Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

BIRCHES and Lunarcubes: Building the First Deep Space Cubesat Broadband IR Spectrometer

The Broadband InfraRed Compact High-resolution Exploration Spectrometer (BIRCHES), which will be described in detail here, is the compact broadband IR spectrometer of the Lunar Ice Cube mission. Lunar Ice Cube is one of 13 6U cubesats that will be deployed by EM1 in cislunar space, qualifying as lunarcubes. The LunarCube paradigm is a proposed approach for extending the affordable CubeSat standard to support access to deep space via cis-lunar/lunar missions. Because the lunar environment contains analogs of most solar system environments, the Moon is an ideal target for both testing critical deep space capabilities and understanding solar system formation and processes. Effectively, as developments are occurring in parallel, 13 prototype deep space cubesats are being flown for EM1. One useful outcome of this ‘experiment’ will be to determine to what extent it is possible to develop a lunarcube ‘bus’ with standardized interfaces to all subsystems using reasonable protocols for a variety of payloads. The lunar ice cube mission was developed as the test case in a GSFC R&D study to determine whether the cubesat paradigm could be applied to deep space, science requirements driven missions, and BIRCHES was its payload. Here, we present the design and describe the ongoing development, and testing, in the context of the challenges of using the cubesat paradigm to fly a broadband IR spectrometer in a 6U platform, including minimal funding and extensive need for leveraging existing assets and relationships on development, the foreshortened schedule for payload delivery on testing, and minimum bandwidth translating into simplified or canned operation.

Chapin, Peter↗

Spectral Properties of Dust on Asteroid (101955) Bennu with the OSIRIS-REx Visible and Infrared Spectrometer (OVIRS)

The Origins, Spectral Interpretation, Resource Identification, Security-Regolith Explorer (OSIRIS-REx) spacecraft successfully collected a sample of regolith from asteroid (101955) Bennu on October 20, 2020[1]. The Touch-and-Go (TAG) spacecraft maneuver used to collect the sample mobilized material, including very fine particles (dust),from up to ~1m in depth and ~10m in diameter from the point of contact with the asteroid [1,2].TAG created a dust plume that intercepted the spacecraft and accumulated on the instruments. As a result, all instruments show degradation in optical throughput, with the degree of degradation depending on their aperture size, orientation, and position on the spacecraft [1]. In this study, we analyzed OSIRIS-REx Visible and Infrared Spectrometer (OVIRS) from before and after TAG to assess the dust on the instrument with implications for Bennu’s dust composition and scattering properties, and future visible–near-infrared (VNIR)spectral observations with the OSIRIS-REx spacecraft. OVIRS is a point spectrometer that measures reflected light at VNIR wavelengths from 0.4 to 4.3 μm with a 4 mrad circular field of view(FOV) [3]. Previous observations with OVIRS revealed widespread hydrated minerals and carbon-bearing materials on Bennu [4,5]. A ~3 μm absorption feature is observed globally in OVIRS spectra, with a band position and depth that is consistent with Mg/Fe phyllosilicates and suggests a similar degree of aqueous alteration to that experienced by some carbonaceous chondrite meteorites[4,6]. A series of weak (<5%) VNIR spectral features, potentially associated with hydrated phyllosilicates and iron oxides, are also found in OVIRS spectra (Fig. 1), though not typically observed in meteorite spectra [7]. OSIRIS-REx Thermal Emission Spectrometer (OTES) spectra are consistent with a very thin accumulation (a few to ~ten microns) of fine particles (<~65–100 microns in size)across the surface of Bennu, and particularly on the roughest boulders, an interpretation that is supported by the dust plume seen during TAG [1,8]. An analysis of TAG contamination on the OTES optics revealed a 15% decrease in throughput, and OTES observations of space with and without that contamination allow a recreation of the thermal infrared spectrum [1]. The spectrum of the contamination lacks volume scattering features and exhibits a stronger Mg-OH absorption (~16.5 μm) than average Bennu, suggesting a Mg-rich phyllosilicate composition [1,6]. Here we present the first compositional analysis of Bennu dust at VNIR wavelengths by analyzing the contaminant on OVIRS.

H H Kaplan↗

Recent Developments in Tolerancing Methods for Imaging Spectrometers

We discuss detailed tolerancing methods developed for imaging spectrometers at NASA Jet Propulsion Laboratory, California Institute of Technology using the Earth Surface Mineral Dust Source Investigation (EMIT) imaging spectrometer as an illustrative example. We tolerance five metrics simultaneously: along-track response function, cross-track response function, spectral response function, spectral centroid uniformity, and spatial centroid uniformity. A method to calculate tolerancing sensitivities for each metric directly, a method to statistically combine Monte Carlo files from multiple tolerancing runs, and an example summary error budgets that communicate the key and driving tolerances for each metric are discussed. These methods facilitate rapid and semi-automated assessment of the predicted performance of imaging spectrometer systems from design through to assembly and launch life cycle, using metrics that are directly relevant to the extraction of accurate spectroscopic data from these instruments.

Mouroulis, Pantazis↗

DSN Radio Astronomy Spectrometer

The Deep Space Network (DSN) enables NASA to communicate with its deep space spacecraft. By virtue of its large antennas, the DSN can be used as a powerful instrument for radio astronomy. In particular, Deep Space Station (DSS) 43, the 70 m antenna at the Canberra Deep Space Communications Complex (CDSCC) has a K-band radio astronomy system covering a 10 GHz bandwidth at 17 to 27 GHz. This spectral range covers a number of atomic and molecular lines, produced in a rich variety of interstellar gas conditions. A new high-resolution spectrometer was deployed at CDSCC in November 2019 and connected to the K-band downconverter. The system has two different firmware modes: 1) Using a 65k-pt FFT to provide 32,768 spectral channels at ~30.5 kHz (0.45 km/s velocity resolution) and 2) Using a 16k-pt polyphase filterbank (PFB) to provide 8,192 spectral channels with ~122 kHz resolution (1.8 km/s velocity resolution). Previous work extensively described the spectrometer system. In this paper we present added functionality and updates to the commissioned spectrometer. The changes include developments in system timing, metadata, firmware and data products.

Bradford, Brian↗

Updated assessment of TROPOMI NO2 and HCHO columns using airborne spectrometers during the MOOSE and TRACER-AQ field campaigns

Airborne spectrometer data offers the opportunity to evaluate satellite product performance without the impact of subpixel heterogeneity between the different satellite and ground-based measurement footprints. Previous measurements during the Long Island Sound Tropospheric Ozone Study were used to evaluate TROPOMI’s v1.3 NO2 product and found very strong relationships (r2=0.96) between the airborne spectrometer and TROPOMI with a systematic low bias mostly attributed to the coarse a priori profile assumption within the standard TROPOMI retrieval. This presentation will update that analysis using the most up-to-date version 2 TROPOMI NO2 product as well as expand analysis to the HCHO product. In summer 2021, NASA GeoCAPE Airborne Simulator (GCAS) collected measurements over southeast Michigan/western Ontario for the Michigan-Ontario Ozone Source Experiment (MOOSE) and Houston, Texas during the TRacking Aerosol Convection ExpeRiment – Air Quality (TRACER-AQ). Flight strategies for both deployments included repeated systematic sampling over common areas of interest coinciding with TROPOMI. During these flights, GCAS NO2 tropospheric columns are available at 250 m x 560 m resolution. Preliminary evaluation of GCAS NO2 retrievals with Pandora spectrometer data in Houston, Texas (3 sites) shows a median percent difference of 1.4% with an interquartile range of -15.5-14.9% (r2=0.72). Column HCHO was also retrieved at a slightly coarser resolution in Houston, Texas (750 m x 1680 m) showing distinct spatial patterns associated with secondary production through the oxidation of VOCs downwind of industrial facilities. Comparison to Pandora HCHO showed a low bias of ~25% (r2=0.29) with further investigation needed to identify the cause for this bias. This presentation will share how the GCAS/Pandora/TROPOMI NO2 and HCHO intercompare and will also extend analysis toward thinking about how these assets will contribute to the validation of future geostationary observations.

Laura Judd↗

The Third Flight of the Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS-3)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is the first X-ray slitless imaging spectrograph sounding rocket instrument designed to observe spectrally dispersed soft X-ray images of the solar corona over a wide field-of-view. During the first flight of MaGIXS (MaGIXS-1), occurred on 30 July 2021, several emission lines from coronal structures including X-ray bright points were observed. Further, MaGIXS-1 analysis also demonstrated the successful inversion of overlappograms using robust unfolding algorithms. Given the demonstrated success of MaGIXS-1, the second flight of the instrument with a simplified optical design, MaGIXS-2, is scheduled for 2024 to observe high temperature diagnostic emission lines. Results from MaGIXS-1 discovered dominant missing emission lines near 15A, arising from relatively cool plasma that peaks around 2 MK. This wavelength region hosts several closely spaced satellite lines of Fe XVII, Fe XVI and Fe XV ions, which are expected to be enhanced at lower temperatures and are currently unmodeled in the CHIANTI atomic database. This wavelength region offers one of the most unique diagnostics to measure electron temperature, as well as signatures of equilibrium state of the plasma in active regions, which has not been studied so far. The goal of MaGIXS-3 mission is the to determine coronal heating parameters, such as the spatial and temporal properties of coronal heating events, by measuring discriminating observations, such as electron temperature, effective temperature, density, abundance, and departures from thermal equilibrium of the plasma, by observing the Sun in the SXR wavelength range. To meet this goal, the MaGIXS instrument will be upgraded with a new X-ray telescope mirror that will provide higher spatial and spectral resolution and throughput, allowing for spectral lines to be observed at the relevant spatial and temporal scales. In addition, MaGIXS-3 will also carry The Resolving Inversion Context X-ray Spectrometer (TRICXS), a high dispersion Bragg crystal spectrometer to spectrally resolve the lines near 14.9 to 15.9A, critical to unlock the full diagnostic potential of this wavelength range. Here we will present the preliminary concept design of MaGIXS-3 and discuss the potential observations.

X-ray Imaging↗

The Next Generation Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS) Sounding Rocket Experiments

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket experiment that carries an X-ray slitless imaging spectrograph to observe spectrally dispersed soft X-ray (SXR) images of the solar corona over a wide field-of-view. The first flight of MaGIXS occurred on 30 July 2021, during which several emission lines from coronal structures including X-ray bright points were observed. Analysis of MaGIXS-1 data demonstrated the application of new inversion techniques and opened a new arena of inverting complex spectroheliogram data, which has spatial-spectral information overlapped. The second flight of MaGIXS, with a simplified optical design, is scheduled for 2024. The goal of MaGIXS-2 is to observe high temperature diagnostic emission lines within an active region core. MaGIXS-1 discovered dominant missing emission lines near 15Å wavelength region, which hosts several closely spaced satellite lines of Fe XVII, Fe XVI, and Fe XV ions, arising from relatively cool plasma that peaks near 2MK. These lines are expected to be enhanced at lower temperatures and offers one of the most unique diagnostics to measure electron temperature, as well as signatures of equilibrium state of the plasma in active regions, which has not been studied so far. The science goal of the third sounding rocket flight of MaGIXS is to determine coronal heating parameters, such as the spatial and temporal properties of coronal heating events, by measuring discriminating observations, such as electron temperature, effective temperature, density, abundance, and departures from thermal equilibrium of the plasma, by observing the Sun in the SXR wavelength range. For this, the MaGIXS instrument will be upgraded with a new X-ray telescope mirror that will provide higher spatial and spectral resolution and throughput, allowing for spectral lines to be observed at the relevant spatial and temporal scales. In addition, MaGIXS-3 will also carry The Resolving Inversion Context X-ray Spectrometer (TRICXS), a high dispersion Bragg crystal spectrometer to spectrally resolve the lines near 15Å, critical to unlock the full diagnostic potential of this wavelength range. Here we will present the preliminary concept design of MaGIXS-3 and discuss the potential observations.

X-ray Imaging↗

The Peregrine Ion Trap Mass Spectrometer (PITMS) Investigation Development and Pre-Flight Planning

The Peregrine Ion Trap Mass Spectrometer (PITMS) is a mass spectrometer instrument that operated during the Astrobotic Peregrine Mission-1 as part of the NASA Commercial Lunar Payload Services (CLPS) initiative. This paper describes the instrument and investigation design, development, and planning conducted by the PITMS team consisting of a successful partnership between NASA Goddard Space Flight Center (GSFC), The Open University (OU), NASA, and ESA. PITMS was designed to measure the abundance and temporal variability of volatile species in the near-surface lunar exosphere from a landed platform on the lunar surface. The PITMS instrument consisted of an ESA-provided Exospheric Mass Spectrometer (EMS; including sensor, electronics, controller, power supply boards) and a GSFC wrapper that provided structural elements, thermal control, and a deployable dust cover. PITMS was designed to operate as a passive sampler, where ambient gases would enter PITMS through an aperture, diffuse around the mass analyzer cavity, become ionized by electron impact and trapped in a radiofrequency field, then sequentially released to a detector to build a mass spectrum. PITMS was capable of measuring species with a massto-charge ratio (m/z) from 10 to 150 Da, with a mass resolution of approximately 0.5 amu. The PITMS science investigation was planned to be operated by GSFC with an international team of scientists. Though the mission did not achieve its lunar landing, information about the PITMS instrument and planning is provided to be able to understand and effectively use data that will be forthcoming from the investigation.

Barbara Cohen↗

Differentially pumped dual linear quadrupole ion trap mass spectrometer

The present disclosure provides a new tandem mass spectrometer and methods of using the same for analyzing charged particles. The differentially pumped dual linear quadrupole ion trap mass spectrometer of the present disclose includes a combination of two linear quadrupole (LQIT) mass spectrometers with differentially pumped vacuum chambers.

47 OTHER INSTRUMENTATION↗

Differentially pumped dual linear quadrupole ion trap mass spectrometer

The present disclosure provides a new tandem mass spectrometer and methods of using the same for analyzing charged particles. The differentially pumped dual linear quadrupole ion trap mass spectrometer of the present disclose includes a combination of two linear quadrupole (LQIT) mass spectrometers with differentially pumped vacuum chambers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-cone x-ray imaging Bragg crystal spectrometer

Embodiments provide a multi-cone X-ray imaging Bragg crystal spectrometer for spectroscopy of small x-ray sources with a well-defined spectral resolution. The spectrometer includes a glass substrate machined to a multi-cone form; and a thin crystal slab attached to the glass substrate, whereby the multi-cone X-ray imaging Bragg crystal spectrometer provides rotational symmetry of a ray pattern, providing for accurate imaging, for each wavelength in the spectral range of interest. One or more embodiments include a streak camera and/or a gated strip detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods for aligning a spectrometer

An example method for aligning a spectrometer is described herein. The spectrometer includes a radiation source, a crystal analyzer, and a detector that are all positioned on an instrument plane. The method includes rotating the crystal analyzer about an axis that is within the instrument plane and perpendicular to a rotation plane such that (i) a reciprocal lattice vector of the crystal analyzer is within the instrument plane or (ii) a component of the reciprocal lattice vector within the rotation plane is perpendicular to the instrument plane. An origin of the reciprocal lattice vector is located on the axis. The method further includes tilting the crystal analyzer or translating the detector such that the reciprocal lattice vector bisects a line segment that is bounded by the detector and the radiation source. Example spectrometers related to the example method are also disclosed.

Mortensen, Devon R.↗

Development of the Low Granularity Pair Spectrometer counters in Hall D at JLab

The pair spectrometer in the photon beam line of Hall D at JLab is designed to monitor the stability of photon flux and the relative tagging efficiency of the photon tagger via a well known electron-positron pair production measurement. The pair spectrometer consists of a thin foil converter, a dipole magnet, and two identical left and right arm detector packages. Each detector package covers the electron or position energy from 3 GeV to 6.25 GeV. It consists of a front detector array for fine position resolution and rear scintillating hodoscopes to provide fast timing to form the pair production trigger. This presentation will focus on the construction and testing of the Low-Granularity Pair Spectrometer counters.

Dzbenski, Nathan↗

Compact hyperspectral spectrometers based on semiconductor nanomembranes

Hyperspectral resonant cavity imaging spectrometers and imaging systems incorporating the resonant cavity spectrometers are provided. The spectrometers include an array of photodetectors based on photosensitive semiconductor nanomembranes disposed between two dielectric spacers, each of the dielectric spacers having a thickness gradient along a lateral direction, such that the resonant cavity height differs for different photodetectors in the array.

Ma, Zhenqiang↗

The SeaQuest spectrometer at Fermilab

The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell–Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets and four detector stations. The upstream magnet is a closed-aperture solid iron magnet which also serves as the beam dump, while the second magnet is an open aperture magnet. Each of the detector stations consists of scintillator hodoscopes and a high-resolution tracking device. The FPGA-based trigger compares the hodoscope signals to a set of pre-programmed roads to determine if the event contains oppositely-signed, high-mass muon pairs.

36 MATERIALS SCIENCE↗

Incident beamline design for a modern cold triple axis spectrometer at the High Flux Isotope Reactor

A modern cold triple axis spectrometer is being planned for the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Here, we describe the design of an incident beamline that will put a flux of ~ 10 8 $\frac {n}{cm^{2}s}$ on a sample with an area of 2 cm X 2 cm. It takes current physical constraints at HFIR into account and it can accommodate both single and multiplexed analyzer-detector secondary spectrometers and large superconducting magnets. The proposed incident beamline includes a multi-channel guide with horizontal focusing, a neutron velocity selector, components to facilitate an incident beam polarization option, and a double-focusing pyrolytic graphite monochromator. Here, this work describes the process of optimizing the guide system and monochromator and summarizes the expected performance of the incident beamline for non-polarized operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Forward fitting of experimental data from a NE213 neutron detector installed with the magnetic proton recoil upgraded spectrometer at JET

In this paper, we present the results obtained from the data analysis of neutron spectra measured with a NE213 liquid scintillator at JET. We calculated the neutron response matrix of the instrument combining MCNPX simulations, a generic proton light output function measured with another detector and the fit of data from ohmic pulses. For the analysis, we selected a set of pulses with neutral beam injection heating (NBI) only and we applied a forward fitting procedure of modeled spectral components to extract the fraction of thermal neutron emission. The results showed the same trend of the ones obtained with the dedicated spectrometer TOFOR, even though the values from the NE213 analysis were systematically higher. This discrepancy is probably due to the different lines of sight of the two spectrometers (tangential for the NE213, vertical for TOFOR). The uncertainties on the thermal fraction estimates were from 4 to 7 times higher than the ones from the TOFOR analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GOAmazon Thermal Desorption Chemical Ionization Mass Spectrometer

Ion abundance measured by Thermal Desorption Chemical Ionization Mass Spectrometer (using quadrupole mass spectrometer) Data file format: Column 1: date and time (UTC) Column 2: measurement uncertainty (units: integrated ion counts) Column 3: ion intensity (units: integrated ion counts) Column 4: 1 min SO2 mixing ratio in ppb Measurement uncertainty is +/- 0.2 ppb.

54 ENVIRONMENTAL SCIENCES↗