Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical pulses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Dynamics and energy coupling of gas puff Z-pinches on a fast linear transformer driver

Gas puff Z-pinch experiments with annular Ar and Ne gas shells have been conducted on the Compact Experimental System for Z-pinch and Ablation Research (CESZAR) linear transformer driver (LTD) with 500 kA current and 160 ns rise time. Here, we present results from the first systematic gas puff Z-pinch experiments using a fast (≤ 200 ns) LTD as a driver, in which we show that 7% of the stored energy in the capacitors is coupled to plasma kinetic energy as estimated via self-emission and laser schlieren images. 0D and 1D simulations—which do not allow instability growth and thus reach greater maximum average velocities—using initial conditions inferred from experimental implosion trajectories predict coupling in excess of 10% of the stored energy. Additionally, the Ar and Ne implosions were comparably massed and thus achieved similar maximum kinetic energies, though the Ne pinches were more stable and the x-ray pulses were longer and produced higher yield: 2–5 ns and 0.21–0.52 J (0.15–0.37 J/cm) of Ar K-shell and 12–25 ns and 2.2–3.9 J (1.6–2.6 J/cm) of Ne K-shell, respectively. The difference in stability is most likely attributed to variations in initial conditions such as density distribution and gas breakdown initiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In-orbit operation of Resolve Filter Wheel and modulated X-ray source

The Resolve soft X-ray spectrometer is a high spectral resolution microcalorimeter spectrometer for the X-ray Imaging and Spectroscopy Mission. In the beam of Resolve, there is a filter wheel containing X-ray filters. In the beam, there is also an active calibration source, the modulated X-ray source (MXS), which can provide pulsed X-rays to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one 55 Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of an MXS are highly configurable. Furthermore, the switch-on time is synchronized with the spacecraft’s internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of an MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, we will discuss the calibration source and the filter performance in-flight and compare with the transmission curves present in the Resolve calibration database.

X-ray Imaging and Spectroscopy Mission/Resolve↗

High-speed volumetric imaging of formaldehyde in a lifted turbulent jet flame using an acousto-optic deflector

The development of high-speed volumetric laser-induced fluorescence measurements of formaldehyde (CH 2 O-LIF) using a pulse-burst laser operated at a repetition rate of 100 kHz is presented here. A novel laser scanning system employing an acousto-optic deflector (AOD) enables quasi-4D CH 2 O-LIF imaging at a scan frequency of 10 kHz. The diagnostic capability of time-resolved volumetric imaging is demonstrated in a partially premixed DME/air lifted turbulent jet flame near the flame base. Simultaneous imaging of laser beam profiles is performed to account for the laser pulse energy fluctuation and laser sheet inhomogeneity. With the accurate registration of laser sheet positions, the volumetric reconstruction of CH 2 O-LIF signals is performed within a detection volume of 17.3 × 11.9 × 2.3 mm 3 with an average out-of-plane spatial resolution of 250μm. A surface detection algorithm with adaptive thresholding is used to determine the global maximum intensity gradient by calculating gradient percentiles. The flame topology characteristics are investigated by evaluating the 3D curvatures of CH 2 O surfaces. Curvatures calculated using 2D data systematically underestimate the full 3D curvature due to the lack of out-of-plane information. The inner surfaces near the turbulent fuel jet exhibit higher probabilities of large mean curvature than the outer surfaces. The saddle and cylindrical structures are dominant on both the inner and outer surfaces and the elliptic structures occur with lower probability. The results suggest that the damping of turbulent fluctuations by the temperature increase through the CH 2 O region reduces the curvature, but the local structure topology remains self-similar.

42 ENGINEERING↗

Crystallization of TiO 2 polymorphs from RF-sputtered, amorphous thin-film precursors

Crystalline TiO 2 films of anatase, brookite, and rutile are reproducibly made from amorphous precursors deposited by RF magnetron sputtering, producing large-area, single phase films of uniform thickness. Sputtered amorphous TiO 2 precursor thin films follow the general behavior observed for amorphous precursor thin films generated by pulsed laser deposition, namely, that oxygen deficiency is necessary for the formation of brookite and rutile. We quantify the oxygen deficiency and correlate it with the long wavelength optical absorption. We find that the precursor deposition rate is also a contributing factor to phase selection and that brookite and rutile form from films deposited more rapidly and anatase from films deposited more slowly. Sputtered and pulsed laser deposited amorphous precursor films prepared with similar oxygen deficiency and similar thickness result in the same final state after annealing, but the rate for sputtered precursors is slower.

14 SOLAR ENERGY↗

High-power non-perturbative laser delivery diagnostics at the final focus of 100-TW-class laser pulses

Controlling the delivery of multi-terawatt and petawatt laser pulses to final focus, both in position and angle, is critical to many laser applications such as optical guiding, laser–plasma acceleration, and laser-produced secondary radiation. We present an online, non-destructive laser diagnostic, capable of measuring the transverse position and pointing angle at focus. The diagnostic is based on a unique double-surface-coated wedged-mirror design for the final steering optic in the laser line, producing a witness beam highly correlated with the main beam. By propagating low-power kilohertz pulses to focus, we observed spectra of focus position and pointing angle fluctuations dominated by frequencies below 70 Hz. The setup was also used to characterize the excellent position and pointing angle correlation of the 1 Hz high-power laser pulses to this low-power kilohertz pulse train, opening a promising path to fast non-perturbative feedback concepts even on few-hertz-class high-power laser systems.

47 OTHER INSTRUMENTATION↗

Production of high fluence laser beams using ion wave plasma optics

Optical components for laser beams with high peak and averaged powers are being developed worldwide using stimulated plasma scattering that occurs when plasmas interact with intense, coherent light. After decades of pursuit of pulse compressors, mirrors, and other plasma based components that can be created by stimulated scattering from electron density perturbations forming on ultra-short time scales (e.g., via Stimulated Raman Scattering), more recent work has produced optical components on longer time scales allowing ion motion as well [via Stimulated Brillouin Scattering (SBS)]. In the most recent work, ion wave plasma optics have had success in producing pulses of focusable coherent light with high energy and fluence by operating on ns time scales and now promise to enable numerous applications. Experiments have further shown that in some parameter regimes, even simple plasma response models can describe the output of such optics with sufficient accuracy that they can be used as engineering tools to design plasma optics for future applications, as is already being done to control power deposition in fusion targets. In addition, the development of more sophisticated models promises to enable still higher performance from SBS driven plasma optical components under a wider range of conditions. The present status and most promising directions for future development of ion wave plasma optic techniques are discussed here.

47 OTHER INSTRUMENTATION↗

Petahertz electronics

Petahertz, or lightwave, electronics uses tailored optical waveforms to control charge carriers in an electronic circuit at petahertz frequencies. This may enable faster processing than conventional pulsed electronics, which cannot be scaled beyond gigahertz frequencies. In recent years, petahertz-scale currents driven by optical fields have been measured in solid-state systems and nanoscale structures, with several proof-of-principle demonstrations of sub-optical-cycle current generation and optical-field-resolved waveform detection at the sub-femtosecond to few-femtosecond scale. Recent work has taken the first steps towards digital and quantum operation by exploring optical-field-driven logic and memory functionality. Here, in this Review, we discuss the progress towards sub-cycle field-driven current injection, highlighting key theoretical concepts, experimental milestones, and questions remaining as we push towards realizing petahertz electronics for ultrafast optical waveform analysis, digital logic, communications, and quantum computation.

Heide, Christian↗

Towards optimal gas cooling with minimal aero-optical distortion for a laser amplifier head

Next-generation lasers combining high-peak-power, ultrashort pulses with high repetition rates have the potential to efficiently deliver the high-average-power outputs required by many emerging technologies and areas of research. This work introduces a three-stage workflow consisting of low- and high-fidelity fluid simulations, in addition to aero-optical analyses. The final goal is to optimize gas cooling within a laser amplifier head while maintaining minimal aero-optical distortions. Low-fidelity RANS simulations are used to obtain mean flow solutions and transition locations. High-fidelity LES simulations, informed by their RANS counterparts, provide solutions containing density fluctuations, which are then passed on to the aero-optical analysis. The aero-optical analysis provides insight into the optical quality of the laser beam passing through the flow found in the LES results.

42 ENGINEERING↗

Programmable, direct space-to-time picosecond resolution pulse shaper with nanosecond record

In this work, we demonstrate a novel, to the best of our knowledge, extension of optical arbitrary waveform generation capable of picosecond resolution over nanosecond duration. The method, called space–time induced linearly encoded transcription for temporal optimization, is based on direct space-to-time pulse shaping and is extended here to single-mode output with a programmable temporal profile. We develop the theory of operation and discuss ultimate limits on resolution, record length, and efficiency. We report on the results of an experimental demonstration showing ~1ps resolution over 600 ps.

42 ENGINEERING↗

Time-refraction optics with single cycle modulation

Abstract We present an experimental study of optical time-refraction caused by time-interfaces as short as a single optical cycle. Specifically, we study the propagation of a probe pulse through a sample undergoing a large refractive index change induced by an intense modulator pulse. In these systems, increasing the refractive index abruptly leads to time-refraction where the spectrum of all the waves propagating in the medium is red-shifted, and subsequently blue-shifted when the refractive index relaxes back to its original value. We observe these phenomena in the single-cycle regime. Moreover, by shortening the temporal width of the modulator to ∼5–6 fs, we observe that the rise time of the red-shift associated with time-refraction is proportionally shorter. The experiments are carried out in transparent conducting oxides acting as epsilon-near-zero materials. These observations raise multiple questions on the fundamental physics occurring within such ultrashort time frames, and open the way for experimenting with photonic time-crystals, generated by periodic ultrafast changes to the refractive index, in the near future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phased plan for the implementation of the time-resolving magnetic recoil spectrometer on the National Ignition Facility (NIF)

The time-resolving magnetic recoil spectrometer (MRSt) is a transformative diagnostic that will be used to measure the time-resolved neutron spectrum from an inertial confinement fusion implosion at the National Ignition Facility (NIF). It uses a CD foil on the outside of the hohlraum to convert fusion neutrons to recoil deuterons. An ion-optical system positioned outside the NIF target chamber energy-disperses and focuses forward-scattered deuterons. A pulse-dilation drift tube (PDDT) subsequently dilates, un-skews, and detects the signal. While the foil and ion-optical system have been designed, the PDDT requires more development before it can be implemented. Therefore, a phased plan is presented that first uses the foil and ion-optical systems with detectors that can be implemented immediately—namely CR-39 and hDISC streak cameras. These detectors will allow the MRSt to be commissioned in an intermediate stage and begin collecting data on a reduced timescale, while the PDDT is developed in parallel. A CR-39 detector will be used in phase 1 for the measurement of the time-integrated neutron spectra with excellent energy-resolution, necessary for the energy calibration of the system. Streak cameras will be used in phase 2 for measurement of the time-resolved spectrum with limited spectral coverage, which is sufficient to diagnose the time-resolved ion temperature. Simulations are presented that predict the performance of the streak camera detector, indicating that it will achieve excellent burn history measurements at current yields, and good time-resolved ion-temperature measurements at yields above 3 × 10 17 . The PDDT will be used for optimal efficiency and resolution in phase 3.

47 OTHER INSTRUMENTATION↗

Demonstration of plasma mirror capability for the OMEGA Extended Performance laser system

A plasma mirror platform was developed for the OMEGA-EP facility to redirect beams, thus enabling more flexible experimental configurations as well as a platform that can be used in the future to improve laser contrast. The plasma mirror reflected a short pulse focusing beam at 22.5° angle of incidence onto a 12.5 μm thick Cu foil, generating Bremsstrahlung and k α x rays, and accelerating ions and relativistic electrons. By measuring these secondary sources, the plasma mirror key performance metrics of integrated reflectivity and optical quality are inferred. It is shown that for a 5 ± 2 ps, 310 J laser pulse, the plasma mirror integrated reflectivity was 62 ± 13% at an operating fluence of 1670 J cm –2 , and that the resultant short pulse driven particle acceleration and x-ray generation indicate that the on target intensity was 3.1 × 10 18 W cm –2 , which is indicative of a good post-plasma mirror interaction beam optical quality. By deriving the plasma mirror performance metrics from the secondary source scalings, it was simultaneously demonstrated that the plasma mirror is ready for adoption in short pulse particle acceleration and high energy photon generation experiments using the OMEGA-EP system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nickel(II) Metal Complexes as Optically Addressable Qubit Candidates

The inherent atomic level structural control of synthetic chemistry enables the creation of qubits, the base units of a quantum information science system, designed for a target application. For quantum sensing applications, enabling optical read-out of spin in tunable molecular systems, akin to defect-based systems, would be transformative. This approach would bring together molecular tunability with optical read-out technology. In theory, nickel ions in octahedral symmetry meet all the criteria for optical readout of spin. Yet, to the best of our knowledge, there are no pulse EPR studies on Ni 2+ molecules. We identified two compounds featuring highly symmetric Ni 2+ centers, thereby engendering weak zero-field splitting to enable EPR addressability:[Ni(phen) 3 ](BF 4 ) 2 (1) and [Ni(pyr 3 ) 2 ](BF 4 ) 2 (2) (phen = 1,10-phenanthroline; pyr 3 = tris-2-pyridyl-methane). Crucially, these complexes feature the requisite strong field ligands to enable emission for optical addressability. We extracted axial zero-field splitting parameters of D = +0.9 cm –1 and +2.7 cm –1 for 1 and 2, respectively, enabling pulse EPR measurements. Both compounds produce emission at λ max = 938–944 nm. Furthermore, the aggregate of these results expands the catalogue of qubit materials to Ni 2+ -based compounds and offers a future pathway for optical readout of these molecules.

36 MATERIALS SCIENCE↗

Initial transient stage of pin-to-pin nanosecond repetitively pulsed discharges in air

In this work, evolution of parameters of nanosecond repetitively pulsed (NRP) discharges in pin-to-pin configuration in air was studied during the transient stage of initial 20 discharge pulses. Gas and plasma parameters in the discharge gap were measured using coherent microwave scattering, optical emission spectroscopy, and laser Rayleigh scattering for NRP discharges at repetition frequencies of 1, 10, and 100 kHz. Memory effects (when perturbations induced by the previous discharge pulse would not decay fully until the subsequent pulse) were detected for the repetition frequencies of 10 and 100 kHz. For 10 kHz NRP discharge, the discharge parameters experienced significant change after the first pulse and continued to substantially fluctuate between subsequent pulses due to rapid evolution of gas density and temperature during the 100 μs inter-pulse time caused by intense redistribution of the flow field in the gap on that time scale. For 100 kHz NRP discharge, the discharge pulse parameters reached a new steady-state at about five pulses after initiation. Further, this new steady-state was associated with well-reproducible parameters between the discharge pulses and substantial reduction in breakdown voltage, discharge pulse energy, and electron number density in comparison to the first discharge pulse. For repetition frequencies 1–100 kHz considered in this work, the memory effects can be likely attributed to the reduction in gas number density and increase in the gas temperature that cannot fully recover to ambient conditions before subsequent discharge pulses.

42 ENGINEERING↗

Electro-optic sampling based characterization of broad-band high efficiency THz-FEL

Extremely high beam-to-radiation energy conversion efficiencies can be obtained in a THz FEL using a strongly tapered helical undulator at the zero-slippage resonant condition, where a circular waveguide is used to match the radiation group velocity to the electron beam longitudinal velocity. In this paper we report on the first electro-optic sampling (EOS) based measurements of the broadband THz FEL radiation pulses emitted in this regime. The THz field waveforms are reconstructed in the spatial and temporal domains using multi-shot and single-shot EOS schemes respectively. The measurements are performed varying the input electron beam energy in the undulator providing insights on the complex dynamics in a waveguide FEL.

79 ASTRONOMY AND ASTROPHYSICS↗

Two-XUV-photon double ionization of neon

Two XUV-photon double ionization of Ne, induced by an intense few-pulse attosecond train with a ~ 4 fs envelope duration is investigated experimentally and theoretically. The experiment is performed at ELI-ALPS utilizing the recently constructed 10 Hz gas phase high-order harmonic generation SYLOS GHHG-COMPACT beamline. A total pulse energy up to ~1 {\mu}J generated in Argon in conjunction with high reflectivity optics in the XUV region, allowed the observation of the doubly charged state of Ne induced by 40 eV central XUV photon energies. The interaction of the intense attosecond pulse train with Ne is also theoretically studied via a second-order time dependent perturbation theory equations-of-motion. Further, the results of this work, combined with the feasibility of conducting XUV-pump-XUV-probe experiments, constitute a powerful tool for many potential applications. Those include attosecond pulse metrology as well as time resolved investigations of the dynamics underlying direct and sequential double ionization and their electron correlation effects.

74 ATOMIC AND MOLECULAR PHYSICS↗

Acoustic mapping by picosecond ultrasonics for elastic property measurement: Experimental demonstration on a TRISO fuel compact

Picosecond ultrasonics has been demonstrated on a tristructural isotropic (TRISO) fuel compact to measure the elastic properties of each compact layer. This technique utilizes an ultrashort pump laser pulse to excite vibrations in a gold transducer film covering the surface of each component and a second probe laser pulse to record the resulting acoustic strain induced change in optical reflectance. From the damping of this film vibration, the acoustic reflection coefficient, which couples the elastic properties of the transducer film and the sample, can be obtained, enabling a calculation of the sample’s acoustic velocity and elastic modulus. Overall, results obtained from this method are consistent with known values of elastic moduli, namely that the SiC coating is the stiffest component of the compact while the carbonaceous matrix is the most compliant. Nanoindentation was conducted as a benchmark technique on the same sample and shows satisfactory agreement with the results of picosecond ultrasonics. Compared to other methods like nanoindentation, picosecond ultrasonics is multimodal with a capability of measuring several key properties simultaneously and has potentials to be coupled into optical fibers for remote sensing. Thus, these demonstration measurements reveal the methodology to be a promising candidate for in-situ and high-throughput optical characterizations of nuclear materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗