Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Prospects for imaging and astrometry on the ground and implications for space interferometry

The potential imaging performance of large telescopes using adaptive optics with laser guide stars, and of interferometers using laser phased subapertures are considered. The potential astrometric performance from the ground is also discussed. For each case the implications for a space interferometry mission are considered. The advantages of the space environment for optical and infrared astronomical interferometry are: transparency at all wavelength bands, no atmospheric turbulence, and the ability to cool optics for observation in the thermal infrared. However, ground based interferometry also has important advantages: the availability of large apertures and long baselines and generally lower costs. While transparency and thermal emission are fundamental, adaptive optics aided by laser guide stars shows promise to eliminate some of the effects of turbulence for ground based imaging. Other techniques such as phase referencing and closure phase can also be used to circumvent some of the effects of atmospheric turbulence. While it is a long step from the theoretical performance predictions for a ground based instrument to their attainment, a future space imaging interferometer must emphasize those capabilities which are impossible or at least very difficult from the ground: UV observations, very high dynamic range measurements, or high resolution measurements of faint, extended objects. The case for space astrometry is more clear: while ground interferometry can offer high accuracies over very small fields, a space interferometer can offer more than two orders of magnitude better performance over wide fields than that achievable with groundbased systems.

Colavita, M. Mark↗

Fiber Optic Temperature Sensor Using Dual Air- Filled Fabry-Pérot Cavities With Variable Pressure

We present an approach for high temperature measurement using a pair of fiber-optic Fabry–Pérot (FP) cavities filled with gas of identical but variable pressure. One of the FPs (reference FP) is placed in the cold zone with a known temperature. The temperature of the measuring FP can be deduced by the spectral fringe shift vs. pressure of the two FPs. This method does not require measurement of the pressure or the knowledge of the optical properties of the gas. The use of gas as the sensing material and the measurement mechanism also implies long-term stability and eliminates the cross-sensitivity to strain. We fabricated the sensors and tested them for measuring temperature up to 800 °C. Here, the sensor shows good linearity in the range. Long-term test conducted at 800 °C exhibited the stability of the sensor with fluctuations of ≤0.3% over a duration exceeding 100 hours.

42 ENGINEERING↗

Novel Diffusivity Measurement Technique

A common-path interferometer (CPI) system was developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. This system uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. Hence, the molecular diffusion coefficient of liquids can be determined using the physical relations between changes in the optical path length and the liquid phase properties. The data obtained with this interferometer were compared with similar results from other techniques and demonstrated that the instrument is superior in measuring the diffusivity of miscible liquids while keeping the system very compact and robust. CPI can also be used for studies in interface dynamics and other diffusion-dominated-process applications.

Rashidnia, Nasser↗

EPR experiment and 2-photon interferometry: Report of a 2-photon interference experiment

After a very brief review of the historical Einstein, Podolsky, and Rosen (EPR) experiments, a new two-photon interference type EPR experiment is reported. A two-photon state was generated by optical parametric down conversion. Pairs of light quanta with degenerate frequency but divergent directions of propagation were sent to two independent Michelson interferometers. First and second order interference effectors were studied. Different than other reports, we observed that the second order interference visibility vanished when the optical path difference of the interferometers were much less than the coherence length of the pumping laser beam. However, we also observed that the second order interference behaved differently depending on whether the interferometers were set at equal or different optical path differences.

Shih, Y. H.↗

Amplitude and intensity spatial interferometry; Proceedings of the Meeting, Tucson, AZ, Feb. 14-16, 1990

Attention is given to such topics as ground interferometers, space interferometers, speckle-based and interferometry-based astronomical observations, adaptive and atmospheric optics, speckle techniques, and instrumentation. Particular papers are presented concerning recent progress on the IR Michelson array; the IOTA interferometer project; a space interferometer concept for the detection of extrasolar earth-like planets; IR speckle imaging at Palomar; optical diameters of stars measured with the Mt. Wilson Mark III interferometer; the IR array camera for interferometry with the cophased Multiple Mirror Telescope; optimization techniques appliesd to the bispectrum of one-dimensional IR astronomical speckle data; and adaptive optical iamging for extended objects.

Breckinridge, Jim B.↗

Estimation of Aperture Errors with Direct Interferometer-Output Feedback for Spacecraft Formation Control

Long-baseline space interferometers involving formation flying of multiple spacecraft hold great promise as future space missions for high-resolution imagery. The major challenge of obtaining high-quality interferometric synthesized images from long-baseline space interferometers is to control these spacecraft and their optics payloads in the specified configuration accurately. In this paper, we describe our effort toward fine control of long-baseline space interferometers without resorting to additional sensing equipment. We present an estimation procedure that effectively extracts relative x/y translational exit pupil aperture deviations from the raw interferometric image with small estimation errors.

Lu, Hui-Ling↗

The Mask Designs for Space Interferometer Mission (SIM)

The Space Interferometer Mission (SIM) consists of three interferometers (science, guide1, and guide2) and two optical paths (metrology and starlight). The system requirements for each interferometer/optical path combination are different and sometimes work against each other. A diffraction model is developed to design and optimize various masks to simultaneously meet the system requirements of three interferometers. In this paper, the details of this diffraction model will be described first. Later, the mask design for each interferometer will be presented to demonstrate the system performance compliance. In the end, a tolerance sensitivity study on the geometrical dimension, shape, and the alignment of these masks will be discussed.

Diffraction↗

High-speed programmable photonic circuits in a cryogenically compatible, visible–near-infrared 200 mm CMOS architecture

Abstract Recent advances in photonic integrated circuits have enabled a new generation of programmable Mach–Zehnder meshes (MZMs) realized by using cascaded Mach–Zehnder interferometers capable of universal linear-optical transformations on N input/output optical modes. MZMs serve critical functions in photonic quantum information processing, quantum-enhanced sensor networks, machine learning and other applications. However, MZM implementations reported to date rely on thermo-optic phase shifters, which limit applications due to slow response times and high power consumption. Here we introduce a large-scale MZM platform made in a 200 mm complementary metal–oxide–semiconductor foundry, which uses aluminium nitride piezo-optomechanical actuators coupled to silicon nitride waveguides, enabling low-loss propagation with phase modulation at greater than 100 MHz in the visible–near-infrared wavelengths. Moreover, the vanishingly low hold-power consumption of the piezo-actuators enables these photonic integrated circuits to operate at cryogenic temperatures, paving the way for a fully integrated device architecture for a range of quantum applications.

47 OTHER INSTRUMENTATION↗

Real-time jitter correction in a photonic analog-to-digital converter

A real-time jitter meter is used to measure and digitally sample the pulse-to-pulse timing error in a laser pulse train. The jitter meter is self-referenced using a single-pulse delay line interferometer and measures timing jitter using optical heterodyne detection between two frequency channels of the pulse train. Jitter sensitivity down to 3×10 -10 fs 2 /Hz at 500 MHz has been demonstrated with a pulse-to-pulse noise floor of 1.6 fs. Furthermore, as a proof of principle, the digital correction of the output of a high-frequency photonic analog-to-digital converter (PADC) is demonstrated with an emulated jitter signal. Up to 23 dB of jitter correction, down to the noise floor of the PADC, is accomplished with radio-frequency modulation up to 40 GHz.

47 OTHER INSTRUMENTATION↗

Single-shot spatiotemporal plasma density measurements with a chirped probe pulse

In this work, we present the development and demonstration of a diagnostic for the measurement of the spatial and temporal evolution of plasma density in a single shot. Single-shot Advanced Plasma Probe HolographIc REconstruction (SAPPHIRE) utilizes a chirped probe pulse, a diffractive optical element, a self-referenced interferometer, and an interference bandpass filter to achieve high-fidelity electron density measurements suitable for underdense plasmas that exhibit cylindrical symmetry. The method overcomes limitations in conventional diagnostics, such as reliance on shot-to-shot reproducibility, while capturing plasma dynamics on picosecond timescales with micron-level spatial resolution. The capabilities of SAPPHIRE are demonstrated through measurements of laser-driven plasma channels in helium–nitrogen gas jets. SAPPHIRE demonstrates the formation and expansion of plasma channels in a single shot and the propagation of supersonic ionization fronts while revealing shot-to-shot variations in the plasma profiles. Experimental results are validated against theoretical models and scaling laws, underscoring the robustness and accuracy of this technique. By enabling ultrafast, high-resolution plasma diagnostics in a single exposure, SAPPHIRE represents a transformative advancement in plasma measurement technology.

Grace, Elizabeth S. [Lawrence Livermore National L↗

Cycle II.5 aircraft aero-optical turbulent boundary-layer/shear-layer measurements

The aero-optical effects associated with propagating a laser beam through aircraft turbulent boundary layers and shear layers were examined. Observed laser optical performance levels were compared with those inferred from aerodynamic measurements of unsteady densities and correlation lengths within these random flows. Optical instrumentation included a fast shearing interferometer (FSI). A 9 cm diameter collimated helium neon laser beam made a double pass through the aircraft random flow via an airfoil mirror located one meter from the fuselage. Typical aircraft turbulent boundary layer thickness measured 0.3 meters. Averaging many FSI generated modulation transfer functions (MTFs) and Fourier transforming, this average yields the expected far field intensity degradation associated with an aircraft mounted laser system. Aerodynamic instrumentation included fine wire probes to measure unsteady temperature and mass flux. A laser doppler velocimeter measured unsteady velocity within the flows. An analysis of these data yielded point measurements of unsteady density and correlation length.

Gilbert, K.↗

Interferometer Measures Broardband Surface Acoustic Waves

Dual differential interferometer uses two pairs of orthogonallypolarized optical beams to measure amplitude and orientation of broadband ultrasonic surface acoustic waves. Instrument modular, and sensitivity limited only by optical detector used.

Claus, R. O.↗

Investigation of thermospheric winds relative to space station orbital altitudes

An investigation of thermospheric winds, relative to the space station orbital altitudes, was made in order to provide information that is useful in an environmental disturbance assessment. Current plans are for this low Earth orbiting facility to orbit at an inclination of 28.5 deg. The orbital altitudes were not yet defined due to the evolutionary configuration of the Space Station. The upper and lower bounds of the orbital altitudes will be based on constraints set by the drag and expected orbital decay and delivery altitude capability of the Shuttle. The orbital altitude will be estimated on the order of 500 km. Neutral winds in the region from about 80 to 600 km which were derived from satellite drag data, Fabry-Perot interferometers, sounding rockets, ground-based optical Doppler techniques, incoherent scatter radar measurements from Millstone Hill combined with the mass spectrometer and lithium trail neutral wind measurements are examined. The equations of motion of the low Earth orbiting facility are also discussed.

Susko, M.↗

High spectral resolution lidar to measure optical scattering properties of atmospheric aerosols. II - Calibration and data analysis

The high spectral resolution lidar (HSRL) measures optical properties of atmospheric aerosols by interferometically separating the elastic aerosol backscatter from the Doppler broadened molecular contribution. Calibration and data analysis procedures developed for the HSRL are described. Data obtained during flight evaluation testing of the HSRL system are presented with estimates of uncertainties due to instrument calibration. HSRL measurements of the aerosol scattering cross section are compared with in situ integrating nephelometer measurements.

Sroga, J. T.↗

Improved Skin Friction Interferometer

An improved system for measuring aerodynamic skin friction which uses a dual-laser-beam oil-film interferometer was developed. Improvements in the optical hardware provided equal signal characteristics for each beam and reduced the cost and complexity of the system by replacing polarization rotation by a mirrored prism for separation of the two signals. An automated, objective, data-reduction procedure was implemented to eliminate tedious manual manipulation of the interferometry data records. The present system was intended for use in two-dimensional, incompressible flows over a smooth, level surface without pressure gradient, but the improvements discussed are not limited to this application.

Westphal, R. V.↗

On the role of convective motion during dendrite growth: Experiments under variable gravity, revised

Experiments show the effect of self induced convection on individual dendrite growth in uniformly supercooled samples and solidification of the resulting mush under conditions of high and low g. Convection is visualized by a Schlieren optical system or a Mach Zender interferometer. For ice crystals growing from the vapor in air, a slight reduction in linear growth rate occur under low g. For ice crystals growing from NaCl solution, dendrite tip velocities are unchanged, but subsequent mush solidification is enhanced through drainage channels under higher g. By contrast, sodium sulfate decahydrate dendrites growing from solution produce convective plumes which lead to higher tip growth rate only as the crystal growth direction approaches that of gravity. Convective plumes are laminar for small crystals under conditions of these experiments; the rise velocity of such plumes is greater than individual vortex rings under identical conditions. Convection effects are only present in solution under a critical supercooling less than about 5 C for sodium sulfate and 2 C for ice in NaCl since at higher supercooling the crystallization velocity, proportional to the square of the supercooling, exceeds the convective velocity, proportional to the square root of the supercooling. The role of convective velocity in bulk solidification is to give a large scale flow which under extreme cases may lead to extensive secondary crystal production, which alters the resulting crystal texture of the completely solidified melt.

Hallett, J.↗

Compact in-line laser radial shear interferometer

A compact in-line radial shearing interferometer using laser as a light source is presented. The interferometer is made out of a cube-type beam splitter so that the two opposite surfaces are generated with different curvatures while the normal to the entrance and exit surfaces are in the same line. The interferometer is simple to make and easy to align. Aberration analysis of the interferometer is also presented. Some applications of the interferometer for testing lenses and infrared optical systems and for accessing the quality of an emerging wave front from the exit slit of a monochromator are suggested.

Shukla, R. P.↗

Optical design and testing of a fast, large aperture, infrared space telescope

An optical design study for a next generation infrared space telescope has been performed. The concept is that of a passively cooled telescope of minimum aperture 2.5 m with an F/1.2 primary and wavelength coverage from 2 to as least 40 microns, and possibly to 100 microns. Compactness, low thermal emission from the optics and structure, diffraction limited imaging at 2 microns, and sensitivity to misalignment aberrations and manufacturing errors were the main considerations for this study. Ray tracing results are presented showing the characteristics of the various designs considered. A preliminary investigation of stray light properties is also given. Special emphasis has been placed on the testing of such a fast primary, and optical systems using a lateral shearing interferometer are described for testing both the primary and the primary/secondary combination.

Humphries, C. M.↗