Faster Test for Cable Seals

Vacuum-assisted immersion test is much faster than conventional atmospheric immersion tests of cable seals. Vacuum speeds removal of air, allowing its replacement by conductive salt solution in leaking specimens. Previously, 24-hour immersion was necessary to assure displacement of trapped air. Improved method takes only 10 minutes.

Shephard, A. T.↗

Study of the Thermal Physical Properties of Insulating Materials in A Titan Environment

Dragonfly is a planned rotorcraft mission that NASA/APL will be sending to Saturn’s moon Titan to study its chemistry. The Dragonfly Mass Spectrometer (DraMS) is a mass spectrometer that is being developed to identify different kinds of organic material that comprises Titan’s surface. The Cryogenic engineering team on DraMS is developing and interface between the room temperature rotorcraft body and the near-cryogenic temperatures of an onboard sample chamber, while minimizing the thermal leak to the Titan environment. As part of design process, the Cryogenic team has built a conductivity test rig for testing the thermophysical properties of candidate insulators, which includes Rohacell 31HF and hollowed 3D printed PEEK structures, at simulated Titan environmental conditions.

Thermal Conductivity↗

Test Analysis Correlation of the Single Stringer Bending Tests for the Space Shuttle ET-137 Intertank Stringer Crack Investigation

On November 5, 2010, Space Shuttle mission STS-133 was scrubbed due to a hydrogen leak at the Ground Umbilical Carrier Plate (GUCP). After the scrub, a crack in the foam thermal protection system (TPS) was observed on the External Tank (ET) near the interface between the liquid oxygen (LOX) tank and the Intertank. When the damaged foam was removed, two 9-in. long cracks were found on the feet of Intertank stringer S7-2, and the stringer failure was the cause of the TPS crack. An investigation was conducted to determine the root cause of the cracks, establish a remedy/repair for the stringers, and provide flight rationale for the damaged tank, ET-137. The Space Transportation System (STS) Super Lightweight ET (SLWT) is comprised of two propellant tanks (an aft liquid hydrogen (LH2) tank and a forward LOX tank) and an Intertank. The Intertank serves as the structural connection between the two propellant tanks and also functions to receive and distribute all thrust loads from the solid rocket boosters . The Intertank is a stiffened cylinder structure consisting of eight mechanically joined panels (two integrally-stiffened, machined thrust panels to react the booster loads and six stringer-stiffened skin panels). There are one main ring frame, four intermediate ring frames, and forward and aft flange chords that mate to the respective propellant tanks.. The skin/stringer panels utilize external hat-section stringers that are mechanically attached with rivets along most of their length and with specialty fasteners, such as GP Lockbolts and Hi-Loks, at the forward and aft ends where the stringers attach to the flange chords. During the STS-133 Intertank stringer crack investigation, cracks were found on a total of five stringers. All of the cracks were at the LOX end, in the feet of the stringers, and near the forward fasteners (GP Lockbolts). Video of tanking for the November 5 launch attempt was used to determine that the TPS failure, and thus the stringer failure, occurred as the LOX liquid level crossed the LOX tank / Intertank interface ring frame. Hence, cryogenically-induced displacements were suspected as a contributing cause of the stringer cracks. To study the behavior of Intertank stringers subjected to similar displacements, static load tests of individual stringers, colloquially known as "single stringer bending tests" were performed. Approximately thirty stringers were tested, many of which were cut from the partially completed Intertank for what would have been ET-139. In addition to the tests, finite element (FE) analyses of the test configuration were also performed. In this paper, the FE analyses and test-analysis correlation for stringer test S6-8 are presented. Stringer S6-8 is a "short chord" configuration with no doubler panels.

Phillips, Dawn R.↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. Window installation guidance for walls with continuous insulation (CI) is critical for continued market growth of this energy efficiency technology. This research project offers window manufacturers a starting point and a potential path toward developing installation instructions for windows over CI. The objectives of the research include evaluating the common method for installing windows in walls with CI, as well as establishing acceptance criteria for evaluating the performance of windows installed in walls with and without CI. The research measures: 1. The performance characteristics (e.g., water management, structural integrity) of windows in walls without CI. 2. The performance of different thicknesses and types of CI used in walls. 3. The performance of different types of window assemblies (e.g., double-hung windows, mulled double-hung windows, mulled casement windows, and slider windows) installed over CI. 4. The performance of window flange types (e.g., rigid mounting and less robust flanges) installed over CI. 5. Installing windows over CI using baseline installation instructions versus window manufacturer installation instructions. The project’s sequential testing protocol consists of the following: • A water penetration resistance testing adapted from two ASTM standards: E331 (uniform static air pressure in four steps) and E547 (cyclic static air pressure) • A temperature cycling adapted from ASTM E2264 Method B (convective hot air) • A service condition wind loading test adapted from ASTM E330 • A six-month vertical displacement observation phase prior to the structural performance testing • A final water penetration resistance test after vertical displacement observation • A structural performance test adapted from ASTM E330. Key research findings include: • The criterion for passing a water penetration resistance test is that there is no water overflowing at the interior face of the studs. If there is any bubbling or slight pooling of water at the sill, then it must recede after the pressure is removed. Excessive leakage and/or water leaking to the interior face of the framing around the window constitutes a failure. • All single double-hung windows installed directly to lumber or over oriented strand board passed all test protocols. • For most wall specimens, the test results showed that the use of foam sheathing did not affect the performance of the window for water leakage. • All wall specimens underwent temperature cycling. The results indicated that temperature cycling had little to no effect on windows installed over foam sheathing. • For wall specimens that underwent six-month vertical displacement monitoring, the results showed that windows installed over foam sheathing do not sag over time. • The single-hung and double-hung windows installed using window manufacturer installation instructions passed the structural performance test, compared to failures observed in windows that were installed using generic installation instructions. The generic and manufacturer installation methods differed on the following construction details: type of fasteners, fastening patterns on the flanges, and window shimming details. • Additional testing is required to determine methods to improve structural pressure performance of slider windows. Potential solutions that would require additional testing may include fastener spacing, different types of fasteners, masonry window clips, construction adhesive, foam sealant, stronger window flange material, and/or straps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development Fiber Optic Distributed System for Direct Detection of Subsurface Gases Leakages

Carbon, natural gas, and hydrogen gas storage is an emerging solution to safeguard us against pollution, support goals of negative carbon emission, and protect sources of renewable energy. Properly constructed storage wells provide a virtually impervious barrier to any unintended subsurface transmission. The ability to ensure the long-term integrity of such wells is vital to the success of any storage operation and be successful in the public eyes. Therefore, robust monitoring of any gas migration into the subsurface is highly sought. A fiber-optic distributed chemical sensor (DCS) enables monitoring of long-term well integrity along its depth, ensuring the success of any storage operation and bolsters public acceptance of the safety of the reservoir via leak early detection. The same technique can be applied to gas monitoring in pipeline networks and nuclear stockpile monitoring applications. Fiber based Raman spectroscopy enables DCS, as optical fibers can be deployed in virtually any environment and relay spectroscopic information over long distances back to the user. Hollow core fibers (HCF) make excellent DCSs as the air core of the fiber allows gas from the environment to diffuse into the core, which interacts with the laser signal that is carried in the air core. This work builds upon the previous LDRD project, Fiber Optic System for Direct Detection of Carbon Dioxide Leakage in Carbon Storage Wells (21-FS-003), in which the feasibility of Raman spectroscopy detection of Carbon Dioxide (CO2) in HCF detection was demonstrated. We mitigated the risk of this DCS technology by establishing and completing five objectives. The first objective was to model and optically characterize HCF uptake of CO2, establishing the relationship between HCF length, gas diffusion time, detectable gas concentration, and measured Raman intensity. In objective two, we developed a fiber core drilling recipe to enable additional diffusion ports in the fiber core and established a method for maintaining fiber strength and integrity post drilling. Objective three characterized the drilled fibers against the undrilled fibers, establishing the differences in the gas mechanics and optical properties and provided parameters to iterate the drilling process. In objective four, a fusion splicing technique was developed to join the HCF to conventional single-mode fibers, localizing the gas detection point at the drilled HCF hole, emulating a DCS. Lastly, objective five was the testing of the sensor in Edgar Mines at Colorado School of Mines on a CO2 pipeline with a simulated leak, to showcase the ability to detect CO2 leaks. This capstone result showed CO2 leak detection in < 10 minutes, raising the technology readiness level of HCF segments as deployable DCS.

organic↗

CCUS 2024, Interpreting the strain tensor Larry Murdoch Interpreting strain tensor data to characterize and monitor reservoirs for CO2 storage and other applications

Recent advances in instrumentation have made it feasible to measure the transient strain tensor caused by small changes in fluid volume or pressure in the subsurface and this has opened the door to new opportunities for characterization and monitoring during CCUS. We have demonstrated this method by deploying strainmeters at shallow depths (30 to 40m) and then conducting injection well tests in an underlying reservoir at 530m depth. The resulting data indicated that the horizontal strain at shallow strainmeters was tensile and the vertical strain was compressive. The radial strain was less than the horizontal strain, and the strain rates decreased from 100 nanostrain/day to roughly 10 ne/d over a few days (1 nanostrain = 1 part per billion strain). We then used the strain data to estimate reservoir properties, geometry and pressure through inversion of poroelastic forward models using both numerical and novel analytical methods. The average horizontal strain in the caprock resembles the transient pressure in the underlying reservoir and classic type-curve methods from transient well testing can be used for preliminary interpretations of strain data. We have developed fast, closed-form analytical solutions to a pressurized poroelastic inclusion and inhomogeneity in a half-space. Numerical models developed using finite element methods allow more details of the subsurface to be included in the inversion, but they require much longer run times and this makes inversion cumbersome using standard methods. We have developed an inversion approach that uses a proxy model created using machine learning to do most of the forward calculations. This approach markedly reduces the computational requirements and makes it feasible to use Bayesian inversion with large numerical models. Bayesian inversion is important because it provides predictions with uncertainties, which makes the results useful for decision making. We have shown with field tests and simulations that the strain tensor in the caprock is sensitive to pressure in the reservoir, reservoir properties and boundaries, and pressure in the caprock caused by leaks. These results indicate that measuring and interpreting the shallow strain tensor could be a valuable tool for both initial reservoir characterization efforts and long-term monitoring during CCUS. Recent advances in instrumentation have made it feasible to measure the transient strain tensor caused by small changes in fluid volume or pressure in the subsurface and our objective was to evaluate opportunities for strain monitoring during characterization and monitoring for CCUS. Our approach was to deploy strainmeters at shallow depths (30 to 40m) and then conduct injection well tests in an underlying reservoir at 530m depth. The results indicate that the horizontal strain at shallow strainmeters was tensile and the vertical strain was compressive. The radial strain was less than the horizontal strain, and the strain rates decreased from 100 nanostrain/day to roughly 10 ne/d over a few days (1 nanostrain = 1 part per billion strain). We then used the strain data to estimate reservoir properties, geometry and pressure through inversion of poroelastic forward models using both numerical and novel analytical methods. The average horizontal strain in the caprock resembles the transient pressure in the underlying reservoir and classic type-curve methods from transient well testing can be used for preliminary interpretations of strain data. We have developed fast, closed-form analytical solutions to a pressurized poroelastic inclusion and inhomogeneity in a half-space. Numerical models developed using finite element methods allow more details of the subsurface to be included in the inversion, but they require much longer run times and this makes inversion cumbersome using standard methods. We have developed an inversion approach that uses a proxy model created using machine learning to do most of the forward calculations. This approach markedly reduces the computational requirements and makes it feasible to use Bayesian inversion with large numerical models. Bayesian inversion is important because it provides predictions with uncertainties, which makes the results useful for decision making. In conclusion, we have shown with field tests and simulations that the strain tensor in the caprock is sensitive to pressure in the reservoir, reservoir properties and boundaries, and pressure in the caprock caused by leaks. These results indicate that measuring and interpreting the shallow strain tensor could be a valuable tool for both initial reservoir characterization efforts and long-term monitoring during CCUS.

Murdoch, Larry↗

Structural Dynamic Assessment of the GN2 Piping System for NASA's New and Powerful Reverberant Acoustic Test Facility

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has led the design and build of the new world-class vibroacoustic test capabilities at the NASA GRC's Plum Brook Station in Sandusky, Ohio, USA from 2007 to 2011. SAIC-Benham has completed construction of a new reverberant acoustic test facility to support the future testing needs of NASA's space exploration program and commercial customers. The large Reverberant Acoustic Test Facility (RATF) is approximately 101,000 cubic feet in volume and was designed to operate at a maximum empty chamber acoustic overall sound pressure level (OASPL) of 163 dB. This combination of size and acoustic power is unprecedented amongst the world s known active reverberant acoustic test facilities. Initial checkout acoustic testing was performed on March 2011 by SAIC-Benham at test levels up to 161 dB OASPL. During testing, several branches of the gaseous nitrogen (GN2) piping system, which supply the fluid to the noise generating acoustic modulators, failed at their T-junctions connecting the 12 in. supply line to their respective 4 in. branch lines. The problem was initially detected when the oxygen sensors in the horn room indicated a lower than expected oxygen level from which was inferred GN2 leaks in the piping system. In subsequent follow up inspections, cracks were identified in the failed T-junction connections through non-destructive evaluation testing. Through structural dynamic modeling of the piping system, the root cause of the T-junction connection failures was determined. The structural dynamic assessment identified several possible corrective design improvements to the horn room piping system. The effectiveness of the chosen design repairs were subsequently evaluated in September 2011 during acoustic verification testing to 161 dB OASPL.

McNelis, Mark E.↗

Air-to-Liquid Heat Exchanger Fabricated Using Deposition-Based Additive Manufacturing Processes

Abstract This work describes the use of deposition-based additive manufacturing (AM) techniques to fabricate air-cooled, two-fluid heat exchangers. The project focused on a Heating, Ventilation and Air Conditioning application and used an industry-standard copper/aluminum heat exchanger manufactured with conventional technology as the basis for assessing performance. The manufacturing constraints associated with using deposition-based AM technology for this application include the need for a continuous tool path within each build layer that allows uninterrupted extrusion and therefore defect-free water channel walls that correspond to a reliably leak-tight heat exchanger. A geometry that respects these constraints was developed, simulated, optimized and finally manufactured and tested. The material used was a composite of polymer filled with conductive flakes in order to provide high conductivity in the direction that heat must flow in this heat exchanger, across the wall separating the fluids. The measured performance for several test coupons matched the predicted performance and the test coupons exhibited performance that approach and in some cases exceeds conventional technology

Engineering↗

Apollo 14 mission food preparation unit leakage

A bubble of water collected on the delivery probe of the food preparation unit after hot water was dispensed by the Apollo 14 crew. Postflight tests showed that dimensional interference between the cylinder and the piston at hot water temperatures produced the apparent leak by causing erratic and slow stroke time of the valve assembly.

Source record↗

Development of a General Method for Determining Leak Rates from Limiting Enclosures

This paper discusses the development of a general method for the determination of very low leak rates from limiting enclosures. There are many methods that can be used to detect and repair leaks from enclosures. Many methods have also been proposed that allow the estimation of actual leak rates, usually expressed as enclosure volume turnover. The proposed method combines measurements of the state variables (pressure, temperature, and volume) as well as the change in the concentration of a tracer gas to estimate the leak rate. The method was applied to the containment enclosure of the Engineering Development Unit of the CELSS Test Facility, currently undergoing testing at the NASA Ames Research Center.

Zografos, A. I.↗

Software engineering to sustain a high-performance computing scientific application: QMCPACK

We provide an overview of the software engineering efforts and their impact in QMCPACK, a production-level ab-initio Quantum MonteCarlo open-source code targeting high-performance computing (HPC) systems. Aspects included are: (i) strategic expansion ofcontinuous integration (CI) targeting CPU, using GitHub Actions runners, and graphics processing units (GPU) in pre-exascalesystems, using self-hosted hardware; (ii) incremental reduction of memory leaks using sanitizers, (iii) incorporation of Dockercontainers for CI and reproducibility, and (iv) refactoring efforts to improve maintainability, testing coverage, and memory lifetime management. We quantify the value of these improvements by providing metrics to illustrate the shift towards a predictive, rather than reactive, sustainable maintenance approach. Our goal, in documenting the impact of these efforts on QMCPACK, is to contribute to the body of knowledge on the importance of research software engineering (RSE) for the sustainability of community HPC codes and scientific discovery at scale.

Godoy, William↗

Device for steam cladding oxidation testing at TREAT

To compare the chemical degradation of conventional zirconium alloy (Zry) cladding to advance silicon carbide (SiC) cladding in a post loss of coolant accident (LOCA) environment, new nuclear testing capabilities are necessary. The Transient Reactor Test (TREAT) Facility at Idaho National Laboratory (INL) has matured its transient fuel testing capabilities since its 2017 restart. The most recent experiment architecture is the Transient Water Irradiation System in TREAT (TWIST), which is designed to support qualification of accident tolerant fuels in light water reactors. INL has designed and analyzed a natural circulation steam flow modification for TWIST to produce prototypic conditions of cladding oxidation. The in-situ device will be electrically heated to drive natural circulation. Moreover, the SiC cladding requires heating above 1700 °C to observe failure, thus internal prototypic nuclear heating with radiation effects will be used. Thermal hydraulic analysis with RELAP5-3D (Reactor Excursion and Leak Analysis Program) estimated steam fluxes greater than 50 mg cm −2 s −1 can be achieved. These fluxes are adequate to test Zry cladding according to draft regulatory guides and to test SiC cladding according to past experiments.

Oxidation↗

Maximum likelihood failure detection techniques applied to the shuttle orbiter reaction control subsystem

A technique for on-board detection and identification of hard failures and leaks of the shuttle orbiter reaction control subsystem jets, during the orbital flight phase, is presented. The method uses gimbal angle and linear accelerometer measurements from the orbiter inertial measurement unit and requires no additional hardware. Extended Kalman filters with residual traps are employed for state estimation, and generalized likelihood ratio tests for jet failure identification. Rigid body simulation results indicate identification times of less than 2 seconds for hard jet failures and less than 70 seconds for jet leaks.

Deckert, J. C.↗

Numerical Modeling, Thermomechanical Testing, and NDE Procedures for Prediction of Microcracking Induced Permeability of Cryogenic Composites

Reusable Space Vehicles will include light cryogenic composite fuel tanks that must not leak excessively even after multiple launches. Damage in cryogenic composite fuel tanks induced during manufacturing and advanced by thermomechanical cycling can accelerate leakage of the propellant. Whether the leakage exceeds tolerable levels depends on many factors, including pressure gradients, microcrack density, other damage such as delamination, connectivity of the cracks, residual stresses from manufacture, service-induced stresses from thermal and mechanical loads, and composite lay-up. Although it is critical to experimentally characterize permeability during various thermal and mechanical load histories, optimal design depends on having analytical models that can predict the effect of various parameters on performance. Our broad goal is to develop such models that are experimentally validated by destructive and non-destructive evaluation means.

Noh, Jae↗

Ground Operations Demonstration Unit for Liquid Hydrogen Initial Test Results

NASA operations for handling cryogens in ground support equipment have not changed substantially in 50 years, despite major technology advances in the field of cryogenics. NASA loses approximately 50% of the hydrogen purchased because of a continuous heat leak into ground and flight vessels, transient chill down of warm cryogenic equipment, liquid bleeds, and vent losses. NASA Kennedy Space Center (KSC) needs to develop energy-efficient cryogenic ground systems to minimize propellant losses, simplify operations, and reduce cost associated with hydrogen usage. The GODU LH2 project has designed, assembled, and started testing of a prototype storage and distribution system for liquid hydrogen that represents an advanced end-to-end cryogenic propellant system for a ground launch complex. The project has multiple objectives including zero loss storage and transfer, liquefaction of gaseous hydrogen, and densification of liquid hydrogen. The system is unique because it uses an integrated refrigeration and storage system (IRAS) to control the state of the fluid. This paper will present and discuss the results of the initial phase of testing of the GODU LH2 system.

liquefaction↗

Zero-Boil-Off Tank (ZBOT) Experiment: Ground-Based Validation of Self-Pressurization and Pressure Control Two-Phase CFD Model

Integral to all phases of NASA's projected space and planetary expeditions is affordable and reliable cryogenic fluid storage for use in propellant or life support systems. Cryogen vaporization due to heat leaks into the tank from its surroundings and support structure can cause self-pressurization relieved through venting. This has led to a desire to develop innovative pressure control designs based on mixing of the bulk tank fluid together with some form of active or passive cooling to allow storage of the cryogenic fluid with zero or reduced boil-off. The Zero-Boil-Off Tank (ZBOT) Experiments are a series of small scale tank pressurization and pressure control experiments aboard the International Space Station (ISS) that use a transparent volatile simulant fluid in a transparent sealed tank to delineate various fundamental fluid flow, heat and mass transport, and phase change phenomena that control storage tank pressurization and pressure control in microgravity. The hardware for ZBOT-1 flew to ISS on the OA-7 flight in April 2017 and operations are planned to begin in September 2017, encompassing more than 90 tests. This paper presents preliminary results from ZBOT's ground-based research delineating both pressurization and pressure reduction trends in the sealed test tank. Tank self-pressurization tests are conducted under three modes: VJ heating, strip heating and simultaneous VJ and strip heating in attempt to simulate heat leaks from the environment, the support structure and both. The jet mixing pressure control studies are performed either from an elevated uniform temperature condition or from thermally stratified conditions following a self-pressurization run. Jet flow rates are varied from 2-25 cm/s spanning a range of jet Re number in laminar, transitional, and turbulent regimes and a range of Weber numbers covering no ullage penetration, partial penetration and complete ullage penetration and break-up (only in microgravity). Numerical prediction of a two-phase CFD model are compared to experimental 1g results to both validate the model and also indicate the effect of the residual non-condensable gas on evolution of pressure and temperature distributions in the tank during pressurization and pressure control.

microgravity evaporation condensatio↗

Environmental projects. Volume 2: Underground storage tanks compliance program

Six large parabolic dish antennas are located at the Goldstone Deep Space Communications Complex north of Barstow, California. As a large-scale facility located in a remote, isolated desert region, the GDSCC operations require numerous on-site storage facilities for gasoline, diesel and hydraulic oil. These essential fluids are stored in underground storage tanks (USTs). Because USTs may develop leaks with the resultant seepage of their hazardous contents into the surrounding soil, local, State and Federal authorities have adopted stringent regulations for the testing and maintenance of USTs. Under the supervision of JPL's Office of Telecommunications and Data Acquisition, a year-long program has brought 27 USTs at the Goldstone Complex into compliance with Federal, State of California and County of San Bernadino regulations. Of these 27 USTs, 15 are operating today, 11 have been temporary closed down, and 1 abandoned in place. In 1989, the 15 USTs now operating at the Goldstone DSCC will be replaced either by modern, double-walled USTs equipped with automatic sensors for leak detection, or by above ground storage tanks. The 11 inactivated USTs are to be excavated, removed and disposed of according to regulation.

Kushner, L.↗

Test results of a Stirling engine utilizing heat exchanger modules with an integral heat pipe

The Heat Pipe Stirling Engine (HP-1000), a free-piston Stirling engine incorporating three heat exchanger modules, each having a sodium filled heat pipe, has been tested at the NASA-Lewis Research Center as part of the Civil Space Technology Initiative (CSTI). The heat exchanger modules were designed to reduce the number of potential flow leak paths in the heat exchanger assembly and incorporate a heat pipe as the link between the heat source and the engine. An existing RE-1000 free-piston Stirling engine was modified to operate using the heat exchanger modules. This paper describes heat exchanger module and engine performance during baseline testing. Condenser temperature profiles, brake power, and efficiency are presented and discussed.

Skupinski, Robert C.↗