Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tracer data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Ice nucleation measurements from DRUM impactors during TRACER campaign in the Houston TX region from July to September 2022

During TRACER, three Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM) were used to collect aerosols for ice nucleation measurements in the Brooks laboratory at Texas A&M University. The three instruments were located at AMF1 in La Porte, Ancillary site in Guy (ANC), and onboard the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V). ROAM-V was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and one of the Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Each DRUM sampler was operated at a flow rate of 23 LPM. Each DRUM has four stages where the aerodynamic diameter size cuts are as follows: stage 1 larger than 3 μm, stage 2 from 3 to 1.2 μm, stage 3 from 1.2 to 0.34 μm, and stage 4 from 0.34 to 0.15 μm. Pretreated aluminum foil was used as a substrate on all stages. At AMF1 and ANC sites, the DRUMs were operated on the shared aerosol inlet, with generous support of the DOE ARM site staff. These instruments rotated 24 mm per day and only contained aluminum foil substrates. Substrates were changed weekly and transported to Texas A&M for storage in -80C freezer until analysis. The DRUM onboard ROAM-V was operated at a faster rotation rate of 150 mm per day to clearly separate the multiple deployment locations for ROAM-V. For the ROAM-V DRUM, substrates were changed every deployment and transported to Texas A&M for storage in -80C freezer until analysis. At Texas A&M, ice nucleation experiments were conducted to measure the ice nucleation temperature of the ambient aerosol samples collected from the three DRUMs using our previously established procedures (Alsante et al., 2023; Fornea et al., 2009; Matthews et al., 2023). For ice nucleation, only samples collected on stage 3 were analyzed, given that these are the most relevant size (1.2 to 0.34 μm diameter) for potential ice nucleating particles. For the AMF1 and ANC sites, we cut and analyzed 2 mm (2-hour) samples. We analyzed the time periods of the AMF1 site instrument when the ROAM-V was deployed. A 72-hour period from July 11th at 23:49 through July 15th at 1:49 was analyzed from the ANC site instrument. For the ROAM-V instrument, we separated the daily samples by site location. Between 1- and 6-hour independent samples were analyzed at each location. We also cut the ROAM-V samples in half to allow for compositional analysis of the aerosol on the other half of the substrate. All viable samples from the ROAM-V were analyzed. Analysis was done using a custom-built ice nucleation apparatus, recently updated to include an array of 16 individual samples (Matthews et al., 2023). On our experimental setup, we used 100 μL of Ultra-High-Performance Liquid Chromatography (UHPLC) water (Sigma Aldrich, >99.9% purity) to wash off the aerosol from the DRUM substrate. Then, we micropipetted 2 μL droplet samples into each of the 16 wells of the array, using hydrophobically coated microscope slides. Experiments would cycle 28 times from 10 C to -40C over a 20-hour period. During analysis of the TRACER samples, nine experiments were conducted with UHPLC water process blanks that followed an identical preparation procedure. The average freezing temperature and standard deviation for these process blanks is -27.7±2.4 C. This data was collected for ARM Field Campaign AFC07023 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Alsante, A. N., Thornton, D. C., & Brooks, S. D. (2023). Ice nucleation catalyzed by the photosynthesis enzyme RuBisCO and other abundant biomolecules. Communications Earth & Environment, 4(1), 51. Fornea, A. P., Brooks, S. D., Dooley, J. B., & Saha, A. (2009). Heterogeneous freezing of ice on atmospheric aerosols containing ash, soot, and soil. Journal of Geophysical Research: Atmospheres, 114(D13). DOI:10.1029/2009JD011958 Matthews, B. H., Alsante, A. N., & Brooks, S. D. (2023). Pollen Emissions of Subpollen Particles and Ice Nucleating Particles. ACS Earth and Space Chemistry.

54 ENVIRONMENTAL SCIENCES↗

Experimental Droplet Impingement on Several Two-Dimensional Airfoils with Thickness Ratios of 6 to 16 Percent

The rate and area of cloud droplet impingement on several two-dimensional swept and unswept airfoils were obtained experimentally in the NACA Lewis icing tunnel with a dye-tracer technique. Airfoil thickness ratios of 6 to 16 percent; angles of attack from 0 deg to 12 deg, and chord sizes from 13 to 96 inches were included in the study. The data were obtained at 152 knots and are extended to other conditions by dimensionless impingement parameters. In general, the data show that the total and local collection efficiencies and impingement limits are primary functions of the modified inertia parameter (in which airspeed, droplet size, and body size are the most significant variables) and the airfoil thickness ratio. Local collection efficiencies and impingement limits also depend on angle of attack. Secondary factors affecting impingement characteristics are airfoil shape, camber, and sweep angle. The impingement characteristics obtained experimentally for the airfoils were within +/-10 percent on the average of the characteristics calculated from theoretical trajectories. Over the range of conditions studied, the experimental data demonstrate that a specific method can be used to predict the impingement characteristics of swept airfoils with large aspect ratios from the data for unswept airfoils of the same series.

Gelder, Thomas F.↗

Rapid Measurements of Aerosol Ionic Composition and 3-10 nm Particle Size Distributions On The NASA P3 To Better Quantify Processes Affecting Aerosols Advected From East Asia

The Particle Into Liquid Sample (PILS) was deployed on the NASA P3 for airborne measurements of fine particle ionic chemical composition. The data have been quality assured and reside in the NASA data archive. We have analyzed our data to characterize the sources and atmospheric processing of fine aerosol particles advected from the region during the experiments. Fine particle water-soluble potassium was found to serve as a useful aerosol tracer for biomass smoke. Ratios of PILS potassium to sulfate are used as a means of estimating the percent contribution of biomass burning to fine particle mass in mixed plumes advecting from Asia. The high correlations between K+ and NO3(sup -) and NH4(sup +)' indicated that biomass burning was a significant source of these aerosol compounds in the region. It is noteworthy that the air mass containing the highest concentrations of fine particles recorded in all of ACE-Asia and TRACE-P appeared to be advecting from the Bejing/Tientsin urban region and also had the highest K(+), NO3(sup -) and NH4(sup +) concentrations of both studies. Based on K+/SO4(sup 2-) ratio's, we estimated that the plume was composed of approx. 60% biomass burning emissions, possibly from the use of bio-fuels in the urban regions.

Weber, Rodney J.↗

Ti Isotopes: Echoes of Grain-Scale Heterogenaity in the Protoplanetary Disk

Calcium-aluminum-rich inclusions (CAIs) are the oldest surviving solids to have formed in the Solar System. Their chemical and isotopic compositions provide a record of the conditions present in the protoplanetary disk where they formed and can aid our understanding of how solids formed in the solar nebula, an important step in the eventual process of planet building. The isotopic compositions of CAIs are primarily controlled by volatility. Evaporation/sublimation are well understood through both theory and experimental work to produce an enrichment in the heavy isotopes of an element, but less is understood about the effects of condensation. Mass-dependent fractionation can potentially provide a record of nebular condensation. Ti is not likely to experience evaporation due to its refractory nature, making it a useful tool for assessing the effects of condensation. We have undertaken a study of the stable isotope fractionation of Ti isotopes as a tracer of processes that predate the last evaporation events affecting CAIs. We compare the 49Ti/47Ti stable isotope ratio with excess 50Ti common in CAIs. We have collected Ti, Mg, Si, and Ca isotope data for a suite of CAIs in order to search for heterogeneity in each of these isotope systems, and for potential correlations among them. We compare our results to expectations for condensation.

Jordan, M. K.↗

Single-Well Push–Pull Tracer Test Analyses to Determine Aquifer Reactive Transport Parameters at a Former Uranium Mill Site (Grand Junction, Colorado)

At a former uranium mill site where tailings have been removed, prior work has determined several potential ongoing secondary uranium sources. These include locations with uranium sorbed to organic carbon, uranium in the unsaturated zone, and uranium associated with the presence of gypsum. To better understand uranium mobility controls at the site, four single-well push–pull tests (with a drift phase) were completed with the goal of deriving aquifer flow and contaminant transport parameters for inclusion in a future sitewide reactive transport model. This goes beyond the traditional use of a constant sorption distribution coefficient (K d ) and allows for the evaluation of alternative remedial injection fluids, which can produce variable K d values. Dispersion was first removed from the resulting data to determine possible reactions before conducting reactive transport simulations. These initial analyses indicated the potential need to include cation exchange, uranium sorption, and gypsum dissolution. A reactive transport model using multiple layers to account for partially penetrating wells was completed using the PHT-USG reactive transport modeling code and calibrated using PEST. The model results quantify the hydraulic conductivity and dispersion parameters using the injected tracer concentrations. Uranium sorption, cation exchange, and gypsum dissolution parameters were quantified by comparing the simulated versus observed geochemistry. All simulations required some cation exchange and calcite equilibrium, and one simulation required gypsum dissolution to improve the model fit for calcium and sulfate. Uranium sorption parameters were not strongly influenced by the other parameter values but were highly influenced by uranium concentrations during the drift phase, with possible kinetic rate limitations. Thus, a future recommendation for such push–pull tests is to collect more geochemical data during the drift phase. The final uranium sorption parameters were within the range of values determined from prior column testing. The flow and transport parameters derived from these single-well push–pull tests will provide initial parameters for any future sitewide reactive transport model.

54 ENVIRONMENTAL SCIENCES↗

AbacusHOD : a highly efficient extended multitracer HOD framework and its application to BOSS and eBOSS data

ABSTRACT We introduce the AbacusHOD model and present two applications of AbacusHOD and the AbacusSummit simulations to observations. AbacusHOD is a Halo Occupation Distribution (HOD) framework written in Python that is particle-based, multitracer, highly generalized, and highly efficient. It is designed specifically with multitracer/cosmology analyses for next-generation large-scale structure surveys in mind, and takes advantage of the volume and precision offered by the new state-of-the-art AbacusSummit cosmological simulations. The model is also highly customizable and should be broadly applicable to any upcoming surveys and a diverse range of cosmological analyses. In this paper, we demonstrate the capabilities of the AbacusHOD framework through two example applications. The first example demonstrates the high efficiency and the large HOD extension feature set through an analysis of full-shape redshift-space clustering of BOSS galaxies at intermediate to small scales ($\lt 30\, h^{-1}$ Mpc), assessing the necessity of introducing secondary galaxy biases (assembly bias). We find strong evidence for using halo environment instead of concentration to trace secondary galaxy bias, a result which also leads to a moderate reduction in the ‘lensing is low’ tension. The second example demonstrates the multitracer capabilities of the AbacusHOD package through an analysis of the extended Baryon Oscillation Spectroscopic Survey cross-correlation measurements between three different galaxy tracers: luminous red galaxies, emission-line galaxies, and quasi-stellar objects. We expect the AbacusHOD framework, in combination with the AbacusSummit simulation suite, to play an important role in a simulation-based analysis of the upcoming Dark Energy Spectroscopic Instrument data sets.

79 ASTRONOMY AND ASTROPHYSICS↗

Water Vapor Tracers as Diagnostics of the Regional Hydrologic Cycle

Numerous studies suggest that local feedback of evaporation on precipitation, or recycling, is a significant source of water for precipitation. Quantitative results on the exact amount of recycling have been difficult to obtain in view of the inherent limitations of diagnostic recycling calculations. The current study describes a calculation of the amount of local and remote sources of water for precipitation, based on the implementation of passive constituent tracers of water vapor (termed water vapor tracers, WVT) in a general circulation model. In this case, the major limitation on the accuracy of the recycling estimates is the veracity of the numerically simulated hydrological cycle, though we note that this approach can also be implemented within the context of a data assimilation system. In this approach, each WVT is associated with an evaporative source region, and tracks the water until it precipitates from the atmosphere. By assuming that the regional water is well mixed with water from other sources, the physical processes that act on the WVT are determined in proportion to those that act on the model's prognostic water vapor. In this way, the local and remote sources of water for precipitation can be computed within the model simulation, and can be validated against the model's prognostic water vapor. Furthermore, estimates of precipitation recycling can be compared with bulk diagnostic approaches. As a demonstration of the method, the regional hydrologic cycles for North America and India are evaluated for six summers (June, July and August) of model simulation. More than 50% of the precipitation in the Midwestern United States came from continental regional tracers, and the local source was the largest of the regional tracers (14%). The Gulf of Mexico and Atlantic 2 regions contributed 18% of the water for Midwestern precipitation, but further analysis suggests that the greater region of the Tropical Atlantic Ocean may also contribute significantly. In general, most North American land regions showed a positive correlation between evaporation and recycling ratio (except the Southeast United States) and negative correlations of recycling ratio with precipitation and moisture transport (except the Southwestern United States). The Midwestern local source is positively correlated with local evaporation, but it is not correlated with water vapor transport. This is contrary to bulk diagnostic estimates of precipitation recycling. In India, the local source of precipitation is a small percentage of the precipitation owing to the dominance of the atmospheric transport of oceanic water. The southern Indian Ocean provides a key source of water for both the Indian continent and the Sahelian region.

Bosilovich, Michael G.↗

Autocorrelation and Multifractal Detrended Fluctuation Analyses Reveal Superdiffusive Mass Transport in Solvent-Filled Nanoporous Media

Fluorescence fluctuation spectroscopy experiments were conducted to better understand the complex mass transport dynamics of organic molecules in liquid-filled nanoporous media. Anodic aluminum oxide (AAO) membranes incorporating 10 and 20 nm diameter cylindrical pores were employed as model materials. Nile red (NR) dye was used as a fluorescent tracer. The dye was dissolved separately in ethanol and toluene at a concentration of 20 nM and used to fill the membrane nanopores. Confocal fluorescence microscopy was employed to capture photon intensity time series data reflecting apparent diffusion of the dye within the pores. Autocorrelation of these data revealed that NR diffusion within the membranes occurred over a broad range of time scales. The autocorrelation decays were fit to a model for one-dimensional diffusion incorporating both fast and slow components having apparent diffusion coefficients, D f and D s , differing by a factor of ∼100. The fast mechanism was attributed to hindered bulk-like diffusion in the central pore cavity, while slow diffusion likely involved absorption of the dye to the pore surfaces. Unfortunately, important evidence of diffusion anomalies is lost in the broad autocorrelation decays obtained. The method of multifractal detrended fluctuation analysis (MF-DFA) was applied to the same data as a means to overcome this limitation. MF-DFA revealed that time series acquired from within the nanopores were multifractal and exhibited evidence of anomalous superdiffusion, likely resulting from the participation of a desorption-mediated diffusion mechanism. Monte Carlo simulations of time series modeling desorption-mediated diffusion in cylindrical nanopores provided support for this assignment. Here, the new knowledge gained affords an improved understanding of hydrocarbon dynamics within nanoporous oil and gas shales.

Diffusion↗

Numerical simulation of the geographical sources of water for Continental Scale Experiments (CSEs) Precipitation

There are several important research questions that the Global Energy and Water Cycle Experiment (GEWEX) is actively pursuing, namely: What is the intensity of the water cycle and how does it change? And what is the sustainability of water resources? Much of the research to address these questions is directed at understanding the atmospheric water cycle. In this paper, we have used a new diagnostic tool, called Water Vapor Tracers (WVTs), to quantify the how much precipitation originated as continental or oceanic evaporation. This shows how long water can remain in the atmosphere and how far it can travel. The model-simulated data are analyzed over regions of interest to the GEWEX community, specifically, their Continental Scale Experiments (CSEs) that are in place in the United States, Europe, Asia, Brazil, Africa and Canada. The paper presents quantitative data on how much each continent and ocean on Earth supplies water for each CSE. Furthermore, the analysis also shows the seasonal variation of the water sources. For example, in the United States, summertime precipitation is dominated by continental (land surface) sources of water, while wintertime precipitation is dominated by the Pacific Ocean sources of water. We also analyze the residence time of water in the atmosphere. The new diagnostic shows a longer residence time for water (9.2 days) than more traditional estimates (7.5 days). We emphasize that the results are based on model simulations and they depend on the model s veracity. However, there are many potential uses for the new diagnostic tool in understanding weather processes and large and small scales.

Bosilovich, Michael G.↗

Implementation of Leak Test Methods for the International Space Station (ISS) Elements, Systems and Components

The International Space Station (ISS has Qualification and Acceptance Environmental Test Requirements document, SSP 41172 that includes many environmental tests such as Thermal vacuum & Cycling, Depress/Repress, Sinusoidal, Random, and Acoustic Vibration, Pyro Shock, Acceleration, Humidity, Pressure, Electromatic Interference (EMI)/Electromagnetic Compatibility (EMCO), etc. This document also includes (13) leak test methods for Pressure Integrity Verification of the ISS Elements, Systems, and Components. These leak test methods are well known, however, the test procedure for specific leak test method shall be written and implemented paying attention to the important procedural steps/details that, if omitted or deviated, could impact the quality of the final product and affect the crew safety. Such procedural steps/details for different methods include, but not limited to: - Sequence of testing, f or example, pressurization and submersion steps for Method I (Immersion); - Stabilization of the mass spectrometer leak detector outputs fo r Method II (vacuum Chamber or Bell jar); - Proper data processing an d taking a conservative approach while making predictions for on-orbit leakage rate for Method III(Pressure Change); - Proper Calibration o f the mass spectrometer leak detector for all the tracer gas (mostly Helium) Methods such as Method V (Detector Probe), Method VI (Hood), Method VII (Tracer Probe), Method VIII(Accumulation); - Usage of visibl ility aides for Method I (Immersion), Method IV (Chemical Indicator), Method XII (Foam/Liquid Application), and Method XIII (Hydrostatic/Visual Inspection); While some methods could be used for the total leaka ge (either internal-to-external or external-to-internal) rate requirement verification (Vacuum Chamber, Pressure Decay, Hood, Accumulation), other methods shall be used only as a pass/fail test for individual joints (e.g., welds, fittings, and plugs) or for troubleshooting purposes (Chemical Indicator, Detector Probe, Tracer Probe, Local Vacuum Chamber, Foam/Liquid Application, and Hydrostatic/Visual Inspection). Any isolation of SSP 41172 requirements have led to either retesting of hardware or accepting a risk associated with the potential system or component pressure integrity problem during flight.

Underwood, Steve↗

Atmospheric Waves and Dynamics Beneath Jupiters Clouds from Radio Wavelength Observations

We observed Jupiter at wavelengths near 2 cm with the Karl G. Jansky Very Large Array (VLA) in February 2015. These frequencies are mostly sensitive to variations in ammonia abundance and probe between approx. 0.5- 2.0 bars of pressure in Jupiters atmosphere; within and below the visible cloud deck which has its base near 0.7 bars. The resultant observed data were projected into a cylindrical map of the planet with spatial resolution of approx. 1500 km at the equator. We have examined the data for atmospheric waves and observed a prominent bright belt of radio hotspot features near 10 N, likely connected to the same equatorial wave associated with the 5-m hotspots. We conducted a passive tracer power spectral wave analysis for the entire map and latitude regions corresponding to eastward and westward jets and compare our results to previous studies. The power spectra analysis revealed that the atmosphere sampled in our observation (excluding the NEB region) is in a 2-D turbulent regime and its dynamics are predominately governed by the shallow water equations. The Great Red Spot (GRS) is also very prominent and has a noticeable meridional asymmetry and we compare it, and nearby storms, with optical images. We find that the meridional radio profile has a global north-south hemisphere distinction and find correlations of it to optical intensity banding and to shear zones of the zonal wind profile over select regions of latitude. Amateur optical images taken before and after our observation complemented the radio wave- length map to investigate dynamics of the equatorial region in Jupiters atmosphere. We find that two radio hotspots at 2 cm are well correlated with optical plumes in the NEB, additionally revealing they are not the same 5 m hotspot features correlated with optical dark patches between adjacent plumes. This analysis exploits the VLAs upgraded sensitivity and explores the opportunities now possible when studying gas giants, especially atmospheric dynamics of layers beneath upper level clouds.

radio observations↗

Time-History Statistics of Soot Formation in A Model Gas Turbine Combustor

Soot formation is a complex dynamic and intermittent process determined by properties of the fuel, combustor design, and combustor operation. Although the major steps in soot formation (i.e., formation of precursors, inception, growth and evolution) are similar for a variety of carbonaceous fuels, applications, and operating conditions, it remains unclear when the temporal transition between these steps occurs. An engineering prediction tool coupled with computational fluid physics (CFD), therefore needs to accurately model all these complex steps. To develop such a model, we propose the time-history concept for understanding the time dependency of soot formation as a function of local properties (i.e., temperature, velocity, local fuel air ratio, etc.). We continue our previous work with modeling the DLR aero-combustor [1] with our updated in-house CFD code, Open National Combustion Code (OpenNCC), that now includes a Multiple Time-Scale Flamelet Progress Variable approach and a the semi-empirical two-equation soot model. We injected massless tracer particles upstream of the injector region of the combustor to collect time-history statistics of the solution variables. The correlations between the collected statistics with respect to the experimental soot volume fraction data showed that time-history effect of certain flow variables, including turbulent kinetic energy (TKE), and multiple species is indeed important for soot formation. We then conducted a time-history based correlation analysis to determine the key species and the concentration ranges critical for soot formation (C6H5-based nucleation, acetylene-based surface growth, and oxidation with OH and O2). Based on the time-history correlation coefficient (THCC) analysis, we propose possible modifications to improve the current two-equation model.

LES↗

JWST Reveals Spectral Tracers of Recent Surface Modification on Europa

Europa has been modified by a variety of geologic processes, exposing internally-derived materials that are heavily irradiated by charged particles trapped in Jupiter’s magnetosphere. Prior spectral analysis of H2O ice on Europa relied on low signal-to-noise data at wavelengths >2.5 µm, limiting assessment of a 3.1 µm Fresnel peak that is diagnostic of exposed crystalline ice. We report new measurements of H2O ice spectral features using high signal-to-noise data collected by the NIRSpec spectrograph (1.48 – 5.35 µm) on the James Webb Space Telescope. These data reveal a narrow 3.1 µm crystalline H2O ice Fresnel peak, which is primarily located at southern latitudes in Tara and Powys Regiones. Our analysis indicates that crystalline ice exposed in these low-latitude regiones is likely sustained by ongoing thermal (re)crystallization outpacing charged particle amorphization of the top ∼10 µm of Europa’s regolith over short timescales (<15 days). We also measured H2O ice features centered near 1.5 µm, 1.65 µm, and 2.0 µm, and a broad 3.6 µm H2O continuum peak, which are all stronger at northern latitudes, in contrast to the 3.1 µm Fresnel peak identified at southern latitudes. These results support the hypothesis that H2O ice in Europa’s regolith is vertically stratified, with amorphous ice grains dominating its exposed surface, except in Tara and Powys Regiones. We also find that a previously detected 4.38 µm 13CO2 feature is present almost exclusively at southern latitudes in Tara and Powys Regiones, likely derived from an internal source of carbon-bearing material.

Surface processes (2116)↗

TRACER-MAP_2022_absorption_coefficient

Absorption coefficient for PM2.5 measured by the Tri-color Absorption Photometer averaged every 2 minutes for July-August 2022. The location of the measurement is indicated by latitude and longitude coordinates; TRACER-MAP included time at the AMF site in La Porte and additional sites around Houston. Three wavelengths are reported: 365, 520 and 640 nm. The AAE is also reported using the three wavelengths. The data is reported as 2 minute averages.

54 ENVIRONMENTAL SCIENCES↗

Advanced atmospheric sounder and imaging radiometer /AASIR/ for STORMSAT

The principal mission of the three-axis stabilized STORMSAT spacecraft is to provide the necessary meteorological data for tracking, studying the detailed structure, and modeling mesoscale weather phenomena. In the area of mesoscale events, the following meteorological objectives are indicated: high-quality imagery, visible and infrared; wind velocity from cloud tracers (1 m/sec), atmospheric temperature profiles (1 K), and atmospheric humidity sounding. These objectives are reflected in the functional characteristics of the AASIR, which is a second generation meteorological sensor based on the Visible Infrared Spin-Scan Radiometer (VISSR) and the Atmospheric Sounder (VAS). The AASIR design and interface constraints with the STORMSAT spacecraft is discussed.

Chase, S. C.↗

Southern Hemisphere Carbon Monoxide Inferannual Variability Observed by Terra/Measurement of Pollution in the Troposphere (MOPITT)

Biomass burning is an annual occurrence in the tropical southern hemisphere (SH) and represents a major source of regional pollution. Vegetation fires emit carbon monoxide (CO), which due to its medium lifetime is an excellent tracer of tropospheric transport. CO is also one of the few tropospheric trace gases currently observed from satellite and this provides long-term global measurements. In this paper, we use the 5 year CO data record from the Measurement Of Pollution In The Troposphere (MOPITT) instrument to examine the inter-annual variability of the SH CO loading and show how this relates to climate conditions which determine the intensity of fire sources. The MOPITT observations show an annual austral springtime peak in the SH zonal CO loading each year with dry-season biomass burning emissions in S. America, southern Africa, the Maritime Continent, and northwestern Australia. Although fires in southern Africa and S. America typically produce the greatest amount of CO, the most significant inter-annual variation is due to varying fire activity and emissions from the Maritime Continent and northern Australia. We find that this variation in turn correlates well with the El Nino Southern Oscillation precipitation index. Between 2000 and 2005, emissions were greatest in late 2002 and an inverse modeling of the MOPITT data using the MOZART chemical transport model estimates the southeast Asia regional fire source for the year August 2002 to September 2003 to be 52 Tg CO. Comparison of the MOPITT retrievals and NOAA surface network measurements indicate that the latter do not fully capture the inter-annual variability or the seasonal range of the CO zonal average concentration due to biases associated with atmospheric and geographic sampling.

Edwards, D. P.↗

Measurement of the galaxy-velocity power spectrum of DESI tracers with the kinematic Sunyaev-Zeldovich effect using DESI DR2 and ACT DR6

Joint analyses of high-resolution CMB temperature maps with galaxy surveys provide a unique way to reconstruct the radial velocity field of the underlying matter distribution via the kinematic Sunyaev-Zeldovich (kSZ) effect. Using data from the Atacama Cosmology Telescope (ACT) DR6 and the Dark Energy Spectroscopic Instrument (DESI) DR2, we present radial velocity reconstructions for luminous red galaxies (LRGs), emission-line galaxies (ELGs), and quasars (QSOs). Leveraging the spectroscopic data, we are able to reliably model the foreground contamination and report a negligible impact on our main observables. We detect the velocity-galaxy cross-correlation at $17.0σ$ for LRGs, and for the first time, at $8.3σ$ for ELGs and $6.8σ$ for QSOs. We further report the first detection of the velocity-velocity correlation using LRGs at $3.1σ$, as well as the highest cumulative detection of the kSZ effect to date at $20.8 σ$. Similarly to previous results, we find a lower amplitude of the kSZ signal compared to our fiducial halo model prediction and electron profile assuming a Battaglia profile. Combining these new observables, we obtain constraints on local-type primordial non-Gaussianity (PNG): $f_{\rm NL}^{\rm loc} = 15.9_{-34.4}^{+34.6}$ at 68% confidence, which represents the tightest constraint to date derived from the velocity field. The measurements presented here already exhibit lower noise on a per-mode basis than the galaxy auto-correlation on the largest scales, $k<0.004~\rm{Mpc^{-1}}$, highlighting the key role these observables will play in the context of future CMB experiments such as the Simons Observatory.

Chaussidon, Edmond [LBL, Berkeley] (ORCID:00000001↗

Evaluation of Observed and Modelled Aerosol Lifetimes Using Radioactive Tracers of Opportunity and an Ensemble of 19 Global Models

Aerosols have important impacts on air quality and climate, but the processes affecting their removal from the atmosphere are not fully understood and are poorly constrained by observations. This makes modelled aerosol lifetimes uncertain. In this study, we make use of an observational constraint on aerosol lifetimes provided by radionuclide measurements and investigate the causes of differences within a set of global models. During the Fukushima Dai-Ichi nuclear power plant accident of March 2011, the radioactive isotopes cesium-137 (Cs-137) and xenon-133 (Xe-133) were released in large quantities. Cesium attached to particles in the ambient air, approximately according to their available aerosol surface area. Cs-137 size distribution measurements taken close to the power plant suggested that accumulation mode (AM) sulfate aerosols were the main carriers of cesium. Hence, Cs-137 can be used as a proxy tracer for the AM sulfate aerosol's fate in the atmosphere. In contrast, the noble gas Xe-133 behaves almost like a passive transport tracer. Global surface measurements of the two radioactive isotopes taken over several months after the release allow the derivation of a lifetime of the carrier aerosol. We compare this to the lifetimes simulated by 19 different atmospheric transport models initialized with identical emissions of Cs-137that were assigned to an aerosol tracer with each model's default properties of AM sulfate, and Xe-133 emissions that were assigned to a passive tracer. We investigate to what extent the modelled sulfate tracer can reproduce the measurements, especially with respect to the observed loss of aerosol mass with time. Modelled Cs-137and Xe-133 concentrations sampled at the same location and times as station measurements allow a direct comparison between measured and modelled aerosol lifetime. The e-folding lifetime e, calculated from station measurement data taken between 2 and 9 weeks after the start of the emissions, is 14.3 days (95% confidence interval 13.1-15.7 days). The equivalent modelled e lifetimes have a large spread, varying between 4.8 and 26.7 days with a model median of 9.42.3 days, indicating too fast a removal in most models. Because sufficient measurement data were only available from about 2 weeks after the release, the estimated lifetimes apply to aerosols that have undergone long-range transport, i.e. not for freshly emitted aerosol. However, modelled instantaneous lifetimes show that the initial removal in the first 2 weeks was quicker (lifetimes between 1 and 5 days) due to the emissions occurring at low altitudes and co-location of the fresh plume with strong precipitation. Deviations between measured and modelled aerosol lifetimes are largest for the northernmost stations and at later time periods, suggesting that models do not transport enough of the aerosol towards the Arctic. The models underestimate passive tracer (Xe-133) concentrations in the Arctic as well but to a smaller extent than for the aerosol (Cs-137) tracer. This indicates that in addition to too fast an aerosol removal in the models, errors in simulated atmospheric transport towards the Arctic in most models also contribute to the underestimation of the Arctic aerosol concentrations.

Radioactive isotopes↗