describes the high-throughput synthesis and characterization processes of an (AlFeNiTiVZr) 1-x Cr x alloy system. Continuous composition spread (CCS) thin-film libraries were synthesized by co-depositing an AlFeNiTiVZr metal alloy target and Cr target via magnetron sputtering. Post-processing was performed on the sample libraries with a vacuum anneal at 873 K and an air anneal at 873 K. Compositional data was determined via WDS in order to verify parameters provided by an in-house sputter model. Crystallographic data was captured via synchrotron diffraction and diffractograms were compared as a function of the change in Cr concentration. These measurements were taken in order to observe phase behavior after oxidation throughout the composition library. Furthermore, vibrational spectrographic data is provided of the oxidized library to show surface speciation along the composition gradient of the alloy system. The structural and oxidative behavior of the (AlFeNiTiVZr) 1-x Cr x alloy can be analysed using the data provided in this article. Additionally, this characterization dataset can be utilized in machine learning algorithms for determining important features and parameters for future hypothesis generation of functional multi-principal element alloys (MPEAs).

36 MATERIALS SCIENCE↗

Spectroradiometric calibration techniques in the far ultraviolet - A stable emission source for the Lyman bands of molecular hydrogen

The problems associated with making accurate spectroradiometric measurements in the far UV region are sketched briefly. The equipment and methods that were developed for providing absolute sensitivity calibration of an Apollo 17 far UV spectrometer are described. The absolute reference standards were photoelectric diodes calibrated at the National Bureau of Standards. A complete vacuum optical facility, which included a premonochromator and stable UV light sources, was developed to calibrate the Apollo 17 instrument, and it has been used for a number of other tasks. Absolute radiometric calibrations between about 1200 and 1700 A were performed with an absolute accuracy of + or - 10%. The light source, which was designed to provide a very stable light output, is a low-pressure molecular hydrogen lamp in which the pressure is stabilized by thermal control of uranium hydride powder.-

Fastie, W. G.↗

Coprocessing Biomass Fast Pyrolysis and Catalytic Fast Pyrolysis Oils with Vacuum Gas Oil in Refinery Hydroprocessing

Fast pyrolysis and catalytic fast pyrolysis (CFP) have been considered to be promising approaches for converting lignocellulosic biomass into liquid bio-oils followed by upgrading to produce fuel-range hydrocarbon products. Co-processing fast pyrolysis and CFP bio-oils with petroleum feedstocks leverages the existing petroleum refining infrastructure, which reduces Capex for the overall conversion technologies for biomass to fuel and enables fast adoption of the technologies and biofuels. Here, we reported the co-processing of different woody fast pyrolysis and CFP bio-oils with petroleum vacuum gas oil (VGO) at 5-25% bio-oil blending levels over a NiMo sulfide catalyst for mild hydrocracking. The catalyst activities over ~300 hours time on stream, the product yield and properties, and the biogenic carbon content in products are provided. Co-processing of the raw fast pyrolysis bio-oil in our configuration was not successful because the instability of the bio-oil resulted in reactor plugging and bio-oil stabilization by hydrogenation enabled their stable co-processing with VGO, whereas the CFP bio-oil can be co-processed without pretreatment. Simultaneous hydrodesulfurization, hydrodeoxygenation, and hydrocracking reactions occurred during co-processing and no obvious decrease in hydrodesulfurization and hydrocracking conversion of VGO was observed, suggesting the minimal impact of co-processed bio-oils on the reaction of VGO and also the simultaneous conversion of bio-oil and VGO to produce fuel products with much-reduced S and O content. Biogenic carbon content in co-processed products calculated by yield mass balance, together with results from isotopic measurements, indicates high biogenic carbon incorporation into liquid hydrocarbon products. In conclusion, higher biogenic carbon incorporation into fuel products was observed when co-processing CFP bio-oils than the fast pyrolysis bio-oils and over 90% of carbon in CFP bio-oil was incorporated into liquid hydrocarbon products.

09 BIOMASS FUELS↗