Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systems testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

MWPC prototyping and performance test for the STAR inner TPC upgrade

A new prototype of STAR inner Time Projection Chamber (iTPC) MWPC sector has been fabricated and tested in an X-ray test system. The wire chamber built at Shandong University has a wire tension precision better than 6% and wire pitch precision better than 10 μm. The gas gain uniformity and energy resolution are measured to be better than 1% (RMS) and 20% (FWHM), respectively, using an 55 Fe X-ray source. The iTPC upgrade project is to replace all 24 STAR TPC inner sectors as a crucial detector upgrade for the RHIC beam energy scan phase II program. Furthermore, the test results show that the constructed iTPC prototype meets all project requirements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On assurance testing for repairable systems

In this work, we consider assurance testing for repairable systems when supplementary information is available in addition to the data collected in the assurance test. The supplementary information is incorporated using a Bayesian inferential framework. Assurance testing is considered for both a homogeneous Poisson process and a nonhomogenous Poisson process and is illustrated with examples.

42 ENGINEERING↗

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (↗

SAM Software Quality Assurance Plan Implementation and NQA-1 Assessment

The System Analysis Module (SAM) is an advanced and modern system analysis tool being developed at Argonne National Laboratory under the U.S. DOE Office of Nuclear Energy’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. As a modern-day software, SAM development included efforts to follow best practices in software development. These best practices include version control using git, independent reviews of development activities, and detailed descriptions of developments and bug fixes using the GitLab issue and merge request system. In Fiscal Year 2023 (FY23), the SAM development team set out to formalize a Software Quality Assurance (SQA) program that allowed industry partners to credit the informal steps being taken by the SAM development team to ensure the quality of the software. As part of formalizing an SQA program, a SQA Plan (SQAP) was developed, implemented, and assessed. The SAM SQAP targets compliance with NQA-1-2008/2009 Addenda. The SQAP builds on the MOOSE SQAP and the Argonne SSQAPP while accounting for the needs of the multi-organization SAM development team. Modifications to the SAM repository structure, including a new testing system, updated test cases, and the development of an internal website, facilitate the implementation of the SAM SQAP. The initial assessment of the SAM SQAP indicated that the SAM SQAP was adequately and effectively implemented and additional work was required to improve the compliance of the SAM SQAP with NQA-1 2008/2009 Addenda. Several improvements to the SQAP have already been drafted to address these assessments and future work is planned to further improve the SAM SQAP in support of end-user needs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Commissioning of SRF Cavity Analyzer System

Research and development in Superconducting Radio Frequency (SRF) cavities manufacturing, surface treatment, preparation, and doping techniques for the improvement of cavities performance necessitate reliable cavities’ intrinsic quality factor measurement with accurate and repeatable results. Fermilab Vertical Test Stand facility (VTS) performs ~270 cavities tests per year, including R&D cavities as well as production cavities at each step of their preparation for the placement in accelerator’s cryomodules. Current Fermilab VTS testing system is based on the scalar approach of power measurement, which neglects potential error factors of the RF networks with distributed parameters, hence the assessed measurement errors of such a system might be slightly underestimated. Alternative approach, utilizing a vector measurement (amplitude and phase) of RF signals in the setup with a cavity as a device under test, promises an enhanced accuracy and results traceability. New cavity an alyser system based on this approach (Vector VTS) was developed by D. Frolov et al. and currently undergoes a commissioning process. Basic underlying principles of the system will be presented with the methods of quality factor extraction from S-parameters measurement of multiport cavities and brief error analysis will be discussed. The system architecture will be shown with main components parameters and ensuing testing capabilities. Multiple tests results will be discussed with a cross-check comparison of the results obtained with a conventional testing method. System advantages such as automated calibration process and additional features as a built- in microphonics measurement capability will be presented.

Netepenko, A.↗

Evaluation Of Automated Low-Field Nuclear Magnetic Resonance (NMR) Relaxometry For Analysis Of Silicone Polymers

Screening studies and Design of Experiments (DoE) were performed to evaluate measurement variation of a new, non-destructive Nuclear Magnetic Resonance (NMR) test system designed to assess age-induced degradation of Outer Pressure Pads (OPP). The test method and results from 54,275 measurements are described. A reduction in measurement error was obtained after metal support struts were replaced with plastic support struts adjacent to the front position of the test chamber. However, remaining interference and a lack of detecting any age-related degradation prevent the use of the NMR system as a non-destructive surveillance test for OPPs. A cursory evaluation of the system with cellular silicone samples obtained more uniform results with increased error as measurements approached the sample’s edge.

36 MATERIALS SCIENCE↗

Code Benchmark of the HTTF Pressurized Conduction Cooldown Test Using SAM

The High Temperature Test Facility (HTTF) at Oregon State University is an integral system test facility to simulate postulated reactor transients of prismatic high-temperature gas-cooled reactors(HTGRs). A series of test campaigns was launched, providing abundant test data that could be used to benchmark reactor system analysis codes like the System Analysis Module (SAM). In this study, a SAM model of the facility is developed based on the two-dimensional (2D) ring model approach. All components including the ceramic matrix, graphite heaters, helium coolant channels, core barrel, upcomer, pressure vessel, and reactor cavity cooling system are modeled as concentric cylindrical rings. The model is used to simulate one of the benchmark problems-Pressurized Conduction Cooldown (PCC)-within the scope of the Organisation for Economic Co-operation and Development Nuclear Energy Agency International HTTF Benchmark. The simulations consist of two parts. In the first part, operating and boundary conditions as well as thermophysical properties of materials are specified for the benchmark problem. In this work, results from the first part will be used in code-to-code comparison. In the second part, the SAM model is used to simulate Test PG-27, which is the first PCC test carried out in the HTTF, with only two of the ten heater banks activated. The results in the second part are used for code-to-data comparison. Because the helium coolant flow rate is not measured in this facility, it is estimated using the input power and inlet/outlet coolant temperatures. Additionally, radial heat flow in the ceramic blocks is complicated by hundreds of cylindrical coolant channels and heater rods embedded in them. As such, it is necessary to deduce an effective thermal conductivity for the ceramic to analyze the core thermal behavior. SAM predictions of the helium coolant and ceramic temperatures are compared with test data measured in three equivalent sectors. Overall, the SAM results agree reasonably well with test data within the variation of data among the three sectors, which demonstrates SAM's capability in capturing transient effects in HTGR using the simplified 2D ring model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ADMS Test Bed

This presentation provides an overview of the Advanced Distribution Management System test bed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NREL’s Controllable Grid Interface Saves Time and Resources, Improves Reliability of Renewable Energy Technologies; NREL (National Renewable Energy Laboratory)

The National Renewable Energy Laboratory's (NREL) controllable grid interface (CGI) test system at the National Wind Technology Center (NWTC) is one of two user facilities at NREL capable of testing and analyzing the integration of megawatt-scale renewable energy systems. The CGI specializes in testing of multimegawatt-scale wind and photovoltaic (PV) technologies as well as energy storage devices, transformers, control and protection equipment at medium-voltage levels, allowing the determination of the grid impacts of the tested technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution System Voltage Regulation by Distributed Energy Resources

This paper proposes a control method to regulate voltages in 3 phase unbalanced electrical distribution systems. A constrained optimization problem to minimize voltage deviations and maximize distributed energy resource (DER) active power output is solved by harmony search algorithm. IEEE 13 Bus Distribution Test System was modified to test three different cases: a) only voltage regulator controlled system b) only DER controlled system and c) both voltage regulator and DER controlled system. The simulation results show that systems with both voltage regulators and DER control provide better voltage profile.

Distributed energy resources↗

Signature analysis of high-throughput transcriptomics screening data for mechanistic inference and chemical grouping

Abstract High-throughput transcriptomics (HTTr) uses gene expression profiling to characterize the biological activity of chemicals in in vitro cell-based test systems. As an extension of a previous study testing 44 chemicals, HTTr was used to screen an additional 1,751 unique chemicals from the EPA’s ToxCast collection in MCF7 cells using 8 concentrations and an exposure duration of 6 h. We hypothesized that concentration-response modeling of signature scores could be used to identify putative molecular targets and cluster chemicals with similar bioactivity. Clustering and enrichment analyses were conducted based on signature catalog annotations and ToxPrint chemotypes to facilitate molecular target prediction and grouping of chemicals with similar bioactivity profiles. Enrichment analysis based on signature catalog annotation identified known mechanisms of action (MeOAs) associated with well-studied chemicals and generated putative MeOAs for other active chemicals. Chemicals with predicted MeOAs included those targeting estrogen receptor (ER), glucocorticoid receptor (GR), retinoic acid receptor (RAR), the NRF2/KEAP/ARE pathway, AP-1 activation, and others. Using reference chemicals for ER modulation, the study demonstrated that HTTr in MCF7 cells was able to stratify chemicals in terms of agonist potency, distinguish ER agonists from antagonists, and cluster chemicals with similar activities as predicted by the ToxCast ER Pathway model. Uniform manifold approximation and projection (UMAP) embedding of signature-level results identified novel ER modulators with no ToxCast ER Pathway model predictions. Finally, UMAP combined with ToxPrint chemotype enrichment was used to explore the biological activity of structurally related chemicals. The study demonstrates that HTTr can be used to inform chemical risk assessment by determining in vitro points of departure, predicting chemicals’ MeOA and grouping chemicals with similar bioactivity profiles.

Toxicology↗

FY2009 R&D Plan: Neutrino Factory and Muon Collider Collaboration

A Neutrino Factory or a Muon Collider represents a potential future direction for the U.S. high-energy physics community. These challenging machines make use of stored beams of muons—a particle that is difficult to produce and has a short lifetime of only 2.2 μs at rest. The U.S. Neutrino Factory and Muon Collider Collaboration (NFMCC), comprising some 130 scientists from national laboratories, universities, and SBIR companies, has been carrying out a focused R&D program aimed at: producing conceptual designs for such facilities, developing and testing the required machine components, and carrying out system tests of a few key subsystems of such facilities. In this document we summarize the R&D progress made during FY2008 and indicate the plans and milestones for FY2009. Because our University groups (IIT, Princeton, UC Berkeley, UCLA, UC-Riverside, and U-Mississippi) all turn in detailed annual progress reports and summaries, and our SBIR partners (Muons, Inc., PBL, and Tech-X) write proposals that are reviewed by DOE, this document will cover only the status of the national laboratory programs (including the “sponsoring laboratories, BNL, FNAL, and LBNL, and the other laboratories with whom we collaborate, ANL, Jlab, and ORNL).

43 PARTICLE ACCELERATORS↗

Evaluation of a streaming readout solution for Jefferson Lab experiments

Jefferson Lab (JLab) operates the CEBAF accelerator that provides a high energy (up to 12 GeV) and high current (up to 150 µA) polarized electron beam for fixed target experiments. JLab's mission is to provide substantial progress in understanding the Quantum Chromo Dynamics (QCD), the current theory of the spectrum and the dynamics of hadronic matter. Given the broad scientific program a general-purpose detector, CLAS12, has been designed and constructed. Such a detector requires a sophisticated trigger and current experiments use an on-line FPGA-based system that relies upon custom firmware and electronics both of which are difficult reconfigure from one experiment to the next. To overcome these challenges transitioning to a streaming readout has been proposed since it would allow a more flexible, easier to debug, software trigger to be developed. To facilitate this JLab is gaining experience with streaming readout systems and is actively working to design and test a streaming data acquisition architecture. Significant work has already been done to make existing front-end electronics compatible with operation in streaming mode. Software-wise, much work remains to be done but an existing framework, TriDAS, which was developed for underwater neutrino telescopes can, in principle, be used with the existing JLab hardware. A test stand is already in place in the INDRA DAQ development lab at JLab. This paper will present the development of this TriDAS based test system and it?s operation in-beam using parts of the CLAS12 detector to evaluate streaming readout for a large general purpose detector.

Battaglieri, Marco↗

An Integrated Gate Driver in 4H-SiC for Power Converter Applications

A gate driver fabricated in a 2-um 4H silicon carbide (SiC) process is presented. This process was optimized for vertical power MOSFET fabrication but accommodated integration of a few low-voltage device types including N-channel MOSFETs, resistors, and capacitors. The gate driver topology employed incorporates an input level translator, variable power connections, and separate power supply connectivity allowing selection of the output signal drive amplitude. The output stage utilizes a source follower pull-up device that is both overdriven and body source connected to improve rise time behavior. Full characterization of this design driving a SiC power MOSFET is presented including rise and fall times, propagation delays, and power consumption. All parameters were measured to elevated temperatures exceeding 300 C. Details of the custom test system hardware and software utilized for gate driver testing are also provided.

Ericson, Milton Nance↗

Caustic-Side Solvent Extraction Full-Scale Test

A Full-Scale Test (FST) program was performed by Parsons and its team members General Atomics and Energy Solutions to assess the performance of full-scale centrifugal contactors specified for the Department of Energy Salt Waste Processing Facility (SWPF). The SWPF, to be located at the Savannah River Site (SRS) in Aiken, South Carolina, will remove highly radioactive waste constituents, principally actinides, strontium (Sr), and cesium (Cs) radionuclides, from salt waste solutions currently stored in SRS high-level waste tanks. Caustic-side Solvent Extraction (CSSX) removes Cs from waste feed that has been treated upstream to remove actinides and Sr. CSSX uses a custom solvent to extract Cs from the salt solution in a series of single stage centrifugal contactors. The test system comprised (a) eleven 25.4 cm (10'') full-scale contactors (versus 36 in SWPF) for the extraction, scrub, strip, and wash stages; (b) two solvent recovery coalescers; and (c) the associated hardware and control system, packaged in four skid mounted modules. This paper describes the results of tests performed to define both hydraulic performance parameters (maximum hydraulic capacity and phase carryover) and solvent extraction performance parameters (Cs mass transfer efficiencies) using simulated SWPF waste and actual CSSX solvent. The test results confirmed key design features of the CSSX process and, as a consequence, the use of CSSX in the SWPF. In conclusion: Total throughput was initially limited to 85% of maximum flow during FST. Minor system modifications performed prior to mass transfer testing series resulted in the realization of 100% throughput. The 100% flow equates to slightly more than 35.6 x 10{sup 6} L/yr (9.4 Mgal/yr) of waste processed in SWPF which is anticipated to be the peak plant throughput. To achieve the best hydraulic performance in extraction, it is recommended that the extraction contactors be operated at the highest reasonable speed possible (>2100 rpm). Vibration, hardware limitations, bearing life, and other factors should be considered prior to final selection of extraction contactor speeds in SWPF. In strip (also scrub and wash) aqueous carryover decreased and organic carryover increased as the rotor speeds increased. It is recommended that the strip, scrub, and wash contactors be operated at intermediate speeds (between 1500 and 2100 rpm) to achieve a performance compromise between aqueous and organic carryover. Curved-vane bottom plates showed a significant hydraulic performance (aqueous and organic carryover) advantage over straight-vane bottom plates in extraction. There was no significant mass transfer performance advantage for either plate type in extraction. Thus, curved-vane bottom plates in extraction may be the better option for use in SWPF. There was no significant hydraulic performance difference between the plate types in strip. Straight-vanes provided significantly better mass transfer performance in strip compared to curved-vanes. Based solely on mass transfer performance, straight-vane bottom plates in the strip, scrub, and wash contactors are recommended for use in SWPF. Utilizing straight-vanes in the stripping section, the overall SWPF CSSX performance is expected to meet or exceed the target DF of 40,000 with minimum extraction D{sub Cs} of 10. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nuclear Hybrid Energy System Model Stability Testing

A Nuclear Hybrid Energy System (NHES) uses a nuclear reactor as the basic power generation unit, and the power generated is used by multiple customers as combinations of thermal power or electrical power. The definition and architecture of a particular NHES can be adapted based on the needs and opportunities of different localities and markets. For example, locations in need of potable water may be best served by coupling a desalination plant to the NHES. Similarly, a location near oil refineries may have a need for emission-free hydrogen production. Using the flexible, multi-domain capabilities of Modelica, Argonne National Laboratory, Idaho National Laboratory, and Oak Ridge National Laboratory are investigating the dynamics (e.g., thermal hydraulics and electrical generation/consumption) and cost of a hybrid system. This paper examines the NHES work underway, emphasizing the control system developed for individual subsystems and the overall supervisory control system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗