Measurement Capabilities of Single-Pulse Planar Doppler Velocimetry

Preliminary investigations are described of a method that is capable of measuring instantaneous, 3-D, velocity vectors everywhere in a light sheet generated by a pulsed laser. The technique, here called Planar Doppler Velocimetry (PDV), is a variation of a new concept for velocity measurements that was called Doppler Global Velocimetry (DGV) in its original disclosure. The concept relies on the use of a narrowband laser and measurements of the Doppler shift of scattered light from particles moving with a flow. The Doppler shift is recorded as a variation in transmission through a sharp-edged spectral filter provided by iodine vapor in a cell. Entire fields of velocity can be determined by using a solid-state camera to record the intensity variations throughout the field of view. However, the implementation of DGV has been centered principally on the use of high power, continuous-wave, ion lasers and measurement times that are determined by the 30-ms framing times of standard video cameras. Hence, they provide velocity fields that are averaged in time at least over that period. On the other hand, the PDV concept described in this presentation incorporates a high energy, repetitively pulsed, Nd-YAG laser that is injection-seeded to make it narrowband and then frequency-doubled to provide light at frequencies absorbed by the iodine vapor. The duration of each pulse is less than 10 nanoseconds. When used in combination with nonstandard, scientific quality, solid state cameras, a sequence of images can be obtained that provides instantaneous velocity vectors everywhere in the field of view. The investigations described in this paper include an accurate characterization of the iodine cell spectral behavior and its influence on the PDV measurements, a derivation of the PDV signal analysis requirements, and the unique aspects of the pulsed laser behavior related to this application. In addition, PDV measurements are to be demonstrated using data from a rotating wheel target and from the flow of a subsonic jet. Initially, single optical fiber light collection and photomultiplier detectors will be substituted for solid state cameras. Those results will allow the determination of the fundamental limitations of the PDV technique without the complications of image acquisition and processing. They will then be used to provide an analysis of the measurement capabilities of PDV both in small aerodynamic research wind tunnels and in large wind tunnels designed for production airframe and propulsion testing. Future plans include the implementation of solid state cameras and the development of the required image acquisition and processing software. Eventually, the PDV technique will be applied to an aerodynamic research program related to transonic wing flutter.

McKenzie, Robert L.↗

A Concept for the Inclusion of Analytical and Computational Capability in Existing Systems for Measurement of Neutron Flux

For approximately two decades, efforts have been sponsored by NASA's Marshall Space Flight Center to make possible high-speed, automated classification and quantification of constituent materials in various harsh environments. MSFC, along with the Air Force/Arnold Engineering Development Center, has led the work, developing and implementing systems that employ principles of emission and absorption spectroscopy to monitor molecular and atomic particulates in gas plasma of rocket engine flow fields. One such system identifies species and quantifies mass loss rates in H2/O2 rocket plumes. Other gases have been examined and the physics of their detection under numerous conditions were made a part of the knowledge base for the MSFC/USAF team. Additionally, efforts are being advanced to hardware encode components of the data analysis tools in order to address real-time operational requirements for health monitoring and management. NASA has a significant investment in these systems, warranting a spiral approach that meshes current tools and experience with technological advancements. This paper addresses current systems - the Optical Plume Anomaly Detector (OPAD) and the Engine Diagnostic Filtering System (EDIFIS) - and discusses what is considered a natural progression: a concept for migrating them towards detection of high energy particles, including neutrons and gamma rays. The proposal outlines system development to date, basic concepts for future advancements, and recommendations for accomplishing them.

Patrick, Clinton↗

In situ measurements of light extinction of stratospheric aerosols

The extinction coefficient of ambient aerosol particles was measured using a multiple transverse cell (White Cell) with an effective path length of 100 m. Measurements were performed at seven fixed wavelengths in the visible region using a white light source and an interference filter set with 2 nm bandwidth and center wavelengths of 405.5, 450, 500, 550, 600, 650, and 692.5 nm. The total air flow in the system was 16.7 1/min; the volume of the chamber is close to 10 liters. It takes about one minute to fill the chamber with particles homogeneously, but it needs up to five minutes to get the chamber particle-free. Before measuring the aerosol, the transmission of the particle-free air is determined; then the aerosol passes through the chamber for a period of ten minutes; after this the transmission of particle-free ambient air is measured again for eight minutes. All times are subject to change. At present the measurements are done with a frequency of 1 Hz, but an increase of up to 30 Hz is possible. The lower detection limit of the used White Cell is 3.4 by 10(exp -06) per m. This is sufficient for measuring the extinction coefficient during most tropospheric and some stratospheric conditions. It will be necessary to increase the sensitivity by a factor of ten when measurements under the clearest stratospheric conditions take place.

Metzig, Gunthard↗

Collision Tracking in OpenMC: Methods and Applications in Neutron Noise, Neutron Imaging, Time-of-Flight, and Multiplicity Counting

We present the development and application of a collision tracking feature within the OpenMC Monte Carlo particle transport code, designed for diverse applications such as neutron spectroscopy, scatter camera system, neutron noise, and multiplicity counting simulations. This feature enables the tracking of individual particle collisions, with potential applications in nuclear nonproliferation, reactor physics, and nuclear security. Additionally, the feature holds potential for the calibration of neutron detectors, specifically in converting light output into energy deposited within the detectors. The implementation consists of a set of filters—such as reaction type, energy, cell, and material—that constrain the set of collisions that are tracked, extensions to the Python API to enable simple input specification, and support for writing either OpenMC’s native HDF5-based format or the Monte Carlo particle list format. This feature was added to the official OpenMC release in version 0.15.3. In this work, the feature will be applied to showcase scenarios such as time-of-flight simulations, scatter-camera imaging for neutron source localization, neutron-noise analysis to extract integral kinetic parameters such as the prompt decay constant α, and multiplicity counting to estimate the mass of special nuclear materials. Ultimately, this feature aims to expand the application scope of open-source Monte Carlo particle transport codes such as OpenMC.

Monte Carlo code↗

Smart Pixel Sensors for the HL-LHC

Large-scale particle physics experiments produce tens of terabytes of data every second. Innovative methods to manage the data rate at the HL-LHC, which expects to operate at 10x the luminosity of what the LHC was initially designed for, are needed. AI-on the chip provides a way to intelligently filter out low momentum clusters in the pixel detector. This will open up an opportunity to use the pixel detector for the first time in the CMS Level-1 trigger, and lead to increased sensitivity to new physics measurements and searches. We have taped out our first chip, which incorporates a $p_T$ filtering algorithm on an ASIC chip. Our initial $p_T$ filtering algorithm considers clusters that are tracked by CMS. We will report on ongoing studies seeking to enhance the performance of our filter by utilizing unsupervised learning on untracked clusters, thus increasing background rejection.

43 PARTICLE ACCELERATORS↗

High Resolution Data Analysis: Plans and Prospects [Book Chapter]

Herein, a report on the progress on the high resolution data analysis of the ADMX experimental results is presented. In this paper, tools are developed and tested on a blind injection mimicking a Maxwellian like signal in the frequency domain. This blind injection will be used as a test bed which can be later implemented on all the high resolution data. The high resolution data is stored in the Fermilab server. In this analysis a PostgreSQL query was made to ensure the blind injection is in the middle of the frequency spectrum and 19 such files were found. The time series data is read using a c++ program. An apodization function is applied on the time series data and zero filled to reduce the frequency spacing in order to achieve a better interpolation. A FFTW header is used to compute the Fourier transform of the time series data. A Savitzky–Golay filter is applied on the unnormalized power which then can be used to remove the spectral shape. Each frequency spectrum has a bandwidth of 50 kHz.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ferrographic analysis of wear debris from full-scale bearing fatigue tests

The Ferrograph was used to determine the types and quantities of wear particles generated during full scale bearing fatigue tests. Deep-groove ball bearings made from steel were used. A tetraester lubricant was used in a recirculating lubricant system containing a 49 micrometers absolute filter. Test conditions include a maximum Hertz stress of 2.4 GPa, a shaft speed of 15,000 rpm, and a lubricant supply temperature of 74 C (165 F). Four fatigue failures were detected by accelerometers in this test set. In general, the Ferrograph was more sensitive (up to 23 hr) in detecting spall initiation than either accelerometers or the normal spectrographic oil analysis. Four particle types were observed: normal rubbing weather particles, spheres, nonferrous particles, and severe wear (spall) fragments.

Jones, W. R., Jr.↗

Water system virus detection

A monitoring system developed to test the capability of a water recovery system to reject the passage of viruses into the recovered water is described. A nonpathogenic marker virus, bacteriophage F2, is fed into the process stream before the recovery unit and the reclaimed water is assayed for its presence. Detection of the marker virus consists of two major components, concentration and isolation of the marker virus, and detection of the marker virus. The concentration system involves adsorption of virus to cellulose acetate filters in the presence of trivalent cations and low pH with subsequent desorption of the virus using volumes of high pH buffer. The detection of the virus is performed by a passive immune agglutination test utilizing specially prepared polystyrene particles. An engineering preliminary design was performed as a parallel effort to the laboratory development of the marker virus test system. Engineering schematics and drawings of a fully functional laboratory prototype capable of zero-G operation are presented. The instrument consists of reagent pump/metering system, reagent storage containers, a filter concentrator, an incubation/detector system, and an electronic readout and control system.

Fraser, A. S.↗

The phase-2 particle x-ray temporal diagnostic for simultaneous measurement of multiple x-ray and nuclear emission histories from OMEGA implosions (invited)

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as T e is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (~15 ps) scintillator-channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons (DTn) from OMEGA Cryo-DT implosions. High quality data have been collected from warm implosions at OMEGA. These data have been used to infer spatially integrated T e (t) with <10% uncertainty at peak emission. Nuclear and x-ray emission histories are measured with 10 ps relative timing uncertainty for x rays and DTn and 12 ps for x rays and deuterium- 3 He protons (D 3 Hep). A future upgrade to the system will enable spatially integrated T e (t) with 40 ps time-resolution from cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigating spatial variability of aerosol, cloud condensation nuclei, and ice nucleating particles in mountainous terrain

The ASR-supported Surface Atmosphere Integrated field Laboratory (SAIL) in the East River Watershed (ERW) of the Upper Colorado River Basin in southwestern Colorado ran from fall 2021 to spring 2023. Two monitoring sites were deployed in the East River Watershed as part of SAIL. The two sites were the Aerosol Observation System (AOS) located on Crested Butte Ski Mountain, and the ARM Mobile Facility (AMF-2), located at the Rocky Mountain Biological Laboratory in Gothic, Colorado. To gain a more comprehensive understanding of aerosols in complex, mountainous terrain, Handix Scientific deployed SAIL-Net, a distributed network of six measurement nodes spanning the domain of the SAIL research area from October 2021 to July 2023. Each node measured aerosol particles between 140 nm and 3.4 μm in diameter using a small particle counter (POPS, (Gao et al., 2016)), CNN using a miniature CCN counter (CloudPuck), and INP using the Time-Resolved Aerosol Filter Sampler (TRAPS, Creamean et al. (2018)). Our approach was similar to other studies that aimed to better characterize and understand aerosols and gas-phase pollutants using networks of lower-cost sensors (Caubel et al., 2019; Kelly et al., 2021; Asher et al., 2022). Such studies have identified neighborhood-level variations in pollutant concentrations (Schneider et al., 2017; Popoola et al., 2018; Caubel et al., 2019). Small-scale variations such as this are poorly represented in models and poorly measured by a single monitoring system (Caubel et al., 2019). Previous work has shown the representation error (the ability of measurements to represent a larger area) increases with complex orography, leading to decreases in model accuracy (Schutgens et al., 2017). The overall goal of SAIL-Net was to improve our understanding of the variability of aerosol in ERW, thus increasing our knowledge of aerosol-cloud interactions in this region and informing the usefulness of distributed networks of measurements for future studies.

54 ENVIRONMENTAL SCIENCES↗

CERES Clouds and Radiative Swath (CRS) data in HDF. (CER_CRS_Terra-FM1-MODIS_Edition2A)

The Clouds and Radiative Swath (CRS) product contains one hour of instantaneous Clouds and the Earth's Radiant Energy System (CERES) data for a single scanner instrument. The CRS contains all of the CERES SSF product data. For each CERES footprint on the SSF the CRS also contains vertical flux profiles evaluated at four levels in the atmosphere: the surface, 500-, 70-, and 1-hPa. The CRS fluxes and cloud parameters are adjusted for consistency with a radiative transfer model and adjusted fluxes are evaluated at the four atmospheric levels for both clear-sky and total-sky. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2001-12-31] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Temporal_Resolution=1 hour; Temporal_Resolution_Range=Hourly - < Daily].

SHORTWAVE FILTERED RADIANCE↗

CERES Clouds and Radiative Swath (CRS) data in HDF. (CER_CRS_Terra-FM2-MODIS_Edition2B)

The Clouds and Radiative Swath (CRS) product contains one hour of instantaneous Clouds and the Earth's Radiant Energy System (CERES) data for a single scanner instrument. The CRS contains all of the CERES SSF product data. For each CERES footprint on the SSF the CRS also contains vertical flux profiles evaluated at four levels in the atmosphere: the surface, 500-, 70-, and 1-hPa. The CRS fluxes and cloud parameters are adjusted for consistency with a radiative transfer model and adjusted fluxes are evaluated at the four atmospheric levels for both clear-sky and total-sky. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2001-10-31] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Temporal_Resolution=1 hour; Temporal_Resolution_Range=Hourly - < Daily].

SHORTWAVE UNFILTERED RADIANCE↗

Lessons Learned from Particulate Characterization Laboratory Anomalies

The White Sands Test Facility chemistry laboratory provides quality control for cleanroom operations including cleanliness verification of aerospace hardware by particulate counts and non-volatile residue determinations, particulate counts for liquid hypergolic propellants, gaseous helium and nitrogen propellant pressurizing agents used for ground support equipment and flight test article valve actuation, gaseous oxygen primarily used for component testing, and deionized water for refurbished propellant hardware flushing. Cleanliness verification includes particulate counts and non-volatile residue determinations to industry standard, NASA, and program specifications and levels. Particulate counts are typically to customer-specified specifications and levels including JPR 5322.1H (2016) Levels 50 and 100, Orion (MPCV 70156. Revision H (2018)) Level 100, RPTSTD-8070-0001 Revision 3 (2022), and IEST-STD-CC1246E (2013) Levels 50 and 100. The laboratory issues high pressure filter holders containing membrane filters to test operations personnel, who collect samples by flowing the required volumes of fluid through the filter holder, and the filter holder is returned to the lab for counting. A passing particulate count is required before testing may proceed. Rapid data reduction and issuing of reports indicating a pass or fail of the particulate specification are required. Corrective action and resampling invariably occurs if a sample fails. Consequently, the laboratory must maintain the highest degree of reliability to facilitate quality data used to decide if testing may proceed. Experience and continual improvements have enabled reliability. However, anomalies attributed to lab processes and hardware including filter holders, membranes, and Petri dishes have been encountered. This paper presents a summary of problems, solutions, successes, and lessons learned from particle counting experience for over 35 years.

Lessons Learned↗

Simultaneous imaging of two-phase velocities in particle-laden flows by two-color optical phase discrimination

In this Letter, we present a particle image/tracking velocimetry (PIV/PTV) technique for simultaneous velocity measurement of both fluid and particle phases, adopting newly developed optical phase discrimination methods and novel optical particles. Spherical acrylic (PMMA) particles of diameter ∼ <#comment/> O ( 100 µ <#comment/> m ) were used as the particle phase, while fine B A M : E u 2 + phosphors of diameter ∼ <#comment/> O ( 1 µ <#comment/> m ) were used as the fluid tracer. Under Nd:YAG 355 nm laser excitation, both the laser-induced fluorescence (LIF) from PMMA and laser-induced phosphorescence (LIP) from B A M : E u 2 + provided sufficiently strong signals for PIV imaging with two non-intensified cameras and were clearly separable for phase discrimination using spectral filters and temporal profiles. The advantages of the PIV/PTV method include the relatively low cost of B A M : E u 2 + phosphors, high sphericity and narrow size distribution of PMMA particles with LIF emission, and direct optical discrimination eliminating artifacts, while requiring much less computational capacity for PIV/PTV processing of complex particle-laden flows.

Bi, Xiaopeng (ORCID:0000000190847325)↗

Surface Plasmon Resonance Evaluation of Colloidal Metal Aerogel Filters

We have fabricated aerogels containing gold, silver, and platinum nanoparticles for gas catalysis applications. By applying the concept of an average or effective dielectric constant to the heterogeneous interlayer surrounding each particle, we extend the technique of immersion spectroscopy to porous or heterogeneous media. Specifically, we apply the predominant effective medium theories for the determination of the average fractional composition of each component in this inhomogeneous layer. Hence, the surface area of metal available for catalytic gas reaction is determined. The technique is satisfactory for statistically random metal particle distributions but needs further modification for aggregated or surfactant modified systems. Additionally, the kinetics suggest that collective particle interactions in coagulated clusters are perturbed during silica gelation resulting in a change in the aggregate geometry.

Smith, David D.↗

Final Report on Aerosol Pretreatment Technology Performance and Benchmarking

Solvent-based post-combustion CO 2 capture (PCC) technology remains one of the leading methods to combat global CO 2 emissions produced from large-scale coal-fired power production. Advanced solventbased PCC technology has made significant improvements in design and performance that reduce capital and operating costs to enable its commercial use. Key to low cost, manageable logistics, and environmentally safe operation of solvent-based PCC technology are minimal solvent losses from the process through the treated gas stream exiting PCC plant absorbers. High flue gas aerosol particle concentrations (>10 5 particles/cm 3 ) for particles in the range of 70-200 nm have been shown to cause significant amine solvent losses for solvent-based PCC processes through several mechanisms including absorption of solvent and water into growing aerosol particles. Flue gas aerosol pretreatment technology is the only realistic and economically attractive method to reduce very high aerosol particle concentrations (>10 7 particles/cm 3 ) to enable solvent-based PCC for existing power plants lacking sufficient particle removal systems, such as baghouses. The overall goal of this project was to design, construct, independently test, and evaluate three flue gas aerosol pretreatment technologies identified to significantly reduce high aerosol particle concentrations (>10 7 particles/cm 3 ) in the 70-200 nm particle size range: (1) a novel, high-velocity water injection spray concept developed by RWE and tested by Linde, (2) an innovative electrostatic precipitator (ESP) device with optimized operating conditions developed by Washington University in St. Louis (WUSTL), and (3) a non-regenerative sorbent-based filter technology developed by InnoSepra for SO x and NO x removal from coal-fired power plant flue gas. Each technology has been validated with tests on 500-1000 scfm of actual coal-fired flue gas and evaluated in terms of particle removal efficiency (%), cost competitiveness, and environmental impact. Aerosol measurements were performed upstream and downstream of each aerosol reduction unit during independent testing of each technology using advanced instrumentation and analytical methods provided by WUSTL. To perform aerosol measurements, isokinetic probes were inserted into flanged pipes attached to the flue gas piping, and a small suction pump was used to sample gas containing aerosol particles. Aerosol particle number concentrations (# particles/cm 3 ) and size distributions were then measured using a scanning mobility particle sizer (SMPS, TSI Inc.) for very fine particles (<1,000 nm) and a particle counter manufactured by GRIMM for particles larger than 1,000 nm. This report summarizes the aerosol removal performance results from pilot scale testing of each technology. Performance results have been benchmarked against pre-defined targets and other flue gas aerosol pretreatment technologies with documented performance. Linde Gas North America LLC has been the prime contractor to DOE responsible for overall project management and provided the design for the high-velocity water spray-based aerosol removal technology based on a design concept developed by the German utility company RWE.

20 FOSSIL-FUELED POWER PLANTS↗

A Catalog of Galaxy Clusters Observed by XMM-Newton

Images and the radial profiles of the temperature, abundance, and brightness for 70 clusters of galaxies observed by XMM-Newton are presented along with a detailed discussion of the data reduction and analysis methods, including background modeling, which were used in the processing. Proper consideration of the various background components is vital to extend the reliable determination of cluster parameters to the largest possible cluster radii. The various components of the background including the quiescent particle background, cosmic diffuse emission, soft proton contamination, and solar wind charge exchange emission are discussed along with suggested means of their identification, filtering, and/or their modeling and subtraction. Every component is spectrally variable, sometimes significantly so, and all components except the cosmic background are temporally variable as well. The distributions of the events over the FOV vary between the components, and some distributions vary with energy. The scientific results from observations of low surface brightness objects and the diffuse background itself can be strongly affected by these background components and therefore great care should be taken in their consideration.

Snowden, S. L.↗