Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “solution deposition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Toward practical issues: Identification and mitigation of the impurity effect in glyme solvents on the reversibility of Mg plating/stripping in Mg batteries

Reversible electrochemical magnesium plating/stripping processes are important for the development of high-energy-density Mg batteries based on Mg anodes. Ether glyme solutions such as monoglyme (G1), diglyme (G2), and triglyme (G3) with the MgTFSI 2 salt are one of the conventional and commonly used electrolytes that can obtain the reversible behavior of Mg electrodes. However, the electrolyte cathodic efficiency is argued to be limited due to the enormous parasitic reductive decomposition and passivation, which is governed by impurities. In this work, a systematic identification of the impurities in these systems and their effect on the Mg deposition–dissolution processes is reported. The mitigation methods generally used for eliminating impurities are evaluated, and their beneficial effects on the improved reactivity are also discussed. By comparing the performances, we proposed a necessary conditioning protocol that can be easy to handle and much safer toward the practical application of MgTFSI 2 /glyme electrolytes containing impurities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anion Association Strength as a Unifying Descriptor for the Reversibility of Divalent Metal Deposition in Nonaqueous Electrolytes

Developing next-generation battery chemistries that move beyond traditional Li-ion systems is critical to enabling transformative advances in electrified transportation and grid-level energy storage. Here, we provide the first evidence for common descriptors for improved reversibility of metal plating/stripping in nonaqueous electrolytes for multivalent ion batteries. Focusing first on the specific role of chloride (Cl – ) in promoting electrochemical reversibility in multivalent systems, rotating disk (RDE) and ring-disk electrode (RRDE) investigations were performed utilizing a variety of divalent cations (Mg 2+ , Zn 2+ , and Cu 2+ ) and the bis-(trifluoromethane sulfonyl) imide (TFSI – ) anion. By introducing varying concentrations of Cl – , a cooperative effect is observed between TFSI – and Cl – that yields the more reversible behavior of mixed electrolytes relative to electrolytes containing only TFSI – . This effect is shown to be general for Mg, Zn, and Cu electrodeposition, and mechanistic understanding of the role of Cl – in improving reversibility of TFSI-based electrolytes is obtained through the combination of R(R)DE experimental results and density functional theory (DFT) evaluation of the redox activity and thermodynamic stability of various TFSI- and Cl-based solution complexes of metal ions. The cooperative anion effect is further generalized to other mixed-anion systems, where systematic variations in anion association strength predicted from DFT (i.e., Cl – > OTf – ≈ TFSI – > BF 4 – > PF 6 – ) yield corresponding trends in redox potentials and improvements of ≥200 mV in the reversibility of metal deposition/dissolution. These results identify anion association strength as a common descriptor for the reversibility of divalent metal anodes and suggest a set of general design principles for developing new electrolytes with improved activity and stability.

25 ENERGY STORAGE↗

Photovoltaics Research and Development: Device Architecture for Next-Generation CdTe PV. Cooperative Research and Development Final Report, CRADA Number CRD-17-00662

Despite remarkable efficiency improvements at the cell and module level, thin-film CdTe PV suffers from a significant voltage deficit compared with the ideal. The proposed solution is to build cells with fully depleted absorbers and with energy barriers front and back to direct electrons and holes in appropriate directions. Combined with minimal interfacial recombination, this approach, which is similar to the successful silicon HIT cells, circumvents the need for higher lifetimes and carrier concentration to achieve higher voltage, Colorado State is particularly well-positioned to the address the depleted absorbed architecture. It has robust single-vacuum closed-spaced-sublimation deposition chamber, currently being enhanced with new sources for CdTe alloys and grading. It has made reasonable-efficiency cells with absorbers as thin as 0.3 um, it has demonstrated electron reflection at the rear of the absorber with a continuous CdMgTe layer, it has replaced CdS with MgZnO, which has several advantages including tunable band offsets, and it has achieved 16.8% efficiency. It also has a mature suite of measurement equipment for cell evaluation and the experience to effectively analyze its results for refinement in cell fabrication. Several healthy collaborations will continue within the CdTe community.

14 SOLAR ENERGY↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Comments on 'Do ultrafine cloud condensation nuclei invigorate deep convection?'

Here we elaborated on the deficiencies associated with the theoretical arguments and model simulations in Grawbowski and Morrison (2020; GM20), and showed that the concept of convective invigoration by aerosols can be supported by both accurate theoretical analysis and explicit physics modeling with prognostic aerosols and supersaturation. Above the freezing level, droplet freezing itself does not change mass loading and the latent heat release resulting from freezing leads to an increase in the buoyancy. The derivation in GM20 is erroneous because of omitting the liquid water sink term. They also ignored the effect of enhanced latent heating from the subsequent growth processes (deposition and riming) after freezing. Regarding aerosol effect on condensational growth, the quasi-steady assumption for supersaturation as adopted in GM20 is invalidated especially when droplet number concentration is low and updraft is strong from both theoretical analysis and our bin microphysics modeling results. The quasi-steady assumption makes condensation independent of droplet number and size and therefore reduces the overall aerosol effects on cloud dynamics. Studying aerosol effects on clouds particularly deep convective clouds requires the exact solution of supersaturation. Any assumption imposed to supersaturation such as saturation adjustment and quasi-steady approximation leads to incorrect aerosol effects on diffusional growth. The exact supersaturation equation clearly shows that condensation depends on droplet number and size, and more droplets in the polluted clouds increase condensation (thus lower supersaturation), leading to enhanced buoyancy and updraft speeds.

Convective invigoration, deep convective clouds, a↗

Nanoscale friction of CVD single-layer MoS 2 with controlled defect formation

Two-dimensional (2D) layered nanomaterials such as graphene, molybdenum disulfide (MoS 2 ), or tungsten disulfide offer a promising solution in areas of solid-state lubrication, due to their excellent mechanical properties as well as low friction. However, defects can influence their friction and reduce their superior tribological properties. Thus, it is crucial to understand the effects of defects on sliding behavior in 2D nanomaterials, to foster a functional strategy for utilizing 2D nanomaterials as solid-state tribological films. In this study, frictional effects of defects, grain boundaries, and atomic-scale structural defects were explored on chemical vapor deposition (CVD) grown single layer MoS 2 . Selective patterning of defects into MoS 2 was accomplished via controlled irradiation of helium ions with varying ion doses. The friction of MoS 2 was characterized by friction force microscopy (FFM) and was found that friction depends on the defect formation controlled by helium ion irradiation. This approach offers a correlation between surface topography, defects and friction. Understanding the relative friction of MoS 2 in the presence of different levels of defects is foundational to studying tribological properties of a single layer MoS 2 at both nanoscales and macroscales.

36 MATERIALS SCIENCE↗

Direct and rapid uranium isotopic analysis of environmental sample swipes via microextraction – LS-APGD/Orbitrap mass spectrometry

Accurate and precise isotopic analysis of actinides collected on environmental sample swipes from within nuclear facilities is an important safeguarding measure for detecting undeclared materials and activities. Traditional isotope ratio (IR) analysis of actinides using a bulk digestion approach can be laborious and time-consuming. Recently, direct analysis of environmental swipe samples using a microextraction approach has been explored as an alternative to conventional bulk digestion methods. The present study further evaluates this approach for accurate and precise isotopic analysis of uranium (U) in cotton swipe samples using the liquid sampling-atmospheric pressure glow discharge (LS-APGD)/Orbitrap-FTMS Booster detection system. The instrumental parameters were optimized, and quantitative capabilities were demonstrated through excellent linearity (R2 = 0.99) across a deposited mass range of 1 to 500 ng, with a limit of detection of 90 pg (in a 2 × 4 mm region) for total U; well below typical U concentrations (ng–mg range) in environmental sample swipes. The 235U/238U ratio showed excellent accuracy (−0.3% relative difference from the certificate value), with ∼20× improvement over previous microextraction-Orbitrap methods. Precision (∼1% relative standard deviation) was also greatly enhanced by ∼5×. This study also demonstrates that figures of merit achieved with neat U solution were not highly degraded when various external interfering elements/matrices were introduced. Finally, the developed method was successfully applied to analyze practical swipe samples representative of laboratory and outdoor environments. The presented figures of merit and applicability to practical samples further validate the capability of the platform for rapid analysis (<7 minutes) of environmental swipe samples.

Shrestha, Suraj [Clemson University, SC]↗

Dissolution of poorly soluble uranyl phosphate phases in the Metaautunite Subgroup under uranyl peroxide cage cluster forming conditions

Uranyl phosphate minerals are widespread in uranium deposits and usually exhibit very low solubility in aqueous systems. Uranyl phosphates of the autunite group and metaautunite subgroup impact the mobility of uranium in the environment and have inspired groundwater remediation strategies that emphasize their low solubility. The importance of soluble uranium-bearing macro-anions, including nanoscale uranyl peroxide cage clusters, is largely unexplored relative to solubilization of normally low-solubility uranium minerals. Eight synthetic analogs of metaautunite subgroup minerals have been prepared and placed in various alkaline aqueous solutions containing hydrogen peroxide and tetraethylammonium hydroxide. Each uranyl phosphate studied has a topologically identical anionic sheet of uranyl square bipyramids and phosphate tetrahedra combined with various cations (Li + , Na + , K + , Rb + , Cs + , Mg 2+ , Ca 2+ , Ba 2+ ) and water in the interlayer. Uranyl peroxides formed under many of the experimental conditions examined, including solid studtite [(UO 2 )(O 2 )(H 2 O) 2 ](H 2 O) 2 and soluble uranyl peroxide cage clusters containing as many as 28 uranyl ions. Uranyl phosphate solids in contact with solutions in which uranyl peroxide cage clusters formed dissolved extensively or completely. The greatest dissolution of uranyl phosphates occurred in systems that contained cations with larger hydrated radii, Li + and Na + . The details of the uranium speciation in solution depended on the pH and counter cations provided from the interlayers of the uranyl phosphate solids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary Insights Into the Feasibility of Determining the Purification Date of Enriched Uranium by Direct Measurement of the 230 Th/ 234 U Ratio Using an All-Faraday Detector Configuration on the Neoma MC-ICP-MS

Rationale: Mass spectrometric measurement of the 230 Th/ 234 U ratio to calculate the purification age of enriched uranium is typically conducted via a combination of ion counters and faraday detectors, thus requiring an inter-detector calibration scheme. Here, our aim is to understand whether the pursuit of a simplified measurement scheme involving only faraday detectors is feasible. Methods: We investigate the possibility of determining U-Th model ages for two enriched uranium standards (NBL U630 and U850) by direct measurement of the 230 Th/ 234 U ratio (without chromatographic separation or isotope dilution) on a ThermoFisher Scientific Neoma MC-ICP-MS utilizing both solution and laser ablation (LA)-based sampling techniques and an all-faraday detector configuration. Results: For the solution mode analyses conducted on aliquots containing sub μg/mL total U, we produce composite average 230 Th/ 234 U model dates of May 19, 1988 (± 351 days), and March 26, 1961 (± 2.5 years) using the directly measured 230 Th/ 234 U ratios for the NBL U630 and U850 uranium standards, which have certified purification dates of June 6, 1988 (± 190 days), and December 31, 1957 (± 36.5 days), respectively. The ages produced by LA-based sampling of dried residues of the same standards deposited onto cotton TexWipes are less accurate and of poorer precision (June 23, 2004 ± 8.7 years for U630 and December 21, 1965 ± 7.9 years for U850) but still yield meaningful information in regards to the purification date. Conclusions: We believe that further refinement of the all faraday detector measurement approach to include development of a more robust Th/U relative sensitivity factor determination, signal cutoff selection, and data processing protocols will allow for this approach to be confidently applied to enriched uranium materials with unknown purification histories. Potential advantages of the method include the reduced sample handling and infrastructure requirements as well as the ability to simultaneously generate a broad picture of the uranium isotopic composition in tandem with the U-Th age determination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Manipulating Organic Semiconductor Morphology with Visible Light

A method is presented to manipulate the final morphology of roll-to-roll slot-die coated poly(3-hexylthiophene) (P3HT) by optically exciting the p-type polymer in solution while coating. These results provide a comprehensive picture of the entire knowledge chain, from demonstrating how to apply the authors’ method to a fundamental understanding of the changes in morphology and physical properties induced by exciting P3HT while coating. By combining results from density functional theory and molecular dynamics simulations with a variety of X-ray experiments, absorption spectroscopy, and THz spectroscopy, the relationship between morphology and physical properties of the thin film is demonstrated. Specifically, in P3HT films excited with light during deposition, changes in crystallinity and texture with more face-on orientation and increased out-of-plane charge mobility are observed.

36 MATERIALS SCIENCE↗

Surface Chemistry and Particle Morphology Changes in Pine Biomass under Indirect Thermal Gradients: Implications for Feed Screw Design

The conversion of biomass feedstocks into fuels and chemicals using fast pyrolysis is a promising approach to renewable energy. Feed screws that convey biomass to pyrolysis reactors, however, often encounter plugging. Indirect heating of the feed screw occurs due to contact with the pyrolysis chamber, resulting in a heating gradient ranging from ambient temperature (22 °C) to reactor temperature (500 °C). Given that major cell wall macromolecules, such as lignin, cellulose, and hemicellulose, begin to produce bio-oils and volatile resin acid compounds within this temperature gradient, we hypothesized that indirect heating during feed screw conveyance is sufficient to cause premature degradation of biomass. We characterized this degradation by observing increases in surface roughness, changes in overall particle morphology, and the production and deposition of bio-oils on biomass particle surfaces. Correlative analysis between optical in situ hot-stage microscopy, confocal Raman spectroscopy, and SEM analysis revealed that heating at temperatures as low as 375 °C caused significant increases in surface roughness, with large fissures forming between and within cell walls. Additionally, droplets of bio-oil were observed on particles, especially in the bark and cambium samples. This work suggests that these phenomena contribute to particle agglomeration, leading to feed screw plugging, and that engineering a solution to cool the feed screw could prevent particle agglomeration and reduce plugging incidents, thereby increasing biomass processing efficiency.

09 BIOMASS FUELS↗

Muon-induced fission of actinide nuclei

A negative muon captured by an actinide cascades down through the muonic atomic levels; deeply bound transitions can proceed via inverse internal conversion, depositing the muonic transition energy directly into the nucleus and, when the deposited energy exceeds the fission barrier, inducing prompt fission. Because the muon mean lifetime exceeds the saddle-to-scission timescale by orders of magnitude, the muon can survive the entire fission event as a 1⁢𝑠 spectator and ultimately attach to one or both of the emerging fragments. Its postscission attachment probability to the light fragment, 𝑃 𝐿 , can be used as a direct electromagnetic probe of fission dynamics on a timescale of 10 −21 s. In previous work, we introduced a three-dimensional lattice solution of the time-dependent Dirac equation coupled to the electromagnetic field generated by a fissioning nucleus and reported 𝑃 𝐿 for several actinides at a single dissipation strength. In this work, we extend that framework to a systematic survey of 232 Th , 238 U , and 240 Pu and implement a more realistic fission model which incorporates dynamic pairing correlations. We find that 𝑃 𝐿 falls steeply with the fragment charge asymmetry, a robust structural fingerprint of the fissioning system, while its dependence on nuclear dissipation is secondary and sensitive to the phenomenological friction prescription. These results establish 𝑃 𝐿 as a clean electromagnetic probe of fragment charge asymmetry and motivate a self-consistent, coordinate- and time-dependent treatment of nuclear dissipation as the natural next step.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-throughput synthesis and corrosion behavior of sputter-deposited nanocrystalline Al x (CoCrFeNi) 100-x combinatorial high-entropy alloys

High-entropy alloys (HEAs) are inherently complex and potentially span a vast composition space, making their research and discovery challenging. In the present study, high-throughput synthesis of an Al x (CoCrFeNi) 100-x combinatorial material library covering x = 4.5–40 atomic percent Al is achieved, using magnetron cosputtering. The effects of Al on the microstructure and corrosion behavior are investigated. With the increased amount of Al, crystal-structures of thin films transform from face-centered cubic (FCC) to body-centered cubic (BCC). Both the FCC and BCC thin films demonstrate a uniform elemental distribution. Corrosion characteristics of combinatorial samples immersed in the 3.5 wt% (wt%) NaCl solution are evaluated via electrochemical tests. Complementary X-ray photoelectron spectroscopy analysis reveals the compositional variation of passivated films formed on the sample surface after immersion. The results show that the Al x (CoCrFeNi) 100-x HEA thin films possess outstanding corrosion-resistant properties, but the resistance diminishes with the increasing Al content. The decreased corrosion resistance is revealed to be directly related to the constituents of passivated films.

36 MATERIALS SCIENCE↗

Ionic‐Liquid Free and Flexible Transistors Made of 2D Material Inks

The development of thin-film transistors (TFTs) using 2D materials is crucial for enabling scalable, low-cost, and flexible electronics. Currently, 2D TFTs with the highest performance have been achieved by using ionic-liquid gating (ILG), a technique suited for proof-of-concept studies. However, ILG suffers from slow switching speeds, temperature sensitivity, poor long-term stability, and integration challenges, making it unsuitable for practical use. Moreover, typical fabrication methods for 2D TFTs involve harsh conditions such as strong acids or high temperatures (>300 °C), limiting integration with flexible substrates. This work provides the first demonstration of an ILG-free, all-2D-material TFT fabricated onto a flexible substrate. Water-based graphene and hexagonal boron nitride (h-BN) inks are printed to deposit the electrodes and dielectric layers, respectively. The MoS 2 channel is produced via supramolecular interfacial self-assembly, yielding uniform, monolayer-rich films transferable to rigid and flexible substrates. The resulting TFTs operate below 3 V, exhibit negligible leakage current, and achieve field-effect mobilities up to 0.46 cm 2 V −1 s −1 (rising to 2.47 cm 2 V −1 s −1 with silver electrodes) measured under ambient conditions, while maintaining excellent mechanical flexibility. This work establishes a low-cost and scalable solution-processable platform for flexible electronics based on 2D materials that match requirements for practical applications.

2D materials↗

Multimodal sensor fusion for real-time standoff estimation in directed energy deposition

In Laser Powder-based Direct Energy Deposition (LP-DED) systems, achieving consistency, precision and quality of produced parts requires tight control over printing parameters. One of the critical parameters is the standoff distance. Maintaining an optimal standoff height is crucial for achieving correct laser power density and powder catchment efficiency, as both laser and powder streams are focused at this distance. Here, this study introduces a novel approach using multimodal sensor fusion to predict standoff height in real-time. The proposed system integrates two low-profile, cost-effective sensors: an RGB coaxial camera and a high frequency and high dynamic range microphone. By utilizing a simple fully connected neural network, trained on a limited dataset, data fusion of these sensors allowed for the real-time prediction of the standoff height. The results demonstrate high resolution and accuracy of the predictions across multiple geometries and a wide range of standoff heights. This approach offers a simple, and cost-effective solution for real-time standoff height monitoring and lays the groundwork for future integration into commercial LP-DED systems.

42 ENGINEERING↗

Nanoscopic Plugs Block Hydrogen Crossover in Submicron Thick Proton-Conducting SiO 2 Membranes for Water Electrolysis

Zero-gap electrolyzers based on submicron thick proton-conducting oxide membranes (POMs) represent a promising approach to increasing the efficiency of H 2 production from water electrolysis while moving away from conventional perfluorosulfonic acid (PFSA) membranes. A critical barrier to the commercialization of such electrolyzers is that the ultrathin nature of POMs, which is necessary to achieve low cell resistance, makes them more susceptible to defects that can lead to unacceptably high rates of H 2 crossover. Herein, we demonstrate an approach to mitigate this problem through selective deposition of carbon-containing silicon oxide (SiO x C y ) “nanoplugs” into the defects of submicron thick SiO 2 membranes using a facile electrochemically mediated deposition process. Selective deposition of nanoplugs within the defects was verified by multiple characterization techniques, while scanning electrochemical microscopy (SECM) was used to confirm selective plugging of H 2 -crossover hotspots associated with defects at identical locations. Thanks to the use of nanoplugs, the H 2 permeance of 250 nm thick SiO 2 membranes was reduced by 5 to 6 orders of magnitude compared to the unmodified atomic layer deposition (ALD) SiO 2 membranes while having negligible impact on the ionic resistance of the membrane. These plug-modified membranes also enabled safe and stable operation of a zero-gap full cell electrolysis cell, in contrast to cells lacking nanoplugs that produced anode effluent streams having H 2 concentrations near or exceeding the lower flammability limit (LFL) of H 2 . Furthermore, beyond water electrolysis, this defect-sealing strategy has the potential to be broadly implemented in other applications, such as fuel cells and flow batteries, offering a versatile solution to mitigate crossover-related performance losses.

ALD SiO2↗

Self Assembled Monolayers for Passivated Contacts

Passivated contacts mitigate defects typically encountered due metallization of solar cells. We deposit amorphous silicon (a-Si:H) on an oxidized silicon wafer via PECVD and anneal at high temperature to crystallize into polysilicon passivated contact. One drawback is the absorption of the polysilicon between grid fingers, so removal of this material is desirable to maximize Jsc. Alternatively, interdigitated back contact cells rely on a gap between n- and p- fingers, which is commonly etched to ensure electronic isolation. We utilize a self assembled monolayer (SAM) using hexamethyldisilazane (HMDS) as a precursor to pattern and etch amorphous silicon (a-Si:H) and polysilicon without the need for photoresist. Ultraviolet light exposure oxidizes the HMDS by photocleaving the organic groups [1] of the SAM leaving a patterned SiO2. Directly soaking this in TMAH will eventually etch the SAM and the silicon, where the SiO2 serves as an etch mask. Inversely, a dilute HF dip selectively etches this SiO2 and the SAM remains. A subsequent soak in TMAH selectively etches the underlying silicon, where the SAM serves as an etch mask. Importantly, we find that the SAM can remain intact for metallization, where we measure 10 mO-cm2 specific contact resistivity on n-type polysilicon.

passivation↗

Processability and Material Behavior of NiTi Shape Memory Alloys Using Wire Laser-Directed Energy Deposition (WL-DED)

Utilizing additive manufacturing (AM) techniques with shape memory alloys (SMAs) like NiTi shows great promise for fabricating highly flexible and functionally superior 3D metallic structures. Compared to methods relying on powder feedstocks, wire-based additive manufacturing processes provide a viable alternative, addressing challenges such as chemical composition instability, material availability, higher feedstock costs, and limitations on part size while simplifying process development. This study presented a novel approach by thoroughly assessing the printability of Ni-rich Ni55.94Ti (Wt. %) SMA using the wire laser-directed energy deposition (WL-DED) technique, addressing the existing knowledge gap regarding the laser wire-feed metal additive manufacturing of NiTi alloys. For the first time, the impact of processing parameters—specifically laser power (400–1000 W) and transverse speed (300–900 mm/min)—on single-track fabrication using NiTi wires in the WL-DED process was examined. An optimal range of process parameters was determined to achieve high-quality prints with minimal defects, such as wire dripping, stubbing, and overfilling. Building upon these findings, we printed five distinct cubes, demonstrating the feasibility of producing nearly porosity-free specimens. Notably, this study investigated the effect of energy density on the printed part density, impurity pick-up, transformation temperature, and hardness of the manufactured NiTi cubes. The results from the cube study demonstrated that varying energy densities (46.66–70 J/mm3) significantly affected the quality of the deposits. Lower to intermediate energy densities achieved high relative densities (>99%) and favorable phase transformation temperatures. In contrast, higher energy densities led to instability in melt pool shape, increased porosity, and discrepancies in phase transformation temperatures. These findings highlighted the critical role of precise parameter control in achieving functional NiTi parts and offer valuable insights for advancing AM techniques in fabricating larger high-quality NiTi components. Additionally, our research highlighted important considerations for civil engineering applications, particularly in the development of seismic dampers for energy dissipation in structures, offering a promising solution for enhancing structural performance and energy management in critical infrastructure.

Dabbaghi, Hediyeh↗