Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “outdoor testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Water and Air Measures That Make 'PureSense'

Each day, we read about mounting global concerns regarding the ability to sustain supplies of clean water and to reduce air contamination. With water and air serving as life s most vital elements, it is important to know when these environmental necessities may be contaminated, in order to eliminate exposure immediately. The ability to respond requires an understanding of the conditions impacting safety and quality, from source to tap for water, and from outdoor to indoor environments for air. Unfortunately, the "time-to-know" is not immediate with many current technologies, which is a major problem, given the greater likelihood of risky situations in today s world. Accelerating alert and response times requires new tools, methods, and technologies. New solutions are needed to engage in more rapid detection, analysis, and response. This is the focus of a company called PureSense Environmental, Inc., which evolved out of a unique relationship with NASA. The need for real-time management and operations over the quality of water and air, and the urgency to provide new solutions, were reinforced by the events of September 11, 2001. This, and subsequent events, exposed many of the vulnerabilities facing the multiple agencies tasked with working in tandem to protect communities from harmful disaster. Much has been done since September 11 to accelerate responses to environmental contamination. Partnerships were forged across the public and private sectors to explore, test, and use new tools. Methods and technologies were adopted to move more astutely from proof-of-concept to working solutions.

Source record↗

Operational Evaluation of NASA SPoRT Lightning Safety Applications for Impact Based Decision Support Services

The NWS Office in Huntsville is tasked with monitoring and predicting the threat for lightning within its County Warning Area. These impact-based decision support services (IDSS) are provided routinely for aviation operations, irregularly for large-scale, outdoor events, and can have varying safety requirements, such as proximity to location and duration. Lightning monitoring and prediction can require the rapid synthesis of a plethora of data, so products that make this process more efficient and effective are sought by the operational community. The Huntsville NWS Office benefits from close collaboration with the NASA SPoRT Center, which is developing several products to address these operational challenges in concentrated R2O/O2R efforts. One example of this is the StopLight product, which uses Geostationary Lightning Mapper (GLM) flash extent density (FED) to provide an easy-to-interpret visual aid of lightning occurring within the last 30 minutes. The StopLight product shows both the age and location of the last lightning flash within each GLM pixel, which can be particularly useful for IDSS with determining when to resume activities or operations that have been shut down due to lightning. This presentation highlights results of collaboration between NASA SPoRT and NWS Huntsville, including testing of the Stoplight product, and additional experimental products in development. A brief summary of the lightning products are provided while the main focus will discuss product evaluation and forecaster perspective during real-time weather watch activities to support aviation operations and events where IDSS was necessary.

Kristopher White↗

Emergent Degradation Phenomena Demonstrated on Resilient, Flexible, and Scalable Integrated Photoelectrochemical Cells

Photoelectrochemical (PEC) water splitting provides a pathway to generate sustainable clean fuels using the two most abundant resources on Earth: sunlight and water. Currently, most of the successful models of PEC cells are still fabricated on small scales near 1 cm 2 , which largely limits the mass deployment of solar-fuel production. Here, the scale-up to 8 cm 2 of an integrated PEC (IPEC) device is demonstrated and its performance compared to a 1 cm 2 IPEC cell, using state-of-the-art iridium and platinum catalysts with III–V photoabsorbers. The initial photocurrents at 1 sun are 8 and 7 mA cm -2 with degradation rates of 0.60 and 0.47 mA cm -2 day -1 , during unbiased operation for the 1 and 8 cm 2 devices, respectively. Additionally, evaluating under outdoor and indoor conditions at two U.S. National Laboratories reveals similar results, evidencing the reproducibility of this design's performance. Furthermore, the emerging degradation mechanisms during scale-up are investigated and the knowledge gained from this work will provide feedback to the broader community, since PEC device durability is a limiting factor in its potential future deployment.

25 ENERGY STORAGE↗

Sensitivity Analysis of Drivers Water Shortage in the Los Angeles Region During Drought

The code and detailed step-by-step instructions for generating the model output data, processing results, and analysis and plotting are provided at https://github.com/IMMM-SFA/Ferencz_et_al_2026_ER_Water. The PyArtes model is a python adaptation of the Artes model. PyArtes uses many of the same input data and optimization model architecture as Artes. Documentation for the PyArtes model is provided in the Supplement to the paper. The primary data product are simulated monthly water shortages for indoor and outdoor demand under a large ensemble of drought scenarios (>13,000). The droughts are hypothetical and are not based on historical time series data of supply sources - though historical data did help inform ranges explored for supply parameters. Demands are informed by recent 2017-2021 water supply data. Demands used for the model can be accessed at https://github.com/IMMM-SFA/Ferencz_et_al_2026_ER_Water. Simulations resolve demand for over 90 water providers in the study region. The results report 36 months of water shortage data for each indoor and outdoor demand node. The study also developed a multilayer perceptron (MLP) neural network trained on a subset of the simulated shortage ensemble to emulate worst annual water shortage for a given set of parameter multipliers -- provided the parameter values fall within the ranges sampled in the ensemble. Emulated water shortages for synthetic ensembles are in the MLP-generated shortages folder. The MLP model was used to generate larger ensembles to support Sobol analysis that would have been extremely computationally expensive to simulate. Datasets provided in this repository*: Simulated shortages. These results are used for the analysis for Figures 5, 8, and 9 in the paper, and also to train the MLP emulator. .zip file containing outputs for the 13,312 scenario ensemble. Separate .csv files for indoor and outdoor shortage for each scenario. Rows = demand ids (~100), Columns = months (36) Units = acre-feet/month of shortage (shortage = monthly demand - supply). 1 acft = 1233.48 m^3 .csv files of aggregated shortages derived from the 13,312 ensemble Rows = scenarios (13,312), Columns = demand ids (~100) Units = acre-feet/year (either worst annual shortage or total shortage over the 3-year drought) .csv file of the parameter multipliers scenarios for the ensemble .csv file of the parameter ranges and baseline values the multipliers were applied to MLP-generated shortages. These results are used for Figures 4, 6, and 7 in the paper. mwd higher folder: scenario ensembles, emulated worst year total shortages (acft), and Sobol results Emulated shortages. Rows = scenarios, columns = demand ids, units acft Sobol results. Rows = demand ids, columns Sobol (S1, ST, or 95% confidence interval) value for each parameter mwd lower folder: scenario ensembles, emulated worst year total shortages (acft), and Sobol results same organization as mwd higher MLP performance: performance metrics (R^2, RMSE, BIAS, MAPE) for the testing subset (20% or 2,662 scenarios) and simulated vs emulated worst year shortage (acre-feet/year) for every demand node, MWD wholesale regions, and the entire study region (LAC). Supporting data for figures. Figure plotting scripts in the associated GitHub repo. These files support analysis and visualization. Geospatial Data used for plotting simulated water shortages and Sobol results. Dictionary of full names for demand nodes in the model and estimates of water supply by source type informed by Artes input files and California Urban Water Management Planning data: https://water.ca.gov/Programs/Water-Use-And-Efficiency/Urban-Water-Use-Efficiency/Urban-Water-Management-Plans *Readme files provided for each folder.

drought↗

Urban morphology and urban water demand evolution in the Los Angeles region

Detailed description of the dataset sources used in this study, the experimental workflow, and plotting for the paper figures provided at the associated GitHub Meta Repo: https://github.com/IMMM-SFA/Ferencz_et_al_2024_ERL The future water demand projections from this study are hypothetical future water demands that reflect the population and urban land cover changes represented by the scenarios considered. The intent and emphasis of this work is investigating the interactions between population change, evolution of urban morphology, and water demand. These projections are not meant to be likely future demands for specific water providers or the LA region and should not be interpreted as such. The folders contain input and output data for each step of the "Recreate my Experiment" workflow described in the associated GitHub meta-repository as well as data used for plotting Figures for the paper that this dataset supports. Description of each folder's contents and use: Step_1a: All necessary inputs to the associated python script provided on the GitHub repo. Step_1b: All necessary inputs (downscaled population rasters) used by the associated python script provided on the GitHub repo. Original 1-km squared rasters that were downscaled also provided. Step_1c: Urban growth projection rasters corresponding to SSP3 and SSP5 population scenarios are provided in separate subfolders as well as the water provider boundaries used for analysis. Outputs of data processing also provided. Associated python script provided on GitHub. Step_1d: Description of Inputs used by the QGIS Model Builder GUI that automates geospatial processing and clipping the of the high resolution land cover data for each urban land class footprint within a defined polygon boundary. The Model Builder is provided on the GitHub repo and can be used by QGIS. The outputs of this step are in "Clipped Provider Hi Res Landcover". If the user wants to use The Model Builder for different regions of LA or two test our outputs, they will need to download the hi resolution landcover raster listed in the Readme and in Ref [2] of the GitHub Page. Step_1e: All necessary inputs to generate average monthly demand for each water provider. Associated python script on GitHub. Step 2: Output data about land cover metrics (areas and fractions) for each urban land class for each water provider. Associated python script on GitHub. Uses outputs from Step 1d "Clipped Provider Hi Res Landcover" Step 3: Inputs for and Outputs from the urban projection raster analysis Python script on GitHub. The outputs are rasters of urban pixels that were converted to a higher land class and the number of land class units that changed (Values of 1, 2, or 3). For example, a value of 2 could be LC 21 -> 23 or LC 22 -> 24. These maps are label "intensification." The other outputs are "urban growth" rasters showing the conversion of non urban to urban land, which are indicated by pixel values of 1. Step 4: Output projections of indoor and outdoor annual and monthly demands for each water provider. These are used for Figures 4 - 7 of the paper. Figures: This folder has data used for plotting Figures 1 through 5. Data for Figures 6 and 7 are sourced directly from folders associated with the Processing and Analysis Steps 1 - 4 and the plotting scripts for Figures 6 and 7 are commented with what folder paths are needed to generate the figures. The GitHub page provides descriptions of how each figure was made and the associated plotting scripts used.

Los Angeles↗

Study of noise sources in a subsonic fan using measured blade pressures and acoustic theory

Sources of noise in a 1.4 m (4.6 ft) diameter subsonic tip speed propulsive fan running statically outdoors are studied using a combination of techniques. Signals measured with pressure transducers on a rotor blade are plotted in a format showing the space-time history of inlet distortion. Study of these plots visually and with statistical correlation analysis confirms that the inlet flow contains long, thin eddies of turbulence. Turbulence generated in the boundary layer of the shroud upstream of the rotor tips was not found to be an important noise source. Fan noise is diagnosed by computing narrowband spectra of rotor and stator sound power and comparing these with measured sound power spectra. Rotor noise is computed from spectra of the measured blade pressures and stator noise is computed using the author's stator noise theory. It is concluded that the rotor and stator sources contribute about equally at frequencies in the vicinity of the first three harmonics of blade passing frequency. At higher frequencies, the stator contribution diminishes rapidly and the rotor/inlet turbulence mechanism dominates. Two parametric studies are performed by using the rotor noise calculation procedure which was correlated with test. In the first study, the effects on noise spectrum and directivity are calculated for changes in turbulence properties, rotational Mach number, number of blades, and stagger angle. In the second study the influences of design tip speed and blade number on noise are evaluated.

Hanson, D. B.↗

Sub-Surface Windscreen for the Measurement of Outdoor Infrasound

A windscreen has been developed that features two advantages favorable for the measurement of outdoor infrasound. First, the sub-surface location, with the top of the windscreen flush with the ground surface, minimizes the mean velocity of the impinging wind. Secondly, the windscreen material (closed cell polyurethane foam) has a sufficiently low acoustic impedance (222 times that of air) and wall thickness (0.0127 m) to provide a transmission coefficient of nearly unity over the infrasonic frequency range (0-20 Hz). The windscreen, a tightly-sealed box having internal dimensions of 0.3048 x 0.3048 x 0.3556 m, contains a microphone, preamplifier, and a cable feed thru to an external power supply. Provisions are made for rain drainage and seismic isolation. A three-element array, configured as an equilateral triangle with 30.48 m spacing and operating continuously in the field, periodically receives highly coherent signals attributed to emissions from atmospheric turbulence. The time delays between infrasonic signals received at the microphones permit determination of the bearing and elevation of the sources, which correlate well with locations of pilot reports (PIREPS) within a 320 km radius about the array. The test results are interpreted to yield spectral information on infrasonic emissions from clear air turbulence.

Shams, Qamar A.↗

All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control

This is the final report for the project “All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control”, funded by DOE, and performed by Clemson University, Phase IV Engineering and Harvard University from October 1, 2016 to December 31, 2020. The main objective of this project is to develop, demonstrate and pre-commercialize a novel, plug & play, battery-free, wireless sensor technology to enable low-cost (<$10 per node) indoor and outdoor temperature and humidity measurement for energy efficient building controls and operations. The proposed technology is based on the novel concept of all-digital sensing and its seamless integration with the passive RFID technology. This project focuses on the design, fabrication, material optimization, interrogation electronics, validation, and demonstration of the novel sensor nodes for building applications. The specific objectives of this research program include: (1) Design, fabricate and optimize a compact, robust, and high-resolution digitizer, which could convert rotation angle into digital numbers. (2) Develop the multi-physics-based modeling and simulation of the temperature/humidity transducer to derive a rational design of the architecture, dimension, structure, materials (i.e., mechanical, electrical, thermal and hygroscopic) properties and functions of the sensor node. (3) Design, fabricate and optimize the bi-material based humidity sensitive coil which could linearly transduce the environmental relative humidity variations to rotation angles. (4) Design, fabricate and optimize an UHF RFID platform which could support long-range passive wireless communications of 8-bit digital numbers. (5) Design, fabricate and optimize the miniaturized all-digital sensor using MEMS technology. (6) Validate the integrated all-digital sensing system in a real building environment to test the system’s performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PVDeg: Development of a Streamlined Tool for PV Degradation Modeling

The photovoltaic (PV) industry constantly aims for lower costs, higher-efficiency cells, and improved module designs. These trends lead to using new materials, designs, and manufacturing processes, resulting in a continually changing technological landscape. These changes can potentially introduce new, unknown degradation mechanisms and failure modes that are difficult to diagnose, analyze, test, and model. This introduces uncertainty into the expected lifetime of PV modules of 25 to 50 years. research efforts aim to achieve this while keeping performance degradation at a minimum for decades. This puts considerable pressure on improving the accuracy of long-term durability and reliability assessments. There is a need to organize the existing degradation data into an accessible format and to provide industry relevant tools for extrapolation from laboratory to field conditions. Because the core of this type of analysis involves calculations that are complicated but ubiquitous for many degradation processes, an enhanced predictive modeling framework will facilitate the analysis to help researchers keep up with the rapid pace of technological changes. In this work, we present an online tool that can be used to search for and analyze degradation information and extrapolate PV module performance and durability to field exposure. The tool will simplify many of the routine computational operations that are common to many degradation studies. The prediction tool will be built modular and published as open source, enabling users to expand on the existing framework. This repository will contain various degradation models and material parameters suitable for the reliability and durability assessment of materials and components deployed outdoors.

degradation↗

UV + Damp Heat Induced Power Losses in Fielded Utility N-Type Si PV Modules

A recent trend in commercial PV modules is a transition to n-type silicon cells, including passivated emitter rear totally diffused (n-PERT), tunnel oxide passivated contact (TOPCon), and silicon heterojunction (SHJ). There is evidence via lab studies that some of these cells are more susceptible to UV induced degradation (UVID), yet there is a lack of confirmation that such degradation occurs in the field. Current IEC standards designed to screen for early module failures require only minimal UV exposure (15 kWh/m2 280-400 nm, ~2-3 months equivalent outdoor exposure). Here, we investigate fielded n-PERT silicon (Si) modules from a commercial utility that show power losses of ~2%/year. We present a comprehensive picture of the physics and chemistry of degradation supported by both module and cell electronic characterization (EL, PL, IV, EQE, and DLIT) and materials-level morphological and chemical analysis (SEM, EDS, XPS, FTIR, and HPLC). All sampled site modules show short circuit current (Isc) and open circuit voltage (Voc) losses when compared to unfielded spares, with the most severely degraded also having losses in fill factor (FF). We identify two different degradation modes contributing to overall power loss: (1) external quantum efficiency (EQE) measurements show losses in the blue range of the spectra, indicative of cell surface recombination losses, and (2) variations in high series resistance (Rs) at the cell level that are correlated with compositional differences in cell metallization. Using unfielded spares, we were able to reproduce Voc, Isc, and EQE losses via a minimum UV stress of 67.5 kWh/m2 (280-400 nm), 4.5x the exposure currently required in IEC 61215-2 (MQT 10). Degradation continued with additional UV dosage equivalent to the fielded modules (405 kWh/m2 total), with power loss leveling out at an average of 6.1%. Subsequent 1000 h of 85% RH/85degrees C damp heat testing showed that cells exposed to UV underwent additional severe series resistance degradation, even those without the susceptible paste composition seen in the field, whereas non-UV exposed cells saw little change. We attribute this to higher concentrations of acetic acid generated on the UV exposed area of the module, leading to degradation of the gridline/cell interface and high Rs. This study is unique in that it reproduces field observed utility scale UVID with an accelerated test and supports the need for standards development for longer UV exposure combined with other stress factors to catch materials interplay within a module package.

14 SOLAR ENERGY↗

Experimental comparison of pyranometer, reflectometer, and spectrophotometer methods for the measurement of roofing product albedo

Albedo (solar reflectance) can be measured outdoors with a pyranometer or indoors with a hemispherical reflectometer or a spectrophotometer. The current study evaluates these methods and their applicability to roofing materials by measuring and comparing the ASTM E1918 (pyranometer), non-ASTM E1918A (alternative pyranometer), ASTM C1549 (reflectometer), and E903 (spectrophotometer) albedos of 10 roofing products, including three single-ply membranes, one asphalt shingle, three roofing aggregates, and three high-profile tiles. It uses full-size (4 m × 4 m) assemblies in the E1918 and E1918A trials; corrects the E1918 albedos to remove shadow and background errors; and evaluates C1549 and E903 albedos with two different irradiance spectra, one global horizontal and the other beam normal. E1918A albedos matched E1918 corrected (E1918_cor) albedos to within 0.036. Furthermore, agreement between C1549 air mass 1 global horizontal (C1549_G1) albedo and E1918_cor albedo was within 0.015 for membrane and shingle coupons, and within 0.031 for aggregates, though the uncertainty in the latter agreement was up to 0.043. After minor corrections, C1549_G1 albedos of flat or slightly convex tile chips were 0.032–0.052 higher than the E1918_cor albedos of their corresponding high-profile tile assemblies because high-profile surfaces have concavities. Switching to the beam-normal albedo C1549_1.5E increased the C1549 albedos of the 10 tested products by 0.004–0.054, with the largest increases (C1549_1.5E – C1549_G1) accruing to spectrally selective cool colors. Using C1549_1.5E albedo to characterize a chip of a cool-colored tile compounded the error induced by representing a high-profile surface by a flat or slightly convex specimen.

14 SOLAR ENERGY↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 3: Optical properties of black and brown carbon emissions

Residential biomass combustion is a source of carbonaceous aerosol. Inefficient combustion, particularly of solid fuels produces large quantities of black and brown carbon (BC and BrC). These particle types are important as they have noted effects on climate forcing and human health. One method of measuring these quantities is by measurement of aerosol light-absorption and scattering, which can be performed using an aethalometer and nephelometer, respectively. These instruments are widely deployed in the study of ambient air and are frequently used in air quality modeling and source apportionment studies. In this study, we will describe (1) a method for measuring primary BC and BrC emissions from two residential log-fired wood hydronic heaters and (2) the BC and BrC emission from these devices over a wide range of operating conditions, such as cold-starts, warm-starts, four different levels of output ranging from 15% to 100% maximum rated output, and periods of repeated cycling. The range in flue-gas BC concentrations, measured using an aethalometer at the 880 nanometer (nm) wavelength, were between 5.09 × 10 2 and 2.24 × 10 4 micrograms per cubic meter (µg/m 3 ) while the scattering coefficient of the flue-gas, measured by a nephelometer at 880 nm, ranged between 2.20 × 10 3 and 8.56 × 10 5 inverse megameters (Mm –1 ). The BrC concentrations, measured using the 370 nm wavelength of an aethalometer, were between 9.10 × 10 1 and 3.56 × 10 4 µg/m 3 . The calculated Angstrom Absorption Exponent (AAE) of the flue-gas aerosol ranged between 1.54 and 3.63. Performing a comparison between the measured BC concentration and an external particulate matter (PM) concentration showed that overall BC makes up roughly a quarter of the PM emitted by either of the two appliances. Further for both appliances, the cold-start and the test phase immediately following it had the highest BC and BrC concentrations, the highest measured scattering coefficient, as well as a low AAE.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Urban morphology and urban water demand evolution in the Los Angeles region

Detailed description of the dataset sources used in this study, the experimental workflow, and plotting for the paper figures provided at the associated GitHub Meta Repo: https://github.com/IMMM-SFA/Ferencz_et_al_2024_ERL The future water demand projections from this study are hypothetical future water demands that reflect the population and urban land cover changes represented by the scenarios considered. The intent and emphasis of this work is investigating the interactions between population change, evolution of urban morphology, and water demand. These projections are not meant to be likely future demands for specific water providers or the LA region and should not be interpreted as such. The folders contain input and output data for each step of the "Recreate my Experiment" workflow described in the associated GitHub meta-repository as well as data used for plotting Figures for the paper that this dataset supports. Description of each folder's contents and use: Step_1a: Inputs to the associated python script provided on the GitHub repo. Step_1b: Inputs (downscaled population rasters) used by the associated python script provided on the GitHub repo. Original 1-km squared rasters that were downscaled also provided. Step_1c: Urban growth projection rasters corresponding to SSP3 and SSP5 population scenarios are provided in separate subfolders as well as the water provider boundaries used for analysis. Outputs of data processing also provided. Associated python script provided on GitHub. Step_1d: Description of Inputs used by the QGIS Model Builder GUI that automates geospatial processing and clipping the of the high-resolution 60 cm land cover data for each urban land class footprint within a defined polygon boundary. The Model Builder is provided on the GitHub repo and can be used by QGIS. The outputs of this step are in "Clipped Provider Hi Res Landcover". If the user wants to use The Model Builder for different regions of LA or to test our outputs, they will need to download the hi resolution landcover raster listed in the Readme and in Ref [2] of the GitHub Page. Step_1e: All necessary inputs to generate average monthly demand over the 2017-2021 period and the minimum and maximum demands over the 2014-2021 for each water provider. Associated python scripts are on GitHub. Step 2: Output data about land cover metrics (areas and fractions) for each urban land class for each water provider. Associated python script on GitHub. Uses outputs from Step 1d "Clipped Provider Hi Res Landcover" Step 3: Both the Inputs for and Outputs from the urban projection raster analysis Python script on GitHub. The inputs are urban land class rasters for specific SSP and zoning scenarios (low, medium, high) from Step 1c. The outputs are rasters of urban pixels that were converted to a higher land class and the number of land class units that changed (Values of 1, 2, or 3). For example, a value of 2 could be LC 21 -> 23 or LC 22 -> 24. These maps are label "intensification." The other outputs are "urban growth" rasters showing the conversion of non urban to urban land, which are indicated by pixel values of 1. These are used for the urban growth change maps in Figure 3. Step 4: Output projections of indoor and outdoor annual and monthly demands for each water provider for the average, minimum, and maximum monthly demand scenarios for each of the four urban growth scenarios (SSP3 med, SSP5 low, SSP5 med, and SSP5 high). The outputs also include metrics on each water provider used for the demand sensitivity analysis presented in Figure 8. Outputs from Step 4 are used for Figures 4 - 8 of the paper. Figures: This folder has data used for plotting Figures 1 through 5, and 8. Data for Figures 6 and 7 are sourced directly from folders associated with the Processing and Analysis Steps 1 - 4. The GitHub meta repository provides descriptions of how each figure was made and the associated plotting scripts used.

Los Angeles↗

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field retrieved photovoltaic backsheet survey from diverse climate zones: Analysis of degradation patterns and phenomena

Understanding the impact of climate stressors on photovoltaic (PV) backsheet degradation in real-use conditions is critical to improve the accelerated testing exposures, extend the backsheet lifetime, and increase the confidence in PV reliability. Here, in this work, a total of 33 PV module backsheets were retrieved from six climatic zones worldwide with 2 - 28 years of exposure. These modules included five types of backsheet air-side materials (or outer layer): poly(vinylidene fluoride) (PVDF), poly(tetrafluoroethylene-co-hexafluoropropylene-co-vinylidene fluoride) (THV), poly(vinyl fluoride) (PVF), poly(ethylene terephthalate) (PET), and polyamide (PA). Attenuated total reflection Fourier-transform infrared spectroscopy (ATR-FTIR) was used to identify air-side materials. The degradation induced color change, gloss loss, and chemical material changes analyzed using optical microscopy, differential scanning calorimetry (DSC), scanning electron microscopy (SEM), colorimetry (yellowness index (YI)), and gloss measurements. PVDF, THV, and PVF air-side layer backsheets, in particular PVF, had minimal degradation in the air-side layer appearance and chemical structures after exposure in different climatic zones. The PET air-side backsheets exhibited obvious color increase (22.55 YI units after about 9 years exposure) and the PA/PA/PA backsheets showed large gloss loss (up to 76.4 %) relative to the unexposed backsheets. Severe cracks between cells that penetrated through the entire thickness of backsheets are observed on PA/PA/PA backsheets after 4-6 years of exposure in 6 climatic zones. The current indoor exposure standards were not sufficient to identify this degradation type. However, fluoropolymer based PV backsheets showed lower levels of degradation predictors and increased climatic resistance. Specific samples (PVF) showed little change from baseline after 28 years of outdoor exposure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Bayesian Learning Approach to Wireless Outdoor Heatmap Construction using Deep Gaussian Process

We present a novel Bayesian learning approach to outdoor radio heatmap construction utilizing deep Gaussian process (GP). The proposed approach employs a two-layer hierarchy which consists of two cascaded Gaussian processes that are capable of modeling more complex input-output relations than standard single-layer Gaussian processes. Since deriving the exact model likelihood is challenging, a lower bound is optimized instead so that gradient descent-based methods can be performed to find out the optimal model parameters. Typically, inducing points are used in GPs to facilitate low-rank approximation of covariance (kernel) matrices for computation speedup. However, the inaccuracy induced by inducing points can accumulate when stacking multiple layers of GP which may hinder the performance of deep GP. Moreover, since inducing points need to be learned, having them at all layers of deep GP also incurs computational burden. To overcome the above challenges, in contrast to the canonical deep GP model, we use a modified architecture where a full standard GP resides in the first layer and inducing points are only introduced for the second layer. This modified architecture strikes a balance between model accuracy and training complexity. In the proposed model, the noise parameter of the first GP layer is also eliminated to improve the training efficiency as the noise parameter at the output of the second layer suffices to model the uncertainty in the output. The proposed approach is evaluated on real-world datasets, in the form of location-Received Signal Strength (RSS) pairs, collected from the Platform for Open Wireless Data-driven Experimental Research (POWDER) located at the campus of the University of Utah. Experiment results show that the proposed approach can achieve smaller prediction errors on various training and testing data configurations than DNN-based and GP-based methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation, Challenge Testing and Validation of Solutions for Residential and Commercial Occupancy Sensing/Counting and CO2 Sensing (Final Report)

Carbon dioxide sensors used for monitoring and control applications in buildings are known to be sensitive to long term drift and can be affected by variations in temperature, humidity, other gas interferents, pressure and other factors that cannot be corrected through the typical auto-calibration methods often embedded in the sensor electronics. This investigation was part of the Category D defined in the ARPA-E Saving Energy Nationwide in Structures With Occupancy Recognition (SENSOR) Financial Assistance Funding Opportunity Announcement No. DE-FOA-0001737, FFDA No. 81.135, January 18, 2017. The FOA defined target criteria for the evaluation of the Category C commercial CO2 sensors selected for review and development through the ARPA-E SENSOR program and charged the Iowa State Category D team with developing an evaluation methodology for Category C sensors in accordance with these criteria. As part of the work, the Iowa State team chose to engage the standards community in the development of the evaluation methodology. Standard development work in the D22.05 Indoor Air and D22.03 Ambient Atmospheres and Source Emissions subcommittees of ASTM International Committee D22 on Air Quality on the evaluation of low cost sensors and provision of guidance for using indoor carbon dioxide concentrations to evaluate indoor air quality and ventilation is of particular relevance to the Category D efforts. To date, three draft standards with specific input by the Iowa State Category D team have passed the subcommittee balloting stage and are being balloted in December 2022 and January 2023 in the main D22 committee. In addition to the aforementioned standards to which the PI was a contributing author, intellectual property developed in this project pertaining to “An Automated System for Evaluation of the Long Term Performance of Carbon Dioxide Sensors” and “An Automated Ground Truth System for Real-Time Reliability Assessment, Capture of Control Decisions and Energy Savings Measurements for Occupancy Recognition Systems and Other Applications” are the other major deliverables of the project. These standards and the developed intellectual property are expected to benefit the public in a number of ways stemming from their provision of means to benchmark the performance of carbon dioxide and other sensor systems. In particular, there is high interest in techniques to demonstrate the performance of low-cost carbon dioxide sensors which can be used for typical HVAC applications (e.g., demand controlled ventilation, outdoor and indoor air monitoring, estimation of occupancy, etc.).

42 ENGINEERING↗