Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sterilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

The Validation of Vapor Phase Hydrogen Peroxide Microbial Reduction for Planetary Protection and a Proposed Vacuum Process Specification

The Jet Propulsion Laboratory, in conjunction with the NASA Planetary Protection Officer, has selected the vapor phase hydrogen peroxide sterilization process for continued development as a NASA approved sterilization technique for spacecraft subsystems and systems. The goal is to include this technique, with an appropriate specification, in NPR 8020.12C as a low temperature complementary technique to the dry heat sterilization process.To meet microbial reduction requirements for all Mars in-situ life detection and sample return missions, various planetary spacecraft subsystems will have to be exposed to a qualified sterilization process. This process could be the elevated temperature dry heat sterilization process (~115 C for 40 hours) which was used to sterilize the Viking lander spacecraft. However, with utilization of such elements as highly sophisticated electronics and sensors in modern spacecraft, this process presents significant materials challenges and is thus an undesirable bioburden reduction method to design engineers. The objective of this work is to introduce vapor hydrogen peroxide (VHP) as an alternative to dry heat microbial reduction to meet planetary protection requirements.The VHP process is widely used by the medical industry to sterilize surgical instruments and biomedical devices, but high doses of VHP may degrade the performance of flight hardware, or compromise material properties. Our goal for this study was to determine the minimum VHP process conditions to achieve microbial reduction levels acceptable for planetary protection.

planetary protection↗

Dark Matter Search in Pu-241 Beta Decays

Our universe is predominantly composed of mysterious unknowns: Dark Matter (DM) and Dark Energy. DM constitutes approximately 27% of the universe, yet its nature and origins remain elusive. Among the various candidates for dark matter, this project focuses on the search for keV-scale sterile neutrinos. A sterile neutrino is a hypothetical particle that belongs to the neutrino family and may possess a higher mass than ordinary neutrinos. They are considered a compelling warm dark matter candidate if their mass is on the order of kilo-electronvolts. Existence of sterile neutrinos can be investigated via high precision beta spectroscopy. Sterile neutrinos can be produced during nuclear beta decay processes, similar to ordinary active neutrinos, but they uniquely alter the beta decay spectrum. The emission of sterile neutrinos will introduce a distinctive "kink" structure in the middle of the beta spectrum. This project investigated the existence of sterile neutrino dark matter by employing high-precision decay energy spectroscopy of Pu-241 beta decays using magnetic microcalorimeters (MMCs). The Pu-241 source material is embedded within the microcalorimeter detectors, enabling the measurement of full beta decay energies with ultra-high energy resolution. In this project, the most precise Pu-241 spectrum to date was obtained by collecting a total of 1 billion beta decay events in the MMC detectors. This extensive data set allows us to investigate evidence of keV sterile neutrino emission in beta decays with unprecedented sensitivity.

79 ASTRONOMY AND ASTROPHYSICS↗

The possible contamination of Jupiter

The Galileo probe, though at present its future is uncertain, would, if not sterilized, represent a good chance of contaminating Jupiter. Most scientists opposed to sterilizing the probe argue that to order the probe sterilized would be the death of the project, since sterilization would entail a reconstruction of the probe, and there are not enough funds to accomplish this. These scientists, however, are ignoring a relatively simple and inexpensive alternative to the traditional heat sterilization method. The main threat of contamination comes from Galileo's exterior surfaces: the shell of the probe and its parachute. The probe innermost components would not represent a threat since the probe is sealed. In light of the fact that only the exterior of Galileo would have to be sterilized, heat would not have to be used as a method of sterilization. Instead, various gas mixtures could be sprayed entirely over the probe and its parachute, gases which would kill any and all bacteria. This idea is more thoroughly examined.

Garcia, Joe↗

Microbial Methods for Testing a Novel Spacecraft Bioburden Reduction Method

In order to circumvent the contamination of microorganisms in both extraterrestrial and terrestrial environments, spacecraft hardware must often be sterilized. Current sterilization practices are both time-consuming and expensive. Techniques such as dry heat sterilization and scattered/localized electric field enhancements are incompatible with a variety of hardware materials as well as complex surface shapes. Our group is testing a novel femtosecond pulsed laser for the rapid sterilization of spacecraft hardware using high photon fluxes, which is both an efficient and effective technique to ensure a reduced microbial burden aboard spacecraft. This method is likely to be effective because microorganisms have not encountered high photon fluxes in their evolutionary history and thus contain no protective mechanisms against them. To assess the effectiveness of pulsed laser sterilization, we used a combination of scanning electron microscopy and elemental analysis for the examination of damaged spores on metal coupons, as well as microbiology methods for spore assays. The surfaces of metal coupons inoculated with Bacillus subtilis were illuminated with femtosecond pulses at various wavelengths below the damage threshold for the aluminum. After laser treatment, metal coupon samples were sonicated to dislodge spores, serially diluted, and finally plated and incubated. Results show that sterilization efficiency is favorable in some conditions. The NASA standards for spore assays are a preliminary demonstration in establishing the trend in ability to kill spores. The results show potential for the dual pulse illumination method as a sterilization technique for planetary protection applications.

Maha S Ulhaq↗

Direct comparison of gamma, electron beam and X-ray irradiation doses on characteristics of low-density polyethylene, polypropylene homopolymer, polyolefin elastomer and chlorobutyl rubber medical device polymers

There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.

sterilization, gamma, X-ray, electron beam, radiat↗

Muon-neutrino disappearance with multiple liquid argon time projection chambers in the Fermilab Booster neutrino beam

The Short Baseline Neutrino (SBN) program consists of three liquid argon time projection chamber (LArTPC) experiments: SBND, MicroBooNE and ICARUS, with 110 m, 470 m and 600 m baselines respectively. The detectors are located in the Booster Neutrino Beam (BNB) at Fermilab which has a peak energy around 0.7 GeV and contains predominantly muon neutrinos. The baseline and energy range of the SBN program is conducive to measuring neutrino oscillation parameters under various sterile neutrino hypotheses. Sterile neutrinos have been proposed as a possible solution to the numerous short baseline anomalies. The proposed particles must be sterile in nature such that they do not interact via the weak force, however they may undergo oscillations with the active neutrino flavours. Their existence may consequently be confirmed through measurements of the appearance and disappearance of the active flavours. The analyses presented in this thesis aimed to calculate and understand the sensitivity of the SBN program to measuring the ?µ disappearance parameters under the (3+1) sterile neutrino oscillation hypothesis. The sensitivity of SBN to measuring the ?µ disappearance sterile oscillation parameters, sin2 2?µµ, ?m2 41, was calculated through semi-exclusive joint fits of the ?µ CC 0p and ?µ CC Other reconstructed neutrino energy spectra. The first iteration used truth-level Monte Carlo (MC) events, and determined that the 5s SBN sensitivity is comparable to the 90% MINOS/MINOS+ confidence level and supersedes the 90% MiniBooNE confidence level across entire phase space. Semi-exclusive joint fits of the aforementioned sample spectra were performed between the MC and multiple mock data sets in SBND. This analysis assessed the accuracy with which the near detector can disentangle systematic from physics effects in the oscillation analysis. The result was a 5.49% discrepancy between the ICARUS Monte Carlo and mock data event rates, when the systematic constraints from the near detector fit were extrapolated to the far detector. The second iteration of the SBN sensitivity analysis involved the application of an event selection procedure developed in SBND, following the full reconstruction chain. ?µ CC 0p events were selected from sample of neutrinos with 84.5% efficiency and 84.3% purity. The sterile neutrino sensitivity was determined once more at the near detector with these samples, and was shown to be consistent with the truth-level studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of X-ray irradiation on human spermatogenesis

Direct cell kill and inhibition of mitosis have been suggested as mechanisms to explain the occurrence of absolute sterility following the irradiation of the testes. In order to obtain information on the existence and dose dependency of the mechanisms for man, a controlled study was initiated. Sixty-four men received a single midorgan dose to both of their testes ranging from 7.5 to 400r (f = .95). It was deduced from resulting pre-sterile period and sterile period data that both cell kill and mitosis halting mechanisms were operating. The maximum observed sterile period was 501 days with eventual recovery observed in each individual where the follow-up was complete. Thus man appears to be highly radiosensitive in regard to temporary sterility but quite radioresistant in regard to permanent sterility.

Thorslund, T. W.↗

Bag For Formulating And Dispersing Intravenous Solution

Large-volume parenteral (LVP) bag in which predetermined amount of sterile solution formulated by combining premeasured, prepackaged amount of sterile solute with predetermined amount of water. Bag designed to hold predetermined amount, typically 1 L, of sterile solution. Sterility of solution maintained during mixing by passing water into bag through sterilizing filter. System used in field or hospitals not having proper sterile facilities, and in field research.

Kipp, Jim↗

Aseptic Operations for Post DHMR Processing of MOMA Mass Spectrometer

Mars Organic Molecule Analyzer - Mass Spectrometer (MOMA-MS) is an instrument in the MOMA instrument suite for the European Space Agency (ESA) ExoMars 2020 Rover. The rover is Planetary Protection Mission Category IVb, the first IVb mission since the Viking missions in the 1970s. Within the sample path of the MOMA instrument suite, the hardware surfaces of the must be sanitized to a level of less than 0.03 spore/m sq. To meet this requirement, the MS sample path was subjected to Dry Heat Microbial Reduction (DHMR) to decrease the number of viable spores by 4 orders of magnitude from a measured 88 spores/m sq to 0.009 spores/m sq. Before DHMR, the hardware is handled using standard cleanroom practices. After DHMR, planetary protection filters protect the sample path for most of integration, but when sample path exposure is required, aseptic operations are instituted and exposure times are kept to an absolute minimum. The surface area of exposure is also taken into account to determine safe exposure times. Before work begins, the ISO class 5 aseptic workspace is cleaned and tested for surface and airborne bioburden, and all tools that will contact or be used near sample path surfaces are sterilized. During the exposure activity, sterile garments are worn, sterile gloves are changed as often as necessary, and the environment is monitored with active and passive fallout for bioburden and real time airborne particle counts. Sterile tools are handled by a two person team so that the operator touches only the tool and not the exterior surfaces of the sterilization pouch, and a sterile operating field is established as a safe place to organize tools or parts during the aseptic operations. In cases where aseptic operations are not feasible, localized DHMR is used after exposure. Any breach in the planetary protection cleanliness can necessitate repeating instrument level DHMR, which not only has significant cost and schedule implications, it also become a risk to hardware that is not rated for repeated long exposures to high temperatures.

Spacecraft Design↗

ISS External Microorganisms: A Planetary Protection Experiment to Inform Requirements for Crewed Missions to Mars

We have developed, tested, and flown a caddy capable of collecting aseptic samples from external surfaces of the ISS (International Space Station). The sampling caddy is certified for use during US EVA (extra vehicular activity) and was launched to ISS in the summer of 2023. We are scheduled to collect samples from 6 locations outside ISS during an EVA in May of 2024. We will freeze these samples at -80°C on orbit and return them to Earth. We will then extract and sequence any DNA collected during the EVA using next generation sequencing technologies to characterize the community composition and function of each sample. Measuring the type and quantity of microbes present on the exterior of ISS will allow us to address knowledge gap 2B, “Acceptable levels of microbial/organic releases from humans and support systems” described in a 2019 COSPAR report. Collecting data about microbial release from current crewed vehicles will inform requirements for acceptable leak rates for future crewed missions to Mars. The sampling kit consists of eight commercially available, sterile, DNA free, macrofoam swabs ( 23 mm. diameter ) installed in custom aluminum end effectors. Each end effector is housed in and individual aluminum canister. Each canister contains a 0.2 μm Teflon filter to allow the interior volume to accommodate pressure changes without permitting microbial contaminants to enter the sterile interior volume. A handle repurposed from the space shuttle tile repair kit is used to remove the end effector from the sample canister, collect a sample by swabbing a surface and then replace the end effector in its canister. The canisters and end effectors were cleaned and assembled on Earth. Prior to installing the sterile swab the canisters and end effectors were sterilized in an autoclave at 134°C, 215 kPA, for 7 min.. The final assembly occurred in a sterilized class II biosafety cabinet. We will collect six samples from the 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the CDRA (Carbon Dioxide Removal Assembly) vent, and 6) the VES (Vacuum Exhaust System) vent. The remaining two swabs will be reserved as controls. One swab will be exposed during the EVA without touching any surfaces to act as a blank. The final swab will remain sealed until the entire sampling kit is returned to earth. Based on previously published results from the Russian segment, we hypothesize that there will be detectable microbes at some or all of these locations. Ground-based testing of this sampling caddy confirms that the swabs remain sterile as the canisters transition in and out of vacuum. We were able to retrieve, viable bacterial and fungal cells as well as DNA from samples collected from US space suits during vacuum chamber tests lasting as long as seven hours. Based on these results and feedback from the test subjects the sampling caddy was modified to improve ergonomics and meet US EVA safety requirements. Bayonet probes were added to the sides of the sample kit as alternate mounting points. Additional locking features were added to the end effector and the filter stack to prevent inadvertent release during use. The opening mechanism was changed from one where the end effector was rocked laterally to defeat a ball detent to a twist-to-open threaded closure for similar reasons. Demonstrating, this sampling caddy’s effectiveness during a US EVA will allow us to address knowledge gaps identified in COSPAR reports and begin to define planetary protection requirements for life support systems on crewed missions to mars. This kit could also be used to collect contamination control samples during Artemis missions to verify requirements and could be easily modified for robotic sample collection.

Planetary Protection↗

ISS External Microorganisms: Collecting Planetary Protection Samples During Extravehicular Activity

We have developed, tested, and flown a caddy capable of collecting aseptic samples from external surfaces of the ISS (International Space Station). The sampling caddy is certified for use during US EVA (extra vehicular activity) and was launched to ISS in the summer of 2023. We are scheduled to collect samples from 6 locations outside ISS during an EVA in May of 2024. We will freeze these samples at -80°C on orbit and return them to Earth. We will then extract and sequence any DNA collected during the EVA using next generation sequencing technologies to characterize the community composition and function of each sample. Measuring the type and quantity of microbes present on the exterior of ISS will allow us to address knowledge gap 2B, “Acceptable levels of microbial/organic releases from humans and support systems” described in a 2019 COSPAR report. Collecting data about microbial release from current crewed vehicles will inform requirements for acceptable leak rates for future crewed missions to Mars. The sampling kit consists of eight commercially available, sterile, DNA free, macrofoam swabs ( 23 mm. diameter ) installed in custom aluminum end effectors. Each end effector is housed in and individual aluminum canister. Each canister contains a 0.2 μm Teflon filter to allow the interior volume to accommodate pressure changes without permitting microbial contaminants to enter the sterile interior volume. A handle repurposed from the space shuttle tile repair kit is used to remove the end effector from the sample canister, collect a sample by swabbing a surface and then replace the end effector in its canister. The canisters and end effectors were cleaned and assembled on Earth. Prior to installing the sterile swab the canisters and end effectors were sterilized in an autoclave at 134°C, 215 kPA, for 7 min.. The final assembly occurred in a sterilized class II biosafety cabinet. We will collect six samples from the 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the CDRA (Carbon Dioxide Removal Assembly) vent, and 6) the VES (Vacuum Exhaust System) vent. The remaining two swabs will be reserved as controls. One swab will be exposed during the EVA without touching any surfaces to act as a blank. The final swab will remain sealed until the entire sampling kit is returned to earth. Based on previously published results from the Russian segment, we hypothesize that there will be detectable microbes at some or all of these locations. Ground-based testing of this sampling caddy confirms that the swabs remain sterile as the canisters transition in and out of vacuum. We were able to retrieve, viable bacterial and fungal cells as well as DNA from samples collected from US space suits during vacuum chamber tests lasting as long as seven hours. Based on these results and feedback from the test subjects the sampling caddy was modified to improve ergonomics and meet US EVA safety requirements. Bayonet probes were added to the sides of the sample kit as alternate mounting points. Additional locking features were added to the end effector and the filter stack to prevent inadvertent release during use. The opening mechanism was changed from one where the end effector was rocked laterally to defeat a ball detent to a twist-to-open threaded closure for similar reasons. Demonstrating, this sampling caddy’s effectiveness during a US EVA will allow us to address knowledge gaps identified in COSPAR reports and begin to define planetary protection requirements for life support systems on crewed missions to mars. This kit could also be used to collect contamination control samples during Artemis missions to verify requirements and could be easily modified for robotic sample collection.

Planetary Protection↗

Effects of X-Rays, Electron Beam, and Gamma Irradiation on Chemical and Physical Properties of EVA Multilayer Films

Gamma-ray irradiation, using the cobalt-60 isotope, is the most common radiation modality used for medical device and biopharmaceutical products sterilization. Although X-ray and electron-beam (e-beam) sterilization technologies are mature and have been in use for decades, impediments remain to switching to these sterilization modalities because of lack of data on the resulting radiation effects for the associated polymers, as well as a lack of education for manufacturers and regulators on the viability of these sterilization alternatives. For this study, the compatibility of ethylene vinyl acetate (EVA) multilayer films with different ionizing radiation sterilization (X-ray, e-beam, and gamma irradiation) is determined by measuring chemical and physical film properties using high performance liquid chromatography, differential scanning calorimetry, Fourier-Transform InfraRed spectroscopy (FTIR), surface energy measurement, and electron spin resonance techniques. The results indicate that the three irradiation modalities induce no differences in thermal properties in the investigated dose range. Gamma and X-Ray irradiations generate the same level of reactive species in the EVA multilayer film, whereas e-beam generates a reduced quantity of reactive species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ecology and thermal inactivation of microbes in and on interplanetary space vehicle components

An experimental sterilization facility was developed to simulate conditions that will be encountered during terminal sterilization of space vehicles. The system consists of a temperature controlled oven with a nitrogen gas stream containing a known concentration of water. Moisture analyzers are utilized to monitor the gas flowing over spore samples contained in the oven. In its original configuration, no provision was made for the control of water vapor during the sterilization cycle. Because moisture profoundly influences the thermal inactivation of bacterial spores, an upper limit for the moisture content in the gas used to sterilize the space vehicle was established (25% RH at 0 C STP). Accordingly, a controller was developed and installed to provide these conditions in the experimental sterilization facility.

Wimsatt, J. C.↗

Revision to Planetary Protection Policy for Mars Missions

Under existing COSPAR policy adopted in 1984, missions to Mars (landers, probes, and some orbiters) are designated as Category IV missions. As such, the procedures for implementing planetary protection requirements could include trajectory biasing, cleanrooms, bioload reduction, sterilization of hardware, and bioshields, i. e. requirements could be similar to Viking. However, in 1992, a U. S. National Academy of Sciences study recommended that controls on forward contamination of Mars be tied to specific mission objectives. The report recommended that Mars landers with life detection instruments be subject to at least Viking-level sterilization procedures for bioload reduction, while spacecraft (including orbiters) without life detection instruments be subject to at least Viking-level pre sterilization procedures for bioload reduction but need not be sterilized. In light of this, it is proposed that the current policy's Category IV missions and their planetary protection requirements be divided into two subcategories as follows: Category IV A, for missions comprising landers and probes without life detection experiments and some orbiters, which will meet a specified bioburden limit for exposed surfaces; Category IV B, for landers and probes with life detection experiments, which will require complete system sterilization. For Category IV A missions, bioburden specifications will be proposed and implementing procedures discussed. A resolution will be proposed to modify the existing COSPAR policy to reflect these changes. Similar specifications, procedures, and resolution for Category IV B missions will be the subject of a later study.

DeVincenzi, D. L.↗

Refinement of planetary protection policy for Mars missions

Under existing COSPAR policy adopted in 1984, missions to Mars (landers, probes, and some orbiters) are designated as Category IV missions. As such, the procedures for implementing planetary protection requirements could include trajectory biasing, cleanrooms, bioload reduction, sterilization of hardware, and bioshields. In 1992, a U.S. National Research Council study recommended that controls on forward contamination of Mars be tied to specific mission objectives. The report recommended that Mars landers with life detection instruments be subject to at least Viking-level sterilization procedures for bioload reduction, while spacecraft (including orbiters) without life detection instruments be subject to at least Viking-level pre-sterilization procedures for bioload reduction but need not be sterilized. In light of this, it is proposed that the current policy's Category IV and its planetary protection requirements be divided into two sub-categories as follows: Category IVa, for missions comprising landers and probes without life detection experiments, which will meet a specified bioburden limit for exposed surfaces, and Category IVb, for landers and probes with life detection experiments, which will require sterilization of landed systems. In addition, Category III orbiter mission specifications are expanded to be consistent with these recommendations.

NASA Discipline Exobiology↗

Planetary Protection Concerns During Pre-Launch Radioisotope Power System Final Integration Activities

The Advanced Stirling Radioisotope Generator (ASRG) is a next-generation radioisotope-based power system that is currently being developed as an alternative to the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG). Power sources such as these may be needed for proposed missions to solar system planets and bodies that have challenging Planetary Protection (PP) requirements (e.g. Mars, Europa, Enceladus) that may support NASA s search for life, remnants of past life, and the precursors of life. One concern is that the heat from the ASRG could potentially create a region in which liquid water may occur. As advised by the NASA Planetary Protection Officer, when deploying an ASRG to Mars, the current COSPAR/NASA PP policy should be followed for Category IVc mission. Thus, sterilization processing of the ASRG to achieve bioburden reduction would be essential to meet the Planetary Protection requirements. Due to thermal constraints and associated low temperature limits of elements of the ASRG, vapor hydrogen peroxide (VHP) was suggested as a candidate alternative sterilization process to complement dry heat microbial reduction (DHMR) for the assembled ASRG. The following proposed sterilization plan for the ASRG anticipates a mission Category IVc level of cleanliness. This plan provides a scenario in which VHP is used as the final sterilization process. Keywords: Advanced Stirling Radioisotope Generator (ASRG), Planetary Protection (PP), Vapor hydrogen peroxide (VHP) sterilization.

Chen, Fei↗

Testing Explanations of Short Baseline Neutrino Anomalies

The experimental observation of neutrino oscillations profoundly impacted the physics of neutrinos, from being well understood theoretically to requiring new physics beyond the standard model of particle physics. Indeed, the mystery of neutrino masses implies the presence of new particles never observed before, often called sterile neutrinos, as they would not undergo standard weak interactions. And while neutrino oscillation measurements entered the precision era, reaching percent-level precision, many experimental results show significant discrepancies with the standard model, at baselines much shorter than typical oscillation baselines, like LSND, MiniBooNE, gallium experiments, and reactor antineutrino measurements. These short baseline anomalies could be explained by the addition of a light sterile neutrino, with mass in the $1-10~\text{eV}$ range, however, in strong tension with many null experimental observations. Other explanations that rely on sterile neutrinos with masses in the $1-500~\text{MeV}$ could resolve the tension. Here we test both classes of models. On the one hand, we look for datasets collected at a short baseline which can constrain heavy sterile neutrino models. We find that the minimal model is fully constrained, but several extensions of this model could weaken the current constraint and be tested with current and future datasets. On the other hand, we test the presence of neutrino oscillations at short baselines, induced by a light sterile state, with the data collected by the MicroBooNE experiment, a liquid argon time projection chamber specifically designed to resolve the details of each neutrino interaction. We report null results from both analyses, further constraining the space of possible explanations for the short baseline anomalies. If new physics lies behind the short baseline anomaly puzzle, it is definitely not described by a simple model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗