Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Effect of moisture on the fatigue behavior of graphite/epoxy composite laminates

The form of the moisture distribution in the specimen (gradient and flat profile) was considered to establish the influence of accelerated moisture conditioning on fatigue behavior. For the gradient specimens having an average moisture content of 1.4 percent, fatigue life was reduced by a factor of 8 at all stress levels investigated. Corresponding reduction in fatigue life for the flat moisture profile specimens at the same average moisture content was comparatively smaller, being about a factor of 5 from the value in dry specimens. X-ray radiographic analysis of damage accumulation in compression-compression fatigue revealed interlaminar cracking to be the dominant mode of failure responsible for the observed enhanced cyclic degradation of moisture-conditioned specimens. This finding was corroborated by the observed systematic reduction in interlaminar shear strength as a function of moisture content, which, in turn, increased the propensity for delamination under cyclic compressive loads. Residual strength measurements on cycled specimens indicated significant strength reductions at long lives, particularly in moisture conditioned specimens.

Ramani, S. V.↗

Iodine imaging using spectral analysis

Existing radiographic imaging systems provide images which represent an integration or averaging over the energy spectrum. In order to provide noninvasive angiography it is necessary to image the relatively small amounts of iodine which are available following an intravenous administration. This is accomplished by making use of the special spectral characteristics of iodine. Two methods will be presented. One involves a special grating for encoding the iodine information in the form of a fine line pattern. This is subsequently decoded to provide images of iodinated structures which are otherwise almost invisible. The second method utilizes a scanned X-ray beam which is rapidly switched in the high energy region. In this region, iodine experiences significant variations in the attenuation coefficient while bone and soft tissue do not. An efficient and accurate X-ray detector can be used with scanned X-ray beams. This provides a high degree of sensitivity enabling the visualization of small vessels containing relatively dilute iodine.

Macovski, A.↗

Dosimetric considerations in dental applications

The integration of the Lixiscope into dental procedures was studied and compared with conventional dental radiographic techniques. It was found that through the use of intraoral sealed sources in conjunction with microchannel plate technology, the Lixiscope gives increased diagnostic information with decreased radiation dosage.

Goble, J. C.↗

SPAR 5 experiment no. 74-30 agglomeration in immiscible liquids

The influence of gravity, cooling rate, and composition on the macro-and microstructure of liquid phase immiscible alloys were researched. Aluminum indium alloys of compositions 30, 40, 70, and 90 weight percent indium were processed aboard two sounding rocket flights, SPAR 2 and SPAR 5. Radiographic and metallographic examination of the SPAR 2 flight and ground base samples showed the expected separation at lg of the ground base alloys into indium rich and aluminum rich layers. The flight alloys produced an aluminum rich core surrounding by indium rich metal. The results obtained from the SPAR 5 40 and 70 weight percent indium alloys were essentially identical to those from SPAR 2. The 30 and 90 weight percent indium alloys also showed massive separation into configuration similar to the 40 and 70 weight percent indium alloys. The 90 weight percent indium alloy showed additional evidence that surface tension induced droplet migration had occurred in this alloy which could at least in part account for the observed structures.

Gelles, S.↗

Structures of immiscible Al-In alloys solidified under microgravity conditions

Four samples of the immiscible Al-In system having monotectic and hypermonotectic compositions were solidified under microgravity during the NASA-SPAR IX flight of January 20th, 1981. The experimental thermal and physico-chemical conditions actually achieved have been analysed. Radiographic and metallographic observations of the samples show a non-regular dispersed primary phase inside the monotectic matrix. These observations are commented on the basis of capillarity and solidification aspects.

Potard, C.↗

An assessment of buffer strips for improving damage tolerance of composite laminates at elevated temperature

Buffer strips greatly improve the damage tolerance of graphite/epoxy laminates loaded in tension. Graphite/polyimide buffer strip panels were made and tested to determine their residual strength at ambient and elevated (177 C) temperature. Each panel was cut in the center to represent damage. Panels were radiographed and crack-opening displacements were recorded to indicate fracture, fracture arrest, and the extent of damage in the buffer strip after arrest. All panels had the same buffer strip spacing and width. The buffer strip material was 0 deg S-glass/PMR-15. The buffer strips were made by replacing narrow strips of the 0 deg graphite plies with strips of the 0 deg S-glass on either a one-for-one or a two-for-one basis. Half of the panels were heated to 177 + or - 3 C before and during the testing. Elevated temperature did not alter the fracture behavior of the buffer configuration.

Bigelow, C. A.↗

The application of fracture control to a weld specification

An approach used on the external tank (ET) portion of the Space Shuttle Program which employs fracture control to establish defect acceptance criteria in a welding specification is discussed. Weld acceptance criteria developed for the ET fabricated from 2219 aluminum are demonstrated using as an example one of the actual ET welds. A table of weld grades as a function of acceptable defect length is presented. The design drawing specifies the weld grade for a particular weld; then the inspector uses the grade to determine the defect length for radiographic and penetrant acceptance of the weld. By allowing each weld to be judged by its own defect requirement instead of using the tightest requirement, the number of weld repairs has been minimized, resulting in lower cost with no compromise in performance.

Bolstad, D. A.↗

Ultraviolet images of M101 - Observations of dust and inferences on the metallicity

Since extreme Population I dominates three rocketborne telescope UV images of the Sc I galaxy NGC 5457, the delineation of the spiral structure is sharper than that of ground photographs. The UV pictures, in which the H II regions appear as reflection nebulae and illumine the nearby dust, reveal faint arms which, although correlated with the 21 cm H I radiograph, are only marginally detectable on deep visual photographs. The surface brightness of the arms is explainable in terms of UV light scattering off dust from hot stars and bright H II regions, in which case the dust would have extinction properties and a dust-to-gas ratio similar to that in the solar neighborhood and would in addition suggest that the NGC 5457 outer arm metal content is similar to that of the galaxy.

Stecher, T. P.↗

Tolerance requirements to prevent fluid leakage in the crucible/plunger MEA experiment MPS 770030

Molten Al-In leaked unexpectedly out of the crucible of a proposed MEA materials processing in space experiment. The molten metals use a spring loaded plunger to eliminate most free surfaces. The critical criteria necessary to initiate flow and the rate of fluid flow into the crucible/plunger annulus is calculated. Experimental in situ X-radiographs are interpreted according to the calculations. A note on possible effects of capillary flow if wetting occurs between crucible/plunger and liquids is included.

Rathz, T. J.↗

Experimental and analytical investigation of the fracture processes of boron/aluminum laminates containing notches

Experimental results for five laminate orientations of boron/aluminum composites containing either circular holes or crack-like slits are presented. Specimen stress-strain behavior, stress at first fiber failure, and ultimate strength were determined. Radiographs were used to monitor the fracture process. The specimens were analyzed with a three-dimensional elastic-elastic finite-element model. The first fiber failures in notched specimens with laminate orientation occurred at or very near the specimen ultimate strength. For notched unidirectional specimens, the first fiber failure occurred at approximately one-half of the specimen ultimate strength. Acoustic emission events correlated with fiber breaks in unidirectional composites, but did not for other laminates. Circular holes and crack-like slits of the same characteristic length were found to produce approximately the same strength reduction. The predicted stress-strain responses and stress at first fiber failure compared very well with test data for laminates containing 0 deg fibers.

Johnson, W. S.↗

Fracture behavior of hybrid composite laminates

The tensile fracture behavior of 15 center-notched hybrid laminates was studied. Three basic laminate groups were tested: (1) a baseline group with graphite/epoxy plies, (2) a group with the same stacking sequence but where the zero-deg plies were one or two plies of S-glass or Kevlar, and (3) a group with graphite plies but where the zero-deg plies were sandwiched between layers of perforated Mylar. Specimens were loaded linearly with time; load, far field strain, and crack opening displacement (COD) were monitored. The loading was stopped periodically and the notched region was radiographed to reveal the extent and type of damage (failure progression). Results of the tests showed that the hybrid laminates had higher fracture toughnesses than comparable all-graphite laminates. The higher fracture toughness was due primarily to the larger damage region at the ends of the slit; delamination and splitting lowered the stress concentration in the primary load-carrying plies. A linear elastic fracture analysis, which ignored delamination and splitting, underestimated the fracture toughness. For almost all of the laminates, the tests showed that the fracture toughness increased with crack length. The size of the damage region at the ends of the slit and COD measurements also increased with crack length.

Kennedy, J. M.↗

In situ trace element microanalysis

The use of particle-track-radiography and X-ray- fluorescence techniques in the in situ measurement of trace (less than 1000 ppm) elements in single mineral phases of polished sections is surveyed, and examples of their application to ordinary, carbonaceous and enstatite chondrites are provided. Radiographic methods surveyed include fission-track radiography (for U, Th, and Pu-244), alpha radiography using nuclear reactions (for Li and B), alpha autoradiography (for Bi and Pb), and beta autoradiography (for several elements in synthetic or biological samples). Two X-ray-fluorescence methods are compared: (1) photon-induced X-ray emission (PIXE), and (2) the potential use of synchrotron radiation. The latter is shown to allow much greater sensitivity than current PIXE technology and a much broader range of elements than particle-track radiography: the ppm analysis of 10-micron grains for all elements heavier than Na. These advantages are seen as balancing the high cost of accelerator use.

Burnett, D. S.↗

Solidification of hypermonotectic Al-In alloys under microgravity conditions

Four samples of the Al-In system having monotectic and hypermonotectic compositions that were solidified under microgravity during the NASA-SPAR IX flight of January 20, 1981, are considered. The experimental thermal and physicochemical conditions that were actually achieved are analyzed. Radiographic and metallographic observations of the samples reveal a nonregular dispersed primary phase inside the monotectic matrix. These observations are discussed in relation to capillarity and solidification aspects. A key finding is the preservation of a certain degree of dispersion of the indium primary phase. This result differs fundamentally from the results obtained under microgravity conditions on the same system and compositions (Gelles and Markworth, 1980; Alborn and Loehberg, 1979). The results are seen as clearly establishing that the space environment can be used to obtain dispersed structures from hypermonotectic alloys.

Potard, C.↗

Failure analysis of a graphite/epoxy laminate subjected to bolt bearing loads

Quasi-isotropic graphite/epoxy laminates (T300/5208) were tested under bolt bearing loads to study failure modes, strengths, and failure energy. Specimens had a range of configurations to produce failures by the three nominal failure modes: tension, shearout, and bearing. Radiographs were made after damage onset and after ultimate load to examine the failure modes. Also, the laminate stresses near the bolt hole calculated for each test specimen configuration, and then used with a failure criterion to analyze the test data. Failures involving extensive bearing damage were found to dissipate significantly more energy than tension dominated failures. The specimen configuration influenced the failure modes and therefore also influenced the failure energy. In the width-to-diameter ratio range of 4 to 5, which is typical of structural joints, a transition from the tension mode to the bearing mode was shown to cause a large increase in failure energy. The failure modes associated with ultimate strength were usually different from those associated with the damage onset. Typical damage sequences involved bearing damage onset at the hole boundary followed by tension damage progressing from the hole boundary.

Crews, J. H., Jr.↗

Mechanical behavior of carbon-carbon composites

A general background, test plan, and some results of preliminary examinations of a carbon-carbon composite material are presented with emphasis on mechanical testing and inspection techniques. Experience with testing and evaluation was gained through tests of a low modulus carbon-carbon material, K-Karb C. The properties examined are the density - 1.55 g/cc; four point flexure strength in the warp - 137 MPa (19,800 psi) and the fill - 95.1 MPa (13,800 psi,) directions; and the warp interlaminar shear strength - 14.5 MPa (2100 psi). Radiographic evaluation revealed thickness variations and the thinner areas of the composite were scrapped. The ultrasonic C-scan showed attenuation variations, but these did not correspond to any of the physical and mechanical properties measured. Based on these initial tests and a survey of the literature, a plan has been devised to examine the effect of stress on the oxidation behavior, and the strength degradation of coated carbon-carbon composites. This plan will focus on static fatigue tests in the four point flexure mode in an elevated temperature, oxidizing environment.

Rozak, G. A.↗

Buffer strips in composites at elevated temperature

The composite material 'buffer strip' concept is presently investigated at elevated temperatures for the case of graphite/polyimide buffer strip panels using a (45/0/45/90)2S layup, where the buffer strip material was 0-deg S-glass/polyimide. Each panel was loaded in tension until it failed, and radiographs and crack opening displacements were recorded during the tests to determine fracture onset, fracture arrest, and the extent of damage in the buffer strip after crack arrest. At 177 + or - 3 C, the buffer strips increased the panel strength by at least 40 percent in comparison with panels without buffer strips. Compared to similar panels tested at room temperature, those tested at elevated temperature had lower residual strengths, but higher failure strains.

Bigelow, C. A.↗

X-radiography of slices of the Allende Meteorite

A 2.2 kg fragment of the Allende Meteorite was derinded and sliced by bandsawing. Several X-radiographs were made of all slices. The following features are resolved: grains of blocky troilite (bright spots), troilite rimmed chondrules (bright halos), chondrules with central vugs (dim halos), white aggregates (dark patches), and dark inclusions (medium dark patches). The number of FeS grains larger than about 0.5 mm is one per 6 + or - 1 gram of this fragment. Their concentration appears to be uniform at the 1 kg weight level, but is not uniform at the 100 g level. The number of FeS rimmed chondrules is one per 10 g. Their concentration is also nonuniform at the 100 g weight level. The number of white aggregates is roughly one per 20 g. These disc shaped objects show a distinct preferred orientation of the axis orthogonal to the plane of the disc. Chondrules with central vugs are numerous. Linear and curved arrays of chondrules, up to a few cm long, were observed. An interpretation of the observed features is given.

Smith, M. J.↗

NDE for heat engine ceramics

Radiographic, ultrasonic, and scanning laser acoustic microscopy (SLAM) techniques were used to characterize silicon nitride and silicon carbide MOR bars in various stages of fabrication. Conventional and microfocus x-ray techniques were found capable of detecting minute high density inclusions in as-received powders, green compacts, and fully densified specimens. Significant density gradients in sintered bars were observed by radiography, ultrasonic velocity, and SLAM. Ultrasonic attenuation was found sensitive to microstructural variations due to grain and void morphology and distribution. SLAM was also capable of detecting voids, inclusions, and cracks in finished test bars. It was determined that thermoacoustic microscopy techniques have promise for application to green and densified ceramics.

Klima, S. J.↗