Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid argon detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Production, quality assurance and quality control of the SiPM Tiles for the DarkSide-20k Time Projection Chamber

The DarkSide-20k dark matter direct detection experiment will employ a 21 m 2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called Tiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout. Tiles are further grouped into Photo-Detector Units (PDUs). This paper details the production of the Tiles and the Quality Assurance and Quality Control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision die attaching, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.

Acerbi, F. [Fondazione Bruno Kessler]↗

Event Selection at the DUNE Near Detector

The Deep Underground Neutrino Experiment (DUNE) is a next generation long-baseline experiment designed with a primary goal of providing definitive measurements of the neutrino mass ordering and the Charge Parity (CP)-violating phase. A key component in reaching these goals is the DUNE Near Detector (ND) complex, placed 574 m from the beam target, and tasked with characterising the neutrino beam and constraining systematic uncertainties before oscillation effects occur. We will present primary findings from the development of an event selection for $\nu_\mu$ CC interactions within the ND liquid argon time projection chamber (ND-LAr). These findings will include a discussion of the importance of defining metrics, such as efficiency and purity, such that we can meet the required sensitivity for DUNE's physics measurements.

Sabater Andres, Eva [Sussex U.] (ORCID:00090001748↗

Towards combination of charge and light readout at O(10) MeV energies in DUNE

The Deep Underground Neutrino Experiment (DUNE) is an experiment under construction that will employ 10-kt scale liquid-argon-TPC technology to do precision measurements of neutrino oscillations. Apart from the determination of CP violation in neutrino interactions, one of the main scientific goals of DUNE is the detection of neutrinos from a supernova burst. It is imperative to maximise the potential of the detector for extracting information for these rare events. The use of light signals to aid the calorimetry of neutrino interactions provides such potential. We will present current efforts to demonstrate the application of combined calorimetry in one of the DUNE prototype detectors at CERN. The ground-level placement of the detector allows collection of large samples of cosmic-ray muons stopping within its volume. Michel electrons from muon decay can be identified in both the ionization charge and scintillation light, serving as a proxy for supernova neutrino interactions at O(10) MeV energies. The method for demonstrating combined calorimetry and its associated challenges will be introduced. We will also summarise the current analysis status and future prospects.

Pěč, Viktor [Prague, Inst. Phys.] (ORCID:000000034↗

Dark Matter-Induced Nuclear De-Excitation at SBND with Ab Initio Nuclear Theory

We explore the sensitivity of the Short-Baseline Near Detector (SBND) experiment to light dark matter using MeV-scale electromagnetic activity. Inelastic scattering of dark matter with argon nuclei can excite nuclear states that subsequently de-excite via the emission of MeV-scale photons, producing localized low-energy "blip" signatures in a liquid argon time projection chamber. We perform state-of-the-art ab initio nuclear calculations, including all relevant argon excited states with energies up to 18 MeV, to provide reliable predictions for these signals. After accounting for relevant backgrounds, we find that SBND can probe previously unexplored regions of parameter space for light dark matter.

Dutta, Bhaskar [Bucharest, IFIN-HH; Texas A-M] (OR↗

Characterizing the energy resolution of the MicroBooNE LArTPC at the MeV scale using monoenergetic features of $^{208}$Tl decays

A detailed understanding of the capabilities and fidelity of low-energy reconstruction is crucial for taking advantage of MeV-scale neutrino physics opportunities in liquid argon time projection chambers (LArTPCs). This study presents a measurement of the resolution of reconstructed energy in the MicroBooNE LArTPC at $\approx 1.5$ MeV. The characterization is performed using monoenergetic signals generated by $2.614$ MeV $γ$-rays from $^{208}$Tl decays undergoing pair production in the detector. The resolution is found to be ($7.52 \pm 0.78 \text{(stat)} \pm 0.92 \text{(syst)}$)%. This value is consistent with the MicroBooNE simulation prediction of ($9.70 \pm 0.65 \text{(stat)}$)% at the $1.6 σ$ level. This study represents the first ever measurement of LArTPC energy resolution at the MeV scale and provides a pathway for monoenergetic energy calibrations in future experiments using LArTPC detectors.

Abratenko, P. [Tufts U.]↗

The track-length extension fitting algorithm for energy measurement of interacting particles in liquid argon TPCs and its performance with ProtoDUNE-SP data

This paper introduces a novel track-length extension fitting algorithm for measuring the kinetic energies of inelastically interacting particles in liquid argon time projection chambers (LArTPCs). The algorithm finds the most probable offset in track length for a track-like object by comparing the measured ionization density as a function of position with a theoretical prediction of the energy loss as a function of the energy, including models of electron recombination and detector response. The algorithm can be used to measure the energies of particles that interact before they stop, such as charged pions that are absorbed by argon nuclei. The algorithm's energy measurement resolutions and fractional biases are presented as functions of particle kinetic energy and number of track hits using samples of stopping secondary charged pions in data collected by the ProtoDUNE-SP detector, and also in a detailed simulation. Additional studies describe the impact of the dE/dx model on energy measurement performance. The method described in this paper to characterize the energy measurement performance can be repeated in any LArTPC experiment using stopping secondary charged pions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status and plans for measurements of Neutrino-Argon interactions at ICARUS

The ICARUS experiment, utilizing Liquid Argon Time Projection Chamber (LAr TPC) technology, has been installed at Fermilab (USA), following its initial operation in Italy and subsequent refurbishment at CERN. ICARUS has successfully been taking physics data at Fermilab since June 2022. While the experiment’s primary objective is to function as the far detector of the Short Baseline Neutrino program (SBN), searching for hints of physics beyond three-flavour PMNS neutrino oscillations, ICARUS also offers other diverse physics capabilities, including searches beyond the standard model and measurements of cross-sections. In addition to being exposed to the common Booster Neutrino (BNB) beamline of the SBN experiment, ICARUS receives neutrinos from the Main Injector (NuMI) beam. Due to the off-axis angle between NuMI and ICARUS, coupled with contributions from both pion and kaon decays to neutrino fluxes, interactions of NuMI neutrinos within ICARUS can be detected over a range of several GeV in energy. Measurements of these interactions present unique opportunities to infer neutrino interaction cross sections on an argon nuclear target within an energy range that overlaps both the SBN oscillation search and a significant portion of the DUNE spectrum. This presentation will summarise the current status of ICARUS’ neutrino cross-section measurements.

Roy, Promita [Fermilab] (ORCID:0000000164958937)↗

Development of a novel, windowless, amorphous selenium based photodetector for use in liquid noble detectors

Detection of the vacuum ultraviolet (VUV) scintillation light produced by liquid noble elements is a central challenge in order to fully exploit the available timing, topological, and calorimetric information in detectors leveraging these media. Here in this paper, we characterize a novel, windowless amorphous selenium based photodetector with direct sensitivity to VUV light. We present here the manufacturing and experimental setup used to operate this detector at low transport electric fields (2.7–5.2 V/μm) and across a wide range of temperatures (77 K–290 K). This work shows that the first proof-of-principle windowless amorphous selenium device is robust under cryogenic conditions, responsive to VUV light at cryogenic temperatures, and preserves argon purity. These findings motivate a continued exploration of amorphous selenium devices for simultaneous detection of scintillation light and ionization charge in noble element detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Search for Dark-Trident Processes Using the MicroBooNE Detector

This thesis presents a first search for dark-trident scattering in a neutrino beam using a data set corresponding to $7.2 \times 10^{20}$ protons on target taken with the MicroBooNE detector at Fermilab. Proton interactions in the neutrino target at the Main Injector produce $\pi^0$ and $\eta$ mesons, which could decay into dark matter (DM) particles via a dark photon $A^{\prime}$. A convolutional neural network is trained to identify interactions of the DM particles in the liquid-argon time projection chamber (LArTPC) exploiting its image-like reconstruction capability. In the absence of a DM signal, limits at the $90\%$ confidence level on the squared kinematic mixing parameter $\varepsilon^2$ as a function of the dark-photon mass in the range $10\le M_{A^\prime}\le 400$~MeV are provided. The limits cover previously unconstrained parameter space for the production of fermion or scalar DM particles $\chi$ for two benchmark models with mass ratios $M_{\chi}/M_{A^\prime}=0.6$ and $2$ and for dark fine-structure constants $0.1\le\alpha_D\le 1$.Date of Award1 Aug 2024Original languageEnglishAwarding InstitutionThe University of ManchesterSupervisorStefan Soldner-Rembold (Supervisor) & Justin Evans (Supervisor)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Search for Dark-Trident Processes Using the MicroBooNE Detector

We present a first search for dark-trident scattering in a neutrino beam using a dataset corresponding to 7.2 × 10 20 protons on target taken with the MicroBooNE detector at Fermilab. Proton interactions in the neutrino target at the main injector produce π 0 and η mesons, which could decay into dark-matter (DM) particles mediated via a dark photon A ′ . A convolutional neural network is trained to identify interactions of the DM particles in the liquid-argon time projection chamber (LArTPC) exploiting its imagelike reconstruction capability. In the absence of a DM signal, we provide limits at the 90% confidence level on the squared kinematic mixing parameter ϵ 2 as a function of the dark-photon mass in the range 10 ≤ M A ′ ≤ 400 MeV . The limits cover previously unconstrained parameter space for the production of fermion or scalar DM particles χ for two benchmark models with mass ratios M χ / M A ′ = 0.6 and 2 and for dark fine-structure constants 0.1 ≤ α D ≤ 1 . Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of Lateral Amorphous Selenium Photodetectors for Low-Photon and VUV Detection at Cryogenic Temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies greater than or equal to 80 percent and area under the curve (AUC) greater than or equal to 0.85 using as few as approximately 6800 incident 401 nm photons, corresponding to approximately 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

FOS: Physical sciences↗

Studies to Improve the Sensitivity to Low Energy Interactions in Dual-Phase Xenon Dark Matter Detectors. Department of Energy Office of Science Graduate Student Research (SCGSR) Program, Final project report

Noble liquid time projection chambers (TPCs) are some of the most sensitive particle detectors ever developed. They see use in searches for new physics with neutrinos, or for new particles like dark matter. They work by sensing light and charge signals left behind by particle interactions in a volume of liquified xenon or argon. TPCs are so sensitive that even a single electron liberated in an interaction can be readily detected. However this sensitivity to signals comes with a sensitivity to background noise, with one example being single electrons that arrive long after the signals from a true particle interaction. This type of noise has been the subject of multiple studies, which have concluded that single electron backgrounds are well correlated with prior events in the TPC, as well as impurities in the detection medium. At Lawrence Livermore National Laboratory (LLNL), the XeNu TPC is a testbed for a novel study of these backgrounds by generating data with new components made of aluminum and Shapal--the latter being an exotic ceramic which can be machined using standard tools. These materials were selected to replace plastic components which introduce impurities in the TPC during operation. Without plastic, the hope is that electron backgrounds will be reduced, leaving new opportunities for studying their origins and dependence on impurities. The SCGSR fellowship served as a springboard to help meet these objectives. Over the course of a year, the new components were designed, fabricated, and installed in XeNu. Following their installation, data was taken for use in a future study that will enable the electron background contributions from plastic components to be studied directly. In the interim, preliminary analysis results indicate that electron backgrounds with the new components are roughly 50% lower. This has established the efficacy of Shapal as a low-background replacement for plastic components where electrical and thermal stability are needed

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NuGraph2 with context-aware inputs: physics-inspired improvements in semantic segmentation

Graph neural networks have recently shown strong promise for event reconstruction tasks in Liquid Argon Time Projection Chambers, yet their performance remains limited for underrepresented classes of particles, such as Michel electrons. In this work, we investigate physics-informed strategies to improve semantic segmentation within the NuGraph2 architecture. We explore three complementary approaches: (i) enriching the input representation with context-aware features derived from detector geometry and track continuity, (ii) introducing auxiliary decoders to capture class-level correlations, and (iii) incorporating energy-based regularization terms motivated by Michel electron energy distributions. Experiments on MicroBooNE public datasets show that physics-inspired feature augmentation yields the largest gains, particularly boosting Michel electron precision and recall by disentangling overlapping latent space regions. In contrast, auxiliary decoders and energy-regularization terms provided limited improvements, partly due to the hit-level nature of NuGraph2, which lacks explicit particle- or event-level representations. Our findings highlight that embedding physics context directly into node-level inputs is more effective than imposing task-specific auxiliary losses, and suggest that future hierarchical architectures such as NuGraph3, with explicit particle- and event-level reasoning, will provide a more natural setting for advanced decoders and physics-based regularization. The code for this work is publicly available on Github at https://github.com/vitorgrizzi/nugraph_phys/tree/main_phys.

Other Experiments↗

Cryogenic Front-End ASICs for Low-Noise Readout of Charge Signals

This paper presents design details and measurement results of LArASIC, a front-end application specific integrated circuit (ASIC) designed for low-noise readout of charge signals generated in neutrino study experiments within liquid argon time projection chambers. LArASIC comprises of 16-channels of programmable charge amplification and pulse shaping stages that provide a voltage readout proportional to the input charge and was optimized for operation at liquid argon temperature, i.e., 89 K. The chip was fabricated in a 180 nm CMOS process. Measurements at liquid nitrogen temperature, i.e., 77 K, indicate that the channel outputs have high linearity (INL < 0.1%) within the operating range, an equivalent noise charge of 534 electrons for a peaking time of 1 µs and a detector capacitance of 150 pF, and a worst-case inter-channel cross-talk of 0.35%. The paper also presents design choices made in the process of migrating LArASIC to CHARMS, an ASIC to be fabricated in a 65 nm process that includes all features provided by LArASIC, along with additional digital programmability for improved robustness and flexibility. CHARMS is intended for use in future high-energy physics experiments that require high-resolution charge or light readout with shorter pulse peaking times.

47 OTHER INSTRUMENTATION↗

Physics at the MeV-Scale in Liquid Argon Time Projection Chambers

The liquid argon time projection chamber (LArTPC) is the detection technology chosen for several Fermilab-based neutrino experiments. This technology will be used in studies of neutrino cross-sections and oscillations, neutrinos from supernovae as well as a variety of studies of beyond the Standard Model physics. This thesis explores the use of these detectors to study MeV-scale activity. MeV-scale electrons arising from Compton scatters of deexcitation photons and photons from inelastic neutron scattering in neutrino-nucleus interactions are reconstructed using novel methods presented here. This work represents the first demonstration of MeV-scale physics capabilities in a LArTPC neutrino experiment as well as the first observation of neutrino-produced photons from nuclear de-excitation and inelastic neutron scattering. A search for millicharged particles, postulated by theories of beyond the standard model physics, is also performed using data from a LArTPC and the low-ener gy reconstruction techniques developed. The results set world-leading bounds on the parameter space of millicharged particles. The work in this thesis demonstrates that studies of MeV-scale activity and new physics are possible with LArTPC technology and provides the foundation for future LArTPC studies of low energy neutrinos and new physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron-antineutron oscillation sensitivity study at DUNE

The Deep Underground Neutrino Experiment (DUNE) aims to measure neutrino oscillations as well as search for beyond the standard model physics such as baryon number violating (BNV) processes. DUNE will use a 70 kt Liquid Argon Time Projection Chamber (LArTPC) located more than 1 km underground. A promising BNV process is neutron-antineutron oscillation ($n \rightarrow \bar{n}$) which, if discovered, would offer unique insight into the baryon asymmetry of the universe. We are developing a classification algorithm that separates $n \rightarrow \bar{n}$ events from major background atmospheric neutrino interactions using DUNE far detector simulations. We will perform the classification of signals and backgrounds by analyzing key features such as the multiplicity, isotropy, and kinematics of the reconstructed events. In the future, this algorithm can be used to obtain the sensitivity of the DUNE detectors to the neutron-antineutron oscillation lifetime.

Wheeler, Justin↗

ArCS: A Magnetized LArTPC in a Test Beam

Over the past few decades, Liquid Argon Time Projection Chambers (LArTPCs) have emerged as a central technology for rare-event detection, due to their calorimetric and imaging capabilities. Adding a magnetic field to LArTPCs would enable charge identification and momentum measurements via curvature. For neutrino experiments, this is crucial for wrong-sign neutrino rejection, electron/positron and electron/photon discrimination, and improved momentum reconstruction. The ArCS (Argon detector with Charge Separation) experiment at Fermilab's Test Beam Facility will place a 47 40 90 cm LArTPC inside a 0.7 T magnet to: (i) establish charge sign discrimination for electrons and positrons, (ii) reconstruct particle momenta via curvature, and (iii) determine the minimal magnetic field needed for these measurements. This poster will present the project status, with updates on installation and simulations of expected performance.

Cicogna, Giulia [Bologna U.]↗