Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Investigations of laser-induced damages in fused silica optics using x-ray laser interferometric microscopy

A novel x-ray laser (XRL) application, aimed at understanding the microscopic effects involved in formation of laser-induced damage in optical materials exposed to high-power sub-ns laser pulses, is presented. Standard fused silica substrates with permanent damage threshold below 20 J/cm{sup 2}, when irradiated by 438 nm laser pulses, were probed in situ by a neonlike zinc XRL at 21.2 nm. The probing beamline employed a double Lloyd's mirror x-ray interferometer, used in conjunction with an imaging mirror to achieve magnification of {approx}8. In conjunction with an array of in situ optical diagnostics, the main question addressed is whether the damage on the rear surface of the beamsplitter is transient or permanent. The second issue, examined by both the x-ray interferometric microscopy and the optical diagnostics, is whether a local rear-surface modification is associated with nonlinear effects such as self-focusing or filamentation of the damaging laser beam in the bulk.

36 MATERIALS SCIENCE↗

Diagnosing collisions of magnetized, high energy density plasma flows using a combination of collective Thomson scattering, Faraday rotation, and interferometry (invited)

A suite of laser based diagnostics is used to study interactions of magnetised, supersonic, radiatively cooled plasma flows produced using the Magpie pulse power generator (1.4 MA, 240 ns rise time). Collective optical Thomson scattering measures the time-resolved local flow velocity and temperature across 7–14 spatial positions. The scattering spectrum is recorded from multiple directions, allowing more accurate reconstruction of the flow velocity vectors. The areal electron density is measured using 2D interferometry; optimisation and analysis are discussed. The Faraday rotation diagnostic, operating at 1053 nm, measures the magnetic field distribution in the plasma. Measurements obtained simultaneously by these diagnostics are used to constrain analysis, increasing the accuracy of interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coriolis force compensation and laser beam delivery for 100-m baseline atom interferometry

The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry, which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.

Glick, Jonah↗

Readout of micromechanical cantilever sensor arrays by Fabry-Perot interferometry

The increasing use of micromechanical cantilevers in sensing applications causes a need for reliable readout techniques of micromechanical cantilever sensor (MCS) bending. Current optical beam deflection techniques suffer from drawbacks such as artifacts due to changes in the refraction index upon exchange of media. Here, an adaptation of the Fabry-Perot interferometer is presented that allows simultaneous determination of MCS bending and changes in the refraction index of media. Calibration of the instrument with liquids of known refraction index provides an avenue to direct measurement of bending with nanometer precision. Versatile construction of flow cells in combination with alignment features for substrate chips allows simultaneous measurement of two MCS situated either on the same, or on two different support chips. The performance of the instrument is demonstrate in several sensing applications, including adsorption experiments of alkanethioles on MCS gold surfaces, and measurement of humidity changes in air.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

Extreme ultraviolet lithography: A few more pieces of the puzzle

The work described in this dissertation has improved three essential components of extreme ultraviolet (EUV) lithography: exposure tools, photoresist, and metrology. Exposure tools. A field-averaging illumination stage is presented that enables nonuniform, high-coherence sources to be used in applications where highly uniform illumination is required. In an EUV implementation, it is shown that the illuminator achieves a 6.5% peak-to-valley intensity variation across the entire design field of view. In addition, a design for a stand-alone EUV printing tool capable of delivering 15 nm half-pitch sinusoidal fringes with available sources, gratings and nano-positioning stages is presented. It is shown that the proposed design delivers a near zero line-edge-rougness (LER) aerial image, something extremely attractive for the application of resist testing. Photoresist. Two new methods of quantifying the deprotection blur of EUV photoresists are described and experimentally demonstrated. The deprotection blur, LER, and sensitivity parameters of several EUV photoresists are quantified simultaneously as base weight percent, photoacid generator (PAG) weight percent, and post-exposure bake (PEB) temperature are varied. Two surprising results are found: (1) changing base weight percent does not significantly affect the deprotection blur of EUV photoresist, and (2) increasing PAG weight percent can simultaneously reduce LER and E-size in EUV photoresist. The latter result motivates the development of an EUV exposure statistics model that includes the effects of photon shot noise, the PAG spatial distribution, and the changing of the PAG distribution during the exposure. In addition, a shot noise + deprotection blur model is used to show that as deprotection blur becomes large relative to the size of the printed feature, LER reduction from improved counting statistics becomes dominated by an increase in LER due to reduced deprotection contrast. Metrology. Finally, this dissertation describes MOSAIC, a new wavefront metrology that enables complete wavefront recovery from print or aerial image based measurements. This new technique, based on measuring the local focal length of the optic at sampled positions in the pupil, recovers the curvature of the aberration and uses the curvature to recover the aberration itself. In a modeled EUV implementation, MOSAIC is shown to recover the SEMATECH Berkeley MET wavefront with a 4.2% RMS error: a 4% improvement over the reported errors of the original lateral shearing interferometry wavefront measurement.

36 MATERIALS SCIENCE↗

Development of Hard X-ray Imaging Optics with Two Pairs of Elliptical and Hyperbolic Mirrors

To form a magnified hard X-ray image with a 50 nm resolution, we have studied total reflection mirror optics with two pairs of elliptical and hyperbolic mirrors, which is called 'Advanced Kirkpatrick-Baez system'. A designed optical system has 200x and 300x magnifications in vertical and horizontal directions. Also diffraction limit size in the optical system is 40 nmx45 nm. We fabricated a pair of elliptical and hyperbolic mirrors for horizontal imaging with a figure accuracy of 2 nm using elastic emission machining (EEM), microstitching interferometry (MSI) and relative-angle-determinable stitching interferometry (RADSI). One-dimensional tests for forming a demagnified image of a slit were carried out at an X-ray energy of 11.5 keV at BL29XUL (EH2) of SPring-8. As a result, a shape beam with a FWHM of 78 nm was observed. This demonstrates that we realized one-dimensional Wolter optics that has a spatial resolution of 78 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Upgrade of far-infrared laser-based Faraday rotation measurement on MST

Recently, the far-infrared (FIR) laser ({lambda}{sub 0}=432 {mu}m) Faraday rotation measurement system on MST has been upgraded. The dc flowing-gas discharge CO{sub 2} pump laser is replaced by a rf-excited, sealed CO{sub 2} laser at 9.27 {mu}m (GEM select 100, Coherent Inc., Santa Clara, CA), which is subdivided equally into three parts to simultaneously pump three FIR cavities. The total infrared pump power is approximately 80 W on the 9R(20) line required to pump the formic acid molecule. Each FIR cavity produces {approx}12 mW, sufficient for 11 simultaneous chord interferometry-polarimetry operations. Three key issues [(1) conservation of circularly polarized wave, (2) colinearity of two probe waves, and (3) stability of intermediate frequencies between lasers] affecting the Faraday rotation measurement have been resolved experimentally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A SURVEY OF STELLAR FAMILIES: MULTIPLICITY OF SOLAR-TYPE STARS

We present the results of a comprehensive assessment of companions to solar-type stars. A sample of 454 stars, including the Sun, was selected from the Hipparcos catalog with {pi}>40 mas, {sigma}{sub {pi}/{pi}} < 0.05, 0.5 {<=} B - V {<=} 1.0 ({approx}F6-K3), and constrained by absolute magnitude and color to exclude evolved stars. These criteria are equivalent to selecting all dwarf and subdwarf stars within 25 pc with V-band flux between 0.1 and 10 times that of the Sun, giving us a physical basis for the term 'solar-type'. New observational aspects of this work include surveys for (1) very close companions with long-baseline interferometry at the Center for High Angular Resolution Astronomy Array, (2) close companions with speckle interferometry, and (3) wide proper-motion companions identified by blinking multi-epoch archival images. In addition, we include the results from extensive radial-velocity monitoring programs and evaluate companion information from various catalogs covering many different techniques. The results presented here include four new common proper-motion companions discovered by blinking archival images. Additionally, the spectroscopic data searched reveal five new stellar companions. Our synthesis of results from many methods and sources results in a thorough evaluation of stellar and brown dwarf companions to nearby Sun-like stars. The overall observed fractions of single, double, triple, and higher-order systems are 56% {+-} 2%, 33% {+-} 2%, 8% {+-} 1%, and 3% {+-} 1%, respectively, counting all confirmed stellar and brown dwarf companions. If all candidate, i.e., unconfirmed, companions identified are found to be real, the percentages would change to 54% {+-} 2%, 34% {+-} 2%, 9% {+-} 2%, and 3% {+-} 1%, respectively. Our completeness analysis indicates that only a few undiscovered companions remain in this well-studied sample, implying that the majority (54% {+-} 2%) of solar-type stars are single, in contrast to the results of prior multiplicity studies. Our sample is large enough to enable a check of the multiplicity dependence on various physical parameters by analyzing appropriate subsamples. Bluer, more massive stars are seen as more likely to have companions than redder, less massive ones, consistent with the trend seen over the entire spectral range. Systems with larger interaction cross sections, i.e., those with more than two components or long orbital periods, are preferentially younger, suggesting that companions may be stripped over time by dynamical interactions. We confirm the planet-metallicity correlation (i.e., higher metallicity stars are more likely to host planets), but are unable to check it for brown dwarfs due to the paucity of such companions, implying that the brown dwarf desert extends over all separation regimes. We find no correlation between stellar companions and metallicity for B - V < 0.625, but among the redder subset, metal-poor stars ([Fe/H] <-0.3) are more likely to have companions with a 2.4{sigma} significance. The orbital-period distribution of companions is unimodal and roughly log normal with a peak and median of about 300 years. The period-eccentricity relation shows the expected circularization for periods below 12 days, caused by tidal forces over the age of the Galaxy, followed by a roughly flat distribution. The mass-ratio distribution shows a preference for like-mass pairs, which occur more frequently in relatively close pairs. The fraction of planet hosts among single, binary, and multiple systems are statistically indistinguishable, suggesting that planets are as likely to form around single stars as they are around components of binary or multiple systems with sufficiently wide separations. This, along with the preference of long orbital periods among stellar systems, increases the space around stars conducive for planet formation, and perhaps life.

79 ASTRONOMY AND ASTROPHYSICS↗

Density characterization of discharged gas-filled capillaries through common-path two-color spectral-domain interferometry

Electrically discharged plasma structures, typically several centimeters in length and sub-millimeter in diameter, have been applied to guide laser pulses in laser plasma accelerators and to focus ion and relativistic electron beams in compact, radially symmetric transport configurations. Knowledge of the on-axis plasma density is critical. Traditional density interferometry has been ineffective for these laser-machined structures, while group velocity delay (GVD) techniques involve combining two laser paths with corresponding alignment complexities and stability sensitivities. Here the GVD technique is advanced to a common-path two-color interferometer configuration performed in the spectral domain of a broad-bandwidth femtosecond laser. Multi-shot tracking of the phase is not required, and the common path assures improved stability. Here, this in situ technique was validated on 15 mm long plasma structures, measuring electron densities of 10 17 -10 18 cm -3 for various fill pressures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unstable and multiple pulsing can be invisible to ultrashort pulse measurement techniques

Here, multiple pulsing occurs in most ultrashort-pulse laser systems when pumped at excessively high powers, and small fluctuations in pump power in certain regimes can cause unusual variations in the temporal separations of sub-pulses. Unfortunately, the ability of modern intensity-and-phase pulse measurement techniques to measure such unstable multi-pulsing has not been studied. Here we report calculations and simulations finding that allowing variations in just the relative phase of a satellite pulse causes the second pulse to completely disappear from a spectral interferometry for direct electric field reconstruction (SPIDER) measurement. We find that, although neither frequency-resolved optical gating (FROG) nor autocorrelation can determine the precise properties of satellite pulses due to the presence of instability, they always succeed in, at least, seeing the satellite pulses. Also, additional post-processing of the measured FROG trace can determine the correct approximate relative height of the satellite pulse and definitively indicate the presence of unstable multiple-pulsing.

42 ENGINEERING↗

Laser Speckle Pattern Stability in Hypersonic Regimes for Experimental Mechanics and Metrological Studies

Here, an empirical study assessing the suitability of laser speckle patterns for use in experimental mechanics research conducted at hypersonic conditions is presented. Speckle patterns generated via coherent optical scattering from a gold-coated graphite surface inserted into a Mach 10 air stream were collected and analyzed using Computer-Aided Speckle Interferometry using two methodologies: a typical spanwise approach involving increasing temporal span between image pairs, and a sequential approach that utilizes a combination of temporal re-referencing and spatial resampling. Results were characterized for spatial-temporal stability and variance. Our observations demonstrate that optical methods relying on stable and properly formed speckle patterns can be used in a hypersonic regime at various Reynolds numbers and common camera frame rates, but the technique is sensitive to the conditions of the airflow and the processing methodology chosen.

42 ENGINEERING↗

Interference of Temporally Distinguishable Photons Using Frequency-Resolved Detection

Here, we demonstrate quantum interference of three photons that are distinguishable in time by resolving them in the conjugate parameter frequency. We show that the multiphoton interference pattern in our setup can be manipulated by tuning the relative delays between the photons, without the need for reconfiguring the optical network. Furthermore, we observe that the symmetries of our optical network and the spectral amplitude of the input photons are manifested in the interference pattern. We also demonstrate time-reversed Hong-Ou-Mandel-like interference in the spectral correlations using time-bin entangled photon pairs. By adding a time-varying dispersion using a phase modulator, our setup can be used to realize dynamically reconfigurable and scalable boson sampling in the time domain as well as frequency-resolved multiboson correlation sampling.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cadmium zinc telluride based infrared interferometry for X-ray detection

Cadmium Zinc Telluride (CZT) is a wide band gap semiconductor for room temperature radiation detection. The electro-optic Pockels effect of the material has been exploited in the past to study electric field non-uniformities and their consequence on conventional detector signals in CZT, by imaging the intensity distribution of infrared (IR) light transmitted through a device placed between crossed polarizers. Recently, quantitative monitoring of extremely high intensity neutron pulses through the change of transmitted IR intensity was demonstrated, offering the advantage to place sensitive electronics outside the measured radiation field. In this work, we demonstrate that X-ray intensity can be deduced directly from measuring the change in phase of 1550 nm laser light transmitted through a 7 × 7 × 2 mm{sup 3} CZT based Pockels cell in a simple Mach Zehnder interferometer. X-rays produced by a 50 kVp Mo X-ray tube incident on the CZT cathode surface placed at 7 mm distance cause a linearly increasing phase shift above 0.3 mA tube current, with 1.58 ± 0.02 rad per mA for an applied bias of 500 V across the 2 mm thick device. Pockels images confirm that the sample properties are in agreement with the literature, exhibiting electric field enhancement near the cathode under irradiation, which may cause the non-linearity at low X-ray tube anode current settings. The laser used to probe the X-ray intensity causes itself some space charge, whose spatial distribution does not seem to be exclusively determined by the incident laser position, i.e., charge carrier generation location, with respect to the electrodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Femtosecond laser optical gas breakdown microplasma: the ionisation and postionisation dynamics

The formation and evolution dynamics of the laser plasma produced in the microvolumes of gases (air, nitrogen, argon, and helium) upon their multiple ionisation by high-intensity (4x10{sup 16} W cm{sup -2}) tightly focused (to a region 1.7 {mu}m in diameter) 400-nm, 100-fs second-harmonic pulses from a Ti:sapphire laser is studied. The spatiotemporal distribution profiles of the refractive index and electron microplasma density were recorded by ultrahigh-speed interferometry. The postionisation of a femtosecond laser plasma, i.e. the growth of the electron density known after the end of the exciting laser pulse, is detected for the first time. A theoretical model is proposed, which describes the mechanism of plasma postionisation by hot photoelectrons. The results of electron density calculations are in good agreement with experimental data. (special issue devoted to the 25th anniversary of the a.m. prokhorov general physics institute)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Strain Field Analysis in Electronic Components by ESPI: Bad Thermal Contact and Damage Evaluation

Designing electronic components and devices is a complex task that must include also considerations about thermo-mechanical behavior of the component itself. This aspect, in fact, can affect the reliability of the device as a consequence of the thermal stresses that are introduced in the component while it is working. Stress concentration can arise, in fact, due to different thermal expansion coefficients of the materials involved. Determining the thermo-mechanical response by numerically methods is not simple and not always possible so that experimental methods are preferable. In this paper, specifically, the electronic speckle pattern interferometry technique was adopted to measure full-field strain of the component during exercise. By using an optical technique it is possible to get information about the behavior of the component without being in contact with the component itself so that the dissipation coefficient is not altered. The system was able to detect gradients of deformation in the component itself connected to the different distribution of internal current in the component. Moreover, it was observed, that the presence of bad thermal contact between the package and the heat sink can be revealed because it results in a different thermos-mechanical behavior of the component. Finally, a critical defect was introduced in the component and it was observed the way the presence of damage affects the in-plane displacement of the component. Very huge differences were observed leading to the consideration that this kind of approach could be conveniently adopted also as a damage detection tool.

42 ENGINEERING↗