Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “test data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Advanced solar thermal storage medium test data and analysis

A comparative study has been made of experimentally obtained heat transfer and heat storage characteristics of a solar thermal energy storage bed utilizing containerized water or phase change material (PCM) and rock or brick. It is shown that (1) containers with an L/D ratio of 0.80 and a mass/surface area ratio of 2.74 in a random stacking arrangement have the optimum heat transfer characteristics; and (2) vertical stacking has the least pressure drop across the test bed. It is also found that standard bricks with appropriate holes make an excellent storage medium.

Saha, H.↗

Preliminary studies of tunnel interface response modeling using test data from underground storage facilities.

In attempting to detect and map out underground facilities, whether they be large-scale hardened deeply-buried targets (HDBT's) or small-scale tunnels for clandestine border or perimeter crossing, seismic imaging using reflections from the tunnel interface has been seen as one of the better ways to both detect and delineate tunnels from the surface. The large seismic impedance contrast at the tunnel/rock boundary should provide a strong, distinguishable seismic response, but in practice, such strong indicators are often lacking. One explanation for the lack of a good seismic reflection at such a strong contrast boundary is that the damage caused by the tunneling itself creates a zone of altered seismic properties that significantly changes the nature of this boundary. This report examines existing geomechanical data that define the extent of an excavation damage zone around underground tunnels, and the potential impact on rock properties such as P-wave and S-wave velocities. The data presented from this report are associated with sites used for the development of underground repositories for the disposal of radioactive waste; these sites have been excavated in volcanic tuff (Yucca Mountain) and granite (HRL in Sweden, URL in Canada). Using the data from Yucca Mountain, a numerical simulation effort was undertaken to evaluate the effects of the damage zone on seismic responses. Calculations were performed using the parallelized version of the time-domain finitedifference seismic wave propagation code developed in the Geophysics Department at Sandia National Laboratories. From these numerical simulations, the damage zone does not have a significant effect upon the tunnel response, either for a purely elastic case or an anelastic case. However, what was discovered is that the largest responses are not true reflections, but rather reradiated Stoneley waves generated as the air/earth interface of the tunnel. Because of this, data processed in the usual way may not correctly image the tunnel. This report represents a preliminary step in the development of a methodology to convert numerical predictions of rock properties to an estimation of the extent of rock damage around an underground facility and its corresponding seismic velocity, and the corresponding application to design a testing methodology for tunnel detection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The reduction of airplane flight test data to standard atmosphere conditions

This report was prepared for the National Advisory Committee for Aeronautics in order to supply the need of practical methods of reducing observed performance to standard conditions with a minimum of labor. The first part gives a very simple approximate method of reducing performance in climb, and is particularly adapted to work not requiring extreme accuracy. The second part gives a somewhat more elaborate and more accurate method which is well suited to general flight test reduction. The third part gives the conventional method of calibrating air-speed indicators and reducing the indicated speeds to true air speeds. An appendix gives working tables and charts for the standard atmosphere. (author)

Diehl, Walter S↗

A primer for the statistical analysis of field test data obtained from screening instruments that detect contraband

A variety of federal agencies have continuing development programs whose mission is to advance the technology for monitoring the flow of commerce to detect the presence of contraband. The items of interest can be undeclared goods on which taxes or tariffs are due, or illegal substances such as recreational drugs, or banned weapons or weapon parts such as nuclear material, or nuclear weapons being moved in violation of a nonproliferation treaty. As these technologies continue in development they are assessed periodically in experimental testing either in the laboratory or in the field. The testing programs sometimes may resemble those employed by the pharmaceutical industry and their goal is to determine whether these technologies are efficacious and whether there are unanticipated negative consequences. The goal of the analysis is to determine the most probable value of P and estimate its uncertainty or the confidence that it falls within an acceptable range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Local stiffener and skin pocket buckling prediction by special PASCO modeling technique: Correlation to test data

Waffle panels are often used on fuselage structures such as that of the Space Shuttle. The waffle panel design is an efficient design for carrying biaxial, in-plane, and shear loads. The WAFFLE program was designed for application on waffle panels. The Panel Analysis and Sizing Code (PASCO) program was designed for analyzing and sizing uniaxially stiffened panels. The application of the PASCO program in conjunction with the WAFFLE program is discussed to account for both the fillet radius and the presence of stiffness in both directions. The results of the tests are used to verify that these adjustments are valid and necessary if accurate analysis of the waffle panel is to be achieved.

Yin, Dah N.↗

OECD MCCI Project Small-Scale Water Ingression and Crust Strength Tests (SSWICS) SSWICS-10 Test Data Report (Thermal Hydraulic Results)

The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These experiments provided unique, and for the most part repeatable, indications of heat transfer mechanisms that could provide long term debris cooling. However, the results did not demonstrate definitively that a melt would always be completely quenched. This was due at least partially to the fact that the crust anchored to the test section sidewalls in every test, which led to melt/crust separation, even at the largest test section lateral span of 1.2 m. This decoupling is not expected for a typical reactor cavity where the lateral span is much larger, ~5-6 m. Instead, the crust is expected to fracture under the weight of the coolant and the crust itself so that coolant contact with the melt is maintained. However, because of a lack of knowledge of the strength of the crust, one cannot be certain that it would actually fracture under such circumstances. As part of the MCCI-1 and MCCI-2 programs, a series of separate-effects experiments has been conducted to measure corium quench rates and crust strength to investigate the various debris cooling mechanisms identified in the MACE program. Each quench test involved cooling a molten mass of UO 2 , ZrO 2 , and concrete constituents, which produced a corium ingot that was later load tested to determine its mechanical strength. The quench tests were designed to optimize measurements of heat flux from the corium surface and consequently the ingots that were formed were not of optimal thickness for the strength measurements. For the quench tests, a minimum corium depth of 150 mm was deemed necessary to obtain a satisfactory heat flux measurement. However, 150 mm is too much for optimal load testing and so the ingots were sectioned (cut in the radial direction) to increase their aspect ratio (diameter/thickness) to make them more suitable for load testing. Unfortunately, the cutting process is laborious and involves much handling of the ingot and therefore decreases the certainty that the mechanical strength of the sections is close to that of the original ingot. This uncertainty would be eliminated if the ingots produced by the quench tests could be tested without having to cut them. SSWICS-9 & 10, in contrast to previous tests, are designed to optimize the ingot for load testing. A reduced amount of corium will be used in the quench test to produce a thinner ingot. The ingot will then be load tested without sectioning. This report details the results of the SSWICS-10 quench test.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

OECD MCCI Project: Small-Scale Water Ingression and Crust Strength Tests (SSWICS), SSWICS-9 Test Data Report (Thermal Hydraulic Results)

The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These experiments provided unique, and for the most part repeatable, indications of heat transfer mechanisms that could provide long term debris cooling. However, the results did not demonstrate definitively that a melt would always be completely quenched. This was due at least partially to the fact that the crust anchored to the test section sidewalls in every test, which led to melt/crust separation, even at the largest test section lateral span of 1.2 m. This decoupling is not expected for a typical reactor cavity where the lateral span is much larger, ~5-6 m. Instead, the crust is expected to fracture under the weight of the coolant and the crust itself so that coolant contact with the melt is maintained. However, because of a lack of knowledge of the strength of the crust, one cannot be certain that it would actually fracture under such circumstances. As part of the MCCI-1 and MCCI-2 programs, a series of separate-effects experiments has been conducted to measure corium quench rates and crust strength to investigate the various debris cooling mechanisms identified in the MACE program. Each quench test involved cooling a molten mass of UO 2 , ZrO 2 , and concrete constituents, which produced a corium ingot that was later load tested to determine its mechanical strength. The quench tests were designed to optimize measurements of heat flux from the corium surface and consequently the ingots that were formed were not of optimal thickness for the strength measurements. For the quench tests, a minimum corium depth of 150 mm was deemed necessary to obtain a satisfactory heat flux measurement. However, 150 mm is too much for optimal load testing and so the ingots were sectioned (cut in the radial direction) to increase their aspect ratio (diameter/thickness) to make them more suitable for load testing. Unfortunately, the cutting process is laborious and involves much handling of the ingot and therefore decreases the certainty that the mechanical strength of the sections is close to that of the original ingot. This uncertainty would be eliminated if the ingots produced by the quench tests could be tested without having to cut them. SSWICS-9 & 10, in contrast to previous tests, are designed to optimize the ingot for load testing. A reduced amount of corium will be used in the quench test to produce a thinner ingot. The ingot will then be load tested without sectioning. This report details the results of the SSWICS-9 quench test.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tiltrotor Aeroacoustic Code (TRAC) Prediction Assessment and Initial Comparisons with Tram Test Data

A prediction sensitivity assessment to inputs and blade modeling is presented for the TiltRotor Aeroacoustic Code (TRAC). For this study, the non-CFD prediction system option in TRAC is used. Here, the comprehensive rotorcraft code, CAMRAD.Mod1, coupled with the high-resolution sectional loads code HIRES, predicts unsteady blade loads to be used in the noise prediction code WOPWOP. The sensitivity of the predicted blade motions, blade airloads, wake geometry, and acoustics is examined with respect to rotor rpm, blade twist and chord, and to blade dynamic modeling. To accomplish this assessment, an interim input-deck for the TRAM test model and an input-deck for a reference test model are utilized in both rigid and elastic modes. Both of these test models are regarded as near scale models of the V-22 proprotor (tiltrotor). With basic TRAC sensitivities established, initial TRAC predictions are compared to results of an extensive test of an isolated model proprotor. The test was that of the TiltRotor Aeroacoustic Model (TRAM) conducted in the Duits-Nederlandse Windtunnel (DNW). Predictions are compared to measured noise for the proprotor operating over an extensive range of conditions. The variation of predictions demonstrates the great care that must be taken in defining the blade motion. However, even with this variability, the predictions using the different blade modeling successfully capture (bracket) the levels and trends of the noise for conditions ranging from descent to ascent.

Burley, Casey L.↗

Tiltrotor Aeroacoustic Code (TRAC) Prediction Assessment and Initial Comparisons With TRAM Test Data

A prediction sensitivity assessment to inputs and blade modeling is presented for the TiltRotor Aeroacoustic Code (TRAC). For this study, the non-CFD prediction system option in TRAC is used. Here, the comprehensive rotorcraft code, CAMRAD.Mod 1, coupled with the high-resolution sectional loads code HIRES, predicts unsteady blade loads to be used in the noise prediction code WOPWOP. The sensitivity of the predicted blade motions, blade airloads, wake geometry, and acoustics is examined with respect to rotor rpm, blade twist and chord, and to blade dynamic modeling. To accomplish this assessment. an interim input-deck for the TRAM test model and an input-deck for a reference test model are utilized in both rigid and elastic modes. Both of these test models are regarded as near scale models of the V-22 proprotor (tiltrotor). With basic TRAC sensitivities established, initial TRAC predictions are compared to results of an extensive test of an isolated model proprotor. The test was that of the TiltRotor Aeroacoustic Model (TRAM) conducted in the Duits-Nederlandse Windtunnel (DNW). Predictions are compared to measured noise for the proprotor operating over an extensive range of conditions. The variation of predictions demonstrates the great care that must be taken in defining the blade motion. However, even with this variability, the predictions using the different blade modeling successfully capture (bracket) the levels and trends of the noise for conditions ranging from descent to ascent.

Burley, Casey L.↗

Structural Damage Prediction and Analysis for Hypervelocity Impact. UDRI Light Gas Gun Test Data Summaries

The HEX bumper was originally developed for use with the Defensive Shields Demonstration (DSD) Program. The University of Dayton Research Institute was a subcontractor to the Martin Marietta Astronautics Group in Denver Colorado at the time the HEX bumper was designed for use on the DSD Program. The design originated at the University and was essentially made available to interested parties. All HEX bumpers used in the DSD Program were fabricated at the University by rolling sheet stock through a special set of rollers. Two pieces of 3003-H14 aluminum sheet were rolled to produce the bumpers evaluated in Shots 4-1302 and 4-1304. A brief summary of the results of these tests is given in below. Contact prints of the multiple-exposure, orthogonal view radiographs of the debris clouds produced by the tests are attached. A sketch of the HEX bumper design is also attached.

Source record↗

Estimation of parameters involved in high angle-of-attack aerodynamic theory using spin flight test data

The difficulty in applying parameter estimation techniques to spinning airplanes is due in part to the unwieldy number of possible combinations of terms in the equations of motion, when the model structure is unknown. The combination of high angle of attack and high rotation rate results in aerodynamic functions which are quite complex. For wing dominated configurations it is advantageous to use aerodynamic theory to generate the model structure. In this way, the number of unknown parameters is reduced and the model accuracy may be increased. Under conditions for which the theory is inadequate, however, model accuracy may be reduced. Strip theory, for example, is incapable of predicting autorotative rolling moments indicated by wind tunnel tests at angles of attack exceeding 40 degrees. An improved aerodynamic theory would be necessary to successfully apply the technique advanced for such regions.

Taylor, L. W., Jr.↗

Development of an integrated aeroservoelastic analysis program and correlation with test data

The details and results are presented of the general-purpose finite element STructural Analysis RoutineS (STARS) to perform a complete linear aeroelastic and aeroservoelastic analysis. The earlier version of the STARS computer program enabled effective finite element modeling as well as static, vibration, buckling, and dynamic response of damped and undamped systems, including those with pre-stressed and spinning structures. Additions to the STARS program include aeroelastic modeling for flutter and divergence solutions, and hybrid control system augmentation for aeroservoelastic analysis. Numerical results of the X-29A aircraft pertaining to vibration, flutter-divergence, and open- and closed-loop aeroservoelastic controls analysis are compared to ground vibration, wind-tunnel, and flight-test results. The open- and closed-loop aeroservoelastic control analyses are based on a hybrid formulation representing the interaction of structural, aerodynamic, and flight-control dynamics.

Gupta, K. K.↗

Data Testing of Polyethylene Thermal Scattering Law with New Thermal Epithermal eXperiments (TEX) Plutonium Baseline Benchmark, PU-MET-MIXED-002

Five plutonium baseline experiments completed in September of 2018 from the Thermal Epithermal eXperiments (TEX) program have been accepted by the International Criticality Safety Benchmark Evaluation Project as PU-MET-MIXED-002 and will be included in the 2020 version of the handbook. The experiments were made up of stacked layers of plutonium Zero Power Physics Reactor (ZPPR) plates moderated by polyethylene (PE, chemical formula C2H4) to varying degrees to create configurations with five different neutron spectra, including one fast configuration, one thermal configuration, and three mixed configurations. Calculations of the benchmark show overprediction of k eff when using the most recent release of the Evaluated Nuclear Data File Version B (ENDF/B) library release (VIII.0) cross sections, particularly when compared to the previous ENDF/B-VII.1 results. One potential source of overprediction was hypothesized to be the new Molecular Dynamics (MD) generated PE Thermal Scattering Law (TSL). The overprediction was shown via calculation to not be caused by the new ENDF/B-VIII.0 thermal scattering law, and in fact the overprediction was mitigated by the new PE TSL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of the Simple Safe Site Selection (S4) Hazard Detection Algorithm Using Helicopter Field Test Data

Small scale terrain hazards, such as rocks, slopes, and craters, can pose significant risk to landing spacecraft and rover or payload deployment. Onboard Hazard Detection and Avoidance (HDA) systems scan and analyze the landing area for these hazards in real time during descent, and divert the spacecraft to the safest touchdown site. The computationally efficient Simple Safe Site Selection (S4) algorithm combined with a flash LIDAR is an HDA system geared towards small robotic spacecraft. Rather than creating and analyzing a digital elevation map (DEM) from potentially many overlapping range images, S4 operates directly on a single flash LIDAR image. Extending prior work that has analyzed S4 performance for Mars landing using extensive simulations, this paper evaluates S4 performance using actual flash LIDAR images of an artificial hazard field acquired during a 2014 helicopter field test in Death Valley, CA. In particular, we describe LIDAR characterization and calibration, creation of ground truth elevation and safety maps, creation of ground truth sensor poses, actual S4 algorithm processing, and performance analysis. The results show that the safety cost images produced by S4 are remarkably close to the ground truth safety map (computed offline by an HDA algorithm developed under the Autonomous Landing and Hazard Avoidance (ALHAT) project) at significantly reduced computational cost, confirming S4 as a viable candidate algorithm for onboard spacecraft HDA.

Luna, Michael E.↗

Neutralizer Hollow Cathode Simulations and Comparisons with Ground Test Data

The fidelity of electric propulsion physics-based models depends largely on the validity of their predictions over a range of operating conditions and geometries. In general, increased complexity of the physics requires more extensive comparisons with laboratory data to identify the region(s) that lie outside the validity of the model assumptions and to quantify the uncertainties within its range of application. This paper presents numerical simulations of neutralizer hollow cathodes at various operating conditions and orifice sizes. The simulations were performed using a two-dimensional axisymmetric model that solves numerically a relatively extensive system of conservation laws for the partially ionized gas in these devices. A summary of the comparisons between simulation results and Langmuir probe measurements is provided. The model has also been employed to provide insight into recent ground test observations of the neutralizer cathode in NEXT. It is found that a likely cause of the observed keeper voltage drop is cathode orifice erosion. However, due to the small magnitude of this change, is approx. 0.5 V (less than 5% of the beginning-of-life value) over 10 khrs, and in light of the large uncertainties of the cathode material sputtering yield at low ion energies, other causes cannot be excluded. Preliminary simulations to understand transition to plume mode suggest that in the range of 3-5 sccm the existing 2-D model reproduces fairly well the rise of the keeper voltage in the NEXT neutralizer as observed in the laboratory. At lower flow rates the simulation produces oscillations in the keeper current and voltage that require prohibitively small time-steps to resolve with the existing algorithms.

electric propulsion↗

Dexterity test data contribute to proper glovebox over-glove use

Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes (the glovebox, coupled with an adequate negative pressure gradient, provides primary confinement). The glovebox gloves are the weakest part of this engineering control. The Glovebox Glove Integrity Program, which controls glovebox gloves from procurement to disposal at TA-55, manages this vulnerability. A key element of this program is to consider measures that lower the overall risk of glovebox operations. Proper selection of over-gloves is one of these measures. Line management owning glovebox processes have the responsibility to approve the appropriate personal protective equipment/glovebox glove/over-glove combination. As low as reasonably achievable (ALARA) considerations to prevent unplanned glovebox glove openings must be balanced with glove durability and worker dexterity, both of which affect the final overall risk to the worker. In this study, the causes of unplanned glovebox glove openings, the benefits of over-glove features, the effect of over-gloves on task performance using standard dexterity tests, the pollution prevention benefits, and the recommended over-gloves for a task are presented.

57↗

Dexterity tests data contribute to reduction in leaded glovebox gloves use

Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alphaemitting materials. The spread of radiological contamination on surfaces and airborne contamination and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes. Through an integrated approach, controls have been developed and implemented through an efficient Glovebox Glove Integrity Program (GGJP). A key element of this program is to consider measures that lower the overall risk of glovebox operations. Line management owning glovebox processes through this program make decisions on which type of glovebox gloves (the weakest component of this safety significant system) would perform in these aggressive environments. As Low As Reasonably Achievable (ALARA) considerations must be balanced with glove durability and worker dexterity, both of which affect the final overall risk of the operation. In the past, lead-loaded (leaded) glovebox gloves made from Hypalon(reg.) had been the workhorse of programmatic operations at TA-55. Replacing leaded gloves with unleaded gloves for certain operations would lower the overall risk as well as reduced the amount of mixed TRU waste. This effort contributes to Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost effectiveness, and formality of glovebox operations. In the following report, the pros and cons of wearing leaded glovebox gloves, the effect of leaded gloves versus unleaded gloves on task performance using standard dexterity tests, the justification for switching from leaded to unleaded gloves, and pollution prevention benefits of this dramatic change in the glovebox system are presented.

57↗

Dexterity test data contribute to reduction in leaded glovebox gloves use

Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (T A-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes. Using an integrated approach, controls have been developed and implemented through an efficient Glovebox Glove Integrity Program. A key element of this program is to consider measures that lower the overall risk of glovebox operations. Line management who own glovebox processes through this program make decisions on which type of glovebox gloves (hereafter referred to as gloves), the weakest component of this safety-significant system, would perform best in these aggressive environments. As Low as Reasonably Achievable considerations must be balanced with glove durability and worker dexterity, both of which affect the final overall risk of the operation. In the past, lead-loaded (leaded) gloves made from Hypalon(reg.) were the primary glove for programmatic operations at TA55. Replacing leaded gloves with unleaded gloves for certain operations would lower the overall risk as well as reduce the amount of mixed transuranic waste. This effort contributes to the Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost-effectiveness, and formality of glovebox operations. In this report, the pros and cons of wearing leaded gloves, the effect of leaded gloves versus unleaded gloves on task performance using standard dexterity tests, the justification for switching from leaded to unleaded gloves, and the pollution prevention benefits of this dramatic change in the glovebox system are presented.

42 ENGINEERING↗