Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “refrigerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Cavitation data for hydraulic equipment

Development of cavitation B-factors for helium, parahydrogen, nitrogen, fluorine, oxygen, refrigerant 114, and water is discussed. B-factor is defined and numerical relationships are established. Mathematical models are included and alternative methods of determining B-factor are explained.

Hord, J.↗

Fill and vent quick disconnect

Hydraulic disconnect coupling on ground serving half of spacecraft refrigeration cooling system employs movable center stem for venting and closing nipple poppet. Self sealing poppet quickly connects cooling system to spacecraft without manual work. Recessed sealing surface insures open poppet when stem retracts.

Boerner, R. Y.↗

Magnetism, dimensional changes, and magnetic transitions in hydrated cesium manganese chloride

Dimensional changes (strain) along the three principal crystal axes of the antiferromagnet CsMnCl3-2H2O are studied as a function of magnetic field and temperature in the antiferromagnetic, spin flopped, and paramagnetic phases. Changes in dimensions through the phase transitions between the magnetic states are examined. By applying the molecular field model and utilizing all available information, magnetic properties of CsMnCl3-2H2O are determined. The possible usefulness of this material in a magnetic refrigeration cycle is evaluated.

Woollam, J. A.↗

Contamination character of materials in space technology testing.

Determination of the nature and degree of contamination of mirrors in a vacuum environment in the presence of UV irradiation by outgases from some materials that are candidates for use inside spacecraft and simulated spacecraft environments. A vacuum apparatus was developed for testing contamination of mirrors. Offgases from heated test materials are deposited on a refrigerated mirror, half of which is UV irradiated. Reflectance is measured between 1100 and 25,000 A. Thermofit RNF-100, insulated wire TRT-24-19-V-93, and Eccofoam FS and FPH gave heavier deposits on the nonirradiated mirror. Moxness MS60 SO8, Scotch Tape Y-9050, RTV-577, RTV-41, Stycast 1090, and Epon 934 and 828 gave heavier deposits on the irradiated mirror. Raychem wire 44/0411, polyimide tape X1156, Insulgrease G-640, High Vacuum Silicone Grease, and RTV-602 gave only slight deposits on the irradiated and nonirradiated areas of the mirror.

Coulson, D. M.↗

Fusion power for space propulsion.

Principles of operation, interplanetary orbit-to-orbit mission capabilities, technical problems, and environmental safeguards are examined for thermonuclear fusion propulsion systems. Two systems examined include (1) a fusion-electric concept in which kinetic energy of charged particles from the plasma is converted into electric power (for accelerating the propellant in an electrostatic thrustor) by the van de Graaf generator principle and (2) the direct fusion rocket in which energetic plasma lost from the reactor has a suitable amount of added propellant to obtain the optimum exhaust velocity. The deuterium-tritium and the deuterium/helium-3 reactions are considered as suitable candidates, and attention is given to problems of cryogenic refrigeration systems, magnet shielding, and high-energy particle extraction and guidance.

Roth, R.↗

Solar energy, its conversion and utilization

The work being carried out at the University of Florida Solar Energy and Energy Conversion Laboratory in converting solar energy, our only income, into other needed and useful forms of energy is described. A treatment such as this demonstrates, in proper perspective, how solar energy can benefit mankind with its many problems of shortages and pollution. Descriptions were given of the conversion processes, equipment, and performance. The testing of materials, solar water heating, space heating, cooking and baking, solar distillation, refrigeration and air-conditioning, work with the solar furnace, conversion to mechanical power, hot air engines, solar-heated sewage digestion, conversion to electricity, and other devices will be discussed.

Farber, E. A.↗

Stability of human sera collected for clinical chemistry determinations

Problems in collecting and shipping human sera for clinical chemical analyses affect their stability and require proper preservation methods. It is shown that glutamic pyruvate transaminase is very unstable and serum cannot be shipped unless the shipping time is carefully controlled and is less than two days under refrigeration. A limit of four days handling time and avoidance of light exposure are required in bilirubin testing of specimens. Addition of 11 mg of a 10 to 1 mixture of finely powdered sodium fluoride and thymol per ml of blood to preserve specimen stability en route to a central laboratory prevents glycolysis. A citrate buffer at pH 6.2 in serum to be tested for alkaline phosphatase lessens decline at room temperature.

Townsend, F. M.↗

Superconducting magnet for a Ku-band maser.

A superconducting magnet to provide a uniform magnetic field of up to 8000 G in a 1.14-cm gap for the 15.3-GHz (Ku-band) traveling wave maser is described. The magnet operates in a persistent mode in the vacuum environment of a closed-cycle helium refrigerator (4.5 K). The features of a superconducting switch, which has both leads connected to 4.5 K heat stations and thereby does not receive heat generated by the magnet charging leads, are described.

Berwin, R.↗

Improved thermal isolation for superconducting magnet systems

Closed-cycle refrigerating system for superconductive magnet and maser is operated in vacuum environment. Each wire leading from external power source passes through cooling station which blocks heat conduction. In connection with these stations, switch with small incandescent light bulb, which generates heat, is used to stop superconduction.

Wiebe, E. R.↗

Technique for direct measurement of magnetic entropy of solids: Results for dysprosium titanium oxide

A measurement technique was devised which permits direct observation of the magnetic entropy of solids as a function of applied magnetic field. Measurements were made of the magnetic entropy, in the temperature range 2 to 20 K, of polycrystalline samples of dysprosium titanium oxide (Dy2Ti2O7) to determine its suitability for use as the working substance of a magnetic refrigerator. Magnetization measurements were also made at 4.2 K and below to provide additional information on the nature of the compound. The measurements indicated that crystalline electric fields perturbed the ground state of the dysprosium ions, removed the 16-fold degeneracy predicted by Hund's rules, and left only a twofold degeneracy in its place. A positive, temperature independent contribution to the magnetization was observed in the saturation region, which indicated that the doublet ground-state wave function was perturbed by a nearby unpopulated upper energy level.

Flood, D. J.↗

Space shuttle/food system. Volume 2, Appendix C: Food cooling techniques analysis. Appendix D: Package and stowage: Alternate concepts analysis

The relative penalties associated with various techniques for providing an onboard cold environment for storage of perishable food items, and for the development of packaging and vehicle stowage parameters were investigated in terms of the overall food system design analysis of space shuttle. The degrees of capability for maintaining both a 40 F to 45 F refrigerated temperature and a 0 F and 20 F frozen environment were assessed for the following cooling techniques: (1) phase change (heat sink) concept; (2) thermoelectric concept; (3) vapor cycle concept; and (4) expendable ammonia concept. The parameters considered in the analysis were weight, volume, and spacecraft power restrictions. Data were also produced for packaging and vehicle stowage parameters which are compatible with vehicle weight and volume specifications. Certain assumptions were made for food packaging sizes based on previously generated space shuttle menus. The results of the study are shown, along with the range of meal choices considered.

Source record↗

Shuttle active thermal control system development testing. Volume 8: Tube anomaly investigation

A modular radiator system projected for use on the space shuttle has been tested. During thermal vacuum testing of the radiator panels leaks developed in the coolant fluid tubes containing the Freon 21 refrigerant. An analysis of thermal vacuum test conditions revealed that the test anomaly consisted of trapped Freon 21 fluid between frozen tube corners colder than the remainder of the panel. The trapped fluid expanded on further warming, causing high pressures to develop in the tubes. The pressure was sufficient to induce tube ruptures. Metallurgical analysis showed that concentric extrusion holes and heat treatment of the aluminum alloy to the -T6 condition would have prevented the ruptures. Thermal analysis indicates that attaching the tube corners to the radiator fin could eliminate the fluid trapping.

Reed, M. W.↗

Applications of cryogenics in electron microscopy

Description of research and development efforts which resulted in a high-voltage cryoelectron microscope system capable of consistent operation at 1.8 to 4.2 K. Attention is given to the design and operation of superconducting objective lenses providing enhanced resolution during longer exposure times at lower beam intensities (thus reducing radiation damage of specimens). A specific system described combines a closed-cycle superfluid helium refrigerator integrated with a modified 200 kV electron microscope. Consistent resolutions of 8 to 16 A are attained with significantly reduced radiation damage, contamination, and thermal noise in prolonged vibration-free examination of specimens at temperatures from 1.8 to 4.2 K. Applications in specific disciplines are discussed, including membrane ultrastructure, cryobiology, microelectronics, and general superconductivity research.

Fernandez-Moran, H.↗

A Ge/Li/ spectrometer for gamma ray astronomy

A space-borne instrument to measure the spectral and temporal characteristics of astronomical gamma rays in the .05 to 10 Mev energy range is described. The spectrometer consists of four 60 cc Ge(Li) detectors with an energy resolution of 2.5 Kev (FWHM) at 1.33 Mev. The Ge(Li) detectors are actively shielded with CsI(Na) for angular collimation and background reduction. Cooling of the Ge(Li) detectors to 88 K for orbital lifetimes of up to two years is provided by a two-stage solid subliming refrigerator.

Hicks, D. B.↗

A wire/extensometer method for measuring small displacements

A method has been developed for making precise point-to-point displacement measurements on critical structures under structural, thermal, or gravity loading. The technique consists of attaching the gauge to the structure at one point, and connecting it to a second point on the structure by a thin (0.25 mm) tungsten wire. The wire provides a dual function: in addition to physically connecting the gauge to a remote point, it provides a calibrating function. Tests have demonstrated that measurements can be made within a micron over a length of a meter or two, even in the presence of severe thermal shock, such as exposure to a sun gun or to a refrigerant spray.

Wilson, M. W.↗

Design and performance of Skylab thermal/environmental control system

The function of the thermal/environmental control systems was to provide a comfortable thermal environment for the crew, to cool electronic components, to supply a controlled oxygen/nitrogen atmosphere, and to remove moisture, carbon dioxide, odors, and trace contaminants from the atmosphere. A separate refrigeration system was used to chill and freeze food and biomedical samples and to provide cold water for drinking. This paper describes system design and compares in-flight performance to preflight predictions. A discussion of in-flight anomalies and corrective actions is also included.

Hopson, G. D.↗

Magnetization and magnetic entropy of Dy2Ti2O7

Isothermal measurements of the magnetic entropy, magnetization, and differential susceptibility of Dy2Ti2O7 have been made. Absolute values of magnetic entropy have been determined as a function of applied magnetic field for several temperatures in the range 2-20 K, and several isofield lines in the magnetic entropy-temperature plane have been determined. Magnetization measurements, which extended into the saturation region, yield a powder-average magnetic moment of about 4.7 Bohr magnetons per ion. A van Vleck contribution to M was also observed. The results are consistent with the assumption of a nearly pure Jz equals + or - 15/2 ground-state Kramers doublet for the Dy(+++) ion. Comments on the suitability of Dy2Ti2O7 for use in a magnetic refrigerator cycling between 4.2 and 20 K are included.

Flood, D. J.↗

Low-noise K(u)-band receiver input system

Improved maser and superconducting magnet, which operates in vacuum of closed-cycle helium refrigerator, comprise a low-noise, reliable, field-operational receiver input system.

Berwin, R. W.↗