Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lab test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS

At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EPA and Idaho National Laboratory create first of its scale

Advancing the science and engineering of decontaminating water distribution systems and safely disposing of high-volumes of contaminated water are high priorities for the EPA. To help address these science gaps, EPA homeland security researchers have developed the first-of-its-scale Water Security Test Bed (WSTB). Water is an important component of everyday life. We rely on safe, clean water for our health and the health of the environment. Protecting this vital resource is critical to living safely and securely. The U.S. Environmental Protection Agency is responsible for working with water utilities to protect water systems from contamination and to clean up systems that become contaminated. Purposeful or inadvertent distribution system contamination can result in large amounts of infrastructure and water that must be cleaned. Water distribution systems contamination can be caused by, for example, natural disasters such as Superstorm Sandy or by individuals hoping to cause harm. The WSTB, constructed at the Department of Energy’s (DOE) Idaho National Laboratory, replicates a section of a typical municipal drinking water system including a piping system with roughly 445 feet of pipe and two fire hydrants laid out in an “L” shape using 40-year-old, eight-inch cement mortar lined, ductile iron pipes, excavated after twenty years of use for water conveyance. Researchers built the WSTB above ground for easy access during experiments, and to facilitate fast leak detection. Over the next several years, EPA and partner researchers will conduct experiments using simulants of various biological, chemical, and radioactive materials that simulate high toxic versions of these agents. At this “full” sized system, researchers will demonstrate approaches to contamination detection, sensor and model testing, infrastructure decontamination, water treatment and cyber testing developed at lab and pilot scale. Researchers are also able to verify if laboratory results that were effective in controlled conditions are as effective in full-scale testing. Having the ability to conduct bench scale studies in a real world setting can help address specific research gaps, and help water researchers understand conditions in which real world drinking water systems operate.

54 ENVIRONMENTAL SCIENCES↗

Manufacturing the Harmonic Kicker Cavity Prototype for the Electron-Ion Collider

High-bunch-frequency beam-separation schemes, such as the injection scheme proposed for the Rapid Cycling Synchrotron at the Electron-Ion Collider, demand rise and fall times an order of magnitude below what can realistically be accomplished with a stripline kicker. Nanosecond-time-scale kick waveforms can instead be obtained by Fourier synthesis in a harmonically resonant quarter-wave radio-frequency cavity which is optimized for high shunt impedance. Originally developed for the Jefferson Lab Electron-Ion Collider (JLEIC) Circulator Cooler Ring, a hypothetical 11-pass ring driven by an energy-recovery linac at Jefferson Lab, our high-power prototype of such a harmonic kicker cavity, which operates at five modes at the same time, will demonstrate the viability of this concept with a beam test at Jefferson Lab. As the geometry of the cavity, tight mechanical tolerances, and number of ports complicate the design and manufacturing process, special care must be given to the order of the manufacturing steps. We present our experiences with the manufacturability of the present design, lessons learned, and first RF test results from the prototype.

Overstreet, S. A.↗

Manufacturing the Harmonic Kicker Cavity Prototype for the Electron-Ion Collider

High-bunch-frequency beam-separation schemes, such as the injection scheme proposed for the Rapid Cycling Synchrotron at the Electron-Ion Collider, demand rise and fall times an order of magnitude below what can realistically be accomplished with a stripline kicker. Nanosecond-time-scale kick waveforms can instead be obtained by Fourier synthesis in a harmonically resonant quarter-wave radio-frequency cavity which is optimized for high shunt impedance. Originally developed for the Jefferson Lab Electron-Ion Collider (JLEIC) Circulator Cooler Ring, a hypothetical 11-pass ring driven by an energy-recovery linac at Jefferson Lab, our high-power prototype of such a harmonic kicker cavity, which operates at five modes at the same time, will demonstrate the viability of this concept with a beam test at Jefferson Lab. As the geometry of the cavity, tight mechanical tolerances, and number of ports complicate the design and manufacturing process, special care must be given to the order of the manufacturing steps. We present our experiences with the manufacturability of the present design, lessons learned, and first RF test results from the prototype.

Overstreet, S. A.↗

Experimental Study of the 3 He and Neutron Spin Structure at Low Q 2 and The Upgrade of the JLab Polarized 3 He Target

In the scattering process off a nuclear or nucleon target, the Gerasimov-Drell-Hearn (GDH) sum rule for real photons (Q 2 =0 where Q 2 &equiv; -q 2 with q the photon's 4-momentum) relates static properties of the target particle's ground state to dynamic properties of all its excited states. On the other side of the Q 2 spectrum, the Bjorken sum rule holds in the Bjorken limit Q 2 &rarr; &infin;. Bjorken sum rule relates the final structure functions of the proton and neutron to the nucleon axial coupling constant in weak decay. These two sum rules belong to domains where calculations are achievable but use different degrees of freedom: hadronic degrees of freedom at low Q 2 versus partonic degrees of freedom at intermediate Q 2 . Meanwhile, different methods have been used to connect the two sum rules at finite Q 2 values: Chiral Perturbation Theory is used to expand the GDH sum rule while Operator Product Expansion is used to expand the Bjorken sum rule. In recent decades, improvements in polarized beam and polarized target techniques have made it possible to test theoretical predictions in the intermediate Q 2 region. During the Jefferson Lab (JLab) Hall A E97110 experiment, a precise measurement of polarized cross sections was performed at 0.02 < Q 2 < 0.3 GeV 2 using a polarized 3 He target as an effective polarized neutron target. The measured data allowed us to test predictions of Chiral Perturbation Theory at very low Q 2 . Furthermore, an extrapolation to the real photon point Q 2 =0 tests the GDH sum rule on the neutron. In order to reach the small angles necessary for the low Q 2 range, a new septum magnet was installed in Hall A for this experiment. Unfortunately, the magnet was mis-wired during initial running. There were therefore two periods for this experiment: the first period had the defective magnet due to mis-wiring; while in the second period, the magnet had been fixed and was working properly. The cross sections and the asymmetries for the first period must be extracted using a difficult and unusual method employing focal plane variables in the spectrometer. In the work described in this thesis, the target-plane and focal-plane method will be established first and confirmed by elastic scattering cross section measurements from carbon foil and 3 He targets. Cross sections and asymmetries of inelastic scattering were then extracted using the same method, which constitute the main physics results of this thesis. Preliminary results on ITT , the integral of the polarized cross section, were also extracted and are presented in this thesis. In addition to the data analysis of E97110, this thesis includes instrumentation work performed on the polarized 3 He target at JLab. For the 12 GeV program of JLab, the polarized 3 He target is being upgraded to satisfy new experimental requirements. The new target is a convection-based cell with two transfer tubes rather than a single transfer tube as in the former 6 GeV design. The first stage of the target upgrade aims to produce a 40 cm long, 10 amg target that can withstand 30 &mu;A of electron beam current with an in-beam polarization of 55%, doubling the figure-of-merit from the 6 GeV time. Several studies were conducted at the Test Lab of JLab on the new convection cell. Work and improvement done on the Pulse Nuclear Magnetic Resonance (NMR) polarimetry and its test results will be presented. As this thesis is written, the target is being installed in Hall C of JLab in preparation for a 6-month long running from November 2019 to May 2020.

Ton, Nguyen↗

High-Temperature Modal Survey of a Hot-Structure Control Surface

Ground vibration tests or modal surveys are routinely conducted for supporting flutter analysis for subsonic and supersonic vehicles; however, for hypersonic vehicle applications, thermoelastic vibration testing techniques are not well established and are not routinely performed for supporting hypersonic flutter analysis. New high-temperature material systems, fabrication technologies and high-temperature sensors expand the opportunities to develop advanced techniques for performing ground vibration tests at elevated temperatures. High-temperature materials have the unique property of increasing in stiffness when heated. When these materials are incorporated into a hot-structure, which includes metallic components that decrease in stiffness with increasing temperature, the interaction between the two materials systems needs to be understood because that interaction could ultimately affect the hypersonic flutter analysis. Performing a high-temperature modal survey will expand the research database for hypersonics and will help build upon the understanding of the dual material interaction. This paper will discuss the vibration testing of the Carbon-Silicon Carbide Ruddervator Subcomponent Test Article which is a truncated version of the full-scale X-37 hot-structure control surface. In order to define the modal characteristics of the test article during the elevated-temperature modal survey, two series of room-temperature modal test configurations had to be performed. The room-temperature test series included one with the test article suspended from a bungee cord (free-free) and the second with it mounted on the strongback (fixed boundary condition) in NASA Dryden's Flight Loads Lab large nitrogen test chamber.

Spivey, Natalie Dawn↗

Initial ASME code rule analysis on Simple and Full assessment

ASME & ASTM codes present simple and full assessment methodologies to qualify nuclear grade graphite components. This report explains the theory behind the statistical portion of the codes and describes the issues discussed in a 2020 workshop in the simple assessment, as well as the full assessment. The methodology for the full assessment was developed by Hindley []. He used a validation methodology to match the experimental average failure load of test specimens from several geometries to the calculated 50% POF load to tune the grouping criteria parameters based on an RMSE penalty function. The grouping criteria consists of a minimum volume to satisfy the weakest link theory of the Weibull distribution and a minimum stress range parameter. Hindley’s work found a minimum link volume of 10 times the grain size and a stress range parameter of 7% [satisfy the validation requirements. Several studies found that the link volume of 10 times the grain size was not satisfactory for the volume grouping criteria for graphite grades with fine grains. ASME 2021 code adopted a new volume grouping criteria based on fracture toughness for calculation of the process zone volume. However, errors were found in the ASME 2021 code process zone volume equation and the question is now open as to what volume grouping criteria is satisfactory. This report presents results from sensitivity studies that were done to evaluate the volume grouping criteria effect on the full assessment POF. This report also presents results from sensitivity studies on other aspects of the code that affect the POF, the mesh size and the choice of the Weibull threshold parameter. All three sensitivity studies: the volume grouping criteria, the mesh size, and the threshold parameter choice are found to affect the component qualification decision for components of structural reliability class 1 (SRC-1). The sensitivity analysis results are presented in the body of the report for NBG-18, which is the same grade of graphite as Hindley used in his thesis. Results from NBG-17, IG-110, 2114, and PCEA are presented in the Appendix. For NBG-18, it was found that increasing the threshold increases the POF, finer meshes result in higher POFs, and that smaller link volume requirements lead to higher POFs (which is inconsistent with Hindley’s findings). This report proposes a new validation study similar to Hindley’s []. The purpose of the new validation study is to tune the threshold, mesh size and grouping criteria based on results from multiple grades of graphite, including finer grain graphites T220 (1-3 microns) and NG-CT-50 (5 microns). The test specimens will be broken at 3 labs, such that we can measure between lab measurement variability, with at least 5 test specimens per lab such that the within lab uncertainty can also be measured. Hindley’s validation method tried matching the average experimental load with the median. The future study will attempt to match failures at lower percentiles, which would be closer to the SRC POF limit. We are currently looking into what geometries make sense and the best method to measure multi-axial stress states. These design decisions are still being set.

36 MATERIALS SCIENCE↗

Analysis of New High-Q0 SRF Cavity Tests by Nitrogen Gas Doping at Jefferson Lab

In order to refine systematic understanding and establish confident process control, Jefferson Lab has joined with partners to investigate and thoroughly characterize the dramatically higher Q0 of 1.3 GHz niobium cavities first reported by FNAL in 2013[1]. With partial support from the LCLS-II project, JLab has undertaken a parametric study of nitrogen doping in vacuum furnace at 800 °C followed by variable depth surface removal in the 5 - 20 μm range. Q0 above 3×1010 are typical at 2.0 K and 16 MV/m accelerating field. We report observations from the single cell study and current interpretations. In addition to the parametric single cell study, we also report on the ongoing serial testing of six nitrogen-doped 9-cell cavities as baseline prototypes for LCLS-II.

Palczewski, Ari D.↗

ISS External Microorganisms: Collecting Planetary Protection Samples During Extravehicular Activity

Introduction: We have designed1, built, and tested a sampling kit (Fig. 1) to aseptically collect microbiological samples from exterior surfaces on the ISS (International Space Station). The kit was flown to ISS as part of the NG-19 commercial cargo mission in August of 2023. Astronauts will use the kit to collect samples from six exterior surfaces on ISS. These samples will be frozen at -80°C after collection and returned to the ground for next generation DNA sequencing. The results of this experiment will help inform planetary protection requirements for crewed missions. We hypothesize that there are detectable microbial communities outside ISS and that these communities originate from inside ISS. Current life support systems do not include any components for reducing microbial leakage. Gases are vented from inside ISS without filtration and there are currently no protocols in place to minimize bioburden on space suit exteriors prior to use. It is important to quantify the bioburden on current vehicles so that achievable limits can be set for crewed missions to astrobiologically relevant locations like Mars. Figure 1: The sampling kit contains eight swab canisters in total (six on the top and two on the bottom). A resuable end effector (1) is used to remove and reinstall the swabs. The kit also contains a handrail (2), tether loop (3), and, bayonet probes(4) to allow easy manipulation during EVA. Methods: We have designed a kit to carry 8 commercially available foam swabs into and out of vacuum without compromising the swabs’ sterility. The specially designed swab canisters contain a 0.2 µm Teflon filter that allows the canister to accommodate pressure changes without introducing unwanted contaminants. The kit meets existing EVA (Extravehicular Activity) safety requirements and has been used by human test subjects in the neutral buoyance lab and at vacuum in test chambers at the Johnson Space Center. In the early part of 2024, astronauts will use this sampling kit to swab six surfaces on the exterior of ISS. We will collect samples from: the airlock vestibule, the interior surface of the airlock thermal cover, an exterior handrail, a vent connected to the CO2 removal system, and a vent connected to the payload vacuum system inside ISS. Approximately 300 cm2 will be swabbed at each location. A seventh swab will be exposed to the vacuum of space without touching any surfaces as a blank. The eighth swab will remain sealed as a process control. After the EVA the swab kit will be frozen at -80°C and returned to earth at the earliest possible opportunity. The samples will remain frozen until they are thawed for next generation DNA sequencing on earth. We will use amplicon sequencing to identify any bacteria, archaea or fungi present in the samples. If there is enough DNA present, we will use shotgun metagenomic sequencing to further characterize the microbial ecology outside ISS. Preliminary Results: Results from ground-based testing demonstrate that the swab kit is capable of cycling in and out of vacuum without contaminating the swabs. Test subjects, wearing flight-like EVA gloves could remove swabs from the canister and sample discrete locations without inadvertently touching any other surfaces. Several types of bacteria and fungi were collected during these ground tests and survived up to 6 hours at vacuum. This includes non-spore forming bacterial like Staphyloccus capitis that are not traditionally considered extremophiles. Shotgun metagenomic sequencing of the ground-test samples revealed bacteria associated with human skin and airways on the exterior of space suits used during these tests 2 In addition to these results we will present preliminary results from our space-flight samples. We will also present lessons learned from attempting to collect microbiological samples during an EVA and describe how our results will affect planetary protection requirements for future crewed missions.

Aaron B. Regberg↗

ISS External Microorganisms: Collecting Planetary Protection Samples During Extravehicular Activity

Introduction: We have designed1, built, and tested a sampling kit (Fig. 1) to aseptically collect microbiological samples from exterior surfaces on the ISS (International Space Station). The kit was flown to ISS as part of the NG-19 commercial cargo mission in August of 2023. Astronauts will use the kit to collect samples from six exterior surfaces on ISS. These samples will be frozen at -80°C after collection and returned to the ground for next generation DNA sequencing. The results of this experiment will help inform planetary protection requirements for crewed missions. We hypothesize that there are detectable microbial communities outside ISS and that these communities originate from inside ISS. Current life support systems do not include any components for reducing microbial leakage. Gases are vented from inside ISS without filtration and there are currently no protocols in place to minimize bioburden on space suit exteriors prior to use. It is important to quantify the bioburden on current vehicles so that achievable limits can be set for crewed missions to astrobiologically relevant locations like Mars. Figure 1: The sampling kit contains eight swab canisters in total (six on the top and two on the bottom). A resuable end effector (1) is used to remove and reinstall the swabs. The kit also contains a handrail (2), tether loop (3), and, bayonet probes(4) to allow easy manipulation during EVA. Methods: We have designed a kit to carry 8 commercially available foam swabs into and out of vacuum without compromising the swabs’ sterility. The specially designed swab canisters contain a 0.2 µm Teflon filter that allows the canister to accommodate pressure changes without introducing unwanted contaminants. The kit meets existing EVA (Extravehicular Activity) safety requirements and has been used by human test subjects in the neutral buoyance lab and at vacuum in test chambers at the Johnson Space Center. In the early part of 2024, astronauts will use this sampling kit to swab six surfaces on the exterior of ISS. We will collect samples from: the airlock vestibule, the interior surface of the airlock thermal cover, an exterior handrail, a vent connected to the CO2 removal system, and a vent connected to the payload vacuum system inside ISS. Approximately 300 cm2 will be swabbed at each location. A seventh swab will be exposed to the vacuum of space without touching any surfaces as a blank. The eighth swab will remain sealed as a process control. After the EVA the swab kit will be frozen at -80°C and returned to earth at the earliest possible opportunity. The samples will remain frozen until they are thawed for next generation DNA sequencing on earth. We will use amplicon sequencing to identify any bacteria, archaea or fungi present in the samples. If there is enough DNA present, we will use shotgun metagenomic sequencing to further characterize the microbial ecology outside ISS. Preliminary Results: Results from ground-based testing demonstrate that the swab kit is capable of cycling in and out of vacuum without contaminating the swabs. Test subjects, wearing flight-like EVA gloves could remove swabs from the canister and sample discrete locations without inadvertently touching any other surfaces. Several types of bacteria and fungi were collected during these ground tests and survived up to 6 hours at vacuum. This includes non-spore forming bacterial like Staphyloccus capitis that are not traditionally considered extremophiles. Shotgun metagenomic sequencing of the ground-test samples revealed bacteria associated with human skin and airways on the exterior of space suits used during these tests 2 In addition to these results we will present preliminary results from our space-flight samples. We will also present lessons learned from attempting to collect microbiological samples during an EVA and describe how our results will affect planetary protection requirements for future crewed missions.

Aaron B. Regberg↗

Transportation Modeling and Global Health

A patient in the United States has been diagnosed with Ebola. Fear and panic kicks in across the country, and hospitals are inundated with hundreds of people, some infected with the highly contagious disease and others not. Blood tests are needed for positive diagnoses, but the diagnostic labs are overwhelmed with blood samples to test, and staff are overworked and stressed. Infected people need to be quarantined and treated, but it's hard to find rooms to quarantine so many patients. Sick people who need triage and regular care for other emergencies are afraid to go to hospitals for fear of Ebola, which has a 50% fatality rate. And since hospitals are so overwhelmed, sick people often stay home, infecting heathy people around them; the U.S. is now in the grips a full-blown Ebola outbreak. Sandia's high-performance computers simulated such a nightmare scenario recently, and with good reason. An Ebola outbreak in the United States could be devastating if hospitals are not prepared. When an Ebola outbreak in West Africa became a global concern in 2014, health advisers were alarmed at the length of time it took to properly diagnose infected people. In rural areas in Liberia, for example, blood samples from ailing people would be sent to a laboratory for testing, but the closest lab was hundreds of miles away through difficult and sometimes impassable roads. In more urban areas, blood samples would be sent to nearby labs, but those labs were often already overburdened by the sheer volume of samples to test. Staff at some treatment centers were unaware that a lab a little farther away might have the capacity to take in more samples. Meanwhile, undiagnosed infected people were unknowingly spreading the disease to many others around them, worsening the outbreak. The U.S. Defense Threat Reduction Agency (DTRA) and Centers for Disease Control and Prevention (CDC) posed a serious question: how do we improve blood-sample transportation routes in Liberia to ensure that samples taken from ill people are tested as quickly as possible, ensuring a proper diagnosis and faster treatment? Sandia scientists, already experts in transportation modeling for nuclear materials, quickly swarmed on this problem. The Sandia Ebola response team immediately set out to collect data from the region using available maps and local information, and transformed the raw data to GIS maps. Then, applying Sandia transportation routing algorithms, the team identified the optimal routes to get blood samples to the best laboratory for testing, even if that lab was not geographically the closest. The models also showed the best possible locations for mobile diagnostic laboratories that would better support the very rural regions that were most affected by the Ebola outbreak.

59 BASIC BIOLOGICAL SCIENCES↗

Laser doppler velocimeter system for subsonic jet mixer nozzle testing at the NASA Lewis Aeroacoustic Propulsion Lab

A laser Doppler velocimeter (LDV) system developed for the Aeroacoustic Propulsion Laboratory (APL) at the NASA Lewis Research Center is described. This system was developed to acquire detailed flow field data which could be used to quantify the effectiveness of internal exhaust gas mixers (IEGM's) and to verify and calibrate computational codes. The LDV was used as an orthogonal, three component system to measure the flow field downstream of the exit of a series of IEGM's and a reference axisymmetric splitter configuration. The LDV system was also used as a one component system to measure the internal axial flow within the nozzle tailpipe downstream of the mixers. These IEGM's were designed for low-bypass ratio turbofan engines. The data were obtained at a simulated low flight speed, high-power operating condition. The optical, seeding, and data acquisition systems of the LDV are described in detail. Sample flow field measurements are provided to illustrate the capabilities of the system at the time of this test, which represented the first use of LDV at the APL. A discussion of planned improvements to the LDV is also included.

Podboy, Gary G.↗

Exhaust System Experiments at NASA's AeroAcoustic Propulsion Lab

This presentation gives an overview of the planned testing in the AeroAcoustic Propulsion Lab (AAPL) in the coming 15 months. It was stressed in the presentation that these are plans that are subject to change due to changes in funding and/or programmatic direction. The first chart shows a simplified schedule of test entries with funding sponsor and dates for each. In subsequent charts are pages devoted to the Objectives and Issues with each test entry, along with a graphic intended to represent the test activity. The chart for each test entry also indicates sponsorship of the activity, and a contact person.!

Bridges, James↗

Cryogenic System for the Cryomodule Test Facility at Fermilab

This paper provides an overview of the current progress and near-future plans for the cryogenic system at the new Cryomodule Test Facility (CMTF) at Fermilab, which includes the helium compressors, refrigerators, warm vacuum compressors, gas and liquid storage, and a distribution system. CMTF will house the Project X Injector Experiment (PXIE), which is the front end of the proposed Project X. PXIE includes one 162.5 MHz half wave resonator (HWR) cryomodule and one 325 MHz single spoke resonator (SSR) cryomodule. Both cryomodules contain superconducting radio-frequency (SRF) cavities and superconducting magnets operated at 2.0 K. CMTF will also support the Advanced Superconducting Test Accelerator (ASTA), which is located in the adjacent New Muon Lab (NML) building. A cryomodule test stand (CMTS1) located at CMTF will be used to test 1.3 GHz cryomodules before they are installed in the ASTA cryomodule string. A liquid helium pump and transfer line will be used to provide supplemental liquid helium to ASTA.

White, Michael↗

Fluidized-bed and fixed-bed reactor testing of methane chemical looping combustion with MgO-promoted hematite

In this article MgO-promoted Fe 2 O 3 hematite oxygen carriers were synthesized from various Mg sources and evaluated for methane chemical looping combustion. Particles suitable for fluidized bed flow reactor studies were prepared in the lab. Cyclic CLC tests conducted in the fluidized bed with MgO promoted hematite showed better performance than that with hematite. Attrition resistance of laboratory prepared MgO promoted hematite was excellent. Reactivity and stability of the oxygen carrier materials were also tested in the thermogravimetric analyzer and bench-scale reactors. Scanning electron microscopy and energy-dispersive X-ray spectroscopy, and X-ray diffraction were used to study the morphology and elemental compositions present in the hematite and promoted hematite oxygen carriers prior to and following the multi-cycle chemical looping reaction. The incorporation of 5 wt% MgO led to an increased reaction rate and an increase in oxygen utilized as compared to the pure hematite oxygen carrier. Possible reasons for the promotion effect by MgO were evaluated. These studies reveal that the best performing oxygen carrier was the 5 wt% MgO/Fe 2 O 3 which exhibited no observed degradation in the kinetics and conversion performance in the methane step over 15 reduction and oxidation cycles. The Mg promoted oxygen carrier also showed reduced coke formation as compared to the pure hematite carrier.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Review of ingot niobium as a material for superconducting radiofrequency accelerating cavities

As a result of collaboration between Jefferson Lab and niobium manufacturer Companhia Brasileira de Metalurgia e Mineração (CBMM), ingot niobium was explored as a possible material for superconducting radiofrequency (SRF) cavity fabrication. The first single cell cavity from large-grain high purity niobium was fabricated and successfully tested at Jefferson Lab in 2004. This work triggered research activities in other SRF laboratories around the world. The large-grain (LG) niobium became not only an interesting alternative material for cavity builders, but also material scientists and surface scientists were eager to participate in the development of this technology. Many single cell cavities made from material of different suppliers have been tested successfully and several multi-cell cavities have shown performances comparable to the best cavities made from standard fine-grain niobium. Several 9-cell cavities fabricated by Research Instruments and tested at DESY exceeded the best performing fine grain cavities with a record accelerating gradient of E acc =45.6 MV/m. The quality factor of those cavities was also higher than that of fine-grain (FG) cavities processed with the same methods. Such performance levels push the state-of-the art of SRF technology and are of great interest for future accelerators. This contribution reviews the development of ingot niobium technology and highlights some of the differences compared to standard FG material and opportunities for further developments.

36 MATERIALS SCIENCE↗

Experiments investigating advanced materials under thermomechanical loading

Many high temperature aircraft and rocket engine components experience large mechanical loads as well as severe thermal gradients and transients. These nonisothermal conditions are often large enough to cause inelastic deformations, which are the ultimate cause for failure in those parts. A way to alleviate this problem is through improved engine designs based on better predictions of thermomechanical material behavior. To address this concern, an experimental effort was recently initiated within the Hot Section Technology (HOST) program at Lewis. As part of this effort, two new test systems were added to the Fatigue and Structures Lab., which allowed thermomechanical tests to be conducted under closely controlled conditions. These systems are now being used for thermomechanical testing for the Space Station Receiver program, and will be used to support development of metal matrix composites.

Bartolotta, Paul A.↗

Lowering of the firing voltage and reducing of the discharge delay time in alternating current plasma display panels by a discontinuous spin-coated LaB{sub 6} film on the MgO protective layer

A spin coated LaB{sub 6} discontinuous film is covered on MgO protective layer to improve the discharge performance of alternating current plasma display panels. Under the premise of high transmittance of more than 90%, a very small amount of polycrystal LaB{sub 6} powders added in an organic solvent are chosen as the coating solution. The discharge characteristics results show that with 250 torr 5% Xe-Ne pressure, the firing voltage and discharge delay time of the test panel with LaB{sub 6}/MgO double protective layer are decreased by 13.4% and 36.5%, respectively, compared with that of conventional MgO protective layer, likely owing to the low work function of LaB{sub 6.} Furthermore, the aging time of the proposed structure is comparable to that of pure MgO protective layer. Therefore, it will not increase the production costs and is highly suitable to be applied for alternating current plasma display panels with low electrical power consumption.

36 MATERIALS SCIENCE↗