Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “modules”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Multiscale Characterization of Photovoltaic Modules—Case Studies of Contact and Interconnect Degradation

The current popularity of photovoltaic (PV) systems is due in large part to their exceptional reliability and significantly lower cost than other energy sources. Studying cell and module degradation is key to promote further development in the state of the art. Fielded or accelerated aged modules exhibit different failure modes, of which metallization degradation (contacts and interconnections) is prevalent. In this work, we discuss how multiscale characterization methods can be applied to a variety of module technologies that have been field exposed and have undergone accelerated age testing. These methods include performing characterization on the module level, cell level, and finally the materials level. The observed performance losses from the module- and cell-level characterization can be correlated with materials properties to find out the root cause of degradation. We recommend an initial nondestructive characterization suite, including module- and cell-level current-voltage ( I--V ), Suns-V OC , photoluminescence and electroluminescence imaging, quantum efficiency, ultraviolet fluorescence imaging, and thermal infrared imaging. Samples are then extracted from particularly degraded regions of the module and prepared for materials characterization techniques, such as top-down and cross-sectional scanning electron microscopy, energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, secondary ion mass spectrometry, Raman spectroscopy, and transmission electron microscopy, allowing a deeper look into the mechanism behind the metallization degradation. This article serves as an instructional review to introduce the different multiscale characterization methods and how they can be effectively applied to perform PV degradation studies. Furthermore, we also share some of our examples and discuss the strengths, limitations, and best practices for each of the characterization techniques.

14 SOLAR ENERGY↗

Evaluation of Maxim Module-Integrated Electronics at the DOE Regional Test Centers: Preprint

Module-embedded power electronics developed by Maxim Integrated are under evaluation through a partnership with the Department of Energy's Regional Test Center (RTC) program. Field deployments of both conventional modules and electronics-enhanced modules are designed to quantify the performance advantage of Maxim's products under different amounts of inter-row shading, and their ability to be deployed at a greater ground-coverage-ratio than conventional modules. Simulations in PVSYST have quantified the predicted performance difference between conventional modules and Maxim's modules from inter-row shading. Initial performance results have identified diffuse irradiance losses at tighter row spacing for both the Maxim and conventional modules. Comparisons with published models show good agreement with models predicting the greatest diffuse irradiance losses. At tighter row spacing, all of the strings equipped with embedded power electronics outperformed their conventional peers. An even greater performance advantage is predicted to occur in the winter months when the amount of inter-row shading mismatch is at a maximum.

14 SOLAR ENERGY↗

PV Lifetime Project: Measuring PV Module Performance Degradation: 2018 Indoor Flash Testing Results

Photovoltaic (PV) module and system performance degradation is being measured by periodic flash testing of fielded PV modules at three sites. As of early 2018, results from modules fielded in New Mexico and Colorado are now available. These data indicate that module degradation varies significantly between module types and can also vary between modules of the same model. In addition, degradation rates for some module types appear to vary over time. Great care is made to control for stability and repeatability in the measurements over time, but there is still a +/-0.5% uncertainty in flash test stability. Therefore, it will take several more years for degradation rate results to be known with higher confidence.

14 SOLAR ENERGY↗

Field Study of Nighttime Leakage Currents in Bifacial PV Modules: Correlation with Atmospheric Electric Field Data

Leakage currents measured on PV modules in the field originate from a potential difference between the modules' frame and the cells. They can be a relative indicator of Potential-Induced Degradation (PID) severity, especially when comparing the same module design in a different environment. As modules are not operating at night, no leakage current should be observed but our team has reported several events of nighttime leakage currents on bifacial PV modules. These events have been firstly observed during a thunderstorm that are characterized by strong atmospheric electrical field values. This lead us to believe that nighttime leakage currents could originate from the atmospheric electric charges. In this paper, we correlate nighttime leakage currents measured on bifacial PV modules with field mill data to identify the origin of nighttime leakage currents. Our results show that so far, no leakage currents at night occur when the atmospheric electric field is between 0 and 150–200 V/m (standard value for fair weather). As soon as the atmospheric electric field is out of this range, leakage currents are observed with or without rain involved. This suggests a transport of charged particles from the atmosphere to the modules' frame. A combination of heavy rain with strong atmospheric electric field results into high nighttime leakage currents with a magnitude up to 8 times higher than what observed during the day with -1500V applied. This is explained by an easier transport of the charged particles through the water droplets. Based on these results, leakage currents observed during the day might not be only due to the inherent potential difference between the frame and the cells depending on the atmospheric electric field activity. We believe that it should be taken into account in PID studies.

14 SOLAR ENERGY↗

A Hybrid Modulation Method for Single-Stage Soft-Switching Inverter Based on Series Resonant Converter

Pseudo-dc-link inverters are promising due to the single-stage configuration. The inverters can be isolated by high-frequency transformers, which also provide the freedom of step-up/down through winding turns ratio. Conventionally, a pseudo-dc-link inverter is based upon a pulsewidth modulation converter like flyback converter, but the accompanying switching losses can degrade efficiency and overall system performance. Alternatively, resonant converters (e.g., series resonant converter) seem to fit the need as they typically display soft-switching characteristics. However, the relevant research results are scarce because of two main reasons: high resonant current and limited soft-switching range. To overcome the difficulties, a hybrid modulation method is proposed in this article for a pseudo-dc-link inverter based on series resonant converter. In high-line region, the inverter operates with variable-frequency modulation, which leads to zero-voltage switching and relatively low-resonant current. In low-line region, the inverter operates with a short-pulse density modulation so that switching losses are greatly curtailed without excessive resonant current. The merits in both regions together contribute toward the high efficiency of the inverter. This article presents the operational principle of the proposed modulation as well as a comparison with other modulation methods. In addition, a 400 V-230 Vac, 2-kW prototype was built to verify the proposed modulation and the peak efficiency reaches 98.0%.

42 ENGINEERING↗

SU-E-T-309: Tangential Modulated Arc Therapy: A Novel Technique for the Treatment of Superficial Disease

Purpose: We propose a new type of treatment that employs a modulated and sliding tangential photon field to provide superior coverage of superficial targets when compared to other commonly employed methods while drastically reducing dose to the underlying sensitive structures often present in these cases. Methods: Modulated treatment plans were formulated for a set of three representative cases. The first was a revised treatment of a scalp sarcoma, while the second was a treatment of a right posterior chest wall sarcoma. For these cases, asymmetric jaw placement, angular limitations, and central isocenter placements were used to force the optimization algorithm into finding solutions with beamlines that were not perpendicular to the body surface. The final case targeted the chest wall of a breast cancer patient, in which standard treatments were compared to the use of modulated fields with multiple isocenters along the chest wall. Results: When compared with unrestricted modulated arcs, the tangential arc scalp treatment reduced the max and mean doses delivered to the brain by 33Gy (from 55 to 22Gy) and 6Gy (from 14Gy to 8Gy), respectively. In the right posterior chest wall case, the V10 in the ipsilateral lung was kept below 5% while retaining a Rx dose (45Gy) target coverage of over 97%. For the breast case, the modulated plan achieved reductions in high dose to the ipsilateral lung and heart by a factor of 2–3 when compared to classic laterally opposed tangents and reduced the V5 by 40% when compared to standard modulated arcs. Conclusion: Tangential modulated arc therapy has outperformed the conventional modalities of treatment for superficial lesions used in our clinic. We hope that with the advent of digitally controlled linear accelerators, we can uncover further benefits of this new technique and extend its applicability to a wider section of the patient population.

60 APPLIED LIFE SCIENCES↗

Characterization of Chemically Induced Liver Injuries Using Gene Co-Expression Modules

Liver injuries due to ingestion or exposure to chemicals and industrial toxicants pose a serious health risk that may be hard to assess due to a lack of non-invasive diagnostic tests. Mapping chemical injuries to organ-specific damage and clinical outcomes via biomarkers or biomarker panels will provide the foundation for highly specific and robust diagnostic tests. Here, we have used DrugMatrix, a toxicogenomics database containing organ-specific gene expression data matched to dose-dependent chemical exposures and adverse clinical pathology assessments in Sprague Dawley rats, to identify groups of co-expressed genes (modules) specific to injury endpoints in the liver. We identified 78 such gene co-expression modules associated with 25 diverse injury endpoints categorized from clinical pathology, organ weight changes, and histopathology. Using gene expression data associated with an injury condition, we showed that these modules exhibited different patterns of activation characteristic of each injury. We further showed that specific module genes mapped to 1) known biochemical pathways associated with liver injuries and 2) clinically used diagnostic tests for liver fibrosis. As such, the gene modules have characteristics of both generalized and specific toxic response pathways. Using these results, we proposed three gene signature sets characteristic of liver fibrosis, steatosis, and general liver injury based on genes from the co-expression modules. Out of all 92 identified genes, 18 (20%) genes have well-documented relationships with liver disease, whereas the rest are novel and have not previously been associated with liver disease. In conclusion, identifying gene co-expression modules associated with chemically induced liver injuries aids in generating testable hypotheses and has the potential to identify putative biomarkers of adverse health effects.

59 BASIC BIOLOGICAL SCIENCES↗

Preliminary Thermal Modeling of HI-STORM 100 Storage Modules at Diablo Canyon Power Plant ISFSI

Thermal analysis is being undertaken at Pacific Northwest National Laboratory (PNNL) in support of inspections of selected storage modules at various locations around the United States, as part of the Used Fuel Disposition Campaign of the U.S. Department of Energy, Office of Nuclear Energy (DOE-NE) Fuel Cycle Research and Development. This report documents pre-inspection predictions of temperatures for two modules at the Diablo Canyon Power Plant ISFSI identified as candidates for inspection. These are HI-STORM 100 modules of a site-specific design for storing PWR 17x17 fuel in MPC-32 canisters. The temperature predictions reported in this document were obtained with detailed COBRA-SFS models of these storage systems, with the following boundary conditions and assumptions. • storage module overpack configuration based on FSAR documentation of HI-STORM100S-218, Version B; due to unavailability of site-specific design data for Diablo Canyon ISFSI modules • Individual assembly and total decay heat loadings for each canister, based on at-loading values provided by PG&E, “aged” to time of inspection using ORIGEN modeling - Special Note: there is an inherent conservatism of unquantified magnitude – informally estimated as up to approximately 20% -- in the utility-supplied values for at-loading assembly decay heat values • Axial decay heat distributions based on a bounding generic profile for PWR fuel. • Axial location of beginning of fuel assumed same as WE 17x17 OFA fuel, due to unavailability of specific data for WE17x17 STD and WE 17x17 Vantage 5 fuel designs • Ambient conditions of still air at 50°F (10°C) assumed for base-case evaluations - Wind conditions at the Diablo Canyon site are unquantified, due to unavailability of site meteorological data - additional still-air evaluations performed at 70°F (21°C), 60°F (16°C), and 40°F (4°C), to cover a range of possible conditions at the time of the inspection. (Calculations were also performed at 80°F (27°C), for comparison with design basis assumptions.) All calculations are for steady-state conditions, on the assumption that the surfaces of the module that are accessible for temperature measurements during the inspection will tend to follow ambient temperature changes relatively closely. Comparisons to the results of the inspections, and post-inspection evaluations of temperature measurements obtained in the specific modules, will be documented in a separate follow-on report, to be issued in a timely manner after the inspection has been performed.

Site Inspection↗

Life Cycle Inventory of Current Photovoltaic Module Recycling Processes in Europe

Solar photovoltaic (PV) installations must be properly dismantled and any waste treated and disposed at the end of project life. However, because most of the world's nearly 400 GW of PV systems have been built in the past decade - each expected to operate for between 20 and 30 years - current PV module waste volumes do not yet justify widespread operation of PV recycling facilities. The necessary policies and technologies for recycling PV systems are currently under rapid development. With modifications to the European waste electrical and electronic equipment directive (WEEE 2012/19/EU) in 2012, take back and recycling of PV modules is, in fact, already mandatory in Europe. There, take back and recycling is currently performed in small but annually-increasing quantities. Even though waste treatment is considered part of a module's life cycle, only a few life cycle inventories (LCI) of energy and materials flows are available for the industrial recycling processes that are used today to recycle crystalline silicon-based (c-Si) PV modules. LCI are the data inputs that inform lifecycle assessments which quantify the environmental impacts across the full life cycle of PV modules - from manufacturing and use to end of life. To help progress the industry forward, a survey of European recyclers was performed to characterize existing commercial recycling processes and share associated life cycle inventory data. System Boundaries: The reference unit, or "functional unit" in the vocabulary of life cycle assessment, is defined as the processing of one metric ton of crystalline silicon PV modules in recycling lines for laminated glass, metals, and electronic wastes. Today, all modules are processed in discrete batches, yet not metered at that scale. Thus the process energy for a batch is estimated based on scaled annual production data as well as on input and output streams.

14 SOLAR ENERGY↗

Bifacial PV Module Energy Modeling Validation Study

The cost delta between monofacial and bifacial photovoltaic (PV) modules was decreasing in 2018 when this study was initially proposed, making bifacial modules an attractive offering. However, there were limited field studies available that could be considered utility-scale representative, and PV module manufacturers were stating large ranges for the expected energy yield improvements of bifacial technology. This generated uncertainties regarding bifacial performance gains and the actual LCOE (levelized cost of energy). There was also relatively low confidence in the industry’s energy modeling tools’ ability to accurately predict bifacial energy yield, meaning that early adopters of bifacial modules were not able to fully account for the increased energy yield in their energy and financial models. The intent of this project was to provide the solar industry with greater certainty on the energy yield gains of bifacial modules and provide higher confidence in the ability for different energy modeling software to model bifacial PV site performance. Achieving this would allow for bifacial technology to become bankable (i.e. accepted by Independent Engineers, site financiers and other PV site stakeholders), offering a step change in PV site performance that had not been seen since the widespread adoption of the single-axis tracker. Over the course of this study other economic factors including a significant tariff exemption for bifacial modules resulted in accelerated adoption of bifacial technology throughout the US utility scale solar segment. The number of early adopters increased rapidly, and with many investors accepting this module choice the question of bifacial bankability was seemingly answered faster than expected. However, PVEL’s study has still achieved significant accomplishments in demonstrating the accuracy of bifacial modeling across three different software platforms. The results of this study have shown that the mean biased error (MBE) between the field data and the predicted values from all three software platforms were aligned with a maximum MBE of 1.3% and a minimum MBE of -1.8%.

14 SOLAR ENERGY↗

Development of POTATO for 2S Module Grading for the CMS Phase-2 Outer Tracker Upgrade

Due to the High Luminosity-Large Hadron Collider (HL-LHC) upgrade, several detectors of the Compact Muon Solenoid (CMS) will need to be upgraded, specifically the new Outer Tracker detector that will be composed of 13,200 silicon modules. The Outer Tracker features two types of modules; the PS (pixel-strip) and the 2S (strip-strip) modules. With a large influx of production of modules, extensive testing is required to ensure they fulfill the performance requirements. This research introduces POTATO (Phase-II Outer Tracker Analyzer of Test Outputs), a specialized software developed in C++ to analyze, grade, and store results in a centralized database since module data will be collected from various international production facilities. The implementation of POTATO will facilitate the selection of the best performing modules for the Outer Tracker upgrade. This paper is focused on the implementation of the analysis of 2S Module results within POTATO.

43 PARTICLE ACCELERATORS↗

CFD modeling of high-flux plate-and-frame membrane modules for industrial carbon capture

In this work, we study the application of membrane-based separation systems for carbon capture, considering plate-and-frame membrane modules. The successful deployment of membrane CO2 capture system relies on high-performing membranes as well as effective membrane modules that can fully exploit the developed membranes. A plate-and-frame membrane module is especially attractive for CO2 capture from industrial flue gas due to its lower pressure drop compared to its counterparts such as spiral wound modules and hollow fiber modules. To design better plate-and-frame modules, we investigate their basic unit - a single membrane stack through a combination of computational modeling and experimental investigations. The modeling approach is based on Computational Fluid Dynamics (CFD) to represent a multiphysics problem, including the fluid flow and diffusion processes within a membrane module. We use experimental data collected under different operating conditions to validate the CFD model. Numerical results suggest a good agreement between experiments and model outputs for the CO2 recovery, CO2 mole fraction in the retentate and permeate, and stage-cut. The CFD model is able to predict accurately the flow behavior, providing valuable insights on the effects of fluid dynamics on mass transfer of CO2. We also carry out a sensitivity analysis to identify the effect of key parameters on the CO2 recovery and the CO2 purity of the outlet streams.

Dosso, Cheick↗

Investigation and Diagnosis of Faulty Data Channels in CMS Outer Tracker Module Testing

The High-Luminosity Large Hadron Collider (HL-LHC) is currently undergoing upgrades to improve its luminosity. In parallel, this requires an upgrade to the Compact Muon Solenoid (CMS)’s Outer Tracker, consisting of Pixel-Strip (PS) and Strip-Strip (2S) modules that can accurately track the path of charged particles originating from the collisions. It follows that such complex modules call for extensive testing, requiring a sophisticated Data Acquisition (DAQ) system that can perform specific tests to assess their performance. In addition, errors caused by the hardware of a given testing station, and its associated data channel, need to be accurately identified to guarantee proper testing of modules. We have developed a software extension to the Phase-II Outer Tracker Analyzer of Test Outputs (POTATO), which is a specialized software designed to analyze and grade all of the module tests through a centralized database. This extension categorizes and analyzes module test results by its station and data channel. Its analysis can be used to identify trends in grading that indicate issues in these channels’ grading process rather than in the individual modules. This poster shows our methodology and results for identifying faulty data channels. Using this extension, we can quickly diagnose and address problems in our DAQ system, ensuring proper evaluation corrections for each module.

Chen, Angus [Fermilab]↗

Investigation and Diagnosis of Faulty Data Channels in CMS Outer Tracker Module Testing

The High-Luminosity Large Hadron Collider (HL-LHC) is currently undergoing upgrades to improve its luminosity. In parallel, this requires an upgrade to the Compact Muon Solenoid (CMS)’s Outer Tracker, consisting of Pixel-Strip (PS) and Strip-Strip (2S) modules that can accurately track the path of charged particles originating from the collisions. It follows that such complex modules call for extensive testing, requiring a sophisticated Data Acquisition (DAQ) system that can perform specific tests to assess their performance. In addition, errors caused by the hardware of a given testing station, and its associated data channel, need to be accurately identified to guarantee proper testing of modules. We have developed a software extension to the Phase-II Outer Tracker Analyzer of Test Outputs (POTATO), which is a specialized software designed to analyze and grade all of the module tests through a centralized database. This extension categorizes and analyzes module test results by its station and data channel. Its analysis can be used to identify trends in grading that indicate issues in these channels’ grading process rather than in the individual modules. This poster shows our methodology and results for identifying faulty data channels. Using this extension, we can quickly diagnose and address problems in our DAQ system, ensuring proper evaluation corrections for each module.

Chen, Angus [Fermilab]↗

System and method of modulating electrical signals using photoconductive wide bandgap semiconductors as variable resistors

A system and method for producing modulated electrical signals. The system uses a variable resistor having a photoconductive wide bandgap semiconductor material construction whose conduction response to changes in amplitude of incident radiation is substantially linear throughout a non-saturation region to enable operation in non-avalanche mode. The system also includes a modulated radiation source, such as a modulated laser, for producing amplitude-modulated radiation with which to direct upon the variable resistor and modulate its conduction response. A voltage source and an output port, are both operably connected to the variable resistor so that an electrical signal may be produced at the output port by way of the variable resistor, either generated by activation of the variable resistor or propagating through the variable resistor. In this manner, the electrical signal is modulated by the variable resistor so as to have a waveform substantially similar to the amplitude-modulated radiation.

36 MATERIALS SCIENCE↗

Evaluation of Maxim Module-Integrated Electronics at the DOE Regional Test Centers (Presentation)

Module-embedded power electronics developed by Maxim Integrated are under evaluation through a partnership with the Department of Energy's Regional Test Center (RTC) program. Field deployments of both conventional modules and electronics-enhanced modules are designed to quantify the performance advantage of Maxim's products under different amounts of interrow shading, and their ability to be deployed at a greater ground-coverage ratio than conventional modules. Simulations in PVSYST have quantified the predicted performance difference between conventional modules and Maxim's modules from interrow shading. Initial performance results have identified diffuse irradiance losses at tighter row spacing for both the Maxim and conventional modules. Comparisons with published models show good agreement with models predicting the greatest diffuse irradiance losses. At tighter row spacing, all of the strings equipped with embedded power electronics outperformed their conventional peers. An even greater performance advantage is predicted to occur in the winter months when the amount of interrow shading mismatch is at a maximum.

14 SOLAR ENERGY↗

Thermal Modeling Studies for Active Storage Modules in the Calvert Cliffs ISFSI

Temperature measurements obtained for two storage modules in the Calvert Cliffs Nuclear Power Station’s Independent Spent Fuel Storage Installation (ISFSI) as part of the Used Fuel Disposition Campaign of the Department of Energy (DOE) were used to perform validation and sensitivity studies on detailed computational fluid dynamics (CFD) models of the concrete storage modules, including the dry storage canister within the modules. The storage modules in the Calvert Cliffs Nuclear Power Station’s ISFSI are a site-specific version of the standard NUHOMS® HSM. The two modules inspected each contained a 24P DSC loaded with 24 CE 14x14 spent fuel assemblies. The thermal analysis was performed using the STAR-CCM+ package, and the models developed for the specific ISFSI modules yielded temperature predictions in actual storage conditions for the concrete structure, the DSC and its contents, including preliminary estimates of fuel cladding temperatures for the used nuclear fuel. The results of this work demonstrate that existing CFD modeling tools can be used to obtain reasonable and accurate detailed representations of spent fuel storage systems with realistic decay heat loadings when the model omits specific conservatisms and bounding assumptions normally used in design-basis and safety-basis calculations. This paper presents sensitivity studies on modeling detail (for the storage module and the DSC), boundary conditions, and decay heat load, to evaluate the effect of the modeling approach on predicted temperatures and temperature distributions. Because nearly all degradation mechanisms for materials and structures comprising dry storage and transportation systems are dependent on temperature, accurate characterization of local temperatures and temperature gradients that the various components of these systems will experience over the entire storage period has been identified as a primary requirement for evaluation of very long term storage of used nuclear fuel.

long term storage↗

Silicon photonic heater-modulator

Photonic modulators, methods of forming photonic modulators and methods of modulating an input optical signal are provided. A photonic modulator includes a disk resonator having a central axis extending along a thickness direction of the disk resonator. The disk resonator includes a modulator portion and a heater portion. The modulator portion extends in an arc around the central axis. A PN junction of the modulator portion is substantially normal to the central axis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗