Characterization of radiation damage effects in high-energy neutrino target graphite using low-energy ions

Exposure of graphite targets to high intensity proton beams at neutrino production facilities causes changes in the target material that can result in a shortened operation lifetime. The dominant factors in this process are currently thought to be mechanical in nature resulting primarily from microstructural effects that lead to thermal and structural changes in bulk material properties. As currently planned beam facilities with increased proton energy and intensity begin to come online it will be important to thoroughly understand these processes, and ideally to be able to predict the effects of new beam designs on target properties. Direct analysis of targets exposed to existing high-energy proton beams is complicated by several factors, such as very limited access to proton beam facilities, high associated costs, irradiation times on the order of months, and the resulting radioactivity of irradiated samples that requires special facilities for post-irradiation examination. Much of the existing literature concerning irradiation damage in graphite has been focused on the needs of the nuclear engineering community, however high-energy proton targets operate in a much different environment. In comparison to graphite irradiated in a nuclear reactor, graphite used in proton beam targets receives a higher dose rate, have greater gas production, and experience short irradiation pulses as opposed to continuous irradiation. Low-energy ion irradiation offers a method of inducing similar levels of radiation damage to high-energy protons while avoiding many of the difficulties and limitations associated with high-energy proton beams and the corresponding activated specimen testing. My research described in this thesis focused on investigating how low-energy ion irradiation could be used to induce the same or similar types of microstructural alteration and mechanical property degradation as that seen in high-energy neutrino production target graphites by varying damage le vels and irradiation temperatures prior to post-irradiation characterisation.

43 PARTICLE ACCELERATORS↗

R and D on Proton Extinction Monitor for COMET Project

The COMET experiment searches for a muon to electron conversion process that is one of the lepton flavor violation processes. We use an 8-GeV pulsed proton beam. The proton extinction ratio is an important parameter. In order to measure this ratio pulse-by-pulse, we are developing a monitoring device. This device is called Proton Extinction Monitor and is a gas Cerenkov detector with gating photomultiplier tubes(PMT). The result of the investigation is that ethane is a promising gas for the Cerenkov radiator gas. A gating PMT is under development. We fabricated a divider circuit which switches at 10-kHz and has a cutoff ratio of 10{sup -6}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic Signatures of Phonon Character in Molecular Electron Spin Relaxation

Spin–lattice relaxation constitutes a key challenge for the development of quantum technologies, as it destroys superpositions in molecular quantum bits (qubits) and magnetic memory in single molecule magnets (SMMs). Gaining mechanistic insight into the spin relaxation process has proven challenging owing to a lack of spectroscopic observables and contradictions among theoretical models. Here, we use pulse electron paramagnetic resonance (EPR) to profile changes in spin relaxation rates (T 1 ) as a function of both temperature and magnetic field orientation, forming a two-dimensional data matrix. For randomly oriented powder samples, spin relaxation anisotropy changes dramatically with temperature, delineating multiple regimes of relaxation processes for each Cu(II) molecule studied. We show that traditional T 1 fitting approaches cannot reliably extract this information. Single-crystal T 1 anisotropy experiments reveal a surprising change in spin relaxation symmetry between these two regimes. We interpret this switch through the concept of a spin relaxation tensor, enabling discrimination between delocalized lattice phonons and localized molecular vibrations in the two relaxation regimes. Variable-temperature T 1 anisotropy thus provides a unique spectroscopic method to interrogate the character of nuclear motions causing spin relaxation and the loss of quantum information.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved fission neutron energy discrimination with 4 He detectors through pulse filtering

Our paper presents experimental and computational techniques implemented for 4 He gas scintillation detectorsfor inducedfission neutron detection. Fission neutrons are produced when natural uranium samples are activelyinterrogated by 2.45 MeV deuterium-deuterium fusion reaction neutrons. Fission neutrons of energies greaterthan 2.45 MeV can be distinguished by their different scintillation pulse height spectra since 4 He detectorsretain incident fast neutron energy information. To enable the preferential detection of fast neutrons up to10 MeV and suppress low-energy event counts, the detector photomultiplier gain is lowered and triggerthreshold is increased. Pile-up and other unreliable events due to the interrogating neutronflux and backgroundradiation arefiltered out prior to the evaluation of pulse height spectra. With these problem-specific calibrationsand data processing, the 4 He detector's accuracy at discriminatingfission neutrons up to 10 MeV is improvedand verified with 252 Cf spontaneousfission neutrons. Given the 4 He detector's ability to differentiate fastneutron sources, this proof-of-concept active-interrogation measurement demonstrates the potential of specialnuclear materials detection using a 4 He fast neutron detection system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Variance Investigation and Scintillation Mechanisms of Cs 2 LiLaBr 6-x Cl x :Ce (CLLBC) and Cs 2 LiYBr 6 :Ce (CLYB)

We perform an investigation into the scintillation processes and performance of elpasolites Cs 2 LiLaBr 6-x Cl x :Ce (CLLBC) and Cs 2 LiYBr 6 :Ce (CLYB) using a thermal cycle over a range of -20 to +50º C. At 10º increments, we acquire data with both a waveform digitizer and charge-integrating electronics. We identify decay components and evaluate decay times, thermal neutron gamma-equivalent energy (GEE), and pulse shape discrimination (PSD) performance. Results are compared to common Cs 2 LiYCl 6 :Ce (CLYC).

36 MATERIALS SCIENCE↗

High-Purity Germanium Spectroscopy at Rates in Excess of 10^{6} Events/s

Abstract—In gamma spectroscopy, a compromise must be made between energy resolution and event-rate capability. Some foreseen nuclear material safeguards applications require a spectrometer with energy resolution typical of high purity germanium (HPGe) detectors, operated at rates up to and exceeding 106 events per second. We report the performance of an HPGe spectrometer adapted to run at such rates. Our system consists of a commercial semi-coaxial HPGe detector, a modified high-voltagerail, resistive-feedback, charge-sensitive preamplifier and a continuous waveform digitizer. Digitized waveforms are analyzed offline with a novel time-variant trapezoidal filter algorithm. Several time-invariant trapezoidal filters are run in parallel and the slowest one not rejected by instantaneous pileup conditions is used to measure each pulse height. We have attained full-widthat- half-maximum energy resolution of less than 8 keV measured at 662 keV with 1:08*106 per second incoming event rate and 38% throughput. An additional constraint on the width of the fast trigger filter removes a significant amount of edge pileup that passes the first pileup cut, reducing throughput to 26%. While better resolution has been reported by other authors, our throughput is over an order of magnitude higher than any other reported HPGe system operated at such an event rate.

germanium, semiconductor radiation detectors, gamm↗

Open Radiation Monitoring: Histogram Builder Module Design

The Open Radiation Monitoring Project seeks to develop and demonstrate a modular radiation detection architecture designed specifically for use in arms control treaty verification (ACTV) applications that will facilitate rapid development of trusted systems to meet the needs of potential future treaties. A modular architecture can be used to reduce more complex systems to a series of single purpose building blocks, thereby facilitating equipment inspection and in turn building trust in the equipment by all treaty parties. Furthermore, a modular architecture can be used to control data flow within the measurement system, reducing the risk of "hidden switches" and constraining the amount of sensitive information that could potentially be inadvertently leaked. This report details the first revision of a prototype circuit that will convert analog pulses directly into a histogrammed data set for further processing. The circuit was designed with both spectroscopy and multiplicity analysis in mind but can, in principle, be used to reduce any raw data stream into a histogram. The number of output channels is limited, and the histogram bin ranges are user configurable to allow for non-uniform and discontinuous bins, which makes it possible to restrict the information being passed down stream if desired. Pulse processing relies entirely on analog circuitry and non- programmable logic, which enables operation without the need for a central processor or other programmable control unit. The circuit remains untested under the Open Radiation Monitoring project due to the closure of the sponsoring program. However, further development and testing is scheduled to take place in support of a purpose-built trusted verification system development effort known as COGNIZANT, which demonstrates the potential benefit of developing a suite of modular trusted system components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of pre-existing disorder on radiation defect dynamics in Si

The effect of pre-existing lattice defects on radiation defect dynamics in solids remains unexplored. Here, we use a pulsed beam method to measure the time constant of defect relaxation for 500 keV Ar ion bombardment of Si at 100 °C with the following two representative types of pre- existing lattice disorder: (i) point defect clusters and (ii) so-called “clamshell” defects consisting of a high density of dislocations. Results show that point defect clusters slow down defect relaxation processes, while regions with dislocations exhibit faster defect interaction dynamics. These experimental observations demonstrate that the dynamic aspects of damage buildup, attributed to defect trapping-detrapping processes, can be controlled by defect engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Active-Interrogation Measurements of Induced-Fission Neutrons from Low-Enriched Uranium

Protection and control of nuclear fuels is paramount for nuclear security and safeguards; therefore, it is important to develop fast and robust controlling mechanisms to ensure the safety of nuclear fuels. Through both passive- and active-interrogation methods we can use fast-neutron detection to perform real-time measurements of fission neutrons for process monitoring. Active interrogation allows us to use different ranges of incident neutron energy to probe for different isotopes of uranium. With fast-neutron detectors, such as organic liquid scintillation detectors, we can detect the induced-fission neutrons and photons and work towards quantifying a sample’s mass and enrichment. Using MCNPX-PoliMi, a system was designed to measure induced-fission neutrons from U-235 and U-238. Measurements were then performed in the summer of 2010 at the Joint Research Centre in Ispra, Italy. Fissions were induced with an associated particle D-T generator and an isotopic Am-Li source. The fission neutrons, as well as neutrons from (n, 2n) and (n, 3n) reactions, were measured with five 5” by 5” EJ-309 organic liquid scintillators. The D-T neutron generator was available as part of a measurement campaign in place by Padova University. The measurement and data-acquisition systems were developed at the University of Michigan utilizing a CAEN V1720 digitizer and pulse-shape discrimination algorithms to differentiate neutron and photon detections. Low-enriched uranium samples of varying mass and enrichment were interrogated. Acquired time-of-flight curves and cross-correlation curves are currently analyzed to draw relationships between detected neutrons and sample mass and enrichment. In the full paper, the promise of active-interrogation measurements and fast-neutron detection will be assessed through the example of this proof-of-concept measurement campaign. Additionally, MCNPX-PoliMi simulation results will be compared to the measured data to validate the MCNPX-PoliMi code when used for active-interrogation simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation results for a low energy nuclear recoil yields measurement in liquid xenon using the MiX detector

Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary to increase the sensitivity of liquid xenon experiments to light dark matter. Neutron capture on xenon can be used to produce nuclear recoil events with energies below 0.3 keV NR via the asymmetric emission of γ rays during nuclear de-excitation. The feasibility of an ultra-low energy nuclear recoil measurement using neutron capture was investigated for the Michigan Xenon (MiX) detector, a small dual-phase xenon time projection chamber that is optimized for a high scintillation gain. Simulations of the MiX detector, a partial neutron moderator, and a pulsed neutron generator indicate that a population of neutron capture events can be isolated from neutron scattering events. Additionally, the rate of neutron captures in the MiX detector was optimized by varying the thickness of the partial neutron moderator, neutron pulse width, and neutron pulse frequency.

detector calibration↗

Measurment and energy correction due to charge carrier lifetimes in large HPGe spectrometers

This work addresses the energy spectrum correction due to increased charge carrier collection times in larger HPGe spectrometers. The energy of the radiation interaction is expected to be proportional to the total collected charge. This is increasingly not true with larger HPGe spectrometers. Some charge is lost as the total charge travels from the interaction location to the collection electrode. This path dependent loss of charge results in decreased energy resolution. In HPGe spectrometers, this process is characterized by the charge carrier lifetime constant and is given as an exponential function of the charge carrier collection time divided by this constant. Thus large detectors can experience exponential decrease in energy resolution as charge carrier collection time increases. We study the effect of charge carrier lifetime on energy resolution for a large diameter p-type coaxial and p-type point contact HPGe spectrometers using pulse shape analysis. We present a method to measure the charge carrier lifetime for a given HPGe spectrometer.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Coincident Capture through Post-processing PTRAC [Slides]

This presentation discusses the new PTRAC capabilities and workflows. The PTRAC capability in MCNP6.3 has seen a massive overhaul since MCNP6.2. The new HDF5 file format allows for both MPI- and thread-based parallelism. MCNPTools has been updated to handle the new HDF5 PTRAC format and is now open sourced on GitHub. Built-in capabilities, such as the pulse-height tally coincident capture special treatment, can largely be replicated through separate postprocessing scripts that leverage both PTRAC and MCNPTools. This allows for greater flexibility in user-specified and controlled detector response functionality, ultimately using the MCNP code for what it is best at (i.e., particle transport).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Phonon Sensor Dynamics for Cryogenic Dark Matter Search Experiment

Understanding the quasiparticle diffusion process inside sputtered aluminum (Al thin films (∼ 0.1-1 μm is critical for the Cryogenic Dark Matter Search (CDMS experiment to further optimize its detectors to directly search for dark matter. An initial study with Al films was undertaken by our group ∼ 20 years ago, but some important questions were not answered at the time. This thesis can be considered a continuation of that critical study. The CDMS experiment utilizes high purity silicon and germanium crystals to simultaneously measure ionization and phonons created by particle interactions. In addition to describing some of the rich physics involved in simultaneously detecting ionization and phonons with a CDMS detector, this thesis focuses on the detailed physics of the phonon sensors themselves, which are patterned onto CDMS detector surfaces. CDMS detectors use thin sputtered Al films to collect phonon energy when it propagates to the surfaces of the detector crystals. The phonon energy breaks Cooper pairs and creates quasiparticles (qps). These qps diffuse until they get trapped in an proximitized “overlap” region where lower-Tc tungsten films connect to the Al film. These tungsten films are the transition edge sensors (W-TESs CDMS uses to readout phonon signals. We performed a wide range of experiments using several sets of test devices designed and fabricated specifically for this work. The devices were used mostly to study quasiparticle (qp transport in Al films and qp transmission through Al/W interfaces. The results of this work are being used to optimize the design of detectors for SuperCDMS SNOLAB. This thesis is intended for CDMS collaborators who are interested in knowing more about the detailed fundamentals of how our phonon sensors work so they can take full advantage of their benefits. However, this work can also be read by general readers who are interested in particle detection using TES technology. This thesis contains eight chapters. The first chapter gives basic background information about dark matter and searches for it. We then describe the basic CDMS detector technology in Chapter two. Chapter three focuses on superconductivity and explains some of the solid state physic most relevant to our Al and W film studies. We then turn our attention to the fabrication processes used to make test devices, and describe some of the studies done to characterize our W and Al film properties. Chapter five explains the experimental setup including how a 3He/4He dilution refrigerator works, and how our electronics were configured. We then get to chapter six where we present key experimental results. Chapter seven covers the TES model we used for our test devices to simulate the data pulse shapes and reconstruct the pulse energies. We also describe the diffusion models used to fit our data. Finally, we end with a short summary of our findings and provide a few suggestions for future studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an active detector for the characterization of the late-time radiation environment from a reactor pulse

Document available in abstract form only, full text of document follows: This paper discusses the use of a commercially available {sup 235}U fission chamber, with a matching compensating ion chamber, originally sold as a single-ended detector with the signal conducted over the shield of a coaxial cable. The authors designed an aluminum housing that isolates the two detectors and converts the signals to full differential mode as a noise-reduction technique. The signals are processed using the switched resistor technique to extend the signal range to longer times from the peak of the pulse [Luker, S. M., Griffin, P. J., King, D. B., and Suo-Anttila, A. J., 'Improved Diagnostics for Analysis of a Reactor Pulse Radiation Environment,' 13. International Symposium on Reactor Dosimetry, Akersloot, Netherlands, May 25, 2008, pp. 4-6.]. The newly configured fission chamber assembly has been used at the annular core research reactor at Sandia National Laboratories to provide a high-fidelity characterization of the neutron time profile from a pulsed operation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast neutron-gamma discrimination on neutron emission profile measurement on JT-60U

A digital signal processing (DSP) system is applied to stilbene scintillation detectors of the multichannel neutron emission profile monitor in JT-60U. Automatic analysis of the neutron-{gamma} pulse shape discrimination is a key issue to diminish the processing time in the DSP system, and it has been applied using the two-dimensional (2D) map. Linear discriminant function is used to determine the dividing line between neutron events and {gamma}-ray events on a 2D map. In order to verify the validity of the dividing line determination, the pulse shape discrimination quality is evaluated. As a result, the {gamma}-ray contamination in most of the beam heating phase was negligible compared with the statistical error with 10 ms time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A front-end readout Detector Board for the OpenPET electronics system

Here, we present a 16-channel front-end readout board for the OpenPET electronics system. A major task in developing a nuclear medical imaging system, such as a positron emission computed tomograph (PET) or a single-photon emission computed tomograph (SPECT), is the electronics system. While there are a wide variety of detector and camera design concepts, the relatively simple nature of the acquired data allows for a common set of electronics requirements that can be met by a flexible, scalable, and high-performance OpenPET electronics system. The analog signals from the different types of detectors used in medical imaging share similar characteristics, which allows for a common analog signal processing. The OpenPET electronics processes the analog signals with Detector Boards. Here we report on the development of a 16-channel Detector Board. Each signal is digitized by a continuously sampled analog-to-digital converter (ADC), which is processed by a field programmable gate array (FPGA) to extract pulse height information. A leading edge discriminator creates a timing edge that is "time stamped" by a time-to-digital converter (TDC) implemented inside the FPGA. In conclusion, this digital information from each channel is sent to an FPGA that services 16 analog channels, and then information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc.

47 OTHER INSTRUMENTATION↗

Radiation-Induced Plutonium Redox Chemistry

Plutonium plays a key role in global actinide research and nuclear fuel cycle technologies, and yet, our fundamental understanding of its inherent radiation-induced chemical behavior is limited. These radiation-induced processes cannot simply be switched off, as they are as fundamentally inherent to plutonium as the impact of relativistic effects on its f-electrons. In less chemically complex actinide systems, such as aqueous solutions of neptunium and americium, , radiolysis products play a significant role in the redox cycling of their oxidation states. However, plutonium's multiple, coexisting, and chemically active oxidation states, which comprise of bare ions and dioxo cations, provide additional redox pathways that complicate radiation-induced processes. Oxidation state control is critical for the manipulation of plutonium, especially in used nuclear fuel reprocessing technologies, where oxidation specific states are successfully extracted, and others rejected. Consequently, mechanistically understanding the behavior of plutonium’s multiple oxidation states in the presence of intense ionizing radiation fields is essential for predicting the behavior of this element under multiple conditions that support the development and innovation of nuclear fuel cycle technologies. Here, we present recent advances in our understanding of plutonium radiation chemistry, including the first-ever multiscale model for predicting gamma radiation-induced plutonium redox chemistry, and new chemical kinetics for the reaction of plutonium and its complexes of tributyl phosphate (TBP), N,N-di-(2-ethylhexyl)butyramide (DEHBA), and N,N-di-(2-ethylhexyl)isobutyramide (DEHiBA) with transients radiolysis products, a measured using electron pulse radiolysis.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗