Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “units”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

"The Waters of Meridiani" - Further Support for a Fluvial Interpretation of the Ridged, Layered Units

A relatively unknown terrestrial fluvial environment, the mesoscale megafan, provides analogs for various Martian landscapes, including the etched unit (etched unit, Unite E of Arvidson et al., 2003; ridge-forming unit R of Edgett, 2005) of the Sinus Meridiani region on Mars. A global survey of Earth shows that megafans are very large partial cones of dominantly fluvial sediment with radii on the order of hundreds of km, and very low slopes. Responsible fluvial processes are sufficiently different from those of classical arid alluvial fans and deltas that it is useful to class megafans as separate features. The megafan model calls into question two commonly held ideas. 1. Earth examples prove that topographic basins per se are unnecessary for the accumulation of large sedimentary bodies. 2. River channels are by no means restricted to valleys (Meridiani sediments are termed a "valley-ed volume" of Edgett). These perspectives reveal unexpected parallels with features at Meridiani-several channel-like features that are widespread, mostly as ridges inverted by eolian erosion; channel networks covering thousands of sq km, especially on intercrater plains; and regional relationships of sediment bodies situated immediately downstream of highland masses. These all suggest that fluvial explanations are at least part of the Meridiani story.

Wilkinson, Justin↗

Fluvial Channel Networks as Analogs for the Ridge-Forming Unit, Sinus Meridiani, Mars

Fluvial models have been generally discounted as analogs for the younger layered rock units of Sinus Meridiani. A fluvial model based on the large fluvial fan provides a possibly close analog for various features of the sinuous ridges of the etched, ridge-forming unit (RFU) in particular. The close spacing of the RFU ridges, their apparently chaotic orientations, and their organization in dense networks all appear unlike classical stream channel patterns. However, drainage patterns on large fluvial fans low-angle, fluvial aggradational features, 100s of km long, documented worldwide by us provide parallels. Some large fan characteristics resemble those of classical floodplains, but many differences have been demonstrated. One major distinction relevant to the RFU is that channel landscapes of large fans can dominate large areas (1.2 million km2 in one S. American study area). We compare channel morphologies on large fans in the southern Sahara Desert with ridge patterns in Sinus Meridiani (fig 1). Stream channels are the dominant landform on large terrestrial fans: they may equate to the ubiquitous, sinuous, elongated ridges of the RFU that cover areas region wide. Networks of convergent/divergent and crossing channels may equate to similar features in the ridge networks. Downslope divergence is absent in channels of terrestrial upland erosional landscapes (fig. 1, left), whereas it is common to both large fans (fig. 1, center) and RFU ridge patterns (fig 1, right downslope defined as the regional NW slope of Sinus Meridiani). RFU ridge orientation, judged from those areas apparently devoid of impact crater control, is broadly parallel with the regional slope (arrow, fig. 1, right), as is mean orientation of major channels on large fans (arrow, fig. 1, center). High densities per unit area characterize fan channels and martian ridges reaching an order of magnitude higher than those in uplands just upstream of the terrestrial study areas fig. 1. In concert with several other regional features, these morphological similarities argue for the RFU as a possibly fluvial unit.

Wilkinson, M. J.↗

Regional Warming from Aerosol Removal over the United States: Results from a Transient 2010-2050 Climate Simulation

We use a general circulation model (NASA Goddard Institute for Space Studies GCM 3) to investigate the regional climate response to removal of aerosols over the United States. We perform a pair of transient 2010e2050 climate simulations following a scenario of increasing greenhouse gas concentrations, with and without aerosols over the United States and with present-day aerosols elsewhere. We find that removing U.S. aerosol significantly enhances the warming from greenhouse gases in a spatial pattern that strongly correlates with that of the aerosol. Warming is nearly negligible outside the United States, but annual mean surface temperatures increase by 0.4e0.6 K in the eastern United States. Temperatures during summer heat waves in the Northeast rise by as much as 1e2 K due to aerosol removal, driven in part by positive feedbacks involving soil moisture and low cloud cover. Reducing U.S. aerosol sources to achieve air quality objectives could thus have significant unintended regional warming consequences.

Mickley, L. J.↗

Unit Testing for the Application Control Language (ACL) Software

In the software development process, code needs to be tested before it can be packaged for release in order to make sure the program actually does what it says is supposed to happen as well as to check how the program deals with errors and edge cases (such as negative or very large numbers). One of the major parts of the testing process is unit testing, where you test specific units of the code to make sure each individual part of the code works. This project is about unit testing many different components of the ACL software and fixing any errors encountered. To do this, mocks of other objects need to be created and every line of code needs to be exercised to make sure every case is accounted for. Mocks are important to make because it gives direct control of the environment the unit lives in instead of attempting to work with the entire program. This makes it easier to achieve the second goal of exercising every line of code.

Computer Programming Integrity↗

Evaluation of NASA's MERRA Precipitation Product in Reproducing the Observed Trend and Distribution of Extreme Precipitation Events in the United States

This study evaluates the performance of NASA's Modern-Era Retrospective Analysis for Research and Applications (MERRA) precipitation product in reproducing the trend and distribution of extreme precipitation events. Utilizing the extreme value theory, time-invariant and time-variant extreme value distributions are developed to model the trends and changes in the patterns of extreme precipitation events over the contiguous United States during 1979-2010. The Climate Prediction Center (CPC) U.S.Unified gridded observation data are used as the observational dataset. The CPC analysis shows that the eastern and western parts of the United States are experiencing positive and negative trends in annual maxima, respectively. The continental-scale patterns of change found in MERRA seem to reasonably mirror the observed patterns of change found in CPC. This is not previously expected, given the difficulty in constraining precipitation in reanalysis products. MERRA tends to overestimate the frequency at which the 99th percentile of precipitation is exceeded because this threshold tends to be lower in MERRA, making it easier to be exceeded. This feature is dominant during the summer months. MERRA tends to reproduce spatial patterns of the scale and location parameters of the generalized extreme value and generalized Pareto distributions. However, MERRA underestimates these parameters, particularly over the Gulf Coast states, leading to lower magnitudes in extreme precipitation events. Two issues in MERRA are identified: 1) MERRA shows a spurious negative trend in Nebraska and Kansas, which is most likely related to the changes in the satellite observing system over time that has apparently affected the water cycle in the central United States, and 2) the patterns of positive trend over the Gulf Coast states and along the East Coast seem to be correlated with the tropical cyclones in these regions. The analysis of the trends in the seasonal precipitation extremes indicates that the hurricane and winter seasons are contributing the most to these trend patterns in the southeastern United States. In addition, the increasing annual trend simulated by MERRA in the Gulf Coast region is due to an incorrect trend in winter precipitation extremes.

MERRA↗

Mechanisms Associated with Daytime and Nighttime Heat Waves over the United States

Heat waves are extreme climate events that have the potential to cause immense stress on human health, agriculture and energy systems, so understanding the processes leading to their onset is crucial. There is no single accepted definition for heat waves, but they are generally described as a sustained amount of time where temperature exceeds a local threshold. Multiple different temperature variables are potentially relevant, as high values of daily maximum (T(max)) and minimum (T(min)) temperatures can both be detrimental to human health. Previous studies have concluded that the frequency of global heat waves has increased over recent decades, with greater increases in T(min)- than T(max)-heat waves in several regions. In this study, we focus explicitly on the different mechanisms associated with heatwaves manifest during daytime versus nighttime hours over the United States. Heat waves are examined using the National Aeronautics and Space Administration (NASA) Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2). A daytime (nighttime) heat wave is defined as average daytime (nighttime) temperature exceeding its calendar day 90th percentile for at least 3 days. Over 1980-2018, the number of heat wave days per summer has increased over much of the United States. Trends are stronger for nighttime versus daytime heat wave frequency over the Northeast, Midwest and Southwest United States. Local and remote processes linked with daytime and nighttime heat waves are identified through composite analysis of clouds, precipitation, soil moisture, and fluxes of heat and moisture. Finally, we characterize the large-scale atmospheric circulation associated with daytime and nighttime heat waves over different regions of the United States.

Thomas, N.↗

Glen Torridon Mineralogy and the Sedimentary History of the Clay Mineral Bearing Unit

Clay minerals are common in ancient terrains on Mars and their presence at the surface alludes to aqueous processes in the Noachian to Early Hesperian (>3.5 Ga). Gale crater was selected as Curiosity’s landing site largely because of the identification of clay mineral rich strata from orbit. On Earth, the types of clay minerals (i.e., smectites) identified in Gale crater are typically juvenile weathering products that ultimately record the interaction between primary igneous minerals with the hydrosphere, atmosphere, and biosphere. Trioctahedral and dioctahedral smectite were identified by Curiosity in units stratigraphically below the Clay Mineral-Bearing Unit (CBU) identified from orbit. Compositional and sedimentological data suggest the smectite formed via authigenesis in a lake environment and may have been altered during early diagenesis. The CBU is stratigraphically equivalent to a hematite-rich unit to the north and stratigraphically underlies sulfate-rich units to the south, suggesting a dynamic environment and evolving history of water in the ancient Gale crater lake. Targeting these clay mineral rich areas on Mars with rover missions provides an opportunity to explore the aqueous and sedimentary history of the planet.

Thorpe, M. T.↗

Demonstration of A Long Duration Crop in the Advanced Plant Habitat Engineering Demonstration Unit: Key Factors to Consider Prior to Testing and Lessons Learned

The Advanced Plant Habitat (APH) is a fully enclosed, closed-loop, plant growth facility currently deployed on the International Space Station (ISS). It is equipped with complete environmental control (i.e.spectral qualityandlight intensity, temperature, relative humidity, and CO2),root module which containsa growth substrate(typically arcillite) and a porous tube based automated water delivery system. Two APH units, one ground unitidentical to the on-orbit versionand an Engineering Development Unit (EDU; a high fidelity test version), currently reside at Kennedy Space Center. Prior to conducting tests on-orbit, these APH ground units areutilized to conductbothScience Verification Tests(SVT; primarilyinthe EDU) and Experiment Verification Tests (EVT; primarily in the Ground Unit). In February 2020, a 122 day experiment was concluded in the APH EDU where four 'Numex Española Improved' pepper plants (Capsicum annuum) were successfully grown from seed to harvestyieldingover 50 fruit, demonstrating the capabilityand versatilityof this APH EDU system to support plant growth for long life cycle flowering/fruiting plants.

L. E. Spencer↗

Metabolic Vessel for Impedance Spectroscopy and Electrochemistry (MVISE): The Ground Mapping Unit for the Lunar Explorer Instrument for Space Biology Applications (LEIA)​

The BioSensor payload on the upcoming LEIA platform aboard a CLPS lander will carry yeast to the moon to study response to radiation and lunar gravity. The LEIA BioSensor is designed to monitor metabolic activity using absorbance in conjunction with alamarBlue for measuring colorimetric changes as proxy measurement for redox potential. The science data returned from small spacecraft mission modules like LEIA is limited as it relies solely on optical measurements, necessitating a corresponding ground mapping unit that is equipped with multiple electrochemical sensors for accurate mapping of the optical data and operates fully automatically. This technology development work discusses the extensive design and optimization efforts put into the ground mapping unit, MVISE. MVISE is a custom designed, 3D-printed vessel with an agitation system, with six different electrochemical sensor probes, and ports for sample collection and a pressure release valve. The sensors provide real-time data, with dry absorbance measurements aligning with LEIA flight hardware and wet measurements demonstrating invasive sensor design enabling a comparison between the two setups. The 3D printer resin was tested for mechanical robustness, biocompatibility, and resistance to autoclave sterilization. The inner walls were coated with food-grade epoxy, ensuring a smooth finish to prevent microbial lodging and dye staining. The MVISE has successfully passed a week-long leak test and is now undergoing active biology tests. The MVISE prototype will be prepared for radiation tests, with three identical units being tested for varying radiation levels and culture compositions at the NASA Space Radiation Laboratory in November 2024. The integrated sensor approach proposed in this work will enable the accurate mapping of the BioSentinel/LEIA optical flight data to six sensor parameters on the ground unit for better science data return and will enable the first effort to evaluate classical biochemical sensor measurements by comparing and contrasting their responses.

Chinmayee Govinda Raj↗

Development of 20 IEER Rooftop Units System Modeling and Building Energy Simulations

Based on detailed steady-state system and component modeling, we developed a rooftop unit system design, which is able to achieve IEER (Integrated Energy Efficiency Ratio) higher than 20. We modeled fin-&-tube and micro-channel heat exchangers using segment-to-segment approach, and use AHRI 10-coefficient compressor map to simulate compressor performance. The system modeling is based on a component-based modeling approach, which facilitates flexible simulation of complicated system configurations. Starting with a baseline system having IEER of 16.6, we extensively investigated numerous technical options, i.e. varying compressor sizes, heat exchanger fin densities, fin-&-tube or micro-channel heat exchanger, suction line heat exchanger, desiccant wheel, tandem compressor, variable-speed compressor, and condenser evaporative pre-cooling; and developed an innovative system configuration combining a tandem compression system with a variable-speed compression system. The combined system can achieve high IEER as well as process the outdoor ventilation air over an extensive range. We successfully evaluated the design concept for a 20-ton (70.4 kW) unit as well as a 10-ton (35.2 kW) unit. All the selected components are readily accessible on the market, and we validated the performance predictions against existing Rooftop Unit (RTU) products at the rating condition. This paper illustrates a potentially cost-effective high IEER RTU design. In addtion, we conducted extensive building energy simulations using EnergyPlus to predict seasonal energy saving potentials and peak power reductions using the High IEER RTU in sixteen US cities, in comparison to a RTU with a minimum efficiency.

Modeling↗

Heap/stack guard pages using a wakeup unit

A method and system for providing a memory access check on a processor including the steps of detecting accesses to a memory device including level-1 cache using a wakeup unit. The method includes invalidating level-1 cache ranges corresponding to a guard page, and configuring a plurality of wakeup address compare (WAC) registers to allow access to selected WAC registers. The method selects one of the plurality of WAC registers, and sets up a WAC register related to the guard page. The method configures the wakeup unit to interrupt on access of the selected WAC register. The method detects access of the memory device using the wakeup unit when a guard page is violated. The method generates an interrupt to the core using the wakeup unit, and determines the source of the interrupt. The method detects the activated WAC registers assigned to the violated guard page, and initiates a response.

97 MATHEMATICS AND COMPUTING↗

Chemical looping integration with a carbon dioxide gas purification unit

A chemical looping system that contains an oxidizer and a reducer is in fluid communication with a gas purification unit. The gas purification unit has at least one compressor, at least one dryer; and at least one distillation purification system; where the gas purification unit is operative to separate carbon dioxide from other contaminants present in the flue gas stream; and where the gas purification unit is operative to recycle the contaminants to the chemical looping system in the form of a vent gas that provides lift for reactants in the reducer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Graphics processing unit management system for computed tomography

A method and apparatus for managing operation of graphics processing units in a computer system. A processing thread in the computer system controls processing of a set of sinogram data by a graphics processing unit to form a set of graphics data. An output thread in the computer system controls writing of the set of graphics data to a storage system. The graphics processing unit is available to perform processing of another set of sonogram data while the set of graphics data is written to the storage system such that the increased availability of a plurality of graphics processing units is present.

97 MATHEMATICS AND COMPUTING↗

Experimental Design and Laboratory Characterization of a Medium- and High-Efficiency Rooftop Unit for use in Building Energy Simulations

Commercial rooftop units that incorporate variable speed components are quickly entering into the market place; however, the design and modeling tools that calculate the energy benefits of these units cannot properly estimate performance. This is due to two factors: 1) There are insufficient measured performance data of real systems that can be entered into these simulations, and 2) building energy simulators are unable to properly interpret performance data. Therefore, publicly available datasets designed to encompass the entire performance map coupled with control sequence information are needed as inputs for these modelling programs to accurately estimate energy savings and promote variable speed RTUs. As part of the Verification and Uncertainty Characterization for Energy Simulation milestone funded by the Department of Energy, the National Renewable Energy Laboratory recorded and published data across the entire performance range for two commercially available RTUs; one with a two-stage compressor and variable speed supply fan, and another with a fully variable speed compressor, supply fan and condenser fan. This paper details 1) how the design of experiments was created as well as how the units were controlled, and 2) the operational limitations of the two units. The paper will also discuss methods for building energy simulation programs to properly interpret these data sets and integrate them into building energy simulation models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Method of increasing expression of nucleic acid molecules in plants using multiple transcription units

A method of increasing expression of a product encoded by a nucleic acid molecule is provided where in one embodiment multiple plant transcription units comprising a promoter and the nucleic acid molecule are provided. In another embodiment multiple plant transcription units are provided where each promoter is different from the other. In an embodiment the multiple plant transcription units may comprise two, three, four or more plant transcription units. In another embodiment the promoter may be selected from an embryo promoter. Another embodiment provides the promoter may be a globulin promoter. A further embodiment provides the product encoded may be selected from hepatitis b, aprotinin, or a cellulase. Still further embodiments provide the product may be selected from the cellulases E1 and CBH1.

59 BASIC BIOLOGICAL SCIENCES↗

The National Energy Technology Laboratory’s New Unit Process Template Design - LCAXIX

This work was presented at the American Center for Life Cycle Assessment 2019 Conference (LCAXIX) in Tucson, AZ on September 25, 2019. The National Energy Technology Laboratory (NETL) maintains a large unit process (UP) library which holds all documentation for each unit process created by the NETL Life Cycle Analysis (LCA) team. Each NETL unit process includes a Microsoft Excel spreadsheet containing calculations and an accompanying PDF, which thoroughly documents the calculations, parameters, and underlying reasoning and assumptions contained in the Excel file. However, as more and larger public data sources become available, the NETL LCA team has incorporated more data science techniques into their unit process development. NETL is demonstrating a new template which will allow for more flexible and advanced calculation and documentation methods. The new template will support NETL’s dedication to transparency by continuing to provide all information necessary to replicate the UPs.

Krynock, Michelle↗

Comfort units and systems, methods, and devices for use thereof

Despite otherwise uncomfortable conditions in a surrounding environment, a customizable microenvironment can be created around a user to maintain a comfortable temperature and/or humidity level using a comfort unit. For example, the environment may be an office building where conditions are out of the comfortable range to save on energy or for other reasons, a factory/shop environment that is poorly conditioned, or an outdoor location with little to no conditioning. A sensing unit can monitor biometric and environmental data and can determine a comfort level of the user. The comfort unit can then dynamically respond to the determined comfort level and adjust the microenvironment to improve the user's comfort level. The comfort unit can follow the user as the user moves within the macro-environment, or can otherwise move within the macro-environment to achieve certain functions, such as recharging or spatial shifting of thermal load within the overall macro-environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geothermal District Heating in the United States: 2021 Update

As of 2021, there are 23 geothermal district heating (GDH) systems in the United States. Most are over 30 years old. This paper presents an overview of GDH development in the United States and the performance of GDH systems over time. Calculations of the estimated levelized cost of heat (LCOH) for existing U.S. GDH systems were made using NREL's GEOPHIRES tool. Estimated LCOH for existing U.S. GDH systems ranges from $15 to $105/MWhth. This paper explores other factors in GDH development such as resource and system size, capacity factor, and the role of policy. U.S. GDH utilization and deployment are compared to worldwide trends. Results show that the market for GDH in the United States has been weak over the past 40 years due to the combination of inexpensive fossil fuel alternatives (mostly natural gas), lack of incentives focused on heating/cooling, and other factors. Future opportunities for increased GDH deployment in the United States related to increased demand for low-carbon heating and cooling solutions (driven by decarbonization goals in the residential, commercial and industrial heating/cooling sectors, and particularly aggressive ones on college campuses) are outlined. Lastly, this paper identifies policy mechanisms that have been implemented in other countries to incentivize GDH (such as financial incentives targeting GDH, geothermal risk reduction mechanisms, carbon prices benefiting low-carbon heat production, and others).

geothermal district heating↗