Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

An electro-optic, high-voltage, transient probe

A newly developed electro-optic voltage transducer is described. It is capable of measuring 30 ns rise time, floating or single-ended, 0 to 20 kV transients in a high noise environment such as a fast discharge laser or energetic switch system. The voltage transient is detected by a specially developed resistor in series with a light emitting diode. The light output (proportional to voltage) is transmitted remotely via a fiber-optic cable to a detector and recorder. Typical signals and comparison with commercial probe system signals are described.

Posta, S. J.↗

The Impact on Space Radiation Requirements and Effects on ASIMS

The evolution of highly miniaturized electronic and mechanical systems will be accompanied by new problems and issues regarding the radiation response of these systems in the space environment. In this paper we discuss some of the more prominent radiation problems brought about by miniaturization. For example, autonomous micro-spacecraft will require large amounts of high density memory, most likely in the form of stacked, multichip modules of DRAM's, that must tolerate the radiation environment. However, advanced DRAM's (16 to 256 Mbit) are quite susceptible to radiation, particularly single event effects, and even exhibit new radiation phenomena that were not a problem for older, less dense memory chips. Another important trend in micro-spacecraft electronics is toward the use of low-voltage microelectronic systems that consume less power. However, the reduction in operating voltage also caries with it an increased susceptibility to radiation. In the case of application specific integrated microcircuits (ASIM's), advanced devices of this type, such as high density field programmable gate arrays (FPGA's) exhibit new single event effects (SEE), such as single particle reprogramming of anti-fuse links. New advanced bipolar circuits have been shown recently to degrade more rapidly in the low dose rate space environment than in the typical laboratory total dose radiation test used to qualify such devices. Thus total dose testing of these parts is no longer an appropriately conservative measure to be used for hardness assurance. We also note that the functionality of micromechanical Si-based devices may be altered due to the radiation-induced deposition of charge in the oxide passivation layers.

Barnes, C.↗

Development of a pulse modulator to drive 6.19 MW klystron for 15 MeV electron linac

We present the design, construction, and characterization of a line-type pulse high-voltage modulator system capable of generating 140-kV, 6 μs pulses width at 150 pulses per second into a Klystron as load. The modulator is used to energize a variety of highpower microwave devices requiring voltage stability and reproducibility. Voltage ripple is less than 0.4% during the flat top, with a shot-to-shot voltage variation of less than 0.2 %. The primary circuit consists of six-stage tuneable pulse-forming networks (PFN's). The PFN is charged by a highly stable charging power supply. The total energy stored is released through a CX-1559 E2V make thyratron into a 1: 11 pulse transformer, which generates 140 kV, 6 μs pulses. The flat-top voltage generated by the modulator is highly desirable for driving RF sources requiring high quality electron beams. Linac is one of the important fields of study in modern technology due its wide applications for medical and industrial purposes in addition to physics research. (author)

43 PARTICLE ACCELERATORS↗

Impedance Characterization of Utility-Scale Renewable Energy and Storage Systems

This paper presents the impedance characterization of utility-scale wind turbines and PV/storage inverters using a multimegawatt grid simulator-based grid integration testbed. The paper describes the testbed components including a 7 MVA grid simulator, 5 MW dynamometer, medium-voltage measurement system, and a real-time control system used for automated impedance characterization of wind turbines and inverters. Different aspects of impedance measurement are discussed, including the selection of the magnitude and type of perturbation, measurement of frequency cross-coupling between sequence impedance responses, and the alignment of the reference frame for sequence impedance measurement. The paper also demonstrates high-fidelity validation of EMT simulation models from turbine manufacturers and characterization of grid-forming inverters using impedance measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impedance Characterization of Utility-Scale Renewable Energy and Storage Systems: Preprint

This paper presents the impedance characterization of utility-scale wind turbines and PV/storage inverters using a multimegawatt grid simulator-based grid integration testbed. The paper describes testbed components including a 7 MVA grid simulator, 5 MW dynamometer, medium-voltage measurement system, and real-time control system used for automated impedance characterization of wind turbines and inverters. Different aspects of impedance measurement are discussed, including the selection of the magnitude and type of perturbation, measurement of frequency cross-coupling between sequence impedance responses, and the alignment of the reference frame for sequence impedance measurement. The paper also demonstrates high-fidelity validation of EMT simulation models and characterization of grid-forming inverters using impedance measurements.

17 WIND ENERGY↗

Environmentally-induced voltage limitations in large space power systems

Large power systems proposed for future space missions imply higher operating voltage requirements which, in turn, will interact with the space plasma environment. The effects of these interactions can only be inferred because of the limited data base of ground simulations, small test samples, and two space flight experiments. This report evaluates floating potentials for a 100 kW power system operating at 300, 500, 750, and 1000 volts in relation to this data base. Of primary concern is the possibility of discharging to space. The implications of such discharges were studied at the 500 volt operational setting. It was found that discharging can shut down the power system if the discharge current exceeds the array short circuit current. Otherwise, a power oscillation can result that ranges from 2 to 20 percent, depending upon the solar array area involved in the discharge. Means of reducing the effect are discussed.

Stevens, N. J.↗

Thermoeconomic analysis of residential rooftop photovoltaic systems with integrated energy storage and resulting impacts on electrical distribution networks

This paper investigates residential rooftop photovoltaic (PV) systems for long-term thermoeconomic benefits from PV homeowners’ perspectives and for impacts on the electrical distribution network from grid operators’ perspectives. The costs of generating electricity from grid-connected PV systems are studied with and without energy storage at the PV homeowners’ sites. Three selling scenarios for excess PV energy conversion are considered: net metering, wholesale pricing, and no payback. PV systems in Utah are utilized as case studies in this analysis. The presence of PV systems gives homeowners economic benefits such as reduced annual electricity bills. However, the levelized costs of electricity are considerably higher than the weighted electricity price in Utah. Currently, the addition of energy storage only benefits customers in Utah under the no payback policy. The impacts of PV systems toward electrical distribution networks are then studied on a distribution test system. Excess PV generation from residential PV systems causes voltage rise in the electrical distribution network. The results from this paper can educate consumers about the lifetime benefit of integrating solar energy into their homes. For grid operators, residential PV systems with energy storage can reduce the negative impacts on the grid compared with high PV penetration alone.

14 SOLAR ENERGY↗

Photovoltaic power converter system with a controller configured to actively compensate load harmonics

Photovoltaic power converter system including a controller configured to reduce load harmonics is provided. The system comprises a photovoltaic array and an inverter electrically coupled to the array to generate an output current for energizing a load connected to the inverter and to a mains grid supply voltage. The system further comprises a controller including a first circuit coupled to receive a load current to measure a harmonic current in the load current. The controller includes a second circuit to generate a fundamental reference drawn by the load. The controller further includes a third circuit for combining the measured harmonic current and the fundamental reference to generate a command output signal for generating the output current for energizing the load connected to the inverter. The photovoltaic system may be configured to compensate harmonic currents that may be drawn by the load.

de Rooij, Michael Andrew↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Long-lasting strong electrostatic attraction and adhesion forces of dust particles on photovoltaic modules

Photovoltaic (PV) energy-yield loss due to solar module soiling has become increasingly important as solar module deployment is now at the hundreds of gigawatts scale and continues to grow rapidly. The electrostatic attraction and adhesion force (F es ) of dust particles by the high voltages from solar panels have been reported to be 1 to 2 orders of magnitude stronger than the van der Waals and water capillary forces, which has been corroborated by observing the increase in system voltage-induced soiling rate by setting up an outdoor test. Here, we report another characteristic of F es on soiling - long-lasting or slow decay after turning off the high voltage applied to solar panels. The F es decay time varies across a wide time range of 1 to 10 h, depending on two factors: 1) whether the cell, the particle, or both were charged with high voltage before the voltages were turned off; and 2) how the cell was connected to the ground after the voltage was turned off - either connected through the power-supply electronics, directly connected to the ground, or electrically floated. The Fes decay is understood in terms of 1) net electrical charge dissipations in both particle and cell, 2) thermal disordering of dipole polarization in the module glass dielectrics, and 3) charge redistribution by the electrostatic interaction of particle and module glass. This long-lasting F es for hours can affect the solar panel soiling after sunset, and it can have an even greater effect when combined with water condensation at night.

14 SOLAR ENERGY↗

Testing of the J-2X Augmented Spark Igniter (ASI) and Its Electronics

Reliable operation of the spark ignition system electronics in the J‐2X Augmented Spark Igniter (ASI) is imperative in assuring ASI ignition and subsequent Main Combustion Chamber (MCC) ignition events are reliable in the J‐2X Engine. Similar to the man‐rated J‐2 and RS‐25 engines, the J‐2X ignition system electronics are equipped with spark monitor outputs intended to indicate that the spark igniters are properly energized and sparking. To better understand anomalous spark monitor data collected on the J‐2X development engines at NASA Stennis Space Center (SSC), a comprehensive subsystem study of the engine's low‐ and high‐tension spark ignition system electronics was conducted at NASA Marshall Space Flight Center (MSFC). Spark monitor output data were compared to more detailed spark diagnostics to determine if the spark monitor was an accurate indication of actual sparking events. In addition, ignition system electronics data were closely scrutinized for any indication of an electrical discharge in some location other than the firing tip of the spark igniter ‐ a problem not uncommon in the development of high voltage ignition systems.

Osborne, Robin↗

System reliability analysis through corona testing

In the Reliability and Quality Engineering Test Laboratory at the NASA Lewis Research Center a nondestructive, corona-vacuum test facility for testing power system components was developed using commercially available hardware. The test facility was developed to simulate operating temperature and vacuum while monitoring corona discharges with residual gases. This facility is being used to test various high voltage power system components.

Lalli, V. R.↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

A Medium Voltage Three-Stage Power Converter Topology for Distribution Grid Scale Energy Storage Systems

This work proposes a three-stage converter topology with a medium frequency isolation transformer for direct integration of energy storage systems into medium voltage distribution grids. The distributed architecture of the topology, using standard AC/DC converters, has been developed with the aim of plug-and-play capability and voltage and power scalability. The medium frequency transformer facilitates improved power density, while its 20:1 voltage translation capability enables the use of limited voltage level (500 Vdc) of the commercially available batteries. This paper presents the topology structure and details how it can be scaled to reach the full range of the distribution grid voltages and the required power levels. A transformer design for 500 Hz rated frequency is discussed. The control scheme of the converter equipped with voltage support, frequency support, and black start capabilities is also presented. Control hardware-in-the-loop results using OPAL-RT, with converter switching models connected to a weak IEEE-4 node test feeder modified for the aforementioned grid services, are provided to show the topology feasibility.

Chinthavali, Madhu Sudhan↗