Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “techniques: image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Scaling deep learning for material imaging with a pseudo 3D model for domain transfer

The recent introduction of deep learning methods for image processing has greatly advanced the characterization of materials using three-dimensional (3D) X-ray imaging techniques. However, deep learning models often have difficulty performing consistently across images owing to unavoidable variations in imaging conditions, which create inconsistencies even for the same material. As a result, networks must frequently be retrained for new datasets, limiting their applicability and generalization. Thus, it is critical to reduce the variations between images to enable a single model to process multiple datasets. Herein, we introduce P3T-Net, a pseudo-3D domain transfer network that transfers diverse 3D images into a uniform domain before processing using deep learning models. Remarkably, P3T-Net enables the reuse of previously trained networks for processing new images and considerably reduces the computational cost of transferring 3D images across domains. These unique capabilities were demonstrated in the following scenarios: (i) image enhancement of fast scans for geological rock and hydrogen fuel cells, (ii) enhancement of images to match the quality of multi-source imaging for lithium-ion batteries, (iii) accurate segmentation of images captured under different conditions, and (iv) tera-scale 3D transfer (10 11 voxels) on a single GPU. Overall, the proposed approach addresses cross-domain inconsistencies across various materials and conditions, thereby enabling more robust and generalizable deep learning solutions for a wide range of material imaging tasks.

25 ENERGY STORAGE↗

High fidelity ultrasound imaging of concrete structures

As plans are made to extend licenses for the aging fleet of commercial nuclear power plants for periods of sixty years and beyond, research into the long-term integrity of their concrete structures has increased. Ultrasound tomography is a useful tool for nondestructive evaluation of these concrete structures. Typically, pulse-echo measurements are made over a large surface and are processed using a reconstruction algorithm, producing a 3D image of the structure that highlights embedded defects. These measurements are processed using a delay-and-sum algorithm such as the synthetic aperture focusing technique (SAFT). Oak Ridge National Laboratory is developing novel ultrasound model-based image reconstruction (U-MBIR) algorithms to improve the imaging capability of pulse-echo ultrasound array imagers. U-MBIR is an inversion technique that reconstructs the sample under test from the ultrasound measurements by formulating and solving a mathematical optimization problem using two sets of terms: one set ensures that the reconstruction matches measured data based on a model for the physics of beam propagation with the noise in the detector, and another set ensures that the reconstruction has certain properties based on a model for the object being scanned. This paper compares three techniques: SAFT, frequency-banded SAFT (FB-SAFT), and U-MBIR. The U-MBIR method produces higher quality images of the underlying concrete structures compared to the images produced using SAFT and FB-SAFT from the same set of measurements. This paper also illustrates the detection of various defects with higher confidence due to the lower noise and artifact-free U-MBIR images.

Ezell, N Dianne↗

Applying image processing methods to study hydrodynamic characteristics in a rectangular spouted bed

This paper presents systematic image processing methods for investigating hydrodynamic characteristics in a rectangular spouted bed (30.2 mm × 101.6 mm). The objective is to provide a non-intrusive technique to determine the bed expansion ratio, the jet height and the fountain height due to their significant influence on the hydrodynamics of the entire bed. A high-speed video camera is used in the experiment with Geldart D particles as the bed material. After the image acquisition, image denoising, thresholding, logical and mask operations are applied correspondingly for the boundary discrimination, based on which an algorithm has been developed to determine the bed height successfully. With the discriminated boundary, morphological operations viz. erosion and dilation have been used to accurately determine the jet height and the fountain height. The feasibility of the technique is proven through profiles of bed expansion ratio, jet height and fountain height under three initial bed heights (0.0762 m, 0.102 m, and 0.127 m) for two different nozzle sizes (0.0096 m and 0.0127 m). Depending on the determination of the hydrodynamic characteristics, different flow regimes can be distinguished comprehensively through profiles of the bed expansion ratio and bed pressure drop in combination with the standard deviation of jet/fountain height. The proposed flow regime discrimination verifies the feasibility and effectiveness of the image processing methods in assessing the solids behavior in the spouted beds. Results about the variation of the jet height and the fountain height under current operating conditions as determined by the new technique are also discussed.

20 FOSSIL-FUELED POWER PLANTS↗

FIRST IMAGES OF DEBRIS DISKS AROUND TWA 7, TWA 25, HD 35650, AND HD 377

We present the first images of four debris disks observed in scattered light around the young (4–250 Myr old) M dwarfs TWA 7 and TWA 25, the K6 star HD 35650, and the G2 star HD 377. We obtained these images by reprocessing archival Hubble Space Telescope NICMOS coronagraph data with modern post-processing techniques as part of the Archival Legacy Investigation of Circumstellar Environments program. All four disks appear faint and compact compared with other debris disks resolved in scattered light. The disks around TWA 25, HD 35650, and HD 377 appear very inclined, while TWA 7's disk is viewed nearly face-on. The surface brightness of HD 35650's disk is strongly asymmetric. These new detections raise the number of disks resolved in scattered light around M and late-K stars from one (the AU Mic system) to four. This new sample of resolved disks enables comparative studies of heretofore scarce debris disks around low-mass stars relative to solar-type stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Detecting brain tumor in computed tomography images using Markov random fields and fuzzy C-means clustering techniques

Brain tumors, are an abnormal growth of tissues in the brain. They may arise in people of any age. They must be detected early, diagnosed accurately, monitored carefully, and treated effectively in order to optimize patient outcomes regarding both survival and quality of life. Manual segmentation of brain tumors from CT scan images is a challenging and time consuming task. Size and location accurate detection of brain tumor plays a vital role in the successful diagnosis and treatment of tumors. Brain tumor detection is considered a challenging mission in medical image processing. The aim of this paper is to introduce a scheme for tumor detection in CT scan images using two different techniques Hidden Markov Random Fields (HMRF) and Fuzzy C-means (FCM). The proposed method has been developed in this research in order to construct hybrid method between (HMRF) and threshold. These methods have been applied on 4 different patient data sets. The result of comparison among these methods shows that the proposed method gives good results for brain tissue detection, and is more robust and effective compared with (FCM) techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EM reconstruction of dual isotope PET using staggered injections and prompt gamma positron emitters

Purpose: The aim of dual isotope positron emission tomography (DIPET) is to create two separate images of two coinjected PET radiotracers. DIPET shortens the duration of the study, reduces patient discomfort, and produces perfectly coregistered images compared to the case when two radiotracers would be imaged independently (sequential PET studies). Reconstruction of data from such simultaneous acquisition of two PET radiotracers is difficult because positron decay of any isotope creates only 511 keV photons; therefore, the isotopes cannot be differentiated based on the detected energy. Methods: Recently, the authors have proposed a DIPET technique that uses a combination of radiotracer A which is a pure positron emitter (such as{sup 18}F or {sup 11}C) and radiotracer B in which positron decay is accompanied by the emission of a high-energy (HE) prompt gamma (such as {sup 38}K or {sup 60}Cu). Events that are detected as triple coincidences of HE gammas with the corresponding two 511 keV photons allow the authors to identify the lines-of-response (LORs) of isotope B. These LORs are used to separate the two intertwined distributions, using a dedicated image reconstruction algorithm. In this work the authors propose a new version of the DIPET EM-based reconstruction algorithm that allows the authors to include an additional, independent estimate of radiotracer A distribution which may be obtained if radioisotopes are administered using a staggered injections method. In this work the method is tested on simple simulations of static PET acquisitions. Results: The authors’ experiments performed using Monte-Carlo simulations with static acquisitions demonstrate that the combined method provides better results (crosstalk errors decrease by up to 50%) than the positron-gamma DIPET method or staggered injections alone. Conclusions: The authors demonstrate that the authors’ new EM algorithm which combines information from triple coincidences with prompt gammas and staggered injections improves the accuracy of DIPET reconstructions for static acquisitions so they reach almost the benchmark level calculated for perfectly separated tracers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wave Detection and Tracking Within a Rotating Detonation Engine Through Object Detection

As the operational time window of experimental rotating detonation engines (RDEs) is expanded and the technology matures toward integration within gas turbines, monitoring techniques must evolve to offer computationally efficient and highly time-resolved diagnostics. In this study, computer vision object detection methodology that seeks to reduce data processing time and calculate wave velocity within drastically reduced time intervals as compared to traditional high-frame-rate RDE images analysis techniques is proposed. The adapted you-only-look-once object detection network is trained to detect individual detonation waves within single down-axis RDE images. The wave location and rotational direction detected within a frame are tracked through a series of high-speed images to calculate the frame-to-frame wave velocity with the time-step resolution of $\mathrm{20 μs}$ across a series of frames. The analysis of the annotation box size and image linearization effects is presented, demonstrating the lowest frame-to-frame velocity total uncertainty of $\mathrm{±3.8\%}$ and the highest classification speed of 9.5 frames per second using linearized images. Linearized images “unwrap” the RDE annulus pixel region to a reduced image size. Here, this new method offers great reductions in data processing times and unsteady detonation behavior insight at intervals more comparable to the timescales of detonation wave interactions via the application of machine learning to experimental RDE data.

33 ADVANCED PROPULSION SYSTEMS↗

Higher-Order Optical Modes and Nanostructures for Detection and Imaging Applications

Raman spectroscopy offers a label-free, chemically specific, method of detecting molecules; however, the low cross-section attendant to this scattering process has hampered trace detection. The realization that scattering is enhanced at a metallic surface has enabled new techniques for spectroscopic and imaging analysis.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

X-ray characterization of low-thermal conductivity thin-film materials.

X-ray diffraction and imaging techniques at the Advanced Photon Source (APS) have been used to characterize PbSe/MoSe{sub 2} and PbSe/WSe{sub 2} thin films and multilayers. Diffraction measurements with area detectors were made to demonstrate the nanoscale coherence size of the layers both in-plane and perpendicular to the surface. Higher-resolution diffraction measurements that exploit the tunability of synchrotron radiation for anomalous scattering contrast have been used to accurately determine layer spacings in these multilayers. We also discuss opportunities in other new and emerging x-ray techniques, such as time-resolved studies during growth or processing, and present x-ray imaging capabilities that can be used to investigate thermoelectric thin-film materials.

43 PARTICLE ACCELERATORS↗

A laser powder bed fusion system for operando synchrotron x-ray imaging and correlative diagnostic experiments at the Stanford Synchrotron Radiation Lightsource

Laser powder bed fusion (LPBF) is a highly dynamic multi-physics process used for the additive manufacturing (AM) of metal components. Improving process understanding and validating predictive computational models require high-fidelity diagnostics capable of capturing data in challenging environments. Synchrotron x-ray techniques play a vital role in the validation process as they are the only in situ diagnostic capable of imaging sub-surface melt pool dynamics and microstructure evolution during LPBF-AM. In this article, a laboratory scale system designed to mimic LPBF process conditions while operating at a synchrotron facility is described. The system is implemented with process accurate atmospheric conditions, including an air knife for active vapor plume removal. Significantly, the chamber also incorporates a diagnostic sensor suite that monitors emitted optical, acoustic, and electronic signals during laser processing with coincident x-ray imaging. The addition of the sensor suite enables validation of these industrially compatible single point sensors by detecting pore formation and spatter events and directly correlating the events with changes in the detected signal. Experiments in the Ti–6Al–4V alloy performed at the Stanford Synchrotron Radiation Lightsource using the system are detailed with sufficient sampling rates to probe melt pool dynamics. X-ray imaging captures melt pool dynamics at frame rates of 20 kHz with a 2 µm pixel resolution, and the coincident diagnostic sensor data are recorded at 470 kHz. Furthermore, this work shows that the current system enables the in situ detection of defects during the LPBF process and permits direct correlation of diagnostic signatures at the exact time of defect formation.

36 MATERIALS SCIENCE↗

Characterization of complex thermal barrier deposits pore microstructures by a combination of imaging, scattering and intrusion techniques.

Complexity, wide size ranges, and anisotropy are attributes that can describe porous microstructures of thermally sprayed deposits, which present especially difficult challenges for characterization techniques. A number of different methods have been utilized and found to be useful while having significant limitations. Therefore, scientists and engineers need to understand the advantages, limitations, and disadvantages of each technique. This very short review attempts to present a wide range of characterization tools - from frequently employed optical and scanning electron imaging techniques, through intrusion porosimetry, to lesser-used x-ray and neutron imaging and scattering techniques. It will be shown that no technique in itself is sufficient and that a properly selected combination of techniques is necessary to get a sufficiently complex characterization method. A really powerful and capable characterization protocol may need to combine fast and accessible ('in-house') tools with sparingly applied advanced scattering and imaging techniques. Such a combination of techniques can then be utilized to research the processing-microstructure-properties relationships as well as to provide sufficient data for development of successful models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermodynamics of order and randomness in dopant distributions inferred from atomically resolved imaging

Abstract Exploration of structure-property relationships as a function of dopant concentration is commonly based on mean field theories for solid solutions. However, such theories that work well for semiconductors tend to fail in materials with strong correlations, either in electronic behavior or chemical segregation. In these cases, the details of atomic arrangements are generally not explored and analyzed. The knowledge of the generative physics and chemistry of the material can obviate this problem, since defect configuration libraries as stochastic representation of atomic level structures can be generated, or parameters of mesoscopic thermodynamic models can be derived. To obtain such information for improved predictions, we use data from atomically resolved microscopic images that visualize complex structural correlations within the system and translate them into statistical mechanical models of structure formation. Given the significant uncertainties about the microscopic aspects of the material’s processing history along with the limited number of available images, we combine model optimization techniques with the principles of statistical hypothesis testing. We demonstrate the approach on data from a series of atomically-resolved scanning transmission electron microscopy images of Mo x Re 1- x S 2 at varying ratios of Mo/Re stoichiometries, for which we propose an effective interaction model that is then used to generate atomic configurations and make testable predictions at a range of concentrations and formation temperatures.

25 ENERGY STORAGE↗

Tomographic analysis of tangential viewing cameras (invited)

Many tokamaks now use visible light cameras to observe plasma-wall interactions and integrated line emission. The DIII-D coherence imaging spectroscopy diagnostic cameras image interferograms that encode line integrated velocity. By modeling the 2D camera image pixels as line of sight integrals through an axisymmetric discrete grid, it is possible to do tomographic analysis to determine the local plasma line emissivity and parallel velocity. Approaches to solve the inverse problem posed by these tangential viewing cameras are presented. The inversion begins with calculation of the sparse response matrix that encompasses all the geometry and diagnostic information and reduces the process of image formation to a sparse matrix-vector multiply. Our report includes techniques for determining the detailed geometry of the camera views and methods for handling physical quantities that vary spatially. Additionally, the size of the response matrix has driven the development of capability to distribute the coarse parallel calculation across a heterogeneous cluster of computers on the Energy Sciences Network. Iterative techniques are then used to solve the sparse matrix-vector linear system

47 OTHER INSTRUMENTATION↗

Data Archive and Portal (DAP) Platform for Solid Phase Processing Technologies

The scale and speed of data generated by modern scientific experiments have constantly challenged the research community to store, curate, manage and optimally use it to drive scientific discoveries. In this work, we have developed a data archive and portal (DAP) platform including analytics capabilities to collect, curate, and manage data and metadata stream for solid phase processing (SPP) techniques. We successfully hosted around ~347K files of data related to processing parameters, microscopic images, and spectroscopic data related to solid phase processing. The DAP platform for SPP will establish an enduring capability to support machine learning and grow collaboration at the intersection of materials science and data science.

36 MATERIALS SCIENCE↗

ERRATUM: “Automated Transient Identification in the Dark Energy Survey” (2015, AJ, 150, 82)

Here, we describe an algorithm for identifying point-source transients and moving objects on reference-subtracted optical images containing artifacts of processing and instrumentation. The algorithm makes use of the supervised machine learning technique known as Random Forest. We present results from its use in the Dark Energy Survey Supernova program (DES-SN), where it was trained using a sample of 898,963 signal and background events generated by the transient detection pipeline. After reprocessing the data collected during the first DES-SN observing season (2013 September through 2014 February) using the algorithm, the number of transient candidates eligible for human scanning decreased by a factor of 13.4, while only 1.0% of the artificial Type Ia supernovae (SNe) injected into search images to monitor survey efficiency were lost, most of which were very faint events. Here we characterize the algorithm's performance in detail, and we discuss how it can inform pipeline design decisions for future time-domain imaging surveys, such as the Large Synoptic Survey Telescope and the Zwicky Transient Facility. An implementation of the algorithm and the training data used in this paper are available at at http://portal.nersc.gov/project/dessn/autoscan.

79 ASTRONOMY AND ASTROPHYSICS↗

Source complexity of the 2015 Mw 7.9 Bonin earthquake

The 30 May 2015 Mw 7.9 Bonin earthquake, one of the largest and deepest earthquakes ever recorded by modern seismology, provides a unique opportunity to study the source process and physical mechanisms of deep-focus earthquakes. We develop a novel back-projection technique that allows source imaging in full three-dimensional space with high depth resolution. Our results indicate an initial SW-NE bilateral source propagation followed by a northwest source extension. The multiple-source inversion reveals a two-step source process with propagating directions near-perpendicular to each other, consistent with the 3D back-projection result. The spatial distribution and focal mechanisms of the sub-events cannot be modeled by a single planar rupture, which may display a curved rupture plane or sub-events crossing multiple fault interfaces. Thus, the complex source process can be best explained by stress or structure heterogeneity within the deep slab.

58 GEOSCIENCES↗

Imaging doped silicon test structures using low energy electron microscopy.

This document is the final SAND Report for the LDRD Project 105877 - 'Novel Diagnostic for Advanced Measurements of Semiconductor Devices Exposed to Adverse Environments' - funded through the Nanoscience to Microsystems investment area. Along with the continuous decrease in the feature size of semiconductor device structures comes a growing need for inspection tools with high spatial resolution and high sample throughput. Ideally, such tools should be able to characterize both the surface morphology and local conductivity associated with the structures. The imaging capabilities and wide availability of scanning electron microscopes (SEMs) make them an obvious choice for imaging device structures. Dopant contrast from pn junctions using secondary electrons in the SEM was first reported in 1967 and more recently starting in the mid-1990s. However, the serial acquisition process associated with scanning techniques places limits on the sample throughput. Significantly improved throughput is possible with the use of a parallel imaging scheme such as that found in photoelectron emission microscopy (PEEM) and low energy electron microscopy (LEEM). The application of PEEM and LEEM to device structures relies on contrast mechanisms that distinguish differences in dopant type and concentration. Interestingly, one of the first applications of PEEM was a study of the doping of semiconductors, which showed that the PEEM contrast was very sensitive to the doping level and that dopant concentrations as low as 10{sup 16} cm{sup -3} could be detected. More recent PEEM investigations of Schottky contacts were reported in the late 1990s by Giesen et al., followed by a series of papers in the early 2000s addressing doping contrast in PEEM by Ballarotto and co-workers and Frank and co-workers. In contrast to PEEM, comparatively little has been done to identify contrast mechanisms and assess the capabilities of LEEM for imaging semiconductor device strictures. The one exception is the work of Mankos et al., who evaluated the impact of high-throughput requirements on the LEEM designs and demonstrated new applications of imaging modes with a tilted electron beam. To assess its potential as a semiconductor device imaging tool and to identify contrast mechanisms, we used LEEM to investigate doped Si test structures. In section 2, Imaging Oxide-Covered Doped Si Structures Using LEEM, we show that the LEEM technique is able to provide reasonably high contrast images across lateral pn junctions. The observed contrast is attributed to a work function difference ({Delta}{phi}) between the p- and n-type regions. However, because the doped regions were buried under a thermal oxide ({approx}3.5 nm thick), e-beam charging during imaging prevented quantitative measurements of {Delta}{phi}. As part of this project, we also investigated a series of similar test structures in which the thermal oxide was removed by a chemical etch. With the oxide removed, we obtained intensity-versus-voltage (I-V) curves through the transition from mirror to LEEM mode and determined the relative positions of the vacuum cutoffs for the differently doped regions. Although the details are not discussed in this report, the relative position in voltage of the vacuum cutoffs are a direct measure of the work function difference ({Delta}{phi}) between the p- and n-doped regions.

36 MATERIALS SCIENCE↗