Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectroscopic methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

HIGH-RESOLUTION LABORATORY SPECTRA OF THE λ193 CHANNEL OF THE ATMOSPHERIC IMAGING ASSEMBLY INSTRUMENT ON BOARD SOLAR DYNAMICS OBSERVATORY

Extreme ultraviolet spectra of C, O, F, Ne, S, Ar, Fe, and Ni have been excited in an electron beam ion trap and studied with much higher resolution than available on the Solar Dynamics Observatory (SDO) in order to ascertain the spectral composition of the SDO/Atmospheric Imaging Assembly (AIA) observations. We present our findings in the wavelength range 182-200 Å, which, overall, corroborate the working models of how to interpret the SDO/AIA data. We find, however, that the inclusion of a number of additional lines might improve the data interpretation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Assessment of individual organ doses in a realistic human phantom from neutron and gamma stimulated spectroscopy of the breast and liver

Purpose: Understanding the radiation dose to a patient is essential when considering the use of an ionizing diagnostic imaging test for clinical diagnosis and screening. Using Monte Carlo simulations, the authors estimated the three-dimensional organ-dose distribution from neutron and gamma irradiation of the male liver, female liver, and female breasts for neutron- and gamma-stimulated spectroscopic imaging. Methods: Monte Carlo simulations were developed using the Geant4 GATE application and a voxelized XCAT human phantom. A male and a female whole body XCAT phantom was voxelized into 256 × 256 × 600 voxels (3.125 × 3.125 × 3.125 mm{sup 3}). A monoenergetic rectangular beam of 5.0 MeV neutrons or 7.0 MeV photons was made incident on a 2 cm thick slice of the phantom. The beam was rotated at eight different angles around the phantom ranging from 0° to 180°. Absorbed dose was calculated for each individual organ in the body and dose volume histograms were computed to analyze the absolute and relative doses in each organ. Results: The neutron irradiations of the liver showed the highest organ dose absorption in the liver, with appreciably lower doses in other proximal organs. The dose distribution within the irradiated slice exhibited substantial attenuation with increasing depth along the beam path, attenuating to ∼15% of the maximum value at the beam exit side. The gamma irradiation of the liver imparted the highest organ dose to the stomach wall. The dose distribution from the gammas showed a region of dose buildup at the beam entrance, followed by a relatively uniform dose distribution to all of the deep tissue structures, attenuating to ∼75% of the maximum value at the beam exit side. For the breast scans, both the neutron and gamma irradiation registered maximum organ doses in the breasts, with all other organs receiving less than 1% of the breast dose. Effective doses ranged from 0.22 to 0.37 mSv for the neutron scans and 41 to 66 mSv for the gamma scans. Conclusions: Neutron and gamma irradiation of a primary target organ was found to impart the majority of the total dose to the primary target organ (and other large organs) within the beam plane and considerably lower dose to proximal organs outside of the beam. These results also indicate that despite the use of a highly scattering particle such as a neutron, the dose from neutron stimulated emission computed tomography scans is on par with other clinical imaging techniques such as x-ray computed tomography (x-ray CT). Given the high nonuniformity in the dose across an organ during the neutron scan, care must be taken when computing average doses from neutron irradiations. The effective doses from neutron scanning were found to be comparable to x-ray CT. Further technique modifications are needed to reduce the effective dose levels from the gamma scans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation into the Influence of a Buffer Layer of Nanoporous Silicon on the Atomic and Electronic Structure and Optical Properties of A{sup III}N/por-Si Heterostructures Grown by Plasma-Activated Molecular-Beam Epitaxy

The influence of using a buffer sublayer of nanoporous por-Si on the morphological, physical, and structural properties of nanocolumnar In{sub x}Ga{sub 1 –x}N structures fabricated by plasma-activated molecular-beam epitaxy on single-crystal Si(111) substrates is shown. Using a set of structural-spectroscopic analytical methods, the electronic structure of the grown heterostructures, morphology, and optical properties are investigated, and the interrelations between them are established. It is shown that the use of a por-Si sublayer makes it possible to attain a more uniform distribution of diameters of In{sub x}Ga{sub 1 –x}N nanocolumns and to increase the photoluminescence intensity of the latter.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multidimensional Coherent Spectroscopy of van der Waals materials and heterostructures (Final Technical Report)

This project advanced multidimensional coherent spectroscopy (MDCS) and related spectroscopic-imaging methods as quantitative probes of many-body optical excitations in two-dimensional (2D) van der Waals (vdW) semiconductors and their heterostructures. Monolayer transition-metal dichalcogenides (TMDs) such as MoSe 2 and WSe 2 provide a uniquely strong platform for excitonic physics due to reduced dielectric screening, which enhances Coulomb interactions and makes higher-order correlated states (e.g., biexcitons and exciton–trion correlations) more prominent than in conventional bulk semiconductors. At the same time, the same sensitivity that enables strong interactions also increases susceptibility to spatial inhomogeneity—e.g., strain gradients, wrinkles, nanoscale disorder potentials, and charge puddling—which can broaden resonances, obscure interaction signatures, and complicate device-to-device reproducibility. The work reported here addressed this dual opportunity and challenge by: (i) developing and deploying coherent multidimensional methods (including double-quantum MDCS) capable of isolating interaction signals with reduced background, (ii) integrating electrostatic control to tune carrier populations and interaction strengths in situ, and (iii) introducing complementary spatially resolved photoluminescence (PL) techniques—hyperspectral PL imaging and polarization-/field-dependent PL lineshape analysis—to directly quantify disorder, strain, and localization that govern the coherent response.

36 MATERIALS SCIENCE↗

Engineering Atomic-to-Nano Scale Structural Homogeneity towards High Corrosion Resistance of Amorphous Magnesium-Based Alloys

Magnesium-based amorphous alloys have aroused broad interest in being applied in marine use due to their merits of lightweight and high strength. Yet, the poor corrosion resistance to chloride-containing seawater has hindered their practical applications. Herein, we propose a new strategy to improve the chloride corrosion resistance of amorphous Mg 65 Cu 15 Ag 10 Gd 10 alloys by engineering atomic-to-nano scale structural homogeneity, which is implemented by heating the material to the critical temperature of the liquid–liquid transition. By using various electrochemical, microscopic, and spectroscopic characterization methods, we reveal that the liquid–liquid transition can rearrange the local structural units in the amorphous structure, slightly decreasing the alloy structure’s homogeneity, accelerate the formation of protective passivation film, and, therefore, increase the corrosion resistance. Our study has demonstrated the strong coupling between an amorphous structure and corrosion behavior, which is available for optimizing corrosion-resistant alloys.

36 MATERIALS SCIENCE↗

Large-scale Environmental Dependence of the Abundance Ratio of Nitrogen to Oxygen in Blue, Star-forming Galaxies Fainter than L{sub *}

We examine how the cosmic environment affects the chemical evolution of galaxies in the universe by comparing the N/O ratio of dwarf galaxies in voids with that of dwarf galaxies in denser regions. Ratios of the forbidden [O iii] and [S ii] transitions provide estimates of a region’s electron temperature and number density. We estimate the abundances of oxygen and nitrogen using these temperature and density estimates and the emission-line fluxes [O ii] λ3727, [O iii] λλ4959,5007, and [N ii] λλ6548,6584 with the direct T {sub e} method. Using spectroscopic observations from the Sloan Digital Sky Survey Data Release 7, we are able to estimate the N/O ratio in 42 void dwarf galaxies and 89 dwarf galaxies in denser regions. The N/O ratio for void dwarfs (M{sub r}>−17) is slightly lower (∼12%) than for dwarf galaxies in denser regions. We also estimate the nitrogen and oxygen abundances of 2050 void galaxies and 3883 galaxies in denser regions with M{sub r}>−20. These somewhat brighter galaxies (but still fainter than L {sub *}) also display similar minor shifts in the N/O ratio. The shifts in the average and median element abundance values in all absolute magnitude bins studied are in the same direction, suggesting that the large-scale environment may influence the chemical evolution of galaxies. We discuss possible causes of such a large-scale environmental dependence of the chemical evolution of galaxies, including retarded star formation and a higher ratio of dark matter halo mass to stellar mass in void galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

A two-photon laser-induced fluorescence field instrument for ground-based and airborne measurements of atmospheric NO

This paper reports on a new two-photon laser-induced fluorescence (TP-LIF) sensor capable of making routine measurements at the few parts per trillion volume level. This direct spectroscopic detection method has been demonstrated to be a reliable instrument while performing both on the ground and in the air. As currently designed it is unique in being 'signal' rather than 'signal-to-noise' limited. The latter characteristic enables the TP-LIF sensor to make atmospheric measurements of NO under environmental conditions that might normally be considered unsuitable for a laser technique. These include clouds, rain, and, in general, high-atmospheric-aerosol loading conditions. Of special interest is the insensitivity of the TP-LIF NO instrument to changes in pressure while operating in the troposphere. This characteristic has enabled this sensor to be used to record real-time altitude profiles of NO. Future improvements should make possible two measurement opportunities: (1) NO flux measurements via the airborne eddy-correlation method and (2) nitrogen isotopic distribution measurements (e.g., (N-15)(0-16) versus (N-14)(0-16) as a means of identifying specific NO(x) sources.

Bradshaw, J. D.↗

An observational investigation of the comet-asteroid connection

Recent observations indicate that comet nuclei and certain asteroids, particularly near-Earth asteroids (NEA) and the distant asteroids, may have much in common. The authors investigated the possible connection between comets and asteroids via two methods. A spectroscopic survey of two groups of asteroids that may be related to comets, namely the NESs and Trojan asteroids, indicates that we cannot dispel the hypothesis of a main-belt origin NEAs, while the Trojan survey shows that the Trojans and the known comet nuclei are spectrally similar over the wavelengths examined. Results of attempts to determine the mass loss rates of NEAs indicate that we cannot exclude the possibility that low-activity comets exist in the NEA population and have escaped detection simply because their small sizes result in mass loss rates which are below the detection limit.

Luu, Jane X.↗

Portable flash lamp reflectance analyzer system and method

The system and method allow spectroscopic analysis of vegetation or the like without effects from changing sun and cloud conditions, undesired portions of the area of interest or atmospheric disturbances. The system (1) includes a light source (5) such as a xenon flash lamp, a telescope (7), a spectrometer (9), an analog/digital converter (11), a memory (13), a display (15), and an on-board microprocessor (17) or a port (19) for attachment to a laptop computer. The system is taken to an area of interest in the woods (step 41), the vegetation is illuminated from below (step 43) and data are taken (step 45).

Kalshoven, James Edward↗

Biosensors for EVA: Muscle Oxygen and pH During Walking, Running and Simulated Reduced Gravity

During lunar excursions in the EVA suit, real-time measurement of metabolic rate is required to manage consumables and guide activities to ensure safe return to the base. Metabolic rate, or oxygen consumption (VO2), is normally measured from pulmonary parameters but cannot be determined with standard techniques in the oxygen-rich environment of a spacesuit. Our group developed novel near infrared spectroscopic (NIRS) methods to calculate muscle oxygen saturation (SmO2), hematocrit, and pH, and we recently demonstrated that we can use our NIRS sensor to measure VO2 on the leg during cycling. Our NSBRI-funded project is looking to extend this methodology to examine activities which more appropriately represent EVA activities, such as walking and running and to better understand factors that determine the metabolic cost of exercise in both normal and lunar gravity. Our 4 year project specifically addresses risk: ExMC 4.18: Lack of adequate biomedical monitoring capability for Constellation EVA Suits and EPSP risk: Risk of compromised EVA performance and crew health due to inadequate EVA suit systems.

Lee, S. M. C.↗

Eta Carinae: Linelist for the Emission Spectrum of the Weigelt Blobs in the 1700-10400Angstrom Wavelength Region

Aims. We present line identifications in the 1700 to 10400A region for the Weigelt Blobs B and D, located 0.1 to 0.3" NNW of Eta Carinae. The aim of this work is to characterize the behavior of these luminous, dense gas condensations in response to the broad maximum and short minimum states of Eta Carinae during its 5.54-year spectroscopic period. Methods. The observations were carried out during March 1998, the minimum spectrum, and in February 1999, early maximum spectrum, with the Hubble Space Telescope/Space Telescope Imaging Spectrograph (HST/STIS) from 1640 to 10400A using the 52"x0.1" aperture centered on Eta Carinae at position angle -28 degrees. Extractions of the reduced spectrum centered on Weigelt B and D, 0.28: in length along the slit, were used to identify the narrow, nebular emission lines, measure their wavelengths and estimate their fluxes. Results. A linelist of 1500 lines is presented for the maximum and minimum states of combined Weigelt blobs B and D. The spectra are dominated by emission lines from the iron-group elements, but include lines from lighter elements. They include parity permitted and forbidden lines. A number of lines are fluorescent lines pumped by H Ly alpha. Other lines show anomalous excitation.

Zethson, T.↗

Effects of Polar Stratospheric Clouds in the Nimbus 7 LIMS Version 6 Data Set

The historic Limb Infrared Monitor of the Stratosphere (LIMS) measurements of 1978-1979 from the Nimbus 7 satellite were re-processed with Version 6 (V6) algorithms and archived in 2002. The V6 data set employs updated radiance registration methods, improved spectroscopic line parameters, and a common vertical resolution for all retrieved parameters. Retrieved profiles are spaced about every 1.6 of latitude along orbits and include the additional parameter of geopotential height. Profiles of O3 are sensitive to perturbations from emissions of polar stratospheric clouds (PSCs). This work presents results of implementing a first-order screening for effects of PSCs using simple algorithms based on vertical gradients of the O3 mixing ratio. Their occurrences are compared with the co-located, retrieved temperatures and related to the temperature thresholds needed for saturation of H2O and/or HNO3 vapor onto PSC particles. Observed daily locations where the major PSC screening criteria are satisfied are validated against PSCs observed with the Stratospheric Aerosol Monitor (SAM) II experiment also on Nimbus 7. Remnants of emissions from PSCs are characterized for O3 and HNO3 following the screening. PSCs may also impart a warm bias in the co-located LIMS temperatures, but by no more than 1-2K at the altitudes of where effects of PSCs are a maximum in the ozone; thus, no PSC screening was applied to the V6 temperatures. Minimum temperatures vary between 187 and 194K and often occur 1 to 2 km above where PSC effects are first identified in the ozone (most often between about 21 and 28 hPa). Those temperature-pressure values are consistent with conditions for the existence of nitric acid trihydrate (NAT) mixtures and to a lesser extent of super-cooled ternary solution (STS) droplets. A local, temporary uptake of HNO3 vapor of order 1-3 ppbv is indicated during mid-January for the 550K surface. Seven-month time series of the distributions of LIMS O3 and HNO3 are shown based on their gridded Level 3 data following the PSC screening. Zonal coefficients of both species are essentially free of effects from PSCs on the 550K surface, based on their average values along PV contours and in terms of equivalent latitude. Remnants of PSCs are still present in O3 on the 450K surface during mid- January. It is judged that the LIMS Level 3 data are of good quality for analyzing the larger-scale, stratospheric chemistry and transport processes during the Arctic winter of 1978- 1979.

Remsberg, Ellis↗

Optical Spectroscopy of Venus Aerosol Analogs and Substrate Survivability

Aerosol Rapid Analysis Combined Entry Probe/Sonde Technology (AERACEPT) is a dual descent probe and in-situ sampler of cloud and aerosol particles, used as part of the Nephele mission concept to study Venus cloud layers. Various optical spectroscopic characterization methods, including Raman spectroscopy and Surface Enhanced Raman Spectroscopy (SERS), Laser induced Breakdown Spectroscopy (LIBS), and absorbance and fluorescence spectroscopy are being assessed for viability for compatibility with AERACEPT. Specifically, the detection limits, sensitivity, specificity, and analysis cadence of these techniques for a set of Venus aerosol analogs and their mixtures are tested. We report on preliminary optical spectroscopy results of the Venus aerosol analogs, as well as optical substrate survivability in heated and acidic conditions, substrate physical robustness, and analyte wettability on substrates.

Venus↗

The importance of parameter variances, correlations lengths, and cross-correlations in reactive transport models: key considerations for assessing the need for microscale information

A process-oriented modeling approach is implemented to examine the importance of parameter variances, correlation lengths, and especially cross-correlations in contaminant transport predictions over large scales. It is shown that the most important consideration is the correlation between flow rates and retardation processes (e.g., sorption, matrix diffusion) in the system. lf flow rates are negatively correlated with retardation factors in systems containing multiple flow pathways, then characterizing these negative correlation(s) may have more impact on reactive transport modeling than microscale information. Such negative correlations are expected in porous-media systems where permeability is negatively correlated with clay content and rock alteration (which are usually associated with increased sorption). Likewise, negative correlations are expected in fractured rocks where permeability is positively correlated with fracture apertures, which in turn are negatively correlated with sorption and matrix diffusion. Parameter variances and correlation lengths are also shown to have important effects on reactive transport predictions, but they are less important than parameter cross-correlations. Microscale information pertaining to contaminant transport has become more readily available as characterization methods and spectroscopic instrumentation have achieved lower detection limits, greater resolution, and better precision. Obtaining detailed mechanistic insights into contaminant-rock-water interactions is becoming a routine practice in characterizing reactive transport processes in groundwater systems (almost necessary for high-profile publications). Unfortunately, a quantitative link between microscale information and flow and transport parameter distributions or cross-correlations has not yet been established. One reason for this is that quantitative microscale information is difficult to obtain in complex, heterogeneous systems. So simple systems that lack the complexity and heterogeneity of real aquifer materials are often studied. Another is that instrumentation used to obtain microscale information often probes only one variable or family of variables at a time, so linkages to other variables must be inferred by indirect means from other lines of evidence. Despite these limitations, microscale information can be useful in the development and validation of reactive transport models. For example, knowledge of mineral phases that have strong affinities for contaminants can help in the development of cross-correlations between flow and sorption parameters via characterization of permeability and mineral distributions in aquifers. Likewise, microscale information on pore structures in low-permeability zones and contaminant penetration distances into these zones from higher-permeability zones (e.g., fractures) can provide valuable constraints on the representation of diffusive mass transfer processes between flowing porosity and secondary porosity. The prioritization of obtaining microscale information in any groundwater system can be informed by modeling exercises such as those conducted for this study.

54 ENVIRONMENTAL SCIENCES↗

Angular-divergence calculation for Experimental Advanced Superconducting Tokamak neutral beam injection ion source based on spectroscopic measurements

Calorimetric method has been primarily applied for several experimental campaigns to determine the angular divergence of high-current ion source for the neutral beam injection system on the Experimental Advanced Superconducting Tokamak (EAST). A Doppler shift spectroscopy has been developed to provide the secondary measurement of the angular divergence to improve the divergence measurement accuracy and for real-time and non-perturbing measurement. The modified calculation model based on the W7AS neutral beam injectors is adopted to accommodate the slot-type accelerating grids used in the EAST's ion source. Preliminary spectroscopic experimental results are presented comparable to the calorimetrically determined value of theoretical calculation.

43 PARTICLE ACCELERATORS↗

An iterative method to deblend AGN-Host contributions for Integral Field spectroscopic observations

ABSTRACT We present a new iterative deblending method to separate the host galaxy (HG) and their Active Galactic Nuclei (AGNs) emission with the use of Integral Field spectroscopic (IFS) data. The method decomposes the resolved HG emission from the unresolved AGN emission by modelling the two-dimensional surface brightness (SB) profile of the point-spread function (PSF) and the two-dimensional SB HG continuum simultaneously per each monochromatic slide. Our method does not require any prior information about the observed SB profile or a detailed fitting of the PSF, making it ideal for the automatic analysis of large galaxy samples. In this work, we test the quality of our method, its advantages, and its disadvantages. We test our method by using a set of IFS mock data cubes to quantify the reliability of our deblending process and further compare our method with the qdblend3d analysis tool. Furthermore, we applied our method to three data cubes selected from the MaNGA survey according to the dominance of either its HG or its AGN. We show that our deblending method is capable of disengaging the bright, non-resolved AGN emission from the HG continuum and its narrow emission lines. However, the decoupling depends on how well the IFS spatially resolves the PSF, and on the relative flux intensity of the HG-AGN. Therefore, the method is ideal for disentangling the bright-flux contribution from AGN-dominated spectra.

Ibarra-Medel, H. (ORCID:0000000297906313)↗

Challenges in the study of chemistry and photochemistry at air–water interfaces: Toward in situ monitoring of reaction kinetics with spectroscopic techniques

Air–water interfaces, including those on droplet surfaces, have been the subject of many recent experiments due to their propensity for unique chemistry. Here, in this study, an overview of some recent advancements in understanding interfacial reaction kinetics is provided, highlighting non-surface-specific methods—such as mass spectrometry—compared with the advantages of surface-specific techniques—such as reflection–absorption spectroscopy, sum frequency generation, and photoelectron spectroscopy. This Perspective discusses the information depth and time constraints of common surface-specific spectroscopic methods that need to be addressed to monitor interfacial chemistry in situ and uses a few key examples from the literature as case studies. It concludes by advocating for the continued development of advanced spectroscopic methods to further investigate interfacial chemistry, underscoring the need for interdisciplinary collaboration to bridge the gap between molecular-level insights and macroscopic observations in future research.

Air-water interface↗