Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectral elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Mesh-based super-resolution of fluid flows with multiscale graph neural networks

A graph neural network (GNN) approach is introduced in this work which enables mesh-based three-dimensional super-resolution of fluid flows. In this framework, the GNN is designed to operate not on the full mesh-based field at once, but on localized meshes of elements (or cells) directly. To facilitate mesh-based GNN representations in a manner similar to spectral (or finite) element discretizations, a baseline GNN layer (termed a message passing layer, which updates local node properties) is modified to account for synchronization of coincident graph nodes, rendering compatibility with commonly used element-based mesh connectivities. Furthermore, the architecture is multiscale in nature, and is comprised of a combination of coarse-scale and fine-scale message passing layer sequences (termed processors) separated by a graph unpooling layer. The coarse-scale processor embeds a query element (alongside a set number of neighboring coarse elements) into a single latent graph representation using coarse-scale synchronized message passing over the element neighborhood, and the fine-scale processor leverages additional message passing operations on this latent graph to correct for interpolation errors. Demonstration studies are performed using hexahedral mesh-based data from Taylor–Green Vortex and backward-facing step flow simulations at Reynolds numbers of 1600 and 3200. Through analysis of both global and local errors, the results ultimately show how the GNN is able to produce accurate super-resolved fields compared to targets in both coarse-scale and multiscale model configurations. Reconstruction errors for fixed architectures were found to increase in proportion to the Reynolds number. Geometry extrapolation studies on a separate cavity flow configuration show promising cross-mesh capabilities of the super-resolution strategy.

Backward-facing step↗

Laser induced breakdown spectroscopy diagnosis of rare earth doped optical glasses

In the present work, rare earth (Nd, Eu, Er, Ho) doped oxyfluoroborate glasses were studied using laser induced breakdown spectroscopy (LIBS) technique. It has been observed that rare earth elements other than the doped one also reveal their presence in the spectrum. In addition the spectral lines of elements constituting the glass matrix have also been observed. Different plasma parameters such as plasma temperature and electron density have been estimated. It is concluded that the LIBS is a potential technique to identify simultaneously the light elements (B, O, F) as well as the heavy elements (Fe, Ba, Ca, Eu, Nd, Ho, Er) present in optical glasses.

74 ATOMIC AND MOLECULAR PHYSICS↗

DFT-FE – A massively parallel adaptive finite-element code for large-scale density functional theory calculations

We present an accurate, efficient and massively parallel finite-element code, DFT-FE, for large-scale ab-initio calculations (reaching ~100,000 electrons) using Kohn-Sham density functional theory (DFT). DFT-FE is based on a local real-space variational formulation of the Kohn-Sham DFT energy functional that is discretized using a higher-order adaptive spectral finite-element (FE) basis, and treats pseudopotential and all-electron calculations in the same framework, while accommodating non-periodic, semi-periodic and periodic boundary conditions. We discuss the main aspects of the code, which include, the various strategies of adaptive FE basis generation, and the different approaches employed in the numerical implementation of the solution of the discrete Kohn-Sham problem that are focused on significantly reducing the floating point operations, communication costs and latency. We demonstrate the accuracy of DFT-FE by comparing the energies, ionic forces and periodic cell stresses on a wide range of problems with popularly used DFT codes. Further, we demonstrate that DFT-FE significantly outperforms widely used plane-wave codes---both in CPU-times and wall-times, and on both non-periodic and periodic systems---at systems sizes beyond a few thousand electrons, with over 5-10 fold speedups in systems with more than 10,000 electrons. In conclusion, the benchmark studies also highlight the excellent parallel scalability of DFT-FE, with strong scaling demonstrated on up to 192,000 MPI tasks.

97 MATHEMATICS AND COMPUTING↗

Synthesis and Photophysical Study of New Green Fluorescent TPA Based Poly(azomethine)s

A series of poly(azomethine)s (PAMs) were synthesized from N{sup 1}-(4-aminophenyl)-N{sup 1}-(4-phenoxyphenyl)benzene-1,4-diamine (DA) and various dialdehydes to investigate the influence of structure of polymer chain and triphenylamine-based phenoxy pendant group on the optoelectronic properties. The structural characterization of the resulting poly(azomethine)s was carried out by solubility test, gel permeation chromatography, viscosity measurement, fourier transform infrared (FTIR) spectral and CHN elemental analysis. The photophysical and electrochemical properties of the materials were scrutinized by UV–vis, photoluminescence, time correlation photon counting spectral analysis (TCSP) and cyclic voltammetry. The thermal stability of the poly(azomethine)s was assessed by differential scanning calorimetry and thermogravimetric analysis found to be stable upto 300 °C. These polymers exhibit moderate inherent viscosity range from 0.99 to 1.15 g dL{sup − 1} and appreciable organosolubility. The presence of triphenylamine and azomethine (CH = N) linkage in our synthesized materials rendered them fluorescent, emitting green light upon excitation at 375 nm with quantum efficiencies of 3.9–8.5%. The pendant phenoxy group at para-position in new poly(azomethine)s has also lowered the onset oxidation potentials and elevated the HOMO levels. Additionally, the presence of conjugation increases the fluorescence time of the excited state in conjugated polymers which was found in the range 9.22–11.17 ns, sufficient to be use in future optoelectronic applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Forward modeling of reduced power spectra from three-dimensional K-space

We present results from a numerical forward model to evaluate one-dimensional reduced power spectral densities (PSDs) from arbitrary energy distributions in k-space. In this model, we can separately calculate the diagonal elements of the spectral tensor for incompressible axisymmetric turbulence with vanishing helicity. Given a critically balanced turbulent cascade with k{sub ∥}∼k{sub ⊥}{sup α} and α<1, we explore the implications on the reduced PSD as a function of frequency. The spectra are obtained under the assumption of Taylor’s hypothesis. We further investigate the functional dependence of the spectral index κ on the field-to-flow angle θ between plasma flow and background magnetic field from MHD to electron kinetic scales. We show that critically balanced turbulence asymptotically develops toward θ-independent spectra with a slope corresponding to the perpendicular cascade. This occurs at a transition frequency f{sub 2D}(L,α,θ), which is analytically estimated and depends on outer scale L, critical balance exponent α, and field-to-flow angle θ. We discuss anisotropic damping terms acting on the k-space distribution of energy and their effects on the PSD. Further, we show that the spectral anisotropies κ(θ) as found by Horbury et al. and Chen et al. in the solar wind are in accordance with a damped critically balanced cascade of kinetic Alfvén waves. We also model power spectra obtained by Papen et al. in Saturn’s plasma sheet and find that the change of spectral indices inside 9 R{sub s} can be explained by damping on electron scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Elemental analysis of slurry samples with laser induced breakdown spectroscopy

Direct analysis of wet slurry samples with laser induced breakdown spectroscopy (LIBS) is challenging due to problems of sedimentation, splashing, and surface turbulence. Also, water can quench the laser plasma and suppress the LIBS signal, resulting in poor sensitivity. The effect of water on LIBS spectra from slurries was investigated. As the water content decreased, the LIBS signal was enhanced and the standard deviation was reduced. To improve LIBS slurry analysis, dried slurry samples prepared by applying slurry on PVC coated slides were evaluated. Univariate and multivariate calibration was performed on the LIBS spectra of the dried slurry samples for elemental analysis of Mg, Si, and Fe. Calibration results show that the dried slurry samples give a good correlation between spectral intensity and elemental concentration.

54 ENVIRONMENTAL SCIENCES↗

Element- and momentum-resolved electronic structure of the dilute magnetic semiconductor manganese doped gallium arsenide

The dilute magnetic semiconductors have promise in spin-based electronics applications due to their potential for ferromagnetic order at room temperature, and various unique switching and spin-dependent conductivity properties. However, the precise mechanism by which the transition-metal doping produces ferromagnetism has been controversial. Here we have studied a dilute magnetic semiconductor (5% manganese-doped gallium arsenide) with Bragg-reflection standing-wave hard X-ray angle-resolved photoemission spectroscopy, and resolved its electronic structure into element- and momentum- resolved components. The measured valence band intensities have been projected into element-resolved components using analogous energy scans of Ga 3d, Mn 2p, and As 3d core levels, with results in excellent agreement with element-projected Bloch spectral functions and clarification of the electronic structure of this prototypical material. This technique should be broadly applicable to other multi-element materials.

36 MATERIALS SCIENCE↗

Spectral methods for problems in complex geometries

Techniques that permit the efficient application of spectral methods to solve problems in nearly arbitrary geometries are presented. These methods were found to be viable alternatives to finite difference and finite element processes. The spectral methods applied are extensions of the standard techniques of separation of variables to the solution of arbitrarily complicated problems.

Orszag, S. A.↗

Simulation of solar radiation absorption in vegetation canopies

A solar radiation canopy absorption model, including multiple scattering effects, was developed and tested for a lodgepole pine (Pinus contorta) canopy. Reflectance above the canopy, spectral transmittance to the ground layer, and geometric and spectral measurements of canopy elements were made. Relatively large differentials occurred in spectral absorption by canopy layers, especially in the photosynthetically active region, as a function of solar zenith angle. In addition, the proportion of total global irradiance absorbed by individual layers varied greatly as a function of solar zenith angle. However, absorption by the entire canopy system remained relatively constant.

Kimes, D. S.↗

X-Ray Microanalysis and Electron Energy Loss Spectrometry in the Analytical Electron Microscope: Review and Future Directions

This paper reviews and discusses future directions in analytical electron microscopy for microchemical analysis using X-ray and Electron Energy Loss Spectroscopy (EELS). The technique of X-ray microanalysis, using the ratio method and k(sub AB) factors, is outlined. The X-ray absorption correction is the major barrier to the objective of obtaining I% accuracy and precision in analysis. Spatial resolution and Minimum Detectability Limits (MDL) are considered with present limitations of spatial resolution in the 2 to 3 microns range and of MDL in the 0.1 to 0.2 wt. % range when a Field Emission Gun (FEG) system is used. Future directions of X-ray analysis include improvement in X-ray spatial resolution to the I to 2 microns range and MDL as low as 0.01 wt. %. With these improvements the detection of single atoms in the analysis volume will be possible. Other future improvements include the use of clean room techniques for thin specimen preparation, quantification available at the I% accuracy and precision level with light element analysis quantification available at better than the 10% accuracy and precision level, the incorporation of a compact wavelength dispersive spectrometer to improve X-ray spectral resolution, light element analysis and MDL, and instrument improvements including source stability, on-line probe current measurements, stage stability, and computerized stage control. The paper reviews the EELS technique, recognizing that it has been slow to develop and still remains firmly in research laboratories rather than in applications laboratories. Consideration of microanalysis with core-loss edges is given along with a discussion of the limitations such as specimen thickness. Spatial resolution and MDL are considered, recognizing that single atom detection is already possible. Plasmon loss analysis is discussed as well as fine structure analysis. New techniques for energy-loss imaging are also summarized. Future directions in the EELS technique will be the development of new spectrometers and improvements in thin specimen preparation. The microanalysis technique needs to be simplified and software developed so that the EELS technique approaches the relative simplicity of the X-ray technique. Finally, one can expect major improvements in EELS imaging as data storage and processing improvements occur.

Goldstein, J. I.↗

Unveiling Hidden Shake-Up Features in the Uranyl M 4 -Edge Spectrum

The M 4,5 -edge high energy resolution X-ray absorption near-edge structure (HR-XANES) spectra of actinyls offer valuable insights into the electronic structure and bonding properties of heavy-element complexes. To conduct a comprehensive spectral analysis, it is essential to employ computational methods that accurately account for relativistic effects and electron correlation. In this work, we utilize variational relativistic multireference configurational interaction methods to compute and analyze the X-ray M 4 -edge absorption spectrum of uranyl. By employing these advanced computational techniques, we achieve excellent agreement between the calculated spectral features and experimental observations. Moreover, the calculations unveil significant shake-up features, which arise from the intricate interplay between strongly correlated 3d core-electron and ligand excitations. This research provides important theoretical insights into the spectral characteristics of heavy-element complexes. Furthermore, it establishes the foundation for utilizing M 4,5 -edge spectroscopy as a means to investigate the chemical activities of such complexes. By leveraging this technique, we can gain a deeper understanding of the bonding behavior and reactivity of heavy-element compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theory and implementation of high-order adaptive hp methods for analysis of incompressible viscous flows

An account is given of 'smart' algorithms for CFD which change in structure and performance with during flow calculations to accommodate changing properties of the solution. Such algorithms prominently include adaptive FEM methods, which are designed to adjust mesh parameters for the control of numerical error; attention is presently given to those which change the mesh size h and the local spectral order p in order to achieve high accuracies with minimal numbers of degrees of freedom. These 'hp methods' produce exponentially convergent approximations through which flow features are resolved by automatically distributing element sizes and spectral orders. This leads to calculation of the local (elementwise) error in the approximation.

Oden, J. T.↗

Measuring Surface Bulk Elemental Composition on Venus

The extreme surface environment (462 C, 93 bars pressure) of Venus makes subsurface measurements of its bulk elemental composition extremely challenging. Instruments landed on the surface of Venus must be enclosed in a pressure vessel. The high surface temperatures also require a thermal control system to keep the instrumentation temperatures within their operational range for as long as possible. Since Venus surface probes can currently operate for only a few hours, it is crucial that the lander instrumentation be able to make statistically significant measurements in a short time. An instrument is described that can achieve such a measurement over a volume of thousands of cubic centimeters of material by using high energy penetrating neutron and gamma radiation. The instrument consists of a Pulsed Neutron Generator (PNG) and a Gamma-Ray Spectrometer (GRS). The PNG emits isotropic pulses of 14.1 MeV neutrons that penetrate the pressure vessel walls, the dense atmosphere and the surface rock. The neutrons induce nuclear reactions in the rock to produce gamma rays with energies specific to the element and nuclear process involved. Thus the energies of the detected gamma rays identify the elements present and their intensities provide the abundance of each element. The GRS spectra are analyzed to determine the Venus elemental composition from the spectral signature of individual major, minor, and trace radioactive elements. As a test of such an instrument, a Schlumberger Litho Scanner oil well logging tool was used in a series of experiments at NASA's Goddard Space Flight Center. The Litho Scanner tool was mounted above large (1.8 m x 1.8 m x.9 m) granite and basalt monuments and made a series of one-hour elemental composition measurements in a planar geometry more similar to a planetary lander measurement. Initial analysis of the results shows good agreement with target elemental assays

Venus↗

Data analysis and theoretical studies of the upper mesosphere and lower thermosphere

The work proposed under this grant came in three parts. The first involved extending our continuing study of electrodynamical feedback between the thermosphere/ionosphere and the magnetosphere. The second was a model-experiment comparison study of global dynamics and the third was a 'spectral energetics' analysis of tidal dissipation and energy exchange mechanisms. In the past year, progress has been made on all three topics. A paper is in press about electrodynamic feedback, and another is also in press on an element of the 'spectral energetics' analysis. Furthermore, a paper is being prepared on global dynamics variations in response to geomagnetic storms. In addition, much of the data needed for further studies on global dynamics is being prepared for inclusion in a relational database. This report is organized into several separate sections. In the next section, we present an introduction to the work that we are doing in this proposal. We discuss the progress made in our work and some results in section 3. In the last section, we summarize the work.

Burns, Alan↗

Visible and infrared linear detector arrays for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) instrument uses four separate focal plane assemblies consisting of line array detectors that are multiplexed to a common J-FET preamp using a FET switch multiplexing (MUX) technique. A 32-element silicon line array covers the spectral range from 0.41 to 0.70 microns. Three additional 64-element indium antimonide (InSb) line arrays cover the spectral range from 0.68 to 2.45 microns. The spectral sampling interval per detector element is nominally 9.8 nm, giving a total of 224 spectral channels. All focal planes operate at liquid nitrogen temperature and are housed in separate dewars. Electrical performance characteristics include a read noise of less than 1000 e(-) in all channels, response and dark nonuniformity of 5 percent peak to peak, and quantum efficiency of greater than 60 percent.

Bailey, Gary C.↗

Visible and infrared linear detector arrays for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) instrument uses four separate focal plane assemblies consisting of line array detectors that are multiplexed to a common J-FET preamp using a FET switch multiplexing (MUX) technique. A 32-element silicon line array covers the spectral range from 0.41 to 0.70 microns. Three additional 64-element indium antimonide (InSb) line arrays cover the spectral range from 0.68 to 2.45 microns. The spectral sampling interval per detector element is nominally 9.8 nm, giving a total of 224 spectral channels. All focal planes operate at liquid nitrogen temperature and are housed in separate dewars. Electrical performance characteristics include a read noise of less than 1000 e(-) in all channels, response and dark nonuniformity of 5 percent peak to peak, and quantum efficiency of greater than 60 percent.

Bailey, Gary C.↗