Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Progress toward externally powered x-band dielectric-loaded accelerating structures.

We summarize recent progress in a program to develop externally powered dielectric-loaded accelerating (DLA) structures that can sustain high accelerating gradients. High-power RF tests of earlier structures showed strong multipactor loading. In addition, arcing at dielectric joints between the uniform DLA structure and matching sections at either end limited the achievable gradient. In this paper, we study the onset of multipactor in a DLA structure. We also study the effect of thin-film TiN coatings applied by atomic layer deposition and the effect of a reduction in the inner diameter of the structure. Test results of these structures show significant decreases in multipactor loading. We also test new structure designs that eliminate separate dielectric matching sections and, thus, the requirement for dielectric joints, including a DLA structure using a coaxial coupler and a clamped DLA structure. The clamped structure demonstrated a significantly improved gradient without breakdown.

36 MATERIALS SCIENCE↗

1.5 MW RF Load for ITER

Calabazas Creek Research, Inc. developed a 1.5 MW RF load for the ITER fusion research facility currently under construction in France. This program leveraged technology developed in two previous SBIR programs that successfully developed high power RF loads for fusion research applications. This program specifically focused on modifications required by revised technical performance, materials, and assembly specification for ITER. This program implemented an innovative approach to actively distribute the RF power inside the load to avoid excessive heating or arcing associated with constructive interference. The new design implemented materials and assembly changes required to meet specifications. Critical components were built and successfully tested during the program.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

0D, 1D, 2D, and 3D simulations of an idealized coaxial impedance-matched Marx generator

We have conducted 0D, 1D, 2D, and 3D simulations of an idealized coaxial impedance-matched Marx generator (IMG) []. The 0D calculations were conducted with a four-element circuit model; the 1D, 2D, and 3D calculations were conducted with highly resolved, fully electromagnetic representations. The IMG consists of 30 stages distributed axially and connected electrically in series. Each stage is powered by two bricks separated by 180° and connected electrically in parallel. Each brick comprises two opposite-polarity capacitors in series with a single switch. The bricks drive an internal impedance-matched coaxial transmission line terminated by a resistive load. The simulations neglect effects due to the switch-triggering circuit, the capacitor-charging circuit, external conducting boundaries, and reactive components of the load. We find dimensionality does not significantly affect the electrical power delivered by the IMG to its load: peak load powers estimated by the 0D, 1D, 2D, and 3D simulations agree to within 1%. The 3D calculations demonstrate that electromagnetic power radiated by the bricks, and axial gaps between stages, reduces the peak load power by less than ∼ 1 % . Each simulation assumes the load impedance is 34% above that at which the load power is maximized. Operating an IMG with such an overmatched load offers several advantages while decreasing the peak load power by only 2%. The 0D, 1D, 2D, and 3D models outlined herein could be adapted to assess computationally competing IMG designs, and conduct a variety of numerical IMG experiments, an IMG is constructed. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Robust Time-Varying Parameter Identification for Composite Load Modeling

With the increasing integration of uncertain resources, e.g., renewables, electric vehicles, and demand responses, it is imperative to understand the characteristics of loads for power system analysis and control. Challenges of load modeling come from a variety of load components and time-varying compositions. In addition, the existence of outliers in measurements further complicates the problem. This paper proposes a robust time-varying parameter identification technique for composite ZIP and induction motor load models. A batch-model regression form, including time-varying parameters, is established based on state transition models and observation models with current observations and previous predictions to guarantee data redundancy. To deal with outliers, down-weighting coefficients of measurements are calculated with a projection statistics approach. Based on the batch-model regression and the down-weighting coefficients, parameter identification at each sample time is formulated as a weighted least squares optimization, which is solved by the Newton-Raphson approach with the previous estimated parameters as the initial iteration values. In addition, parameters' sensitivities to different outliers in measurements are analyzed. Results on the IEEE 57-bus system and IEEE 118-bus system show that the proposed algorithm can robustly identify time-varying parameters for the composite load models.

Composite load model↗

Capillary Pumped Loop 3 Flight Experiment Overview

The Capillary Pumped Loop 3 (CAPL 3) Experiment is a follow on to the CAPL 1 and CAPL 2 experiments which flew on STS-60 (2/94) and STS-69 (9/95), respectively. CAPL 3 is tentatively scheduled to fly on the Space Shuttle in late 2000 as part of the Hitchhiker Experiments Advancing Technology (HEAT) payload. The experiment is a joint Naval Research Laboratory (NRL)/Goddard Space Flight Center (GSFC) payload which will meet technology objectives for both the Department of Defense and NASA. The primary objective of CAPL 3 is to demonstrate in space a multiple evaporator capillary pumped loop system, capable of reliable start-up, reliable continuous operation, and at least 50% heat load sharing with hardware for a deployable radiator. CAPL 3 is a full scale CPL system with four parallel capillary evaporators. The loop also contains a capillary starter pump, 8 parallel direct condensation condensers with associated flow regulators, a back pressure regulator, a two-phase reservoir, and various headers and transport tubing. A variable conductance heat pipe is located between one of the evaporators and the experiment radiator to provide a cooling source for the demonstration of heat load sharing. The experiment has an operating power range of 100 W to approximately 1400 W. The experiment ammonia charge will cause it to transition to a fixed conductance mode of operation if the radiator usage reaches 85%. Ambient functional tests have been performed on the experiment. Tests performed included start-up, low power, power cycles, high power, heat load sharing, variable/fixed conductance transition, saturation temperature changes, and pressure primes while the system was operating. The majority of the testing was performed at an ammonia saturation temperature of 30C, but a few tests were done at temperatures above and below this. The testing was highly successful. Details of the tests performed and a discussion of the results will be given in the presentation.

Ottenstein, Laura↗

Integration of Wind Generation and Load Forecast Uncertainties into Power Grid Operations

In this paper, a new approach to evaluate the uncertainty ranges for the required generation performance envelope, including the balancing capacity, ramping capability and ramp duration is presented. The approach includes three stages: statistical and actual data acquisition, statistical analysis of retrospective information, and prediction of future grid balancing requirements for specified time horizons and confidence intervals. Assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on a histogram analysis incorporating all sources of uncertainty and parameters of a continuous (wind forecast and load forecast errors) and discrete (forced generator outages and failures to start up) nature. Preliminary simulations using California Independent System Operator (CAISO) real life data have shown the effectiveness and efficiency of the proposed approach.

17 WIND ENERGY↗

Mitigation of upward and downward vertical displacement event heat loads with upper or lower massive gas injection in DIII-D

Intentionally triggered upward and downward vertical displacement events (VDEs) leading to disruptions were pre-emptively mitigated with neon massive gas injection (MGI) coming from either above or below the plasma. Global indicators of disruption mitigation effectiveness (conducted heat loads, radiated power, and vessel motion) do not show a clear improvement when mitigating with the gas jet located closer to the VDE impact area. A clear trend of improved mitigation is observed for earlier MGI timing relative to the VDE impact time. The plasma edge magnetic perturbation is seen to lock to a preferential phase during the VDE thermal quench, but this phase is not clearly matched by preliminary attempts to fit to the conducted heat load phase. Clear indications of plasma infra-red (IR) emission are observed both before and during the disruptions. This IR emission can affect calculation of disruption heat loads; here, the time decay of post-disruption IR signals is used to correct for this effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Set-Free, All Digital Controlled Point-of-Load Regulator for Next Generation Power Systems: ADC-POL

This paper presents a digitally controlled programmable point-of-load regulator for next-generation power systems. A novel digital control scheme was designed to minimize single-event effect (SEE)-induced transient effects. By effectively programming the loop transmission, the POL can trade off transient response time with SET robustness. The IC works with 1 to 5.5 V input voltage, 1-4.5V regulated output voltage, high efficiency (peak efficiency at 94%) and power of up to 5 W. The design was fabricated in the AMI i2t100 0.7 mu m complimentary, metal-oxide semiconductor (CMOS) process and characterized with the Jet Propulsion Laboratory (JPL) pulsed laser system.

Digital Signal Processing (DP)↗

Hydrogen Storage for Load-Following and Clean Power: Duct-firing of Hydrogen to Improve the Capacity Factor of NGCC Plants (Final Report, Phase I Conceptual Study)

The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and the proposed system is an improvement over alternate low carbon dispatchable power options. Our demonstration will include 54 MWh of hydrogen storage. CO 2 capture inherent to the CHG process can capture 90% of the CO 2 (with upgrades to >98%) in a commercial system (~300 MWth) for sequestration or other uses. The hydrogen will be utilized in a duct burner in a Heat Recovery Steam Generator (HRSG) integrated with the existing Southern Company fossil asset. Here, the firing rate of the duct burner is varied to let the plant respond to fluctuations of electrical load. However, H 2 production is relatively constant by storing H 2 , and revenues are improved by arbitrage between use of low-cost off-peak variable electricity generation or use of stored H 2 under peak demand. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via system requirements review with the whole team. These requirements were then incorporated into/iterated with our Heat & Mass Balance models and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Our system generates power at 17.4% lower cost than other low carbon approaches for the H 2 generation, H 2 compression and storage, carbon sequestration, and HRSG added electricity production for a large-scale duct-fired system. Our team recommends completing the Phase II Pre-FEED study for the proposed system as the next step for the project and its tasks will achieve the overall objective and be ready to launch the FEED. The Pre-FEED tasks include updating the requirements, Concept of Operations, plant scope/process description, component modeling, system modeling, performance estimates, emission estimates, block flow diagrams, fluid/process conditions (PFD), utility usage, and facility sizing/definition. The approach will be to complete these updates in a greater level of detail for the selected site. The approach for developing the EIV is to use the updated results, including model outputs, for carbon dioxide and waste streams.

03 NATURAL GAS↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

Power-Factor Controller With Fast Load Response

Sudden changes in induced emf sensed. In refinement of soft starting three phase power-factor controller, additional components enable circuit to respond quickly to sudden increase in motor load. Rapid-load-response addition senses induced motor emf to detect sudden load increase and generates command signal to increase applied power in response.

Nola, F. J.↗

Characterizing electrical demand and load diversity of low-power water and space heating appliances in US homes

Home renovation and remodeling projects can involve costly and time consuming electrical infrastructure upgrades at the household level. From the grid perspective they also lead to costly replacement of local infrastructure, such as transformers, and can add stress to the grid at peak times. The emergence of innovative, power-efficient household appliances offers a way to minimize these problems. These appliances are designed for lower power consumption, simplifying installation through standard plug-in connections, reducing the need for new electric circuits/panels/service, and minimizing the peak power demand for the home. Key examples include low-power heat pump water heaters (HPWHs) and cold climate window heat pumps that operate on standard 120V outlets. To assess the real-world impact of these solutions, we compiled and analyzed power metering data from several US field studies. This data provides insights into the effects on peak power demand of selecting lower-power appliances. Our analysis focuses on several key metrics, including the maximum power demand of individual appliances, their operational runtime, continuous operation and load diversity. While individual low-power 120V space and water heating appliances offer significant peak demand reductions compared to 240V heat pump or resistance alternatives, their longer runtimes might increase the likelihood of operation during whole-dwelling peak events, albeit at lower power levels.

Less, Brennan↗

Design and Stability of Load-Side Primary Frequency Control in Power Systems

We present a systematic method to design ubiquitous continuous fast-acting distributed load control for primary frequency regulation in power networks, by formulating an optimal load control (OLC) problem where the objective is to minimize the aggregate cost of tracking an operating point subject to power balance over the network. We prove that the swing dynamics and the branch power flows, coupled with frequency-based load control, serve as a distributed primal-dual algorithm to solve OLC. We establish the global asymptotic stability of a multimachine network under such type of load-side primary frequency control. These results imply that the local frequency deviations on each bus convey exactly the right information about the global power imbalance for the loads to make individual decisions that turn out to be globally optimal. Simulations confirm that the proposed algorithm can rebalance power and resynchronize bus frequencies after a disturbance with significantly improved transient performance.

Zhao, CH↗

Control approach for power modulation of end-use loads

Methods, apparatus, and systems are disclosed herein for power modulation control of power grids using end-use loads. At the beginning of a coordination period typically lasting a few minutes, a population of end-use loads (water heaters, air conditioners, plug-in electric vehicles, etc.) is interrogated for their willingness to participate in power modulation by undergoing state transitions from on to off, or off to on. Distribution system flexibilities are calculated from the sums of device powers within distribution systems. Area flexibilities are calculated from the sums of device powers within areas. Thresholds for various devices to change state in response to inter-area oscillation damping or frequency regulation are derived from these flexibilities. Two power functions are monitored in real-time and compared with the device thresholds to trigger state changes which then remain locked throughout the remainder of the coordination period, then the devices are released from the lockout state.

Lian, Jianming↗

Analysis of Electric Vehicle Charging Behavior Patterns with Function Principal Component Analysis Approach

This manuscript focused on analyzing electric vehicles’ (EV) charging behavior patterns with a functional data analysis (FDA) approach, with the goal of providing theoretical support to the EV infrastructure planning and regulation, as well as the power grid load management. 5-year real-world charging log data from a total of 455 charging stations in Kansas City, Missouri, was used. The focuses were placed on analyzing the daily usage occupancy variability, daily energy consumption variability, and station-level usage variability. Compared with the traditional discrete-based analysis models, the proposed FDA modeling approach had unique advantages in preserving the smooth function behavior of the data, bringing more flexibility in the modeling process with little required assumptions or background knowledge on independent variables, as well as the capability of handling time series data with different lengths or sizes. In addition to the patterns revealed in the EV charging station’s occupancy and energy consumption, the differences between EV driver’s charging time and parking time were analyzed and called for the needs for parking regulation and enforcement. The different usage patterns observed at charging stations located on different land-use types were also analyzed.

Engineering↗

On the Effects of Wind Turbine Wake Skew Caused by Wind Veer: Preprint

Because of Coriolis forces caused by the Earth's rotation, the structure of the atmospheric boundary layer often contains wind-direction change with height, also known as wind-direction veer. Under low turbulence conditions, such as in stably stratified atmospheric conditions, this veer can be significant, even across the vertical extent of a wind turbine's rotor disk. The veer then causes the wind turbine wake to skew as it advects downstream. This wake skew has been observed both experimentally and numerically. In this work, we attempt to examine the wake skewing process in some detail, and quantify how differently a skewed wake versus a non skewed wake affects a downstream turbine. We do this by performing atmospheric large-eddy simulations to create turbulent inflow winds with and without veer. In the veer case, there is a roughly 8 degree wind direction change across the turbine rotor. We then perform subsequent large-eddy simulations using these inflow data with an actuator line rotor model to create wakes. The turbine modeled is a large, modern, offshore, multimegawatt turbine. We examine the unsteady wake data in detail and show that the skewed wake recovers faster than the non skewed wake. We also show that the wake deficit does not skew to the same degree that a passive tracer would if subject to veered inflow. Last, we use the wake data to place a hypothetical turbine 9 rotor diameters downstream by running aeroelastic simulations with the simulated wake data. We see differences in power and loads if this downstream turbine is subject to a skewed or non skewed wake. We feel that the differences observed between the skewed and nonskewed wake are important enough that the skewing effect should be included in engineering wake models.

17 WIND ENERGY↗