Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “process tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Porosity evolution in proton irradiated microfine-grained POCO graphite

This work investigated the porosity evolution of POCO ZXF-5Q graphite that has been irradiated by 340 kW, 120 GeV protons inside NT02 target system in Fermilab's NuMI beamline. This POCO graphite has undergone direct bulk dimensional swelling at low dose irradiation and its local microstructural change is still not well-understood during this process. In this work, the (sub-) micrometre scale porosity from six locations across proton beam fluence and temperature gradients have been studied using focused ion beam-scanning electron microscopy (FIB-SEM) tomography. Here, a deep learning-based tomographic image segmentation technique has been established and implemented for porosity segmentation and quantification. It has been found that there is a decrease in the total volumetric percentage of the porosity at proton beam centre (~ 8 – 8.4 vol.%), by comparing to un-irradiated POCO (~ 12 – 13vol.%) and to beam 2σ and 5σ radii (~ 12vol.%). This decrease in porosity volume percentage was found to be caused by the reduction in pores with volumes > 0.1 μm 3 induced by material bulk dimensional swelling at proton beam centre area. The porosity reduction in relation to dimensional change and irradiation creep was discussed among with other contributing factors, and further investigations through well-controlled irradiation experiment are still needed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Imaging the crust and uppermost mantle structure of Portugal (West Iberia) with seismic ambient noise

SUMMARY We present a new high-resolution 3-D shear wave velocity (Vs) model of the crust and uppermost mantle beneath Portugal, inferred from ambient seismic noise tomography. We use broad-band seismic data from a dense temporary deployment covering the entire Portuguese mainland between 2010 and 2012 in the scope of the WILAS project. Vertical component data are processed using phase correlation and phase weighted stack to obtain empirical Green functions (EGFs) for 2016 station pairs. Further, we use a random sampling and subset stacking strategy to measure robust Rayleigh-wave group velocities in the period range 7–30 s and associated uncertainties. The tomographic inversion is performed in two steps: First, we determine group-velocity lateral variations for each period. Next, we invert them at each grid point using a new trans-dimensional inversion scheme to obtain the 3-D shear wave velocity model. The final 3-D model extends from the upper crust (5 km) down to the uppermost mantle (60 km) and has a lateral resolution of ∼50 km. In the upper and middle crusts, the Vs anomaly pattern matches the tectonic units of the Variscan Massif and Alpine basins. The transition between the Lusitanian Basin and the Ossa Morena Zone is marked by a contrast between moderate- and high-velocity anomalies, in addition to two arched earthquake lineations. Some faults, namely, the Manteigas–Vilariça–Bragança fault and the Porto–Tomar–Ferreira do Alentejo fault, have a clear signature from the upper crust down to the uppermost mantle (60 km). Our 3-D shear wave velocity model offers new insights into the continuation of the main tectonic units at depth and contributes to better understanding the seismicity of Portugal.

Silveira, Graça (ORCID:0000000221102554)↗

Optimization of Processing, Microstructure, and Hardness of an Al–Ce–Ni–Mn–Zr Alloy With Laser Additive Manufacturing

Here, this study examines the processing behavior, microstructure, surface roughness, and hardness properties of an aluminum alloy containing 8.2 Ce, 4.5 Ni, 0.5 Mn, and 0.7 Zr (wt%) fabricated using laser powder bed fusion. Sixty samples were produced across a range of laser powers, scan speeds, and hatch spacings to evaluate their effect on porosity, hardness, and microstructural features. Porosity was measured using X-ray computed tomography, while microstructure and surface roughness were characterized by scanning electron (SEM) and laser confocal microscopy. High dense and cracking-free Al–Ni–Ce alloy was successfully manufactured. Porosity showed a U-shaped dependence on energy input, increasing under both insufficient and excessive melting conditions. Hardness increased with cooling rate due to finer cellular structures and solute redistribution. A general statistical model was developed to capture the relationships between processing parameters and material response. Results identify a narrow processing window defined by laser powers between 350 and 370 W, scan speeds from 1400 to 1800 mm/s, and hatch distances between 0.14 and 0.18 mm. Within this window, porosity is minimized (below 0.01%) and hardness is maximized (up to 160 HV), demonstrating that careful control of these parameters enables dense, high strength aluminum components suitable for demanding structural applications.

Aluminum alloys↗

Water-Oil Displacement in Shale: New Insights from a Comparative Study Integrating Imbibition Tests and Multiscale Imaging

Water-oil displacement is an important process that occurs in a shale matrix after hydraulic fracturing and in water-based enhanced oil recovery. Current understanding of this displacement process is limited because of the complicated pore structure and surface properties in shale. In this work, this process and its controlling factors are investigated through a comparative study of three shale samples that have different types of pore systems and wettability. Here, an integrated method of imbibition and multiscale imaging was applied, and a modified oleic tracer that can better represent oil flow was used in imbibition testing and micro-computed tomography (CT) imaging. Scanning electron microscope (SEM) pore characterization was then performed under high magnification with guidance from the micro-CT images showing the changes caused by oil or water imbibition. New insights were obtained on the importance of both wettability and pore size effect on oil recovery and the distribution of residual oil after water-oil displacement. Connectivity of pores with different wettability is also discussed based on 3D analysis and SEM pore characterization. Collectively, these new findings improve the understanding of the complicated process of water-oil displacement and the role of influencing factors. Important implications for improved oil recovery strategy in shale are discussed for different types of reservoir rocks. The integrated imaging and imbibition technique provides a new path for further investigation of improved oil recovery in shale.

04 OIL SHALES AND TAR SANDS↗

Atomic electron tomography in three and four dimensions

Atomic electron tomography (AET) has become a powerful tool for atomic-scale structural characterization in three and four dimensions. It provides the ability to correlate structures and properties of materials at the single-atom level. With recent advances in data acquisition methods, iterative three-dimensional (3D) reconstruction algorithms, and post-processing methods, AET can now determine 3D atomic coordinates and chemical species with sub-Angstrom precision, and reveal their atomic-scale time evolution during dynamical processes. In this work, we review the recent experimental and algorithmic developments of AET and highlight several groundbreaking experiments, which include pinpointing the 3D atom positions and chemical order/disorder in technologically relevant materials and capturing how atoms rearrange during early nucleation at four-dimensional atomic resolution.

30 DIRECT ENERGY CONVERSION↗

Review of Selected Advances in Electrical Capacitance Volume Tomography for Multiphase Flow Monitoring

Electrical Capacitance Volume Tomography (ECVT) has emerged as an attractive technology for addressing instrumentation requirements in various energy-related multiphase flow systems. ECVT can monitor multiple flow conditions and reconstruct real-time 3D images from capacitance measurements using a large set of electrode plates placed around the processes column enclosing the sensed flow system. ECVT is non-intrusive and allows the measurement of changes in mutual capacitance between all possible plate pair combinations. The objective of this paper is to provide a comprehensive review of recent advances in ECVT, enabling robust monitoring of multiphase flows, especially water-containing multiphase flows.

02 PETROLEUM↗

A reliable workflow for improving nanoscale X-ray fluorescence tomographic analysis on nanoparticle-treated HeLa cells

Abstract Scanning X-ray fluorescence (XRF) tomography provides powerful characterization capabilities in evaluating elemental distribution and differentiating their inter- and intra-cellular interactions in a three-dimensional (3D) space. Scanning XRF tomography encounters practical challenges from the sample itself, where the range of rotation angles is limited by geometric constraints, involving sample substrates or nearby features either blocking or converging into the field of view. This study aims to develop a reliable and efficient workflow that can (1) expand the experimental window for nanoscale tomographic analysis of local areas of interest within a laterally extended specimen, and (2) bridge 3D analysis at micrometer and nanoscales on the same specimen. We demonstrate the workflow using a specimen of HeLa cells exposed to iron oxide core and titanium dioxide shell (Fe3O4/TiO2) nanocomposites. The workflow utilizes iterative and multiscale XRF data collection with intermediate sample processing by focused ion beam (FIB) sample preparation between measurements at different length scales. Initial assessment combined with precise sample manipulation via FIB allows direct removal of sample regions that are obstacles to both incident X-ray beam and outgoing XRF signals, which considerably improves the subsequent nanoscale tomography analysis. This multiscale analysis workflow has advanced bio-nanotechnology studies by providing deep insights into the interaction between nanocomposites and single cells at a subcellular level as well as statistical assessments from measuring a population of cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Infusible Thermoplastic Composites for Wind Turbine Blade Manufacturing: Fatigue Life of Thermoplastic Laminates under Ambient and Low-Temperature Conditions

Traditionally, thermoset resins such as polyesters (PE) and epoxies are used as the polymer matrix for construction of wind turbine blades. However, concern about their end-of-life treatment garners interest to use thermoplastics for increased recyclability. However, the high viscosity of molten thermoplastics inhibits their use in manufacturing wind turbine blades with injection or compression molding. A recently developed, infusible, reactive thermoplastic resin overcomes this technological barrier. Toward verifying that this recyclable resin is suitable for use in wind turbine blades, a dataset of R?=?0.1 and R?=?10 fatigue data for glass fiber-reinforced acrylic composites is provided and equal fatigue life to industry standard epoxy and unsaturated PE resin systems is demonstrated. Specifically, R?=?0.1 fatigue data for acrylic composites at room temperature and -30?degrees C for verification of low-temperature performance are tabulated. To elucidate failure mechanisms, in situ mechanical testing with X-ray computed tomography demonstrates that damage accumulation occurs by crack propagation along the fiber-matrix interface under cyclic loading. Infrared (IR) thermography predicts failure points in composites specimens with porosity defects introduced from nonideal manufacturing processes. Furthermore, these manufacturing defects are shown to compromise the fatigue life of the acrylic laminates by an order of magnitude.

effect of defects↗

Model studies of laser absorption computed tomography for remote air pollution measurement

Model studies of the potential of laser absorption-computed tomography are presented which demonstrate the possibility of sensitive remote atmospheric pollutant measurements, over kilometer-sized areas, with two-dimensional resolution, at modest laser source powers. An analysis of this tomographic reconstruction process as a function of measurement SNR, laser power, range, and system geometry, shows that the system is able to yield two-dimensional maps of pollutant concentrations at ranges and resolutions superior to those attainable with existing, direct-detection laser radars.

Wolfe, D. C., Jr.↗

Global Influence of Organic Aerosol Volatility on Aerosol Microphysical Processes: Composition and Number

We present MATRIX-VBS, a new aerosol scheme that simulates organic partitioning in an aerosol microphysics model, as part of the NASA GISS ModelE Earth System Model. MATRIX-VBS builds on its predecessor aerosol microphysics model MATRIX (Bauer et al., 2008, https://doi.org/10.5194/acp-8-6003-2008) and was developed in the box model framework (Gao et al., 2017, https://doi.org/10.5194/gmd-10-751-2017). The scheme features the inclusion of organic partitioning between the gas and particle phases and the photochemical aging process using the volatility-basis set (Donahue et al., 2006, https://doi.org/10.1021/es052297c). To assess the performance of the new model, we compared its mass concentration, number concentration, and activated number concentration to the original scheme MATRIX, and evaluated its mass concentrations in four seasons against data from the NASA Atmospheric Tomography Mission (ATom) aircraft campaign. Results from MATRIX-VBS show that organics are transported further away from their source, and their mass concentration increases aloft and decreases at the surface compared to those in MATRIX. The mass concentration of organics at the surface agrees well with measurements, and there are discrepancies for vertical profiles aloft. In the new scheme, the global mass load of organic aerosols increased by 50%, there is also an increased number of particles at the surface and fewer activated ones in most regions. The new scheme presents advanced and more comprehensive capability in simulating aerosol processes.

aerosol modeling↗

From Apollo to Artemis: How Processing ANGSA Core Samples 73001/2 Can Help to Prepare for Future Sample Return Missions to the Moon and Beyond.

Introduction: Apollo Sample 73001/2 is a ~71cm long double drive tube consisting of an upper part (73002) and a lower part (73001) that contains regolith collected near Lara Crater at the Apollo 17 site, Station 3. The double drive tube is believed to have penetrated a lunar landslide deposit that was transported from the slope of the South Massif into the Taurus-Littrow Valley [1]. As part of the ANGSA (Apollo Next Generation Sample Analyses) initiative, preparing a preliminary examination (PE) catalog of 73001/2 is a crucial first step for the early identification of material types such as rock fragments and potential stratigraphy within the core. Many new curation and scientific tools such as X-ray computed tomography (XCT) [3], multi-spectral imaging [4], and gas extraction manifold with piercing tool [5-7], have been applied to the ANGSA core to benefit curation strategy, PE efforts, sample allocation to the planetary science community, and ultimately help to prepare for future sample return missions like Artemis. 73001/2 Preliminary Examination and Processing: Sample 73002 was successfully opened and extruded in Nov. 2019 and fully dissected at the end of 2021. Sample 73001 (Fig. 1) was successfully extruded in March 2022 after careful planning before opening the Core Sample Vacuum Container (CSVC) that was holding the drive tube of 73001. XCT, as part of PE, was used to scan the bottom and top part of the 73001 core tube within the CSVC prior to opening it to 1) facilitate non-destructive, rapid detection of any contamination potentials due to piercing of the CSVC during gas extraction [7]; and 2) to aid in the Artemis sample tool development and provide data on the knife edge seal of the CSVC. This knowledge will help us connect the mechanics of the implemented design (i.e., XCT data) to the performance of the seal (i.e., data on the gas samples will tell us how well the seal preserved the volatile record of lunar samples). Both type of information will feed forward into Artemis tool and storage strategies for future samples. Results and Lessons learned: The XCT data of the CSVC and core tube within showed that the bottom Teflon cap was not pierced during gas extraction (Fig. 1c) and thus, the sample integrity remained guaranteed during piercing and subsequent gas extraction. However, the XCT scan of the top of the core (Fig. 1b) revealed that the drive tube was overfilled with lunar soil and the tool that keeps the soil constrained within the drive tube was not fully deployed. These preliminary data allowed us to implement the necessary steps to prevent loss of sample integrity, including any potential stratigraphy shifts during extrusion. Processing Apollo core 73001/2, creating an informative PE catalog, and applying new and refined tools and technologies for sample analyses are invaluable activities that will assist in circumventing any potential pitfalls, aid in the characterization of samples, and help in the assessment of how well any lunar material has been collected and preserved in the past. This will aid in designing future sample collections and curation procedures and help to prepare for future human exploration and sampling missions such as Artemis. References: [1] Schmitt H. (2017) Icarus 298, 2-33. [3] Zeigler et al. (2021) LPSC 52nd, #2632; [4] Sun et al. (2021), LPSC 52nd, #1789; [5] Parai et al. (2021), LPSC 52nd #2665; [6] Schild et al. (2021) LPSC 52nd #1888; [7] McDonald (2022) ESL 2022.

ANGSA↗

3D Observation of GEMS by Electron Tomography

Amorphous silicates in chondritic porous interplanetary dust particles (CP-IDPs) coming from comets are dominated by glass with embedded metal and sulfides (GEMS). GEMS grains are submicron-sized rounded objects (typically 100-500) nm in diameter) with anaometer-sized (10-50 nm) Fe-Ni metal and sulfide grains embedded in an amorphous silicate matrix. Several formation processes for GEMS grains have been proposed so far, but these models are still being debated [2-5]. Bradley et al. proposed that GEMS grains are interstellar silicate dust that survived various metamorphism or alteration processes in the protoplanetary disk and that they are amorphiation products of crystalline silicates in the interstellar medium by sputter-deposition of cosmic ray irradiation, similar to space weathering [2,4]. This consideration is based on the observation of nano-sized crystals (approximately 10 nm) called relict grains in GEMS grains and their shapes are pseudomorphs to the host GEMS grains. On the other hand, Keller and Messenger proposed that most GEMS formed in the protoplanetary disk as condensates from high temperature gas [3,5]. This model is based on the fact that most GEMS grains have solar isotopic compositions and have extremely heterogeneous and non-solar elemental compositions. Keller and Messenger (2011) also reported that amorphous silicates in GEMS grains are surrounded by sulfide grains, which formed as sulfidization of metallic iron grains located on the GEMS surface. The previous studies were performed with 2D observation by using transmission electron microscopy (TEM) or scanning TEM (STEM). In order to understand the structure of GEMS grains described above more clearly, we observed 3D structure of GEMS grains by electron tomography using a TEM/STEM (JEM-2100F, JEOL) at Kyoto University. Electron tomography gives not only 3D structures but also gives higher spatial resolution (approximately a few nm) than that in conventional 2D image, which is restricted by sample thickness ) approx. or greater than 50 nm). Three cluster IDPs (L2036AA5 cluster4, L2009L8 cluster 13 and W726A2) were used for the observations. ID W726A2 was collected without silicon oil, which is ordinary used to collect IDPs, so this sample has no possibility of contaminations caused by silicon oil or solvent to rinse it [6]. The samples were embedded in epoxy risin and sliced into ultrathin sections (50-300 nm) using an ultramicotome. The sections were observed by BF-TEM and HAADF-STEM (high angle annular dark field-scanning TEM) modes. Images were obtained by rotating the sample tilt angle over a range of +/- 65 deg in 1 deg steps. The obtained images were reconstructed to slice images. Mineral phases in the slice images were estimated by comparing with a 2D elemental map obtained by an EDS (energy dispersive X-ray spectroscopy) system equipped in the TEM/STEM. Careful examination of the slice images confirmed that iron grains are embedded in the amorphous silicate matrix of the GEMS grains, but sulfide grains were mainly present on the surface of the amorphous silicate. These results are consistent with the model that GEMS grains formed as condensates [3,5], although more data are needed to conclude the origin of GEMS grains. The present study is the first successful example adapting the electron tomography to the IDPs. This type of analysis will be important for planetary material sciences in the future.

Matsuno, Junya↗

Surface Roughness Calculations of Additively Manufactured Cylinders via X-Ray Computed Tomography

X-ray Computed Tomography (X-ray CT) is an analytical technique used in materials science to non–destructively characterize features in variety of materials like polymers, metals, composites, and explosives. It also has the capability of imaging additively manufactured, machined and assembled parts and processes. The non-destructive imaging allows for the analysis of features (voids and cracks), which give a fundamental understanding of material characteristics. Additionally, X-ray CT can obtain accurate measurements of dimensional and topographic variations as a result of different stimuli, and assess accuracy of material production. This study will focus on parts manufactured via metal additive manufacturing (AM). Although, AM produces parts faster and easier, the printing process can produce defects (pores and surface roughness) that undermine the part’s mechanical properties. The analysis of 3D printed objects has a strength in analysis in that the material has an STL file from which the item was printed, which is not available in many manufactured materials (i.e. foams) due to stochastic structures. For this study, the print accuracy of several 3D printed cylinders will be assessed via X-ray CT to determine optimal printing parameters for parts with less defects and stronger mechanical properties. This will be accomplished by having the original STL file serve as the baseline surface to compute difference in the CT rendering to calculate surface roughness for each cylinders.

36 MATERIALS SCIENCE↗

Unveiling the influence of selective-area-regrowth interfaces on local electronic properties of GaN p-n junctions for efficient power devices

Here, we report correlated nanoscale mapping of the structure, composition, and properties of regrown GaN p-n junctions to identify how etching and non-planar regrowth processes limit diode performance via the introduction of unintentional dopants and defect states. p-GaN was selectively regrown in n-GaN trenches with SiO 2 masks of variable mask-to-trench-width ratio. Dilute Al layers were periodically introduced during regrowth as markers of the growth interface. Correlated nanoscale mapping of doping, conductivity, and dopant complexes was achieved with atom probe tomography (APT), scanning spreading resistance microscopy (SSRM), and cathodoluminescence (CL) spectroscopy, respectively. The Al marker layers, detected by APT, enabled reconstruction of the faceted growth interface and correlation of the dopant concentration with position and time. The p-GaN growth rate is proportional to the mask-to-trench width ratio while the dopant incorporation rate is invariant. At trench edges, magnesium incorporation is suppressed, and oxygen incorporation enhanced, due to preferential incorporation on the semi-polar growth surface, leading to compensation and less abrupt p-n junctions; the SiO 2 mask is a source of oxygen. Residual etch damage below the regrowth interface induces n-type and p-type conductivity, creating leakage pathways. The non-uniform Mg incorporation is driven by crystal anisotropy and is thus inherent to non-planar regrowth, but can be mitigated by engineering the regrowth interface and process parameters. The unprecedented integration of spatially resolved mapping of dopants, impurities, conductivity, and carrier type is a powerful approach to discriminating distinct factors that limit the performance of regrown diodes, enabling the rational optimization of process and device design.

36 MATERIALS SCIENCE↗

LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure

A single-molecule three-dimensional (3D) structure is essential for understanding the thermal vibrations and dynamics as well as the conformational changes during the chemical reaction of macromolecules. Individual-particle electron tomography (IPET) is an approach for obtaining a snap-shot 3D structure of an individual macromolecule particle by aligning the tilt series of electron tomographic (ET) images of a targeted particle through a focused iterative 3D reconstruction method. The method can reduce the influence on the 3D reconstruction from large-scale image distortion and deformation. Due to the mechanical tilt limitation, 3D reconstruction often contains missing-wedge artifacts, presented as elongation and an anisotropic resolution. Here, we report a post-processing method to correct the missing-wedge artifact. This low-tilt tomographic reconstruction (LoTToR) method contains a model-free iteration process under a set of constraints in real and reciprocal spaces. A proof of concept is conducted by using the LoTToR on a phantom, i.e., a simulated 3D reconstruction from a low-tilt series of images, including that within a tilt range of ±15°. The method is validated by using both negative-staining (NS) and cryo-electron tomography (cryo-ET) experimental data. A significantly reduced missing-wedge artifact verifies the capability of LoTToR, suggesting a new tool to support the future study of macromolecular dynamics, fluctuation and chemical activity from the viewpoint of single-molecule 3D structure determination.

97 MATHEMATICS AND COMPUTING↗

High-Throughput Characterization Tools/Algorithms To Outline Porosity Variability in AM Samples as a Function of Processing Conditions

This report documents the development and deployment of advanced algorithms and tools that enable high-throughput characterization for metal additive manufacturing (AM), with a particular focus on process parameter optimization and material/part qualification for nuclear applications. While the method ologies presented support diverse characterization techniques, the majority of the work is centered on AI-driven algorithms for X-ray computed tomography (XCT) to accelerate defect detection and materials analysis at scale.

36 MATERIALS SCIENCE↗

Research Performed within the Non-Destructive Evaluation Team at NASA Glenn Research Center

Non-destructive testing is essential in many fields of manufacturing and research in order to perform reliable examination of potentially damaged materials and parts without destroying the inherent structure of the materials. Thus, the Non-Destructive Evaluation (NDE) Team at NASA Glenn Research Center partakes in various projects to improve materials testing equipment as well as analyze materials, material defects, and material deficiencies. Due to the array of projects within the NDE Team at this time, five research aims were supplemental to some current projects. A literature survey of "DE and testing methodologies as related to rocks was performed. Also, Mars Expedition Rover technology was assessed to understand the requirements for instrumentation in harsh space environments (e.g. temperature). Potential instrumentation and technologies were also considered and documented. The literature survey provided background and potential sources for a proposal to acquire funding for ultrasonic instrumentation on board a future Mars expedition. The laboratory uses a Santec Systems AcousticScope AS200 acoustography system. Labview code was written within the current program in order to improve the current performance of the acoustography system. A sample of Reinforced Carbon/Carbon (RCC) material from the leading edge of the space shuttle underwent various non-destructive tests (guided wave scanning, thermography, computed tomography, real time x-ray, etc.) in order to characterize its structure and examine possible defects. Guided wave scan data of a ceramic matrix composite (CMC) panel was reanalyzed utilizing image correlations and signal processing variables. Additional guided wave scans and thermography were also performed on the CMC panel. These reevaluated data and images will be used in future presentations and publications. An additional axis for the guided wave scanner was designed, constructed, and implemented. This additional axis allowed incremental spacing of the previously fixed transducers for ultrasonic velocity measurements.

Burns, Erin A.↗

Time-Domain Terahertz Computed Axial Tomography NDE System

NASA has identified the need for advanced non-destructive evaluation (NDE) methods to characterize aging and durability in aircraft materials to improve the safety of the nation's airline fleet. 3D THz tomography can play a major role in detection and characterization of flaws and degradation in aircraft materials, including Kevlar-based composites and Kevlar and Zylon fabric covers for soft-shell fan containment where aging and durability issues are critical. A prototype computed tomography (CT) time-domain (TD) THz imaging system has been used to generate 3D images of several test objects including a TUFI tile (a thermal protection system tile used on the Space Shuttle and possibly the Orion or similar capsules). This TUFI tile had simulated impact damage that was located and the depth of damage determined. The CT motion control gan try was designed and constructed, and then integrated with a T-Ray 4000 control unit and motion controller to create a complete CT TD-THz imaging system prototype. A data collection software script was developed that takes multiple z-axis slices in sequence and saves the data for batch processing. The data collection software was integrated with the ability to batch process the slice data with the CT TD-THz image reconstruction software. The time required to take a single CT slice was decreased from six minutes to approximately one minute by replacing the 320 ps, 100-Hz waveform acquisition system with an 80 ps, 1,000-Hz waveform acquisition system. The TD-THZ computed tomography system was built from pre-existing commercial off-the-shelf subsystems. A CT motion control gantry was constructed from COTS components that can handle larger samples. The motion control gantry allows inspection of sample sizes of up to approximately one cubic foot (.0.03 cubic meters). The system reduced to practice a CT-TDTHz system incorporating a COTS 80- ps/l-kHz waveform scanner. The incorporation of this scanner in the system allows acquisition of 3D slice data with better signal-to-noise using a COTS scanner rather than the gchirped h scanner. The system also reduced to practice a prototype for commercial CT systems for insulating materials where safety concerns cannot accommodate x-ray. A software script was written to automate the COTS software to collect and process TD-THz CT data.

Zimdars, David↗