Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Excalibur: A Nonparametric, Hierarchical Wavelength Calibration Method for a Precision Spectrograph

Excalibur is a nonparametric, hierarchical framework for precision wavelength calibration of spectrographs. It is designed with the needs of extreme-precision radial-velocity (EPRV) instruments in mind, which require calibration or stabilization to better than 10{sup −4} pixels. Instruments vary along only a few dominant degrees of freedom, especially EPRV instruments that feature highly stabilized optical systems and detectors. Excalibur takes advantage of this property by using all calibration data to construct a low-dimensional representation of all accessible calibration states for an instrument. Excalibur also takes advantage of laser-frequency combs or etalons, which generate a dense set of stable calibration points. This density permits the use of a nonparametric wavelength solution that can adapt to any instrument or detector oddities better than parametric models, such as a polynomial. We demonstrate the success of this method with data from the Extreme Precision Spectrograph (EXPRES), which uses a laser-frequency comb. When wavelengths are assigned to laser comb lines using excalibur, the rms of the residuals is about one-fifth that of wavelengths assigned using polynomial fits to individual exposures. Radial-velocity measurements of HD 34411 show a reduction in rms scatter over a 10 month time baseline from 1.17 to 1.05 m s{sup −1}.

47 OTHER INSTRUMENTATION↗

Interleaved dual-species arrays of single atoms using a passive optical element and one trapping laser

We demonstrate trapping of individual rubidium (Rb) and cesium (Cs) atoms in an interleaved array of bright tweezers and dark bottle-beam traps, using a microfabricated optical element illuminated by a single-laser beam and a 4f system with spatial filtering. Our approach exploits the opposite-sign dynamic polarizabilities of Rb and Cs, ensuring that each species is exclusively trapped in either bright or dark sites. The passive optical mask creates optimal trap depths for both species using three transmittance levels while minimizing the optical phase difference, implemented using a variable-thickness absorbing layer of amorphous germanium. This trapping architecture achieves atom loading rates close to 50% while reducing system complexity compared to conventional methods using active optoelectronic components and/or multiple-laser wavelengths.

Fang, Chengyu [Univ. of Wisconsin, Madison, WI (Un↗

A formaldehyde and nitrogen dioxide toxics monitor for environmental justice

DOE’s Integrated Field Laboratories (IFLs) require a vast array of measurements to measure urban air quality. Nitrogen dioxide (NO2) and formaldehyde (HCHO) are ubiquitous pollutants with numerous sources, most notably vehicle exhaust. High-spatial density measurements are critical to understanding how certain neighborhoods are more adversely impacted by pollutants. This report describes the results of a Phase I SBIR project to develop and demonstrate a rapid, affordable, low-power monitor to provide high spatial resolution mobile measurements of formaldehyde and nitrogen dioxide at street-level, where people live and walk. The spatial density will be achieved via rapid measurements on a mobile platform. This sensor will quantify spatial disparities in cities of the toxics, HCHO and NO2, as well as carbon monoxide and carbon dioxide for better source identification. These species are detected in the mid infrared by laser absorption spectroscopy, and fiberoptics are used. Tasks accomplished include identification and testing of the appropriate spectroscopic regions; coupling of laser light into a fiberoptic system; development of software to control miniature electronics to scan and control two lasers simultaneously; coupling of the mid infrared fiber into a multipass cell for enhanced pathlength and sensitivity; characterization of sources of instrument noise; and design work for a Phase II prototype.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancements of On-Line Monitoring and Real-Time Characterization of Actual Low-Level Hanford Tank-Waste Samples

Waste and process stream characterization is essential to the safe, efficient, and cost-effective processing of Hanford Site materials. The demand for materials characterization including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward Hanford waste treatment and immobilization. Our past work has applied Raman on-line monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105 and has demonstrated the quantitative measurement of nine analytes within this waste. To demonstrate broader applicability, this method has now been expanded to waste from two additional Hanford tanks, AW-102 and AP-107, and the offgas condensate from lab-scale melter runs of actual-tank waste feeds. To enhance the performance of the Raman method, instruments with various excitation wavelengths were compared, since it is known that the Raman response is enhanced by shorter wavelength excitation. The laser excitations for the three systems tested were 404 nm, 532 nm, and 671 nm. In addition to laser wavelength selection, the laser power, measurement integration times, and signal averaging techniques were also investigated to determine their effect on detection limits for oxy-anion analytes within tank wastes. These advancements in Raman capability are compared with past standards and will be presented.

Bryan, Samuel A.↗

Self-compression of laser pulses in a discrete medium

Using the discrete nonlinear Schrödinger equation, we study the laser radiation self-action dynamics in a nanostructured waveguide system. It is shown that for a laser pulse energy exceeding the critical value, the nonlinear evolution of the wave field markedly differs from the corresponding process in a continuous medium. While the pulse propagates in a discrete medium, its length decreases to values comparable to the scale of the structure and the velocity decreases to zero. The system parameters are determined at which the wave field after the laser pulse termination begins to propagate in the opposite direction in a compressed form. The process of slowing down and stopping the pulse is accompanied by strong radiation losses, so that about a third of the energy of the initial field distribution remains in the final compressed state. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultra-High-Sensitivity Aerosol Spectrometer (UHSAS) Instrument Handbook

The Ultra-High-Sensitivity Aerosol Spectrometer (UHSAS) (Figure 1) is an optical-scattering, laser-based aerosol particle spectrometer system for sizing particles in the 60 to 1000 nanometer (nm) range [1–3]. The instrument counts particles in up to 100 user-specified sizing bins. The instrument’s laser illuminates particles, which scatter light. The system captures the peak light signals that are generated. These signals are used for particle sizing, since the amount of light scattered correlates strongly with particle size.

54 ENVIRONMENTAL SCIENCES↗

Laser beam pointing stabilization using analog position-sensitive diodes

Laser wire scanners have been used for ion beam profile and emittance measurements at the Spallation Neutron Source linear accelerator. Due to propagation distances exceeding 100 m, reliable measurements require laser beam stabilization, previously accomplished with a feedback control loop using a digital camera as a position sensor [Hardin et al., Opt. Express 19, 2874 (2011)]. Here, this paper presents an upgraded pointing stabilization system utilizing analog position-sensitive diodes (PSDs) as the position detector, optimized with an optical diffuser. The new system significantly surpasses the previous system by offering an order-of-magnitude improvement in radiation tolerance and a bandwidth limited only by the burst repetition rate of the laser beam. Operating with a 60-Hz burst mode laser, the new system effectively suppresses laser beam drifts up to 30 Hz, compared to the previous system’s 4 Hz limit. In addition, the amplitude of spectral components below 0.1 Hz was reduced by a factor of more than 100, which is over seven times greater than was achieved by the previous system.

Data acquisition↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High power actively Q-switched downhole LIBS analysis systems

An actively Q-switched laser induced breakdown spectroscopy (LIBS) probe, utilizing an optical fiber, a pump beam transmitted through the optical fiber, a coupler, and a lens for collimating the pump beam. The actively Q-switched laser, coupled to a sensor which provides information to a computer that controls a high voltage pulser providing a pulse to a Pockels cell located within the laser which can selectively cause the laser to pulse, resulting in high energy pulses and a second lens for focusing the output pulse such that it creates a plasma or spark. The light from the spark is captured and directed back through an optical system to remote equipment for elemental and/or molecular analysis.

McIntyre, Dustin Langdon↗

Probing C60 Fullerenes from within Using Free Electron Lasers

Fullerenes, such as C60, are ideal systems to investigate energy redistribution following substantial excitation. Ultra-short and ultra-intense free electron lasers (FELs) have allowed molecular research in a new photon energy regime. FELs have allowed the study of the response of fullerenes to X-rays, which includes femtosecond multi-photon processes, as well as time-resolved ionization and fragmentation dynamics. This perspective: (1) provides a general introduction relevant to C60 research using photon sources, (2) reports on two specific X-ray FEL-based photoionization investigations of C60, at two different FEL fluences, one static and one time-resolved, and (3) offers a brief analysis and recommendations for future research.

Berrah, Nora (ORCID:0000000332311164)↗

Cavity-assisted magnetization switching in a quantum spin-phonon chain

Néel order switching in antiferromagnets has typically required intense optical driving, leading to substantial heating and limited efficiency. By placing antiferromagnets inside a terahertz-driven optical cavity, we propose a multi-particle mechanism for Néel order switching that benefits from reduced heating. Our analysis reveals that phonons are indispensable to this mechanism. A driven cavity mode couples to a spin-phonon chain, with all excitations dissipating energy through external baths. Mean-field analysis shows that cavity photons induce sublattice spin-density imbalance—an intrinsic symmetry-breaking effect absent without the cavity. Contrary to known (1–10 V/nm) laser fields required to switch the Néel order, our mechanism enables switching at remarkably low laser fields (1–5 V/μm), selectively targeting low-energy and perpendicular magnon modes. By virtue of the suppressed heating, the switching remains highly tunable through laser fluence, damping, and photon loss, establishing a low-dissipation route toward cavity-assisted opto-spintronics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pacific Marine Energy Center Laser Doppler Velocimetry Commissioning

First commissioning data for the new laser doppler velocimetry (LDV) system that will be used at the Tyler Flume at the University of Washington. The LDV system can measure three components of velocity at a point. For this dataset the three components were operated in non-coincident mode and data were acquired at the center of the empty facility. Comparisons of freestream turbulence were made with a Vectrino slightly upstream of the LDV measurement location.

16 TIDAL AND WAVE POWER↗

Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗

Application of emerging monitoring techniques at the Illinois Basin – Decatur Project

The Illinois Basin – Decatur Project is a large-scale carbon capture and storage demonstration project located in Decatur, Illinois, USA. In this project, one million metric tons of carbon dioxide (CO 2 ) was captured from an ethanol production facility and successfully injected into a deep saline reservoir over a period of three years. The scale of this project presented an opportunity to explore emerging technologies for effective long-term monitoring of the carbon capture and storage site. This research documents the application of three emerging monitoring techniques: (1) a prototype “open-path” sensor, a method of continuously monitoring atmospheric CO 2 by applying tunable diode laser absorption spectroscopy to provide a warning system for personnel safety along pipelines and at wellheads; (2) the Greenhouse Gas Laser Imaging Tomography Experiment (GreenLITE), an automated system for measuring two-dimensional spatial distribution of atmospheric CO 2 concentrations; and (3) periodic aerial imagery, a method of documenting surface-vegetation dynamics to detect vegetative responses to CO 2 leaks. The objective of this work was to assess the advantages and limitations of these monitoring techniques and quantify their reliability over an extended deployment at an active industrial site. These results will aid in determining viability of long-term monitoring on a commercial scale.

42 ENGINEERING↗

Depth-Resolved Lithiated Gradients in Pristine and Laser-Ablated Anodes During Fast Charging

Laser ablating 3D electrode microstructures is a technique to improve Li-ion battery fast-charge performance. This technique has been theoretically proposed and electrochemically validated previously in the literature. The fundamental principle underlying laser ablation is that the ablated features reduce Li-ion transport pathways, improving access to the electrode active material near the current collector. This, in turn, promotes more homogeneous electrode utilization. The present study seeks to directly affirm the physics attributed to laser ablation using operando high-speed synchrotron X-ray diffraction. In this study, depth-resolved graphite lithiation gradients are measured operando during high-rate (15 min) charging. The depth-resolved lithiation dynamics of both ablated and non-ablated anodes are compared. The results highlight that the laser-ablated graphite electrode has notably more homogeneous utilization as compared to the non-ablated electrode. Additionally, the ablated electrode has a significant delay in reaching the maximum graphite lithiation at the separator, indicating less propensity for lithium plating. During low rate delithiation/discharge (2 hr), the two cells' lithiation gradients converge. Notably, a calibrated physics-based electrochemical model accurately reflects experimental findings, suggesting the potential to use pseudo-4D models not only to optimize laser ablation parameters in fast-charge capable electrodes but also to guide fast charging protocols that avoid lithium plating.

25 ENERGY STORAGE↗

Development of spinning-disk solid sample delivery system for high-repetition rate x-ray free electron laser experiments

X-ray free-electron lasers (XFELs) deliver intense x-ray pulses that destroy the sample in a single shot by a Coulomb explosion. Experiments using XFEL pulse trains or the new generation of high-repetition rate XFELs require rapid sample replacement beyond those provided by the systems now used at low repletion-rate XFELs. We describe the development and characterization of a system based on a spinning disk to continuously deliver a solid sample into an XFEL interaction point at very high speeds. We tested our system at the Linac Coherent Light Source and European XFEL hard x-ray nano-focus instruments, employing it to deliver a 25 μm copper foil sample, which can be used as a gain medium for stimulated x-ray emission for the proposed x-ray laser oscillator.

47 OTHER INSTRUMENTATION↗