Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Root cause analysis of a molten salt pump in FLUSTFA

The primary salt pump installed in the high-temperature FLUoride Salt Test Facility (FLUSTFA) was successfully operated for some time, but later ceased operation. To understand what occurred, a Root Cause Analysis (RCA) was performed. Steps taken to try to get the pump operational include adjusting the shaft position, increasing the heating power of the tape heaters on the pump volute, and manually rotating the pump shaft. While removing the insulation, corrosion was noted on the outside of the pump volute, and decolorization of the insulation and tape heaters was observed. Significant corrosion products were also observed in the pump itself and the piping connected to the pump. The nitrogen cover gas was maintained from before salt was introduced into the loop until the pump was dismounted and continues to be maintained even after the pump was removed. After considering probable scenarios, causes were assigned and corrective actions were developed to prevent those causes. Then, the RCA was presented to an advisory committee for review, the “Review Committee,” consisting of experts in large molten salt systems: Brandon Haugh, David Holcomb, Kevin Robb, and Vicente Rojas. As a result, the advisory committee provided comprehensive feedback, which have been incorporated into a revised RCA. Findings have then been summarized and reported in this publication.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

SMR safety through HTTF modeling and benchmark efforts for code validation for gas-cooled reactor applications

Accurate modeling and simulation tools for thermal-hydraulics calculations are a key element needed to design and license new advanced reactors including Small Modular Reactors (SMR) and Microreactors. Uncertainties in modeling and simulation can have significant safety and economic implications. The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled prismatic-block nuclear reactors. High-quality measurement data is available from the HTTF that is suitable for a thermal-hydraulics code validation benchmark for gas-cooled reactor simulations. Here, this paper summarizes individual HTTF modeling efforts to date for tool validation at Idaho National Laboratory (INL), Argonne National Laboratory (ANL), Oregon State University (OSU) and Canadian Nuclear Laboratories (CNL) using system thermal-hydraulics codes, Computational Fluid Dynamics (CFD) codes and system-CFD code couplings. Also, the paper introduces the ongoing OECD Nuclear Energy Agency (NEA) High Temperature Gas Reactor Thermal-Hydraulics (HTGR T/H) benchmark that allows for better comparisons of results between different international modeling teams. The benchmark provides well defined computational problems that include code-to-code comparisons and comparisons to measured data. These problems provide an avenue for quantifying accuracy and identifying sources of uncertainty in thermal-hydraulics calculations, including in measured thermophysical properties, as part of validation for gas-cooled reactor simulation tools.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.

Gardon gauge↗

Volumetric efficiency and pressure pulsations of a triplex reciprocating supercritical CO 2 pump

A reciprocating triplex pump has been integrated into a closed-loop supercritical carbon dioxide test facility. The pump is designed to compress liquid or supercritical carbon dioxide and has a maximum volumetric flow rate of 51 L/min. A sweep across the pump’s speed range of 100–1000 rev/min was performed with inlet conditions between 60 and 160 bar. The volumetric efficiency was found to increase as pump speed increased from 10 to 40 % before it plateaued at higher pump speeds. The mechanical efficiency increased linearly with pump speed and was not affected by system pressure. Pressure pulsations caused by the plungers and valves were also measured at each speed. Additionally, a 35-liter buffer volume, connected near the pump’s discharge was isolated at each speed to determine its effectiveness as a pulsation dampener. Overall the reciprocating pump was shown to perform exceptionally with liquid or supercritical inlet conditions applicable to many supercritical fluid applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Building fault detection data to aid diagnostic algorithm creation and performance testing

It is estimated that approximately 4-5% of national energy consumption can be saved through corrections to existing commercial building controls infrastructure and resulting improvements to efficiency. Correspondingly, automated fault detection and diagnostics (FDD) algorithms are designed to identify the presence of operational faults and their root causes. A diversity of techniques is used for FDD spanning physical models, black box, and rule-based approaches. A persistent challenge has been the lack of common datasets and test methods to benchmark their performance accuracy. This article presents a first of its kind public dataset with ground-truth data on the presence and absence of building faults. This dataset spans a range of seasons and operational conditions and encompasses multiple building system types. It contains information on fault severity, as well as data points reflective of the measurements in building control systems that FDD algorithms typically have access to. The data were created using simulation models as well as experimental test facilities, and will be expanded over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A labeled dataset for building HVAC systems operating in faulted and fault-free states

Abstract Open data is fueling innovation across many fields. In the domain of building science, datasets that can be used to inform the development of operational applications - for example new control algorithms and performance analysis methods - are extremely difficult to come by. This article summarizes the development and content of the largest known public dataset of building system operations in faulted and fault free states. It covers the most common HVAC systems and configurations in commercial buildings, across a range of climates, fault types, and fault severities. The time series points that are contained in the dataset include measurements that are commonly encountered in existing buildings as well as some that are less typical. Simulation tools, experimental test facilities, and in-situ field operation were used to generate the data. To inform more data-hungry algorithms, most of the simulated data cover a year of operation for each fault-severity combination. The data set is a significant expansion of that first published by the lead authors in 2020.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hard X-ray inverse Compton scattering at photon energy of 87.5 keV

Abstract Production of hard X-ray via inverse Compton scattering at photon energies below 100 keV range aimed at potential applications in medicine and material research is reported. Experiments have been performed at the Brookhaven National Laboratory, Accelerator Test Facility, employing the counter collision of a 70 MeV, 0.3 nC electron beam with a near infra-red Nd: YAG laser (1064 nm wavelength) pulse containing ~ 100 mJ in a single shot basis. The radiation distribution of the scattered photon beam is assessed to be sufficiently quasi monochromatic to produce clear contrast from the Au K - edge at 80.7 keV.

43 PARTICLE ACCELERATORS↗

A pulsed-power implementation of “Laser Gate” for increasing laser energy coupling and fusion yield in magnetized liner inertial fusion (MagLIF)

Magnetized Liner Inertial Fusion (MagLIF) at Sandia National Laboratories involves a laser preheating stage,where a few-ns laser pulse passes through a few-micron-thick plastic window to preheat gaseous fusion fuel contained within the MagLIF target. Interactions with this window reduce heating e ciency and mix window and target materials into the fuel. A recently proposed idea called \Laser Gate" involves removing the window well before the preheating laser is applied. In this article, we introduce experimental proof-of-principle results for a pulsed-power implementation of Laser Gate, where a thin current-carrying wire weakens the perimeter of the window, allowing the fuel pressure to push the window open and away from the preheating laser path. For this e ort, transparent targets were fabricated and a test facility capable of studying this version of Laser Gate was developed. A 12-frame bright- eld laser schlieren/shadowgraphy imaging system captured the window opening dynamics on microsecond timescales. The images exhibit that the window remains largely intact as it opens and detaches from the target. A column of escaping pressurized gas appears to prevent the detached window from inadvertently moving into the preheating laser path.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operational Modes of a 2.0 MWth Chloride Molten-Salt Pilot-Scale System

The limit of traditional solar-salt thermal stability is around 600 °C with ambient air as the cover gas. Nitrate molten salt concentrating solar power (CSP) systems are currently deployed globally and are considered to be state-of the art heat transfer fluids (HTFs) for present day high-temperature operation. However, decomposition challenges occur with these salts for operation beyond 600 C. Although slightly higher limits may be possible with solar salt, to fully realize SunShot efficiency goals of $15/kWhth HTFs and an LCOE of 6¢/kWh, molten-salt technologies working at higher temperatures (e.g., 650 °C to 750 °C) will require an alternative salt chemistry composition, such as chlorides. In this investigation a 2.0MWth Pilot-scale CSP plant design is developed to assess thermodynamic performance potential for operation up to 720 C. Here, an Engineering Equation Solver (EES) model is developed with respect to 14 state-points from the base of a solar tower at the Sandia National Laboratories, National Solar Thermal Test Facility (NSTTF), to solar receiver mounted 120 ft. above the ground. The system design considers a ternary chloride ternary chloride (20%NaCl/40%MgCl/40%KCl by mol%) salt as the HTF, with 6 hrs. of storage and a 1 MWth primary salt to sCO2 heat exchanger. Preliminary system modelling results indicate a minimum non-dimensional Cv of 60 required for both cold and hot-side throttle recirculation valves for the operational pump operating between speeds of 1800 and 2400 RPM. Further receiver comparison study results suggest that the ternary salt requires an average 15.2% higher receiver flux with a slightly lower calculated receiver efficiency when compared to a binary carnelite salt to achieve a 2.0 MWth desired input power design.

associated liquids↗

Performance demonstration of vacuum microwave components critical for the operation of the ITER low-field side reflectometer

Final design studies in preparation for manufacturing have been performed for functional components of the vacuum portion of the ITER Low-Field Side Reflectometer (LFSR). These components consist of an antenna array, electron cyclotron heating (ECH) protection mirrors, phase calibration mirrors, and vacuum windows. Evaluation of these components was conducted at the LFSR test facility and DIII-D. The antenna array consists of six corrugated-waveguide antennas for simultaneous profile, fluctuation, and Doppler measurements. A diffraction grating, incorporated into the plasma-facing miter bend, provides protection of sensitive components from stray ECH at 170 GHz. For in situ phase calibration of the LFSR profile reflectometer, an embossed mirror is incorporated into the adjacent miter bend. Measurements of the radiated beam profile indicate that these components have a small, acceptable effect on mode conversion and beam quality. Baseline transmission characteristics of the dual-disk vacuum window are obtained and are used to guide ongoing developments. Preliminary simulations indicate that a surface-relief structure on the window surfaces can greatly improve transmission. The workability of real-time phase measurements was demonstrated on the DIII-D profile reflectometer. The new automated real-time analysis agrees well with the standard post-processing routine.

47 OTHER INSTRUMENTATION↗

Analysis of AP1000 Small-Break Loss-of-Coolant Accident Using Reactor Transient Simulator

The Westinghouse Electric Company’s Advanced Passive Reactor (AP1000) is characterized by the incorporation of passive safety systems (PSSs) designed to ensure core cooling during transient events. The assessment of PSSs requires evaluation of their performance through a combination of experiments and simulations employing various thermal-hydraulic codes. In addition, detailed evaluation of PSSs for a specific reactor system transient analysis such as loss-of-coolant-accident analysis supports understanding representative integral effects test facility development and the further evolution model development and assessment process. Developing a reactor system code is a complex and time-consuming process that requires significant engineering expertise and effort. It can take several months to even years to complete in the early stages of reactor system design and analysis. However, this process can be expedited through the use of transient simulator models for similar reactor systems, which can be used for lesson learning and training purposes. This study uses the Personal Computer Transient Analyzer (PCTRAN) code. The main advantage of PCTRAN is its ease of use and ability to run faster than real time. This study presents the results obtained for a small-break loss-of-coolant accident (SBLOCA) for two breaks using the full version (licensed) of PCTRAN. The purpose of this investigation is to evaluate the overall system behavior during the postulated SBLOCA event as well as assess the capability of the PCTRAN code to reproduce the system response during transient events. The obtained results were compared with the Westinghouse NOTRUMP system code. The PCTRAN code proved to be reliable in predicting the qualitative behavior of the system in both transient cases. As for the system response, it was found that it is contingent on the activation time of the PSSs. The differences in reactor coolant system pressure between the two codes were attributed to the critical flow model and simplification of mass and energy balance. Despite PCTRAN’s limitations, it can still provide a reasonable prediction of various reactor parameters such as pressure, mass flow rate, and void fraction during a SBLOCA scenario. It is worth noting that PCTRAN currently employs a bulk approach similar to that of the Modular Accident Analysis Program (MAAP) and MELCOR codes. However, the upcoming version of PCTRAN will include an artificial intelligence–based detection and accident prevention system, as well as different models for different reactor components. Consequently, PCTRAN has the potential to be upgraded to match the system thermal-hydraulic codes of the U.S. Nuclear Regulatory Commission and become more widely used in cybersecurity to safeguard nuclear power plants from cyberattacks.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A New 1D Model for Thermal Mixing and Stratification in Advanced Reactor Transients

Thermal mixing and stratification in large pools and enclosures play a critical role in the safety and performance of pool-type nuclear reactors, particularly during transient scenarios involving significant temperature differences between incoming and bulk coolant. Accurate modeling of these phenomena is essential for predicting system behavior and supporting passive safety features such as natural circulation. Here, this paper presents a new 1D model for thermal mixing and stratification, developed and implemented in the SAM code. The model represents a large pool as 1D coolant jet channels and zero-dimensional bulk pool volumes, enabling the simulation of a wide range of flow configurations, including hot and cold jet interactions, stratified layers, and the influence of complex geometries such as ceilings, free surfaces, and internal obstacles. Heat exchange between jet and pool regions is governed by closure relations calibrated against 3D computational fluid dynamics (CFD) simulations. The model improves upon earlier approaches by incorporating time-dependent jet characteristics and capturing the associated delay effects more accurately. Code-to-code comparisons and validation against experimental data from the Thermal Stratification Test Facility demonstrate the model’s accuracy and flexibility. This work offers two key contributions: (1) an efficient and robust method for simulating thermal mixing and stratification at the system level, eliminating the need for external coupling between system analysis codes and CFD, and (2) a significant enhancement of SAM’s capabilities to analyze thermal stratification phenomena in advanced reactor systems.

SAM↗

Bayesian Parameter Estimation of the k-ω Shear Stress Transport Model for Accurate Simulations of Impinging-Jet Heat Transfer

Given the lack of fusion-relevant component test facilities, current estimates of the thermo-fluid performance of plasma-facing components are based for the most part on numerical simulations. A major source of uncertainty in these simulations is the semiempirical turbulence (closure) models for the Reynolds stresses appearing in the governing Reynolds-averaged Navier-Stokes equations, which involve a set of constants that depend upon the flow. The objective of this study is to evaluate Bayesian parameter estimation of turbulence closure constants in ANSYS Fluent to model heat transfer in impinging jets. The Bayesian statistical calibration produces a probability distribution for these constants from experimental data; the maximum a posteriori estimates are then taken to be the calibrated constants, or parameters. The turbulence model constants are calibrated using an experimental study of a submerged jet of air impinging on a flat heated surface at Reynolds numbers Re = O(10 4 ) and impingement distance in jet diameters H/d = 2. Numerical predictions using the calibrated model parameters are then compared with those generated using the default constants. Predictions obtained with model parameters calibrated on datasets of two different sizes are compared to evaluate the effect of the number of calibration samples. Lastly, the extrapolative ability of the calibrated model is examined by predictions at a Re beyond the calibration values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary design overview and performance assessment of the ITER low-field side reflectometer

The design of the ITER low-field side reflectometer (LFSR) has matured to a complete end-to-end preliminary design. LFSR will supply three key plasma measurements: (1) electron density profile, (2) electron density fluctuations, and (3) poloidal rotation. Simultaneous measurements of the three quantities are enabled by an array of six monostatic antennas which inject from an equatorial port on the outboard side of the ITER vessel. Low-loss transmission lines, consisting of corrugated, overmoded waveguide and miter bends, transmit the 30–165 GHz, O- and X-mode signals to and from the ITER plasma. Integrated transmission-line components serve a range of purposes, such as protection from high-power stray radiofrequency radiation, accommodation of transmission-line displacement, and simultaneous measurement of reference and plasma phases during the discharge. Broadband transmission signals are realized by full-band microwave transceivers combined with quasi-optical multiplexing. A field-programmable gate array (FPGA) processor demodulates the profile reflectometer signals, enabling real-time density profile measurements for plasma control system feedback. A full-scale transmission line test facility provides an integrated environment to assess the performance of critical LFSR components. Theoretical modeling together with insertion loss measurements provide the basis for a comprehensive power budget, which accounts for transmitted output power, transmission-line losses, antenna coupling, and plasma effects. Results indicate that high signal-to-noise ratios are achievable with the current design. A synthetic reflectometer model, using real design parameters and baseline ITER profiles, has been developed to estimate the return signal. With evolving microwave and data acquisition technologies, full-band, ultrafast sweeps (<1 μs) will be realizable for ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Closing the Accuracy Gap in Tandem Photovoltaic Testing: An Accessible and Efficient Spectral Tuning Method Using LED-Based Simulators for Research Laboratories and Industry

Accurate performance calibration of multijunction (MJ) solar cells is critical for advancing this technology toward large-scale terrestrial application, yet existing testing methods developed by photovoltaics calibration laboratories remain prohibitively complex and resource intensive for most research laboratories. Current approaches rely on expensive multisource simulators and/or intricate spectral tuning algorithms, limiting accessibility and hindering standardized comparisons of emerging MJ technologies such as perovskite-based tandems. This paper introduces a streamlined spectral irradiance adjustment method for light-emitting diode (LED)-based solar simulators, which are increasingly adopted in the photovoltaics community due to their versatility and cost-effectiveness. The method we present bins LED channels into groups based on the number of junctions of the MJ photovoltaic device under test (DUT) and their corresponding band gaps and incorporates an automated tuning algorithm that eliminates the need to adjust each channel’s irradiance individually. This tuning algorithm requires the relative spectral responsivities of both the DUT and a broadband reference cell, as well as a calibrated spectroradiometer. Measurement validation across various MJ devices, including III-V and perovskite/silicon tandems, demonstrates excellent agreement within 1% with well-established xenon-tungsten multisource simulators and associated tuning algorithms. By enabling precise spectral tuning with readily available equipment and a simple tuning algorithm, our approach bridges the measurement accuracy gap between research laboratories and accredited testing facilities, fostering more reliable device comparisons and accelerating the translation of MJ technologies into real-world energy systems.

14 SOLAR ENERGY↗

Beam dynamics driven design of powerful energy recovery linac for experiments

Powerful ERL for experiments (PERLE) is a novel energy recovery linac (ERL) test facility [1], designed to validate choices for a 50 GeV ERL foreseen in the design of the Large Hadron Electron Collider and the Future Circular Collider and to host dedicated nuclear and particle physics experiments. Its main goal is to demonstrate the high current, continuous wave, multipass operation with superconducting cavities at 802 MHz. With very high beam power (10 MW), PERLE offers an opportunity for controllable study of every beam dynamic effect of interest in the next generation of ERLs and becomes a “stepping stone” between the present state-of-the-art 1 MW ERLs and the future 100 MW scale applications. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Fabrication and testing of the transition section between modules of a wakefield accelerator

The fabrication process is presented for a typical transition section located between each cylindrical corrugated waveguide structure comprising the wakefield accelerator module. The transition section includes couplers for extracting the 180 GHz TM 01 accelerating mode and separate couplers for extracting the 190 GHz HE 11 dipole mode, both modes induced by the electron bunch traversing the cylindrical corrugated waveguide structure. Extraction of the high-power accelerating mode reduces the heat load due to the subterahertz wave power dissipation within the corrugated accelerating structure. Extraction of the low-power dipole mode serves the purpose of detecting the electron bunch transverse oscillations within the wakefield accelerator and identifying the onset of beam breakup instability. Comprehensive testing of the fully functional transition section with an electron beam was done at the Accelerator Test Facility in Brookhaven National Laboratory which verified the functionality of the transition section. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗