Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Improving Weak Lensing Mass Map Reconstructions using Gaussian and Sparsity Priors: Application to DES SV

Mapping the underlying density field, including non-visible dark matter, using weak gravitational lensing measurements is now a standard tool in cosmology. Due to its importance to the science results of current and upcoming surveys, the quality of the convergence reconstruction methods should be well understood. We compare three methods: Kaiser–Squires (KS), Wiener filter, and Glimpse. Kaiser–Squires is a direct inversion, not accounting for survey masks or noise. The Wiener filter is well-motivated for Gaussian density fields in a Bayesian framework. Glimpse uses sparsity, aiming to reconstruct non-linearities in the density field. We compare these methods with several tests using public Dark Energy Survey (DES) Science Verification (SV) data and realistic DES simulations. The Wiener filter and Glimpse offer substantial improvements over smoothed Kaiser–Squires with a range of metrics. Both the Wiener filter and Glimpse convergence reconstructions show a 12 per cent improvement in Pearson correlation with the underlying truth from simulations. To compare the mapping methods’ abilities to find mass peaks, we measure the difference between peak counts from simulated ΛCDM shear catalogues and catalogues with no mass fluctuations (a standard data vector when inferring cosmology from peak statistics); the maximum signal-to-noise of these peak statistics is increased by a factor of 3.5 for the Wiener filter and 9 for Glimpse. With simulations, we measure the reconstruction of the harmonic phases; the phase residuals’ concentration is improved 17 per cent by Glimpse and 18 per cent by the Wiener filter. The correlationbetween reconstructions from data and foreground redMaPPer clusters is increased 18 per cent by the Wiener filter and 32 per cent by Glimpse.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutron reconstruction via blips in liquid argon time projection chambers

Neutrons are important final-state particles in neutrino interactions, yet they are not considered or reconstructed in most current neutrino liquid argon time projection chamber (LArTPC) physics analyses. In this paper, we present a simulation-based proof-of-concept study of neutron reconstruction in a generic LArTPC detector. Leveraging isolated, MeV-scale energy deposits, or blips, from neutron inelastic scattering, and using realistic blip response from published experimental results, we demonstrate the capability to identify neutrons and to reconstruct the direction and energy of the final-state neutron system in sub-GeV neutrino interactions. We then explore how neutron-related blip attributes can be used to improve physics studies of neutrino interactions, such as enhancing neutrino-antineutrino separation in atmospheric neutrinos and reverse-horn-current beam neutrinos. This study provides an initial quantification of LArTPC neutron reconstruction capabilities, which we expect to improve with future advancements in blip reconstruction, identification, and classification algorithms, as well as the modeling of neutrons.

Morquecho, Miguel Hernandez [Univ. of Minnesota, M↗

Size Effect of Local Current-Voltage Characteristics of MX 2 Nanoflakes: Local Density of States Reconstruction from Scanning Tunneling Microscopy Experiments

Local current-voltage characteristics for low-dimensional transition-metal dichalcogenides (LDTMD), as well as the reconstruction of their local density of states (LDOS) from scanning tunneling microscopy (STM) experiments, are of fundamental interest and can be useful for advanced applications. Most of the existing models either have limited applicability for complex-shaped LDTMDs (e.g., those based on the Simmons approach) or require solving of an ill-defined integral equation to deconvolute the unknown LDOS (e.g., those based on the Tersoff approach). Using a serial expansion of the Tersoff formulas, we propose a flexible method to reconstruct the LDOS from local current-voltage characteristics measured in STM experiments. We establish a set of key physical parameters, which characterize the tunneling current of a STM-probe–sample contact and the sample LDOS expanded in Gaussian functions. Using a direct variational method coupled with probabilistic analysis, we determine these parameters from the STM experiments for MoS2 nanoflakes with different numbers of layers. The main result is the reconstruction of the LDOS in a relatively wide energy range around the Fermi level, which allows us to gain insight into the local band structure of LDTMDs. The reconstructed LDOS reveal pronounced size effects for the single-layer, two-layer, and three-layer MoS 2 nanoflakes, which we relate to the low dimensionality and strong bending or corrugation of the nanoflakes. We hope that the proposed elaboration of the Tersoff approach, allowing LDOS reconstruction, will be of critical interest for the quantitative description of STM experiments and also of use to better understand the microscopic physical aspects of the surface, strain, and bending contributions to the LDTMDs’ electronic properties.

42 ENGINEERING↗

Machine learning for improved current-density reconstruction from two-dimensional vector magnetic images

The reconstruction of electrical current densities from magnetic field measurements is an important technique with applications in materials science, circuit design, quality control, plasma physics, and biology. Analytic reconstruction methods exist for planar currents, but break down in the presence of high-spatial-frequency noise or large standoff distance, restricting the types of systems that can be studied. Here, we demonstrate the use of a deep convolutional neural network for current density reconstruction from two-dimensional images of vector magnetic fields acquired by a quantum diamond microscope . Trained network performance significantly exceeds analytic reconstruction for data with high noise or large standoff distances. This machine learning technique can perform quality inversions on lower-signal-to-noise-ratio data, significantly reducing the data collection time and permitting reconstructions of weaker and three-dimensional current sources. Published by the American Physical Society 2025

Reed, Niko R. (ORCID:0009000305222403)↗

A Generic Guiding Principle for the Prediction of Metal-Induced Reconstructions of Compound Semiconductor Surfaces

We have performed extensive and systematical ab initio calculations to substantiate a recently proposed generalized electron counting (GEC) rule that governs the rich patterns of compound semiconductor reconstruction induced by metal adsorption. In this rule, the metal adsorbates serve as an electron bath, either donating or accepting the right number of electrons, with which the binary host system chooses a specific reconstruction under the classical electron counting rule, and meanwhile, the adsorbates stay in their optimal valency. The GEC rule is applied to different GaAs surfaces deposited by various classes of metal adsorbates, leading to a number of possible reconstructions, which can be further confirmed by first-principles calculations and/or experiments. The alkali metal adsorption on the GaAs(110) surface up to the saturate coverage is a perfect example of the GEC rule. The application of the GEC rule to the prototype system of Mn/GaAs(001) not only predicts possible reconstruction patterns over a wide range of coverage, but also provides an underlying link between the reconstruction structures and the local magnetic moments of the metal adsorbates. In Au/GaAs(100), we demonstrate the application of the GEC rule to those systems where metal adsrobates form covalent bonds with the substrate. The GEC rule, as a generic principle, is expected to be applicable to more metal-adsorbed compound semiconductor surfaces. PACS numbers: 68.35.-p, 68.43.Bc, 75.70.-i

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reconstructing patchy reionization with deep learning

The precision anticipated from next-generation cosmic microwave background (CMB) surveys will create opportunities for characteristically new insights into cosmology. Secondary anisotropies of the CMB will have an increased importance in forthcoming surveys, due both to the cosmological information they encode and the role they play in obscuring our view of the primary fluctuations. Quadratic estimators have become the standard tools for reconstructing the fields that distort the primary CMB and produce secondary anisotropies. While successful for lensing reconstruction with current data, quadratic estimators will be suboptimal for the reconstruction of lensing and other effects at the expected sensitivity of the upcoming CMB surveys. In this paper we describe a convolutional neural network, ResUNet-CMB, that is capable of the simultaneous reconstruction of two sources of secondary CMB anisotropies, gravitational lensing and patchy reionization. Furthermore, we show that the ResUNet-CMB network significantly outperforms the quadratic estimator at low noise levels and is not subject to the lensing-induced bias on the patchy reionization reconstruction that would be present with a straightforward application of the quadratic estimator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advancing set-conditional set generation: Diffusion models for fast simulation of reconstructed particles

The computational intensity of detector simulation and event reconstruction poses a significant difficulty for data analysis in collider experiments. This challenge inspires the continued development of machine learning techniques to serve as efficient surrogate models. We propose a fast emulation approach that combines simulation and reconstruction. In other words, a neural network generates a set of reconstructed objects conditioned on input particle sets. To make this possible, we advance set-conditional set generation with diffusion models. Using a realistic, generic, and public detector simulation and reconstruction package (COCOA), we show how diffusion models can accurately model the complex spectrum of reconstructed particles inside jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstructing baryon oscillations: A Lagrangian theory perspective

Recently Eisenstein and collaborators introduced a method to 'reconstruct' the linear power spectrum from a nonlinearly evolved galaxy distribution in order to improve precision in measurements of baryon acoustic oscillations. We reformulate this method within the Lagrangian picture of structure formation, to better understand what such a method does, and what the resulting power spectra are. We show that reconstruction does not reproduce the linear density field, at second order. We however show that it does reduce the damping of the oscillations due to nonlinear structure formation, explaining the improvements seen in simulations. Our results suggest that the reconstructed power spectrum is potentially better modeled as the sum of three different power spectra, each dominating over different wavelength ranges and with different nonlinear damping terms. Finally, we also show that reconstruction reduces the mode-coupling term in the power spectrum, explaining why miscalibrations of the acoustic scale are reduced when one considers the reconstructed power spectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of the calorimetric and kinematic methods of neutrino energy reconstruction in disappearance experiments

To be able to achieve their physics goals, future neutrino-oscillation experiments will need to reconstruct the neutrino energy with very high accuracy. In this work, we analyze how the energy reconstruction may be affected by realistic detection capabilities, such as energy resolutions, efficiencies, and thresholds. This allows us to estimate how well the detector performance needs to be determined a priori in order to avoid a sizable bias in the measurement of the relevant oscillation parameters. We compare the kinematic and calorimetric methods of energy reconstruction in the context of two ν μ → ν μ disappearance experiments operating in different energy regimes. For the calorimetric reconstruction method, we find that the detector performance has to be estimated with an O(10%) accuracy to avoid a significant bias in the extracted oscillation parameters. Thus, in the case of kinematic energy reconstruction, we observe that the results exhibit less sensitivity to an overestimation of the detector capabilities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Relevance Vector Machine Image Reconstruction Algorithm for Electrical Capacitance Tomography With Explicit Uncertainty Estimates

We present a Relevance Vector Machine (RVM) based algorithm for electrical capacitance tomography (ECT) applications that can concurrently provide image reconstruction results and uncertainty estimates about the reconstruction. To illustrate the RVM operation in ECT, we simulate typical ECT scenarios, making explicit the connection between the reconstructed pixel values and the corresponding uncertainty estimates in each case. We compare the RVM reconstruction performance with that of the Iterative Landweber Method (ILM) and the least absolute shrinkage and selection operator (LASSO) in all the considered scenarios. The results show that, in addition to the key advantage of providing uncertainty measures, RVM can achieve similar reconstruction results with either lower or similar computational complexity.

42 ENGINEERING↗

Advancing the Frontiers of Deep Learning for Low-Dose 3D Cone-Beam CT Reconstruction

X-ray computed tomography (CT) is an important noninvasive medical imaging modality for studying the structural details of internal organs. Image reconstruction in CT is an inverse problem of recovering an object's internal structure from the absorption profile of X-ray beams (sinogram) measured using a detector. The classical variational approach for CT reconstruction minimizes an energy functional using an appropriate iterative algorithm. Motivated by the success of deep learning (DL), researchers have begun to leverage training data and enhanced computing capabilities in recent years to produce high-fidelity reconstructed images. Nonetheless, much of the academic research in DL algorithms for CT has focused primarily on the two-dimensional setting (with simplified forward operators and noise model) for proofs-of-concept, and a comprehensive benchmarking of various classical and data-driven CT reconstruction approaches has not beenundertaken. The key objective of our CT reconstruction grand challenge was to promote methodological advancements for both classical and DL-based approaches for clinical CT with a reasonably accurately simulated 3D CT forward operator and noise model. We have utilized the publicly available LIDC-IDRI dataset and simulated sinograms and FDK images corresponding to two dose levels (clinical- and low-dose, constituting two tracks of the challenge) starting from the normal-dose images as the ground truth. In this paper, we summarize the motivation, context, and results of our challenge, and highlight the future research directions in DL for clinical CT.

X-ray tomography↗

A Multi-Branch Decoder Network Approach to Adaptive Temporal Data Selection and Reconstruction for Big Scientific Simulation Data

A key challenge in scientific simulation is that the simulation outputs often require intensive I/O and storage space to store the results for effective post hoc analysis. This article focuses on a quality-aware adaptive temporal data selection and reconstruction problem where the goal is to adaptively select simulation data samples at certain key timesteps in situ and reconstruct the discarded samples with quality assurance during post hoc analysis. This problem is motivated by the limitation of current solutions that a significant amount of simulation data samples are either discarded or aggregated during the sampling process, leading to inaccurate modeling of the simulated phenomena. Two unique challenges exist: 1) the sampling decisions have to be made in situ and adapted to the dynamics of the complex scientific simulation data; 2) the reconstruction error must be strictly bounded to meet the application requirement. To address the above challenges, we develop DeepSample , an error-controlled convolutional neural network framework, that jointly integrates a set of coherent multi-branch deep decoders to effectively reconstruct the simulation data with rigorous quality assurance. The results on two real-world scientific simulation applications show that DeepSample significantly outperforms other state-of-the-art methods on both sampling efficiency and reconstructed simulation data quality.

Zhang, Yang↗

3D reconstruction of a patient-specific surface model of the proximal femur from calibrated x-ray radiographs: A validation study

Twenty-three femurs (one plastic bone and twenty-two cadaver bones) with both nonpathologic and pathologic cases were considered to validate a statistical shape model based technique for three-dimensional (3D) reconstruction of a patient-specific surface model from calibrated x-ray radiographs. The 3D reconstruction technique is based on an iterative nonrigid registration of the features extracted from a statistically instantiated 3D surface model to those interactively identified from the radiographs. The surface models reconstructed from the radiographs were compared to the associated ground truths derived either from a 3D CT-scan reconstruction method or from a 3D laser-scan reconstruction method and an average error distance of 0.95 mm were found. Compared to the existing works, our approach has the advantage of seamlessly handling both nonpathologic and pathologic cases even when the statistical shape model that we used was constructed from surface models of nonpathologic bones.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method

Purpose: To generalize and experimentally validate a novel algorithm for reconstructing the 3D pose (position and orientation) of implanted brachytherapy seeds from a set of a few measured 2D cone-beam CT (CBCT) x-ray projections. Methods: The iterative forward projection matching (IFPM) algorithm was generalized to reconstruct the 3D pose, as well as the centroid, of brachytherapy seeds from three to ten measured 2D projections. The gIFPM algorithm finds the set of seed poses that minimizes the sum-of-squared-difference of the pixel-by-pixel intensities between computed and measured autosegmented radiographic projections of the implant. Numerical simulations of clinically realistic brachytherapy seed configurations were performed to demonstrate the proof of principle. An in-house machined brachytherapy phantom, which supports precise specification of seed position and orientation at known values for simulated implant geometries, was used to experimentally validate this algorithm. The phantom was scanned on an ACUITY CBCT digital simulator over a full 660 sinogram projections. Three to ten x-ray images were selected from the full set of CBCT sinogram projections and postprocessed to create binary seed-only images. Results: In the numerical simulations, seed reconstruction position and orientation errors were approximately 0.6 mm and 5 deg., respectively. The physical phantom measurements demonstrated an absolute positional accuracy of (0.78{+-}0.57) mm or less. The {theta} and {phi} angle errors were found to be (5.7{+-}4.9) deg. and (6.0{+-}4.1) deg., respectively, or less when using three projections; with six projections, results were slightly better. The mean registration error was better than 1 mm/6 deg. compared to the measured seed projections. Each test trial converged in 10-20 iterations with computation time of 12-18 min/iteration on a 1 GHz processor. Conclusions: This work describes a novel, accurate, and completely automatic method for reconstructing seed orientations, as well as centroids, from a small number of radiographic projections, in support of intraoperative planning and adaptive replanning. Unlike standard back-projection methods, gIFPM avoids the need to match corresponding seed images on the projections. This algorithm also successfully reconstructs overlapping clustered and highly migrated seeds in the implant. The accuracy of better than 1 mm and 6 deg. demonstrates that gIFPM has the potential to support 2D Task Group 43 calculations in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method of dose reconstruction for moving targets compatible with dynamic treatments

Purpose: To develop a method that allows a commercial treatment planning system (TPS) to perform accurate dose reconstruction for rigidly moving targets and to validate the method in phantom measurements for a range of treatments including intensity modulated radiation therapy (IMRT), volumetric arc therapy (VMAT), and dynamic multileaf collimator (DMLC) tracking. Methods: An in-house computer program was developed to manipulate Dicom treatment plans exported from a TPS (Eclipse, Varian Medical Systems) such that target motion during treatment delivery was incorporated into the plans. For each treatment, a motion including plan was generated by dividing the intratreatment target motion into 1 mm position bins and construct sub-beams that represented the parts of the treatment that were delivered, while the target was located within each position bin. For each sub-beam, the target shift was modeled by a corresponding isocenter shift. The motion incorporating Dicom plans were reimported into the TPS, where dose calculation resulted in motion including target dose distributions. For experimental validation of the dose reconstruction a thorax phantom with a moveable lung equivalent rod with a tumor insert of solid water was first CT scanned. The tumor insert was delineated as a gross tumor volume (GTV), and a planning target volume (PTV) was formed by adding margins. A conformal plan, two IMRT plans (step-and-shoot and sliding windows), and a VMAT plan were generated giving minimum target doses of 95% (GTV) and 67% (PTV) of the prescription dose (3 Gy). Two conformal fields with MLC leaves perpendicular and parallel to the tumor motion, respectively, were generated for DMLC tracking. All treatment plans were delivered to the thorax phantom without tumor motion and with a sinusoidal tumor motion. The two conformal fields were delivered with and without portal image guided DMLC tracking based on an embedded gold marker. The target dose distribution was measured with a radiochromic film in the moving rod and compared with the reconstructed doses using gamma tests. Results: Considerable interplay effects between machine motion and target motion were observed for the treatments without tracking. For nontracking experiments, the mean 2 mm/2% gamma pass rate over all investigated scenarios was 99.6% between calculated and measured doses. For tracking experiments, the mean gamma pass rate was 99.4%. Conclusions: A method for accurate dose reconstruction for moving targets with dynamic treatments was developed and experimentally validated in a variety of delivery scenarios. The method is suitable for integration into TPSs, e.g., for reconstruction of the dose delivered to moving tumors or calculation of target doses delivered with DMLC tracking.

60 APPLIED LIFE SCIENCES↗

Improved proton computed tomography by dual modality image reconstruction

Purpose: Proton computed tomography (CT) is a promising image modality for improving the stopping power estimates and dose calculations for particle therapy. However, the finite range of about 33 cm of water of most commercial proton therapy systems limits the sites that can be scanned from a full 360° rotation. In this paper the authors propose a method to overcome the problem using a dual modality reconstruction (DMR) combining the proton data with a cone-beam x-ray prior. Methods: A Catphan 600 phantom was scanned using a cone beam x-ray CT scanner. A digital replica of the phantom was created in the Monte Carlo code Geant4 and a 360° proton CT scan was simulated, storing the entrance and exit position and momentum vector of every proton. Proton CT images were reconstructed using a varying number of angles from the scan. The proton CT images were reconstructed using a constrained nonlinear conjugate gradient algorithm, minimizing total variation and the x-ray CT prior while remaining consistent with the proton projection data. The proton histories were reconstructed along curved cubic-spline paths. Results: The spatial resolution of the cone beam CT prior was retained for the fully sampled case and the 90° interval case, with the MTF = 0.5 (modulation transfer function) ranging from 5.22 to 5.65 linepairs/cm. In the 45° interval case, the MTF = 0.5 dropped to 3.91 linepairs/cm For the fully sampled DMR, the maximal root mean square (RMS) error was 0.006 in units of relative stopping power. For the limited angle cases the maximal RMS error was 0.18, an almost five-fold improvement over the cone beam CT estimate. Conclusions: Dual modality reconstruction yields the high spatial resolution of cone beam x-ray CT while maintaining the improved stopping power estimation of proton CT. In the case of limited angles, the use of prior image proton CT greatly improves the resolution and stopping power estimate, but does not fully achieve the quality of a 360° proton CT scan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging

Purpose: 4D cone beam CT (4D-CBCT) has been utilized in radiation therapy to provide 4D image guidance in lung and upper abdomen area. However, clinical application of 4D-CBCT is currently limited due to the long scan time and low image quality. The purpose of this paper is to develop a new 4D-CBCT reconstruction method that restores volumetric images based on the 1-min scan data acquired with a standard 3D-CBCT protocol. Methods: The model optimizes a deformation vector field that deforms a patient-specific planning CT (p-CT), so that the calculated 4D-CBCT projections match measurements. A forward-backward splitting (FBS) method is invented to solve the optimization problem. It splits the original problem into two well-studied subproblems, i.e., image reconstruction and deformable image registration. By iteratively solving the two subproblems, FBS gradually yields correct deformation information, while maintaining high image quality. The whole workflow is implemented on a graphic-processing-unit to improve efficiency. Comprehensive evaluations have been conducted on a moving phantom and three real patient cases regarding the accuracy and quality of the reconstructed images, as well as the algorithm robustness and efficiency. Results: The proposed algorithm reconstructs 4D-CBCT images from highly under-sampled projection data acquired with 1-min scans. Regarding the anatomical structure location accuracy, 0.204 mm average differences and 0.484 mm maximum difference are found for the phantom case, and the maximum differences of 0.3–0.5 mm for patients 1–3 are observed. As for the image quality, intensity errors below 5 and 20 HU compared to the planning CT are achieved for the phantom and the patient cases, respectively. Signal-noise-ratio values are improved by 12.74 and 5.12 times compared to results from FDK algorithm using the 1-min data and 4-min data, respectively. The computation time of the algorithm on a NVIDIA GTX590 card is 1–1.5 min per phase. Conclusions: High-quality 4D-CBCT imaging based on the clinically standard 1-min 3D CBCT scanning protocol is feasible via the proposed hybrid reconstruction algorithm.

60 APPLIED LIFE SCIENCES↗

Assessment of volumetric noise and resolution performance for linear and nonlinear CT reconstruction methods

Purpose: For nonlinear iterative image reconstructions (IR), the computed tomography (CT) noise and resolution properties can depend on the specific imaging conditions, such as lesion contrast and image noise level. Therefore, it is imperative to develop a reliable method to measure the noise and resolution properties under clinically relevant conditions. This study aimed to develop a robust methodology to measure the three-dimensional CT noise and resolution properties under such conditions and to provide guidelines to achieve desirable levels of accuracy and precision. Methods: The methodology was developed based on a previously reported CT image quality phantom. In this methodology, CT noise properties are measured in the uniform region of the phantom in terms of a task-based 3D noise-power spectrum (NPS{sub task}). The in-plane resolution properties are measured in terms of the task transfer function (TTF) by applying a radial edge technique to the rod inserts in the phantom. The z-direction resolution properties are measured from a supplemental phantom, also in terms of the TTF. To account for the possible nonlinearity of IR, the NPS{sub task} is measured with respect to the noise magnitude, and the TTF with respect to noise magnitude and edge contrast. To determine the accuracy and precision of the methodology, images of known noise and resolution properties were simulated. The NPS{sub task} and TTF were measured on the simulated images and compared to the truth, with criteria established to achieve NPS{sub task} and TTF measurements with <10% error. To demonstrate the utility of this methodology, measurements were performed on a commercial CT system using five dose levels, two slice thicknesses, and three reconstruction algorithms (filtered backprojection, FBP; iterative reconstruction in imaging space, IRIS; and sinogram affirmed iterative reconstruction with strengths of 5, SAFIRE5). Results: To achieve NPS{sub task} measurements with <10% error, the number of regions of interest needed to be greater than 65. To achieve TTF measurements with <10% error, the contrast-to-noise ratio of the edge needed to be ≥15, achievable by averaging multiple slices across the same edge. The NPS{sub task} measured on a commercial CT system showed IR's reduced noise (IRIS, 30% and SAFIRE5, 55%) and “waxier” texture (peak frequencies: FBP, 0.25 mm{sup −1}; IRIS, 0.23 mm{sup −1}; and SAFIRE5, 0.16 mm{sup −1}). The TTF measured within the axial plane showed improved in-plane resolution with SAFIRE5 at the TTF 50% frequency, f{sub 50} (FBP, 0.36–0.41 mm{sup −1}; SAFIRE5, 0.37–0.46 mm{sup −1}). The TTF measured along the axial direction showed improved z-direction resolution with thinner slice thickness (f{sub 50}: 0.6 mm, 0.35–0.79 mm{sup −1}; 1.5 mm, 0.22–0.3 mm{sup −1}) and with SAFIRE5 (f{sub 50}: FBP, 0.35–0.52 mm{sup −1}; SAFIRE5, 0.42–0.79 mm{sup −1}). Both in-plane and z-direction resolution of SAFIRE5 showed strong dependency on contrast, reflecting SAFIRE5's nonlinearity. Conclusions: A methodology was developed to measure three-dimensional CT noise and resolution properties for iterative reconstruction, especially at challenging measurement conditions with low contrast and high image noise. The methodology also demonstrated its utility for evaluating commercial CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗