Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

MassIVE MSV000094084 - Data files for manuscript - Selected ion monitoring for orbitrap-based metabolomics: Please open README-data-for-SIM-paper-20240210.doc for details.

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage. Please open README-data-for-SIM-paper-20240210.doc for details. [doi:10.25345/C5JH3DD3K] [dataset license: CC0 1.0 Universal (CC0 1.0)]

Rabinowitz, Joshua↗

Generation of realistic input parameters for simulating atmospheric point-spread functions at astronomical observatories

High-fidelity simulated astronomical images are an important tool in developing and measuring the performance of image-processing algorithms, particularly for high precision measurements of cosmic shear – correlated distortions of images of distant galaxies due to weak gravitational lensing caused by the large-scale mass distribution in the Universe. For unbiased measurements of cosmic shear, all other sources of correlated image distortions must be modeled or removed. One such source is the correlated blurring of images due to optical turbulence in the atmosphere, which dominates the point-spread function (PSF) for ground-based instruments. In this work, we leverage data from weather forecasting models to produce wind speeds and directions, and turbulence parameters, that are realistically correlated with altitude. To study the resulting correlations in the size and shape of the PSF, we generate simulated images of the PSF across a ~10 square-degree field of view – the size of the camera focal plane for the Vera C. Rubin Observatory in Chile – using weather data and historical seeing for a geographic location near the Observatory. We make quantitative predictions for two-point correlation functions (2PCF) that are used in analyses of cosmic shear. We observe a strong anisotropy in the two-dimensional 2PCF, which is expected based on observations in real images, and study the dependence of the orientation of the anisotropy on dominant wind directions near the ground and at higher altitudes.

79 ASTRONOMY AND ASTROPHYSICS↗

Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.

59 BASIC BIOLOGICAL SCIENCES↗

Fundamental study on gas monitoring in CELSS

A mass spectrometer and computer system was developed for conducting a fundamental study on gas monitoring in a Controlled Ecological Life Support System. Respiration and metabolism of the hamster and photosynthesis of the Spirulina were measured in a combination system consisting of a hamster chamber and a Spirulina cultivator. They are connected through a membrane gas exchanger. Some technical problems were examined. In the mass spectrometric gas monitoring, a simultaneous multisample measurement was developed by employing a rotating exchange valve. Long term precise measurement was obtained by employing an automatic calibration system. The membrane gas sampling probe proved to be useful for long term measurement. The cultivation rate of the Spirulina was effectively changed by controlling CO2 and light supply. The experimental results are helpful for improving the hamster-spirulina system.

Nishi, I.↗

Electromechanical Nerve Stimulator

Nerve stimulator applies and/or measures precisely controlled force and/or displacement to nerve so response of nerve measured. Consists of three major components connected in tandem: miniature probe with spherical tip; transducer; and actuator. Probe applies force to nerve, transducer measures force and sends feedback signal to control circuitry, and actuator positions force transducer and probe. Separate box houses control circuits and panel. Operator uses panel to select operating mode and parameters. Stimulator used in research to characterize behavior of nerve under various conditions of temperature, anesthesia, ventilation, and prior damage to nerve. Also used clinically to assess damage to nerve from disease or accident and to monitor response of nerve during surgery.

Tcheng, Ping↗

Precision in Assembled Discrete Lattice Space Structures for Next-Generation ISAM Applications

Robust autonomous robotic assembly of large-scale space structures has been a long-term and challenging goal to enable higher quality in-space communication and science instrumentation. For optical observatory support structures and antenna structures, the challenge is the strict dimensional precision requirements (generally RMS surface error) driven by the operational radiation wavelength. Early theoretical work in the area linked RMS surface error of a reflector support truss plate to the natural passive dynamic mode frequencies of the structure, as well as to the error distribution in dimensions of constituent structural elements. Prior robotic truss assembly demonstrations focused on designing ultra-high precision structural elements, joints, and robotic actuators. Recently, an alternative space structure assembly strategy based on a programmable matter approach (NASA ARMADAS) was demonstrated. This approach uses lattice building blocks (voxels) that are reversibly, mechanically joined into a bulk lattice structure by robots that locomote in and on the structure itself. Such a system can achieve high-level autonomy with low computation, robustly assemble utilizing inexpensive and imprecise robots, and efficiently build structures several orders of magnitude larger than the assembly robots. However, for instrumentation support structure applications, the resulting precision of these building block-based lattice structures is not well studied. Since they are demonstrated with many more assembly units than prior art trusses, it is unclear whether the same precision design approaches apply. In this work, we study in simulation the effects of voxel geometry, error in distribution, assembly resolution (module size), and assembly geometry on the error of both beam and plate lattice structures. While average RMS error of a plate increases with plate size, increasing plate thickness quickly collapses RMS error towards a limit that is on the order of the error of the constituent parts. We validate our models against previously published precision measurements of built systems. Results from this study will guide manufacturing precision requirements, as well as designs, for future robotically assembled structural applications and establish feasibility for different applications.

Christine E Gregg↗

MeV Scale Physics in MicroBooNE

This thesis presents the reconstruction and measurement of low-energy electromagnetic activity with beam neutrino interactions within the MicroBooNE Liquid Argon Time Projection Chamber (LArTPC). LArTPCs have proven to be excellent detectors to measure neutrino interaction cross sections and are being used to perform precision measurements of neutrino oscillation parameters. The work presented in this thesis has demonstrated unprecedentedly low, sub-MeV energy thresholds that have increased sensitivity of LArTPCs to detect neutrino interactions from core collapse supernovae and Muon Decay at Rest (µDAR). In addition, such low thresholds have also increased measurement sensitivity for interactions from Beyond the Standard Model (BSM) candidates such as millicharged particles and nuclear and electron recoils from dark matter candidate particles. On the reconstruction side, this work has established an energy resolution of 6.3% for electromagnetic activity i the 0-5 MeV energy range within the MicroBooNE LArTPC. Additionally this work presents the quantitative analysis of the low-energy activity emanating from G-10 support ribs in MicroBooNE and discusses how such activity could be a problematic source of background for low-energy physics analyses in future neutrino detectors such as the Deep Underground Neutrino Experiment (DUNE).

Bhat, Avinay↗

Lidar Measurements of Atmospheric CO2 From Regional to Global Scales

Atmospheric CO2 is a critical forcing for the Earth's climate and the knowledge on its distributions and variations influences predictions of the Earth's future climate. Large uncertainties in the predictions persist due to limited observations. This study uses the airborne Intensity-Modulated Continuous-Wave (IMCW) lidar developed at NASA Langley Research Center to measure regional atmospheric CO2 spatio-temporal variations. Further lidar development and demonstration will provide the capability of global atmospheric CO2 estimations from space, which will significantly advances our knowledge on atmospheric CO2 and reduce the uncertainties in the predictions of future climate. In this presentation, atmospheric CO2 column measurements from airborne flight campaigns and lidar system simulations for space missions will be discussed. A measurement precision of approx.0.3 ppmv for a 10-s average over desert and vegetated surfaces has been achieved. Data analysis also shows that airborne lidar CO2 column measurements over these surfaces agree well with in-situ measurements. Even when thin cirrus clouds present, consistent CO2 column measurements between clear and thin cirrus cloudy skies are obtained. Airborne flight campaigns have demonstrated that precise atmospheric column CO2 values can be measured from current IM-CW lidar systems, which will lead to use this airborne technique in monitoring CO2 sinks and sources in regional and continental scales as proposed by the NASA Atmospheric Carbon and Transport â€" America project. Furthermore, analyses of space CO2 measurements shows that applying the current IM-CW lidar technology and approach to space, the CO2 science goals of space missions will be achieved, and uncertainties in CO2 distributions and variations will be reduced.

Lin, Bing↗

Measurement of the branching fraction of the decay J / ψ → p p ¯ η

A high-precision measurement of the branching fraction of the decay J / ψ → p p ¯ η is performed using ( 10 087 ± 44 ) × 10 6 J / ψ events recorded by the BESIII detector at the BEPCII storage ring. The branching fractions of the two decays J / ψ → p p ¯ η ( η → γ γ ) and J / ψ → p p ¯ η ( η → π + π − π 0 ) are measured individually to be B ( J / ψ → p p ¯ η ( η → γ γ ) ) = ( 1.480 ± 0.001 ± 0.024 ) × 10 − 3 and B ( J / ψ → p p ¯ η ( η → π + π − π 0 ) ) = ( 1.557 ± 0.003 ± 0.038 ) × 10 − 3 , where the first uncertainties are statistical and the second systematic. Both results are compatible within their uncorrelated systematic uncertainties. The combined result is B ( J / ψ → p p ¯ η ) = ( 1.495 ± 0.001 ± 0.023 ) × 10 − 3 , where the first uncertainty is the combined statistical uncertainty and the second one the combined systematic uncertainty of both analyses, incorporating correlations between them. In addition, the p p ¯ threshold region is investigated for a potential threshold enhancement, and no evidence for one is observed. Published by the American Physical Society 2024

Ablikim, M.↗

Investigation of Space Interferometer Control Using Imaging Sensor Output Feedback

Numerous space interferometry missions are planned for the next decade to verify different enabling technologies towards very-long-baseline interferometry to achieve high-resolution imaging and high-precision measurements. These objectives will require coordinated formations of spacecraft separately carrying optical elements comprising the interferometer. High-precision sensing and control of the spacecraft and the interferometer-component payloads are necessary to deliver sub-wavelength accuracy to achieve the scientific objectives. For these missions, the primary scientific product of interferometer measurements may be the only source of data available at the precision required to maintain the spacecraft and interferometer-component formation. A concept is studied for detecting the interferometer's optical configuration errors based on information extracted from the interferometer sensor output. It enables precision control of the optical components, and, in cases of space interferometers requiring formation flight of spacecraft that comprise the elements of a distributed instrument, it enables the control of the formation flying vehicles because independent navigation or ranging sensors cannot deliver the high-precision metrology over the entire required geometry. Since the concept can act on the quality of the interferometer output directly, it can detect errors outside the capability of traditional metrology instruments, and provide the means needed to augment the traditional instrumentation to enable enhanced performance. Specific analyses performed in this study include the application of signal-processing and image-processing techniques to solve the problems of interferometer aperture baseline control, interferometer pointing, and orientation of multiple interferometer aperture pairs.

Cheng, Victore H. L.↗

Investigation of Space Interferometer Control Using Imaging Sensor Output Feedback

Numerous space interferometry missions are planned for the next decade to verify different enabling technologies towards very-long-baseline interferometry to achieve high-resolution imaging and high-precision measurements. These objectives will require coordinated formations of spacecraft separately carrying optical elements comprising the interferometer. High-precision sensing and control of the spacecraft and the interferometer-component payloads are necessary to deliver sub-wavelength accuracy to achieve the scientific objectives. For these missions, the primary scientific product of interferometer measurements may be the only source of data available at the precision required to maintain the spacecraft and interferometer-component formation. A concept is studied for detecting the interferometer's optical configuration errors based on information extracted from the interferometer sensor output. It enables precision control of the optical components, and, in cases of space interferometers requiring formation flight of spacecraft that comprise the elements of a distributed instrument, it enables the control of the formation-flying vehicles because independent navigation or ranging sensors cannot deliver the high-precision metrology over the entire required geometry. Since the concept can act on the quality of the interferometer output directly, it can detect errors outside the capability of traditional metrology instruments, and provide the means needed to augment the traditional instrumentation to enable enhanced performance. Specific analyses performed in this study include the application of signal-processing and image-processing techniques to solve the problems of interferometer aperture baseline control, interferometer pointing, and orientation of multiple interferometer aperture pairs.

Leitner, Jesse A.↗

A Real-time View of Orbital Evolution in HM Cancri

HM Cancri is a double-degenerate binary with the shortest orbital period presently known. The 5.36 minute period is seen as a large amplitude, soft X-ray modulation, likely resulting from a hot-spot produced by direct impact accretion. With such a7short orbital period it is expected to have a gravitational wave luminosity comparable8to or larger than that in the X-ray, and its orbital frequency is known to be increasing9at a rate consistent with the expected loss of angular momentum due to gravitational radiation. We use recent Neutron Star Interior Composition Explorer(NICER) observations to extend its long-term X-ray timing baseline to almost 20 yr. Phase coherent timing of these new data combined with existing Chandra data demonstrates conclusively that the rate of orbital frequency increase is slowing, and we measure a non-zero f0=8.95 ± 1.4 x 1027 Hz s2, to our knowledge the first such measurement of its kind for any compact astrophysical binary. With the simultaneous high precision measurement of f0= 3.557 ± 0.005 x 1016 Hz s1, we estimate that the system17will reach its maximum orbital frequency of fmax 3.1172091 mHz in 1,260 ± 200 yr, indicating that the system is close to its epoch of maximum orbital frequency. Assuming mass transfer is conservative, the measurement of f<0 implies that the20accretion rate from the donor is growing, with 5.4 x 1010<M2<4.0 x 1010 M⊙yr2. Further quantitative comparisons with theoretical models should enable more precise inferences regarding its current evolutionary state.

White dwarfs↗

Spectroscopic study and lifetime measurement of the 6d7p 3 F 2 o state of radium

We report a method for the precision measurement of the oscillator strengths and the branching fractions of the decay channels of the 6d7p 3 F 2 o state in 226 Ra. Here, this method exploits a set of metastable states present in Ra, allowing a measurement of the oscillator strengths that does not require knowledge of the number of atoms in the atomic beam. We measure the oscillator strengths and the branching fractions for decays from the 6d7p 3 F 2 o state to the 7s6d 3 D 1 , 7s6d 3 D 2 , and 7s6d 1 D 2 states and constrain the branching fraction to the 7s6d 3 D 3 state to be less than 0.4% (68% confidence limit). The lifetime of the 3 F 2 o state is determined to be 15 ± 4 ns.

74 ATOMIC AND MOLECULAR PHYSICS↗

Gauges for Highly Precise Metrology of a Compound Mirror

Three optical gauges have been developed for guiding the assembly and measuring precisely the reflecting surfaces of a compound mirror that comprises a corner-cube retroreflector glued in a hole on a flat mirror. In the specific application for which the gauges were developed, the compound mirror is part of a siderostat in a stellar interferometer. The flat-mirror portion of the compound mirror is the siderostat mirror; the retroreflector portion of the compound mirror is to be used, during operation of the interferometer, to monitor the location of the siderostat mirror surface relative to other optical surfaces of the interferometer. Nominally, the optical corner of the retroreflector should lie precisely on the siderostat mirror surface, but this precision cannot be achieved in fabrication: in practice, there remains some distance between the optical corner and the siderostat mirror surface. For proper operation of the interferometer, it is required to make this distance as small as possible and to know this distance within 1 nm. The three gauges make it possible to satisfy these requirements.

Gursel, Yekta↗

Toward quantifying capacity losses due to solid electrolyte interphase evolution in silicon thin film batteries

To understand the origins of failure and limited cycle life in lithium-ion batteries (LIBs), it is imperative to quantitatively link capacity-fading mechanisms to electrochemical and chemical processes. This is extremely challenging in real systems where capacity is lost during each cycle to both active material loss and solid electrolyte interphase (SEI) evolution, two indistinguishable contributions in traditional electrochemical measurements. Here, we have used a model system in combination with (1) precision measurements of the overall Coulombic efficiency via electrochemical experiments and (2) x-ray reflectivity measurements of the active material losses. The model system consisted of a 515 Å thick amorphous silicon (a-Si) thin film on silicon carbide in half-cell geometry using a carbonate electrolyte with LiPF6 salt. This approach allowed us to quantify the capacity lost during each cycle due to SEI evolution. Combined with electrochemical analysis, we identify SEI growth as the major contribution to capacity fading. Specifically, the continued SEI growth results in increasing overpotentials due to increased SEI resistance, and this leads to lower extent of lithiation when the cutoff voltage is reached during lithiation. Our results suggest that SEI grows more with increased time spent at low voltages where electrolyte decomposition is favored. Finally, we extracted a proportionality constant for SEI growth following a parabolic growth law. Our methodology allows for the quantitative determination of lithium-ion loss mechanisms in LIBs by separately tracking lithium ions within the active materials and the SEI and offers a powerful method of quantitatively understanding LIB loss mechanisms.

25 ENERGY STORAGE↗

Characterizing gravitational wave detector networks: from A # to cosmic explorer

Gravitational-wave observations by the laser interferometer gravitational-wave observatory (LIGO) and Virgo have provided us a new tool to explore the Universe on all scales from nuclear physics to the cosmos and have the massive potential to further impact fundamental physics, astrophysics, and cosmology for decades to come. In this paper we have studied the science capabilities of a network of LIGO detectors when they reach their best possible sensitivity, called A # , given the infrastructure in which they exist and a new generation of observatories that are factor of 10 to 100 times more sensitive (depending on the frequency), in particular a pair of L-shaped cosmic explorer (CE) observatories (one 40 km and one 20 km arm length) in the US and the triangular Einstein telescope with 10 km arms in Europe. We use a set of science metrics derived from the top priorities of several funding agencies to characterize the science capabilities of different networks. The presence of one or two A # observatories in a network containing two or one next generation observatories, respectively, will provide good localization capabilities for facilitating multimessenger astronomy (MMA) and precision measurement of the Hubble parameter. Two CE observatories are indispensable for achieving precise localization of binary neutron star events, facilitating detection of electromagnetic counterparts and transforming MMA. Their combined operation is even more important in the detection and localization of high-redshift sources, such as binary neutron stars, beyond the star-formation peak, and primordial black hole mergers, which may occur roughly 100 million years after the Big Bang. The addition of the Einstein Telescope to a network of two CE observatories is critical for accomplishing all the identified science metrics including the nuclear equation of state, cosmological parameters, the growth of black holes through cosmic history, but also make new discoveries such as the presence of dark matter within or around neutron stars and black holes, continuous gravitational waves from rotating neutron stars, transient signals from supernovae, and the production of stellar-mass black holes in the early Universe. For most metrics the triple network of next generation terrestrial observatories are a factor 100 better than what can be accomplished by a network of three A # observatories.

Einstein telescope↗