Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quadrupoles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Analysis of useful ion yield for the Mg dopant in GaN by quadrupole—SIMS

The authors present a quantitative secondary ion mass spectrometry (SIMS) analysis of the useful ion yield of magnesium dopant in a gallium nitride matrix. A quadrupole SIMS instrument was used to analyze an Mg-doped GaN sample grown by metal organic chemical vapor deposition. Oxygen (O2+) was used as the primary ion beam and its energy was varied in the range from 0.5 to 5 kV with and without oxygen flooding near the sample. The results of the analysis can be used to determine the primary beam energies for optimal magnesium sensitivity.

Senevirathna, M. K. Indika (ORCID:0000000243575029↗

Polarization enhanced Nuclear Quadrupole Resonance with an atomic magnetometer

Nuclear Quadrupole Resonance (NQR) has been demonstrated for the detection of 14-N in explosive compounds. Application of a material specific radio-frequency (RF) pulse excites a response typically detected with a wire- wound antenna. NQR is non-contact and material specific, however fields produced by NQR are typically very weak, making demonstration of practical utility challenging. For certain materials, the NQR signal can be increased by transferring polarization from hydrogen nuclei to nitrogen nuclei using external magnetic fields. This polarization enhancement (PE) can enhance the NQR signal by an order of magnitude or more. Atomic magnetometers (AM) have been shown to improve detection sensitivity beyond a conventional antenna by a similar amount. AM sensors are immune to piezo-electric effects that hamper conventional NQR, and can be combined to form a gradiometer for effective RF noise cancellation. In principle, combining polarization enhancement with atomic magnetometer detection should yield improvement in signal-to-noise ratio that is the product of the two methods, 100-fold or more over conventional NQR. However both methods are even more exotic than traditional NQR, and have never been combined due to challenges in operating a large magnetic field and ultra-sensitive magnetic field sensor in proximity. Furthermore we present NQR with and without PE with an atomic magnetometer, demonstrating signal enhancement greater than 20-fold for ammonium nitrate. We also demonstrate PE for PETN using a traditional coil for detection with an enhancement factor of 10. Experimental methods and future applications are discussed.

47 OTHER INSTRUMENTATION↗

Nuclear quadrupole resonance spectroscopy with a femtotesla diamond magnetometer

Radio frequency (RF) magnetometers based on nitrogen vacancy centers in diamond are predicted to offer femtotesla sensitivity, but previous experiments were limited to the picotesla level. We demonstrate a femtotesla RF magnetometer using a diamond membrane inserted between ferrite flux concentrators. The device provides ~300-fold amplitude enhancement for RF magnetic fields from 70 kHz to 3.6 MHz, and the sensitivity reaches ~70 fT√s at 0.35 MHz. The sensor detected the 3.6-MHz nuclear quadrupole resonance (NQR) of room-temperature sodium nitrite powder. The sensor’s recovery time after an RF pulse is ~35 μs, limited by the excitation coil’s ring-down time. The sodium-nitrite NQR frequency shifts with temperature as -1.00±0.02 kHz/K, the magnetization dephasing time is T 2 *=887±51 μs, and multipulse sequences extend the signal lifetime to 332±23 ms, all consistent with coil-based studies. Our results expand the sensitivity frontier of diamond magnetometers to the femtotesla range, with potential applications in security, medical imaging, and materials science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simplest photonuclear reactions accompanied by the excitation of isovector giant dipole and quadrupole resonances: Semimicroscopic description

A semimicroscopic approach based on the continuum version of the random-phase approximation (CRPA) and on a semiphenomenological inclusion of the fragmentation effect is applied to describing cross sections for photoabsorption and direct plus semidirect and inverse reactions accompanied by the excitation of isovector giant dipole and quadrupole resonances. In addition to the spinless part of the Landau-Migdal interaction and a partly self-consistent phenomenological mean field of the nucleus, that version of the approach which is used here takes into account isovector separable velocity-dependent forces, as well as the effect of the fragmentation shift of the giant-resonance energy. The results obtained by calculating various features of the aforementioned cross sections for a number of magic and semimagic medium-mass nuclei are compared with respective experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A mass quadrupole spectrometry investigation on proton emission by nanosecond laser ablation

A nanosecond pulsed Nd:YAG laser operating at the fundamental wavelength of 1064 nm and at an intensity of about 10{sup 10} W/cm{sup 2} was employed to irradiate hydrogenated polymers in vacuum. The produced plasma was characterized in terms of thermal and Coulomb interactions evaluating the equivalent temperature and the acceleration voltage developed in the non-equilibrium plasma core. Particles emission along the normal to the target surface was investigated by measuring, with the Hiden EQP 300 mass quadrupole spectrometer, ion energy distributions and fitting experimental data with the “Coulomb-Boltzmann-shifted” function. Time-of-flight technique was employed in order to measure the proton energy and yield. A comparison between experimental results is presented and discussed, with a special regard to the protons emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Large-Aperture High-Field Nb 3 Sn Quadrupole Magnets for HiLumi

The HL-LHC Inner Triplet quadrupole magnets use Nb 3 Sn superconductor for the first time in a particle accelerator. Coil peak field, forces, and stored energy density are significantly higher than in previous accelerator magnets. The original design addressed all these challenges. Lessons learned in the early phases made the final design and specifications for series magnets more robust.

43 PARTICLE ACCELERATORS↗

Thermal noise in aqueous quadrupole micro- and nano-traps

Recent simulations and experiments with aqueous quadrupole micro-traps have confirmed a possibility for control and localization of motion of a charged particle in a water environment, also predicting a possibility of further reduction of the trap size to tens of nano-meters for trapping charged bio-molecules and DNA segments. We study the random thermal noise due to Brownian motion in water which significantly influences the trapping of particles in an aqueous environment. We derive the exact, closed-form expressions for the thermal fluctuations of position and velocity of a trapped particle and thoroughly examine the properties of the rms for the fluctuations as functions of the system parameters and time. The instantaneous signal transferring mechanism between the velocity and position fluctuations could not be achieved in the previous phase-average approaches.

Park, Jae↗

Manipulation of quantum dot emission with semiconductor metasurfaces exhibiting magnetic quadrupole resonances

Optical metasurfaces were suggested as a route for engineering advanced light sources with tailored emission properties. In particular, they provide a control over the emission directionality, which is essential for single-photon sources and LED applications. Here, we experimentally study light emission from a metasurface composed of III-V semiconductor Mie-resonant nanocylinders with integrated quantum dots (QDs). Specifically, we focus on the manipulation of the directionality of spontaneous emission from the QDs due to excitation of different magnetic quadrupole resonances in the nanocylinders. To this end, we perform both back focal plane imaging and momentum-resolved spectroscopy measurements of the emission. This allows for a comprehensive analysis of the effect of the different resonant nanocylinder modes on the emission characteristics of the metasurface. Our results show that the emission directionality can be manipulated by an interplay of the excited quadrupolar nanocylinder modes with the metasurface lattice modes and provide important insights for the design of novel smart light sources and new display concepts.

Vaskin, Aleksandr↗

Study of Conduction-Cooled Superconducting Quadrupole Magnets Combined with Dipole Correctors for the ILC Main Linac

A superconducting rf (SRF) cryomodule for International Linear Collider(ILC) Main Linac equips focus/steering magnets. The magnets are "superferric" magnets with four superconducting (SC) race track coils conductively cooled from the cryomodule LHe supply pipe. The quadrupole field gradient and dipole field are 40 T/m and 0.1 T, respectively. The magnet length and iron-pole radius are 1 m and 0.045 m, respectively. It is known that dark current is generated at SRF cavities and accelerated through the following linac string. The dark current reaches and heats the SC magnets. It is estimated that the power deposition in the magnet may reach more than a few watts and temperature of the SC coils may locally reach to critical temperature of NbTi. It is important to make the magnet not reach quench with sufficient conduction cooling. We aim to realize the SC magnet which can stably operate under such condition. We plan to develop test coils made of three types of SC materials, NbTi, Nb₃Sn, and MgB₂ and study thermal characteristics and stability . We will develop a short model magnet, based on the test coil results. Here, we will present the magnet design study and the R&D plan.

43 PARTICLE ACCELERATORS↗

Geometry Optimization for a Quadrupole Resonator at Jefferson Lab

The quadrupole resonator (QPR) is a sample characterization tool to measure the RF properties of superconducting materials using the calorime-try method at different temperatures, magnetic fields, and frequencies. Such resonators are cur-rently operating at CERN and HZB but suffer from Lorentz force detuning and modes overlap-ping, resulting in higher uncertainties in surface resistance measurement. Using the two CERN's QPR model iterations, the geometry was opti-mized via electromagnetic and mechanical simu-lations to eliminate these issues. The new QPR version was modelled for an increasing range of magnetic fields. The magnetic field is concentrat-ed at the center of the sample to reduce the un-certainty in surface resistance measurements sig-nificantly. This paper discusses the QPR geome-try optimization for the new version of QPR, which is now progressing toward fabrication.

Bira, S.↗

Nuclear Quadrupole Resonance (NQR) for Stand-off Detection of Contraband

NQR is based on an interaction between the nuclear quadrupole moment of a spin ≥ 1 nucleus (commonly 14N) and the gradient of the electric field from electrons. This causes energy level splitting similar to NMR but with no requirement of an external field. NQR is highly sensitive to chemical structure. Most explosives and drugs have NQR signals (typically in the 1-6 MHz range), thus it is an excellent candidate for detection of concealed contraband (i.e. IEDs, smuggling) but it does have issues with low SNR and long detection times.

36 MATERIALS SCIENCE↗

Septum Dump Quadrupole Measurements and Analysis

The purpose of the septum dump quadrupole (SDQ) magnet is to expand the beam size on the septum dump of the DARHT Axis 2 downstream transport. This is necessary in order to minimize the heating of the carbon beam dump and suppress desorption of ions. Initially, ions are generated through stimulated desorption and ionization of the monolayers of water vapor stuck to the beam dump surface. These ions propagate upstream at high speeds and act as an electrostatic focusing lens by reducing the beam space charge. As the beam size on the dump decreases, the dump is sufficiently heated so that a surface plasma is formed and much greater quantities of ions are generated through space charge limited emission. The interaction of these ions with the beam causes significant disruption of the beam. Because the SDQ focuses the beam in one plane and defocuses the beam in the orthogonal plane, it is critical that the beam in the focusing plane be over-focused so that the beam size in this plane is large on the beam stop. Thissets a minimum field at which the SDQ must operate. Recent magnetic measurements of the SDQ show that the actual field is about 15% lower than the design field. This note investigates the possible causes for this discrepancy and a path forward.

43 PARTICLE ACCELERATORS↗

Ultra High Performance Liquid Chromatography with Quadrupole Time-of-Flight Mass Spectrometry and Fisher Ratio Analysis for Discovery-Based Analysis

The ability to discover minute differences between samples or sample classes for ultrahigh performance liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF) can be a challenging endeavor especially when these differences are not known a priori. Indeed a typical UHPLC-QTOF analysis time of ~15 minutes can generate over 4 gigabytes of information for a single sample. Implementation of chemometrics such as Fisher ratio (F-ratio) analysis will allow the analyst to quickly and precise probe the chemical differences between different samples or sample classes. F-ratio analysis can be used to find sample or sample class distinguishing compounds reducing the 5 gigabytes of information into a simple, yet informative hit list. Moreover through combinatorial rearrangement, it is possible to determine a F-ratio threshold to separate the real and non-real hits. The F-ratio software presented herein is a semi-automated algorithm that processes the raw, exported .csv files from the SCIEX 500R QTOF in as little as 30 seconds. While further research is needed to modify and perfect the software to deal with high resolution mass spectra precise to 0.0001 Daltons, the current software, precise to 0.1 Da, is able to find significant chemical differences despite some of them being at extremely low concentrations nearing the limit of detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Septum Dump Quadrupole Magnet Design

The purpose of the septum dump quadrupole (SDQ) magnet is to expand the beam size on the septum dump of the DARHT Axis 2 downstream transport in the same manner as the S2 magnet expands the beam on the beam stop for mode 1 operations of DARHT Axis 2. This is necessary in order to minimize the heating of the carbon beam dump and suppress desorption of ions. Initially, ions are generated through stimulated desorption and ionization of the monolayers of water vapor stuck to the beam dump surface. These ions propagate upstream at high speeds and act as an electrostatic focusing lens by reducing the beam space charge. As the beam size on the dump decreases, the dump is sufficiently heated so that a surface plasma is formed and much greater quantities of ions are generated through space charge limited emission. The interaction of these ions with the beam causes significant disruption of the beam.

43 PARTICLE ACCELERATORS↗

PyEmittance: A General Python Package for Particle Beam Emittance Measurements With Adaptive Quadrupole Scans [Poster]

We present PyEmittance: a new Python package for general particle beam emittance measurements that offers adaptive quadrupole scans and is designed for robust and flexible integration with Python-based software, with online accelerators, and with simulation software. It is open source software, and can be installed via the command pip install pyemittance.

43 PARTICLE ACCELERATORS↗

Fermilab Booster Beam Emittances from Quadrupole Modes Measured BPMs

The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and requires a lot of tuning to extract out the emittances. In this paper, an improved method where multiple BPMs are used together with better mathematical analysis is described. The BPM derived emittances are then compared with those measured by the Ion Profile Monitor (IPM). Surprisingly, the BPM measured emittances behave very well and are more realistic than those measured by the IPM.

43 PARTICLE ACCELERATORS↗