Lunar heat flow measurement Preliminary report
Determination of lunar interior heat flux, and surface material thermal properties
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Determination of lunar interior heat flux, and surface material thermal properties
The lunar regolith will most likely be a primary raw material for lunar base construction and resource extraction. High-resolution radar observations of the Moon provide maps of radar backscatter that have intensity variations generally controlled by the local slope, material, and structural properties of the regolith. The properties that can be measured by the radar system include the dielectric constant, density, loss tangent, and wavelength scale roughness. The radar systems currently in operation at several astronomical observatories provide the ability to image the lunar surface at spatial resolutions approaching 30 m at 3.8 cm and 12.6 cm wavelengths and approximately 500 m at 70 cm wavelength. The radar signal penetrates the lunar regolith to a depth of 10-20 wavelengths so the measured backscatter contains contributions from the vacuum-regolith interface and from wavelength-scale heterogeneities in the electrical properties of the subsurface material. The three wavelengths, which are sensitive to different scale structures and scattering volumes, provide complementary information on the regolith properties. Aims of the previous and future observations include (1) analysis of the scattering properties associated with fresh impact craters, impact crater rays, and mantled deposits; (2) analysis of high-incidence-angle observations of the lunar mare to investigate measurement of the regolith dielectric constant and hence porosity; (3) investigation of interferometric techniques using two time-delayed observations of the same site, observations that require a difference in viewing geometry less than 0.05 deg and, hence, fortuitous alignment of the Earth-Moon system when visible from Arecibo Observatory.
The dynamics of nanostructured soft materials crucially impact their associated macroscopic material properties, yet they are often difficult to measure due to spatiotemporal limitations of conventional instrumentation. Herein, we use X-ray photon correlation spectroscopy (XPCS) to directly observe particle-scale dynamics during grain growth and coarsening in a BCC- forming diblock polymer melt, with specific attention to the distribution of structural relaxation times associated with the interplanar (110) distance. Following sample quenching from the disordered state, these dynamical phenomena surprisingly exhibit little dependence on time and thermal quench depth. We posit that these relaxations stem from collective particle motions during grain rotation. We also observe unusual internally-referenced heterodyne correlations, which enable measurements of speed distributions within the sample. In this work, these speeds are significantly slower and appear at much longer annealing times than those previously reported during grain nucleation and growth in microphase separated block polymer melts. Drawing on analogies between polycrystalline hard and soft materials, we ascribe these speed distributions to misorientation-dependent grain boundary migration during ordered domain coarsening and anomalously fast, cooperative string-like particle motion along the grain boundaries. Thus, these coherent X-ray measurements provide new opportunities to interrogate grain boundary structure and dynamics in polycrystalline soft materials.
Research results in analytical ultrasonics for characterizing structural materials from metals and ceramics to composites are presented. General topics covered by the conference included: status and advances in analytical ultrasonics for characterizing material microstructures and mechanical properties; status and prospects for ultrasonic measurements of microdamage, degradation, and underlying morphological factors; status and problems in precision measurements of frequency-dependent velocity and attenuation for materials analysis; procedures and requirements for automated, digital signal acquisition, processing, analysis, and interpretation; incentives for analytical ultrasonics in materials research and materials processing, testing, and inspection; and examples of progress in ultrasonics for interrelating microstructure, mechanical properites, and dynamic response.
The next generation of reusable launch vehicles will require technology development in several key areas. Of these key areas, the development of polymeric composite cryogenic fuel tanks promises to present one of the most difficult technical challenges. It is envisioned that a polymer matrix composite (PMC) tank would be a large shell structure capable of containing cryogenic fuels and carrying a range of structural loads. The criteria that will be imposed on such a design include reduced weight, conformal geometry, and impermeability. It is this last criterion, impermeability, that will provide the focus of this paper. The essence of the impermeability criterion is that the tank remains leak free throughout its design lifetime. To address this criterion, one of the first steps is to conduct a complete durability assessment of the PMC materials. At Langley Research Center, a durability assessment of promising new polyimide-based PMCs is underway. This durability program has focused on designing a set of critical laboratory experiments that will determine fundamental material properties under combined thermal-mechanical loading at cryogenic temperatures. The test program provides measurements of lamina and laminate properties, including strength, stiffness, and fracture toughness. The performance of the PMC materials is monitored as a function of exposure conditions and aging time. Residual properties after exposure are measured at cryogenic temperatures and provide quantitative values of residual strength and stiffness. Primary degradation mechanisms and the associated damage modes are measured with both destructive and nondestructive techniques. In addition to mechanical properties, a range of physical properties, such as weight, glass transition, and crack density, are measured and correlated with the test conditions. This paper will report on the progress of this research program and present critical results and illustrative examples of current findings.
The ordering of organic (carbon-based) molecules into nanostructures drives useful materials properties for applications such as organic light emitting diodes, flexible batteries, and polymer nanocarriers. However, there is a current lack of techniques to measure this ordering. X-ray scattering techniques involving molecular resonances have shown promise in identifying molecular types, locations, and orientation. However, resonant soft X-ray scattering (RSoXS) techniques have not been developed even lacking basic optical models. The objectives achieved by this research were the development of methods, models, and analysis techniques that harness these resonant phenomena in X-ray scattering measurements to quantitatively probe ordering of organic molecules within devices and nanostructures. This award resulted in 11 peer reviewed publications with two others soon to be submitted. New physical models for X-ray scattering that accurately describe these complex molecular resonances enable measurements of how molecules assemble, orient and conform at the nanometer scale. These new techniques were applied to both organic electronic devices and aqueous nanoparticles being developed for hydrocarbon sequestration. This new measurement capability will enable characterization of structure-property relationships that lead to disruptive technologies of printable, stretchable, and biocompatible devices based on organic materials.
Atomic-scale modeling methods such as density functional theory (DFT) and molecular dynamics (MD) can predict the thermodynamic properties of materials at a lower cost than experimental measurements. However, their regular usage in thermodynamic model construction is hampered by the lack of quantitative agreement with experimental measurements and the lack of uncertainty estimates on the data. To make regular usage of this atomistic simulation data, it is important to assess whether the atomistic simulation datasets, by themselves or in combination with experimental measurements, result in the same physics-informed models best supported by experimental measurements alone. Here, models of aluminum thermodynamic properties are discussed using three data sources: atomistic calculations (DFT and MD), experiments, and a combination of atomistic calculations and experiments. The study shows that, after ensuring self-consistency in predicting key invariant points, both experimental measurements and atomistic calculations can significantly contribute to an optimal model.
Materials currently populating Earth orbital regimes can be distinguished by comparing remote observational data to that of optical material measurements obtained in the laboratory. Experimentation for this research primarily involved the acquisition of spectroscopic measurements on materials of interest to the telescopic observational community for enhanced space situational awareness. Common spacecraft materials worthy of preeminent analysis for this investigation include a carbon-carbon (c-c) matrix composite, various black thermal paints, a GPS solar cell and three different cover glass components. These materials were subjected to a simulated geosynchronous Earth orbit (GEO) space environment with the intent of observing material optical property behavior over quantitative exposure time. The aforementioned materials have been measured in their pristine and GEO simulated exposed conditions. A reflectance spectrometer and a bi-directional reflectance distribution function (BRDF) optical system have been operated to perform material characterization, optical property analysis, and to further compare such data to telescopic observational data acquired on equal materials.
Researchers at the NASA Glenn Research Center have developed a unique multiwavelength pyrometer for aerospace applications. It has been shown to be a useful and versatile instrument for measuring the surface temperatures of ceramic zirconia thermal barrier coatings (TBCs) and alumina, even when their emissivity is unknown. The introduction of fiber optics into the pyrometer has greatly increased the ease of using this instrument. Direct comparison of measurements obtained using the pyrometer and thin film thermocouples on a sample provided independent verification of pyrometry temperature measurement. Application of the pyrometer has also included simultaneous surface and bulk temperature measurement in a transparent material, the measurement of combustion gas temperatures in the flames of an atmospheric burner, the measurement of the temperature distribution appearing on a large surface from the recording of just a single radiation spectrum emitted from this nonuniform temperature surface, and the measurement of some optical properties for special aeronautical materials-such as nanostructured layers. The multiwavelength pyrometer temperature is obtained from a radiation spectrum recorded over a broad wavelength region by transforming it into a straight line segment(s) in part or all of the spectral region. The intercept of the line segment(s) with the vertical axis at zero wavelength gives the inverse of the temperature. In a two-color pyrometer, the two data points are also amenable to this analysis to determine the unknown temperature. Implicit in a two-color pyrometer is the assumption of wavelength-independent emissivity. Its two (and minimum) pieces of data are sufficient to determine this straight line. However, a multiwavelength pyrometer not only has improved accuracy but also confirms that the wavelength-independent emissivity assumption is valid when a multitude of data points are shown to lie on a simple straight line.
Insulation systems composed of micrometer-sized fibers bonded together with small amounts of binder have been developed for aerospace applications. The materials have a very high volid content and low density and can be characterized as a rigidized network of fibers randomly oriented in three-dimensional space. Analytical models suitable for the evaluation of the mechanical behavior of rigidized fibrous materials have been developed. The models treat the material as a space frame structure and includes the effects of joint fixity and fiber curvature. The geometrical and material property variabilities are represented by a number of trusses oriented in five planes. Each truss may have different material and geometric properties. Techniques have been developed to describe the continuous material property and geometry functions as a series of descrete quantities that can be used to describe each of the trusses in the model. Parametric studies were performed to show the influence of material variables on the mechanical behavior of the material. Results of calculations show good agreement with measured properties.
Abstract A new solid solution (1− x )Bi(Fe 2/8 Ti 3/8 Mg 3/8 )O 3 –( x )PbTiO 3 (BFTM‐PT) is synthesized and the electromechanical properties are measured. This system is defined as a low‐lead material with ferroelectric/piezoelectric behavior and a morphotropic phase boundary (MPB) that leads to enhanced properties. The MPB is located between x = 0.30 and 0.35 and coincides with a structural phase transition and a sharp increase in the piezoelectric response. The system demonstrates ferroelectric hysteresis where x = 0.325 displays the best properties with a maximum polarization of 39 µC cm −2 and a remnant polarization of 26 µC cm −2 . The range of compositions has high Curie temperature ( T c ), ranging from 625–650 °C. Materials with a T c above 400 °C typically have a low d 33 of <50 pC N −1 at room temperature. However, BFTM‐PT has a higher d 33 that most other compositions with a T c in this range, with the highest being 145 pC N −1 for x = 0.375. The d 33 drops off above 100 °C, but doping studies can be done in the future to stabilize the piezoelectric response at higher temperatures. These outstanding properties open the possibility of new transducer applications, in particular ones requiring high temperature and high power.
Array failure modes, relevant materials property changes, and primary degradation mechanisms are discussed as a prerequisite to identifying suitable measurement techniques and instruments. Candidate techniques and instruments are identified on the basis of extensive reviews of published and unpublished information. These methods are organized in six measurement categories - chemical, electrical, optical, thermal, mechanical, and other physicals. Using specified evaluation criteria, the most promising techniques and instruments for use in life prediction tests of arrays were selected.
The properties of molten semiconductors are good indicators for material structure transformation and hysteresis under temperature variations. Viscosity, as one of the most important properties, is difficult to measure because of high temperature, high pressure, and vapor toxicity of melts. Recently, a novel method was developed by applying a rotating magnetic field to the melt sealed in a suspended quartz ampoule, and measuring the transient torque exerted by rotating melt flow on the ampoule wall. The method was designed to measure viscosity in short time period, which is essential for evaluating temperature hysteresis. This paper compares the theoretical prediction of melt flow and ampoule oscillation with the experimental data. A theoretical model was established and the coupled fluid flow and ampoule torsional vibration equations were solved numerically. The simulation results showed a good agreement with experimental data. The results also showed that both electrical conductivity and viscosity could be calculated by fitting the theoretical results to the experimental data. The transient velocity of the melt caused by the rotating magnetic field was found reach equilibrium in about half a minute, and the viscosity of melt could be calculated from the altitude of oscillation. This would allow the measurement of viscosity in a minute or so, in contrast to the existing oscillation cup method, which requires about an hour for one measurement.
Twenty thin film specimens were flown on M1SSE-5 as a cooperative effort between several organizations. This presentation will report results of initial inspections and post-flight measurements of the optical properties and recession of these materials due to the approx.13 month exposure period on the exterior of the International Space Station. These specimens were located on the "anti-solar" side of the MISSE-5 container and received a low number of Equivalent Sun Hours of solar UV exposure. Profilometry and/or ATF measurements will be conducted to determine thickness changes and atomic oxygen-induced recession rates Six of the specimens were covered with thin Kapton films, 0.1 and 0.3 mil in thickness. The 0.1 mil Kapton was almost completely eroded, suggesting that the atomic oxygen fluence is <8 x 10(exp 19) atoms/sq cm, similar to levels experienced during Space Shuttle materials experiments in the 1980's and 1990's. A comparison of results from MISSE-5 and Space Shuttle experiments will be included for those materials common to both the short and long-term exposures.
Remote sensing measurements provide information about the Martian surface at scales smaller than can be inferred from imaging data alone. Measurements of Martian volcanoes obtained at visual, infrared, and radar wavelengths are discussed in order to evaluate the physical properties. A related issue involves identifying possible ash deposits by distinctive or anomalous physical characteristics.
Magnetic bearings have demonstrated the capability for achieving positioning accuracies at the nanometer level in precision motion control stages. This makes possible the positioning of a wafer in six degrees of freedom with the precision necessary for photolithography. To control the position of an object at the nanometer level, a model of the magnetic bearing actuator force-current-airgap relationship must be accurately obtained. Additionally, to reduce thermal effects the design of the actuator should be optimized to achieve maximum power efficiency and flux density. Optimization of the actuator is accomplished by proper pole face sizing and utilizing a magnetic core material which can be magnetized to the highest flux density with low magnetic loss properties. This paper describes the construction of a magnetic bearing calibration fixture designed for experimental measurement of the actuator force characteristics. The results of a material study that review the force properties of nickel-steel, silicon-steel, and cobalt-vanadium-iron, as they apply to magnetic bearing applications are also presented.
Material synthesis is one of the most important aspects in humankinds’ endeavor to discover and create new materials for energy applications. One strategy to tailor materials with desired functions in a rational way is by knowing how functions relate to structure, synthetic variables, arrangement of atoms and molecules, and how functions evolve during synthesis. In order to accelerate materials synthesis, discovery, and optimization by 10 times it is the right time now to integrate computational tools, synthesis, and characterization. One particular barrier to realizing this concept is the understanding of when and how phases form in real time during synthesis, which is challenging to asses by existing theoretical frameworks. In addition, transient or metastable phases with positive free energy above the lowest-free energy ground state can be revealed by such real time (in situ) measurements. Metastable materials are ubiquitous in condensed matter and can show superior properties compared to their equilibrium form. This work discusses the value of emerging multimodal in situ characterizations exemplified on hybrid halide perovskites. Finally, the ways in which the implementation of in situ measurements can advance the materials science synthesis field as well as their role to enable close-loop feedback control and autonomous synthesis are discussed.
Nano-piezoelectric materials have drawn tremendous research interest. However, characterization of their piezoelectric properties, especially measuring the piezoelectric strain coefficients, remains a challenge. Normally, researchers use an AFM-based method to directly measure nano-materials’ piezoelectric strain coefficients. But, the extremely small piezoelectric deformation, the influence from the parasitic electrostatic force, and the environmental noise make the measurement results questionable. In this paper, a resonant piezo-force microscopy method was used to accurately measure the piezoelectric deformation from 1D piezoelectric nanofibers. During the experiment, the AFM tip was brought into contact with the piezoelectric sample and set to work at close to its first resonant frequency. A lock-in amplifier was used to pick up the sample’s deformation signal at the testing frequency. By using this technique, the piezoelectric strain constant d 33 of the Lead Zirconate Titanate (PZT) nanofiber with a diameter of 76 nm was measured. The result showed that d 33 of this PZT nanofiber was around 387 pm/V. Meanwhile, by tracking the piezoelectric deformation phase image, domain structures inside PZT nanofibers were identified.