Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “masers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Status of local oscillators for operating ultra-high resolution frequency discriminators as frequency standards

The operation of new improved frequency standards based on new ultra-high-resolution frequency discriminators requires high stability local, or 'flywheel' oscillators. We review the spectral density of phase fluctuations of existing flywheel oscillators and the related time domain frequency stability of new and proposed cryogenically cooled oscillators suitable for this application. Presently used devices include the quartz crystal oscillator, the room-temperature actively oscillating atomic hydrogen (H) maser, and the superconducting maser oscillator. Future devices include the cryogenic H-maser and other cryogenic devices using resonators of superconducting metal or solid crystalline sapphire. The relation of the phase spectral density of these devices to the characteristics of present and proposed frequency discriminators based on trapped cooled ions and cold atoms is discussed in terms of their operation as frequency standards.

Vessot, R. F. C.↗

Time scale algorithms for an inhomogeneous group of atomic clocks

Through the past 17 years, the time scale requirements at the National Research Council (NRC) have been met by the unsteered output of its primary laboratory cesium clocks, supplemented by hydrogen masers when short-term stability better than 2 x 10(exp -12)tau(sup -1/2) has been required. NRC now operates three primary laboratory cesium clocks, three hydrogen masers, and two commercial cesium clocks. NRC has been using ensemble averages for internal purposes for the past several years, and has a realtime algorithm operating on the outputs of its high-resolution (2 x 10(exp -13) s at 1 s) phase comparators. The slow frequency drift of the hydrogen masers has presented difficulties in incorporating their short-term stability into the ensemble average, while retaining the long-term stability of the laboratory cesium frequency standards. We report on this work on algorithms for an inhomogeneous ensemble of atomic clocks, and on our initial work on time scale algorithms that could incorporate frequency calibrations at NRC from the next generation of Zacharias fountain cesium frequency standards having frequency accuracies that might surpass 10(exp -15), or from single-trapped-ion frequency standards (Ba+, Sr+,...) with even higher potential accuracies. The requirements for redundancy in all the elements (including the algorithms) of an inhomogeneous ensemble that would give a robust real-time output of the algorithms are presented and discussed.

Jacques, C.↗

Cryogenic, low-noise high electron mobility transistor amplifiers for the Deep Space Network

The rapid advances recently achieved by cryogenically cooled high electron mobility transistor (HEMT) low-noise amplifiers (LNA's) in the 1- to 10-GHz range are making them extremely competitive with maser amplifiers. In order to address future spacecraft navigation, telemetry, radar, and radio science needs, the Deep Space Network is investing both maser and HEMT amplifiers for its Ka-band (32-GHz) downlink capability. This article describes the current state cryogenic HEMT LNA development at Ka-band for the DSN. Noise performance results at S-band (2.3 GHz) and X-band (8.5 GHz) for HEMT's and masers are included for completeness.

Bautista, J. J.↗

Russian national time scale long-term stability

The Institute of Metrology for Time and Space NPO 'VNIIFTRI' generates the National Time Scale (NTS) of Russia -- one of the most stable time scales in the world. Its striking feature is that it is based on a free ensemble of H-masers only. During last two years the estimations of NTS longterm stability based only on H-maser intercomparison data gives a flicker floor of about (2 to 3) x 10(exp -15) for averaging times from 1 day to 1 month. Perhaps the most significant feature for a time laboratory is an extremely low possible frequency drift -- it is too difficult to estimate it reliably. The other estimations, free from possible inside the ensemble correlation phenomena, are available based on the time comparison of NTS relative to the stable enough time scale of outer laboratories. The data on NTS comparison relative to the time scale of secondary time and frequency standards at Golitzino and Irkutsk in Russia and relative to NIST, PTB and USNO using GLONASS and GPS time transfer links gives stability estimations which are close to that based on H-maser intercomparisons.

Alshina, A. P.↗

Anticipated uncertainty budgets of PRARETIME and T2L2 techniques as applied to ExTRAS

The Experiment on Timing Ranging and Atmospheric Soundings, ExTRAS, was conceived jointly by the European Space Agency, ESA, and the Russian Space Agency, RSA. It is also designated the 'Hydrogen-maser in Space/Meteor-3M project'. The launch of the satellite is scheduled for early 1997. The package, to be flown on board a Russian meteorological satellite includes ultra-stable frequency and time sources, namely two active and auto-tuned hydrogen masers. Communication between the on-board hydrogen masers and the ground station clocks is effected by means of a microwave link using the modified version for time transfer of the Precise Range And Range-rate Equipment, PRARETIME, technique, and an optical link which uses the Time Transfer by Laser Link, T2L2, method. Both the PRARETIME and T2L2 techniques operate in a two-directional mode, which makes it possible to carry out accurate transmissions without precise knowledge of the satellite and station positions. Due to the exceptional quality of the on-board clocks and to the high performance of the communication techniques with the satellite, satellite clock monitoring and ground clocks synchronization are anticipated to be performed with uncertainties below 0.5 ns (1 sigma). Uncertainty budgets and related comments are presented.

Thomas, Claudine↗

The effects of clock errors on timescale stability

The weighting scheme for the cesium clocks and hydrogen masers constituting the USNO timing ensemble is reexamined from an empirical standpoint of maximizing both frequency accuracy and timescale uniformity. The utility of a sliding-weight relation between the masers and the cesiums is reaffirmed, but improvement is found if one incorporates inverse Allan variances for sampling times of 12 and 6 hours for the cesiums and masers, respectively, with some dependence on clock model.

Breakiron, Lee A.↗

Stability and Phase Noise Tests of Two Cryo-Cooled Sapphire Oscillators

A cryocooled Compensated Sapphire Oscillator (CSO), developed for the Cassini Ka-band Radio Science experiment, and operating in the 8K - 10K temperature range was previously demonstrated to show ultra-high stability of sigma(sub y) = 2.5 x 10 (exp -15) for measuring times 200 seconds less than or equal to tau less than or equal to 600 seconds using a hydrogen maser as reference. We present here test results for a second unit which allows CSO short-term stability and phase noise to be measured for the first time. Also included are design details of a new RF receiver and an intercomparison with the first CSO unit. Cryogenic oscillators operating below about 10K offer the highest possible short term stability of any frequency sources. However, their use has so far been restricted to research environments due to the limited operating periods associated with liquid helium consumption. The cryocooled CSO is being built in support of the Cassini Ka-band Radio Science experiment and is designed to operate continuously for periods of a year or more. Performance targets are a stability of 3-4 x 10 (exp -15) (1 second less than or equal to tau less than or equal to 100 seconds) and phase noise of -73dB/Hz @ 1Hz measured at 34 GHz. Installation in 5 stations of NASA's deep space network (DSN) is planned in the years 2000 - 2002. In the previous tests, actual stability of the CSO for measuring times tau less than or equal to 200 seconds could not be directly measured, being masked by short-term fluctuations of the H-maser reference. Excellent short-term performance, however, could be inferred by the success of an application of the CSO as local oscillator (L.O.) to the JPL LITS passive atomic standard, where medium-term stability showed no degradation due to L.O. instabilities at a level of (sigma)y = 3 x 10 (exp -14)/square root of tau. A second CSO has now been constructed, and all cryogenic aspects have been verified, including a resonator turn-over temperature of 7.907 K, and Q of 7.4 x 10 (exp 8). These values compare to a turn-over of 8.821 K and Q of 1.0 x 10 (exp 9) for the first resonator. Operation of this second unit provides a capability to directly verify for the first time the short-term (1 second less than or equal to tau less than or equal to 200 seconds) stability and the phase noise of the CSO units. The RF receiver used in earlier tests was sufficient to meet Cassini requirements for tau greater than or equal to 10 seconds but had short-term stability limited to 2-4 x 10 (exp -14) at tau = 1 second, a value 10 times too high to meet our requirements. A new low-noise receiver has been designed to provide approximately equal to 10-15 performance at 1 second, and one receiver is now operational, demonstrating again short-term CSO performance with H maser-limited stability. Short-term performance was degraded in the old receiver due to insufficient tuning bandwidth in a 100MHZ quartz VCO that was frequency-locked to the cryogenic sapphire resonator. The new receivers are designed for sufficient bandwidth, loop gain and low noise to achieve the required performance.

Dick, G. John↗

X-ray Observations of the Supernova Remnants G349.7+0.2 and CTA 1

This compact, high luminosity SNR is known to be interacting with a molecular cloud, based on the observation of OH masers. The maser lines provide velocity measurements which place the remnant at a distance of 22 kpc. The analysis of our ASCA data is now complete. We find that the X-ray emission from this remnant is dominated by material of solar abundances, consistent with the picture of a molecular cloud interaction. At the very large distance indicated by the masers, the observed flux makes G349.7+0.2 one of the most luminous SNRs in our galaxy. We show that the X-ray emitting plasma is not in ionization equilibrium, and that while the remnant has swept up large amounts of material, it is actually relatively young, holding some promise for identification of stellar ejecta in future high resolution studies. A paper detailing our analysis and results has been completed and is in the final stages of circulation amongst co-authors prior to submission to ApJ.

Slane, Patrick O.↗

Is there an Obscured AGN in the Normal Galaxy IRASF01063-8034

The target galactic nucleus is ostensibly "normal," but the presence of water maser emission indicates that it may be an obscured AGN. Our primary goal has been to test this hypothesis through the detection hard X-ray emission and an X-ray spectrum characteristic of heavy absorption. The data for this program became available in May 2003. Light curves show that most of the data are good and that the background was well behaved. We have constructed images and found the X-ray emission in this target is a hard and may be extended. The presence of an AGN has been confirmed through observation with XMM. This is one of many edge-on normal galaxies that may contain AGN. The orientation of the extension will be compared to the structure of molecular gas observed at high angular resolution with VLBI. These radio observations were completed in August 2003. Correlation was completed in late 2003. The data have yet to be delivered by the ATNF. Since the start of the program, we have also obtained six radio spectra, on top of the two obtained at or close to the epoch of discovery for the maser. Early indications were that the maser emission exhibited unusually broad velocity extent and that it "jumped in velocity on time scales of weeks. This behavior has been speculated to be the signature of emission excited by jet-ISM interactions. After more extensive and more sensitive radio study, we find that (1) the emission does not in fact change velocity centroid substantially and (2) it comprises narrower, more "normal" emission features. The joint interpretation of radio and XMM data will be possible once the VLBI images and position-resolved X-ray spectra have been made, probably in summer 2004. If the radio emission arises in an accretion disk, rather than a jet, then we may predict that the VLBI images will exhibit velocity-position gradients orthogonal to the extension of X-ray emission, which presumably traces an optical narrow line or outflow region.

Greenhill, Lincoln J.↗

Deep Space Network, Cryogenic HEMT LNAs

Exploration of the Solar System with automated spacecraft that are more than ten astronomical units (1 AU = 149,597,870.691 km) from earth requires very large antennae employing extremely sensitive receivers. A key figure of merit in the specification of the spacecraft-to-earth telecommunications link is the ratio of the antenna gain to operatio nal noise temperature (G/Top) of the system. The Deep Space Network (DSN) receivers are cryogenic, low-noise amplifiers (LNAs) which addres s the need to maintain Top as low as technology permits. Historicall y, the extra-ordinarily sensitive receive systems operated by the DSN have required ctyogenically cooled, ruby masers, operating at a physi cal temperature near the boiling point of helium, as the LNA. Althoug h masers continue to be used today, they are hand crafted at JPL and expensive to manufacture and maintain. Recent advances in the developm ent of indium phosphide (InP) based high electron mobility transistor s (HEMTs) combined with cryogenic cooling near the boiling point of h ydrogen have made this alternate technology comparable with and a fraction of the cost of maser technology. InP HEMT LNA modules are demons trating noise temperatures less than ten times the quantum noise limi t (10hf/k) from 1 to 100 GHz. To date, the lowest noise LNA modules developed for the DSN have demonstrated noise temperatures of 3.5 K and 8.5 K at 8.5 K at 32 GHz, respectively. Front-end receiver packages employing these modules have demonstrated operating system noise temperatures of 17 K at 8.4 GHz (on a 70m antenna at zenith) and 39 K at 3 2 GHz (on a 34m antenna at zenith). The development and demonstration of cryogenic, InP HEMT based front-end amplifiers for the DSN requir es accurate component and module characterization, and modeling from 1 to 100 GHz at physical temperatures down to 12 K. The characterizati on and modeling begins with the HEMT chip, proceeds to the multi-stag e HEMT LNA module, and culminates with the complete front-end cryogenic receiver package for the antenna. This presentation will provide a n overview of this development process. Examples will be shown for de vices, LNA modules, front-end receiver packages, antennae employing these packages and the improvements to the down-link capacity.

low-noise amplifiers (LNAs)↗

The EVN Galactic Plane Survey - EGaPS

I present a catalogue of the positions and correlated flux densities of 109 compact extragalactic radio sources in the Galactic plane determined from an analysis of a 48-h Very Long Baseline Interferometry (VLBI) experiment at 22 GHz with the European VLBI Network. The median position uncertainty is 9 mas. The correlated flux densities of the detected sources are in the range of 2-300 mJy. In addition to the target sources, nine water masers have been detected, of which two are new. I derived the positions of the masers with an accuracy of 30-200 mas and determined the velocities of the maser components and their correlated flux densities. The catalogue and the supporting material are available at http://astrogeo.org/egaps.

Petrov, Leonid↗

Simulating Future GPS Clock Scenarios with Two Composite Clock Algorithms

Using the GPS Toolkit, the GPS constellation is simulated using 31 satellites (SV) and a ground network of 17 monitor stations (MS). At every 15-minutes measurement epoch, the monitor stations measure the time signals of all satellites above a parameterized elevation angle. Once a day, the satellite clock estimates the station and satellite clocks. The first composite clock (B) is based on the Brown algorithm, and is now used by GPS. The second one (G) is based on the Greenhall algorithm. The composite clock of G and B performance are investigated using three ground-clock models. Model C simulates the current GPS configuration, in which all stations are equipped with cesium clocks, except for masers at USNO and Alternate Master Clock (AMC) sites. Model M is an improved situation in which every station is equipped with active hydrogen masers. Finally, Models F and O are future scenarios in which the USNO and AMC stations are equipped with fountain clocks instead of masers. Model F is a rubidium fountain, while Model O is more precise but futuristic Optical Fountain. Each model is evaluated using three performance metrics. The timing-related user range error having all satellites available is the first performance index (PI1). The second performance index (PI2) relates to the stability of the broadcast GPS system time itself. The third performance index (PI3) evaluates the stability of the time scales computed by the two composite clocks. A distinction is made between the "Signal-in-Space" accuracy and that available through a GNSS receiver.

global positioning system↗

Local oscillator distribution using a geostationary satellite

A satellite communication system suitable for distribution of local oscillator reference signals for a widely spaced microwave array has been developed and tested experimentally. The system uses a round-trip correction method of the satellite This experiment was carried out using Telstar-5, a commercial Ku-band geostationary satellite. For this initial experiment, both earth stations were located at the same site to facilitate direct comparison of the received signals. The local oscillator reference frequency was chosen to be 300MHz and was sent as the difference between two Ku-band tones. The residual error after applying the round trip correction has been measured to be better than 3psec for integration times ranging from 1 to 2000 seconds. For integration times greater then 500 seconds, the system outperforms a pair of hydrogen masers with the limitation believed to be ground-based equipment phase stability. The idea of distributing local oscillators using a geostationary satellite is not new; several researchers experimented with this technique in the eighties, but the achieved accuracy was 3 to 100 times worse than the present results. Since substantially and the performance of various components has improved. An important factor is the leasing of small amounts of satellite communication bandwidth. We lease three 100kHz bands at approximately one hundredth the cost of a full 36 MHz transponder. Further tests of the system using terminal separated by large distances and comparison tests with two hydrogen masers and radio interferometry is needed.

hydrogen maser↗

Classical laser.

In this paper a completely classical model for laser action is discussed. An active medium consisting of classical anharmonic oscillators interacts with a classical electromagnetic field in a resonant cavity. Comparison with the case of a medium consisting of harmonic oscillators shows the significance of nonlinearities for producing self-sustained oscillations in the radiation field. The results for the classical model are found to be similar to those for a semiclassical model of the ammonia-beam maser. The conclusion is that laser action is not intrinsically a quantum-mechanical effect. The classical-laser theory as given in this paper can also be applied to the case of the electron-cyclotron maser.

Borenstein, M.↗

Expected far infrared polarization of H2 regions and the nuclei of galaxies

The expected polarization of far infrared sources is discussed, and it is shown that the observed degree of polarization generally depends on two factors: (1) the availability of a mechanism that can produce polarization, and (2) the gain in polarization which absorption or stimulated emission can produce within a source. It is pointed out that stimulated emission could produce sizeable gain changes in compact dust clouds such as those associated with H2 regions and possibly also in dense regions exhibiting OH and H2O masers. Whether such a gain can actually become positive (maser-like behavior) is not clear, but this would in any case depend on the chemical structure of the grain material and the spectral range of interest.

Harwit, M. O.↗

A comparison of the cesium and hydrogen hyperfine frequencies by means of Loran-C and portable clocks

A comparison of the hydrogen and cesium hyperfine frequencies is made using a hydrogen maser calibrated directly against the Flexible Bulb Large Storage Box Hydrogen Maser and a Hewlett-Packard portable high performance cesium clock calibrated indirectly against the USNO Master Clock via a Loran-C link. The portable cesium clock is transported from the USNO to Harvard University in operating condition. This allows the evaluation of the portable clock's performance under transport. Data are presented on the epoch and frequency stability of the portable clock under transport as well as the usefulness of a closure measurement in determining clock drift.

Reinhardt, V. S.↗

Very long baseline interferometric observations of OH/IR stars

Results are reported for spectral-line very long baseline interferometric observations of the following II OH/IR objects, which emit strong 1612-MHz OH maser radiation concentrated at two velocities: NML Cyg, R Aql, IRC+10011, IRC-10529, and OH 1837-05. The apparent angular sizes were obtained for NML Cyg and R Aql, and lower limits upon the apparent sizes were obtained for the other objects. The data for NML Cyg agree with previous size determinations and indicate that the low- and high-velocity components are separated by about 20 times their apparent size. The maser component of R Aql is calculated within a factor of two to be about 5 by 10 to the 14th power cm, although the emitting region can be significantly larger. A qualitative description is given for II OH/IR objects with late M-type Mira variable center stars and circumstellar dust shells of similar dimensions.

Reid, M. J.↗