Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “instrument designs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

A study for hypergolic vapor sensor development

The use of an electrochemical technique for MMH and N02 measurement was investigated. Specific MMH and N02 electrochemical sensors were developed. Experimental techniques for preparation, handling, and analysis of hydrazine's vapor mixtures at ppb and ppm levels were developed. Two approaches to N02 instrument design were evaluated including specific adsorption and specific electrochemical reduction. Two approaches to hydrazines monitoring were evaluated including catalytic conversion to N0 with subsequent N0 detection and direct specific electrochemical oxidation. Two engineering prototype MMH/N02 monitors were designed and constructed.

Stetter, J. R.↗

Transient response measurements on a satellite system

A set of instruments designed to detect the occurance of electrical breakdown was flown on a synchronous-orbit satellite. The LeRC sensors were installed on cables inside the vehicle. Accordingly, they respond to signals coupled into the satellite wiring system. The SRI sensors were located on the exterior of the vehicle and detected the RF noise pulses associated with surface breakdowns. The results of the earlier SRI program are being used to design and develop a set of intrumentation suitable for inclusion as a general piggy-back package for the detection of the onset of satellite charging and breakdowns on synchronous orbit satellites.

Nanevicz, J. E.↗

Soviet-French working group interpretation of the scientific information during the search for celestial sources of gamma pulses, abstract of reports, 24-30 March 1977

The progress made and techniques used by the Soviet-French group in the study of gamma and X ray pulses are described in abstracts of 16 reports. Experiments included calibration and operation of various recording instruments designed for measurements involving these pulses, specifically the location of sources of such pulses in outer space. Space vehicles are utilized in conjunction with ground equipment to accomplish these tests.

Estulin, I. V.↗

Calibration analysis for a multi-channel infrared scanning radiometer

A procedure for calibrating an infrared scanning spectroradiometer by a computerized parametric error analysis technique was developed. The uncertainties in the radiometric measurements of scene radiance and (for the case of a blackbody scene) temperature due to possible uncertainties in the calibration target temperature, calibration target emissivity, and instrument temperature were calculated for a range of uncertainty levels in the parameters, as well as for a gamut of scent temperatures corresponding to a given spectral channel. This technique is applicable to the radiometric calibration of any infrared radiometer. It was applied specifically to the Cloud-Top Scanning (C.T.S) Radiometer, a three-channel instrument designed for aircraftborne cloud radiance measurements in the 6.75 and 11.5 micron thermal emission spectral regions.

Walden, H.↗

Imaging Proportional X-ray Counter for HEAO

The HEAO-B Imaging Proportional Counter (IPC) is an X-ray imaging instrument designed for use in the High Energy Astronomy Observatory - Mission B (HEAO-B) X-ray Telescope. It measures the spatial location of individual X-ray photons by the risetime method and energy of photons by pulse height analysis. The IPC can locate photons in the energy range 0.2 to 4 keV to within 1 mm and provides 5 bits of energy level information. Each measured X-ray event is also time tagged with 7 bits of temporal data. The IPC also includes an in-flight-calibration source and uses a gas control system that maintains the counter gas density constant to an accuracy of 0.25 percent.

Humphrey, A.↗

Venus Orbital Imaging Radar mission analysis

Mission objectives for the Venus Orbital Imaging Radar (VOIR) project are outlined with attention to its scientific instrumentation. Design parameters of the SAR (Synthetic Aperture Radar) are described, including a high resolution capability of 200 m from a circular orbit of 375 km, which will be able to map the entire surface of the planet. Nineteen atmospheric experiments are foreseen, among them: CO2 stability assays, measurements of vertical mass transfer rates, observations of cloud circulation and composition, and an evaluation of solar wind effects on atmospheric dynamics. Navigation and orbital injection plans are reviewed, noting that the 1983 launch window (using STS) is optimum.

Nock, K. T.↗

The ISEE-C vector helium magnetometer

The ISEE-C magnetometer will make continuous observations of the interplanetary magnetic field near 1 AU. This paper describes the scientific objectives of the magnetometer experiment and gives attention to instrument design (sensor, electronics, and operating principles). A functional block diagram of the system is presented and attention is given to minor modifications required by the ISEE mission (the magnetometer is essentially one that served as the spare unit for the Pioneer 10 and 11 missions to Jupiter).

Frandsen, A. M. A.↗

The electron spectrometer experiment on ISEE-1

A six-axis electron spectrometer for the ISEE-1 spacecraft is described and some typical early results presented. This instrument, designed for three-dimensional plasma distribution function studies in the solar wind, magnetosheath, outer magnetosphere, and near tail regions, has three energy ranges: 7.5-512 eV, 11-2062 eV, and 109-7285 cV, respectively. Two channel electron multipliers are used at the output of each of six cylindrical electrostatic analyzers. The total mass of two sensors and a data processing unit is 4.9 kg and the power comsumption is 3.5 W. Two hundred information bits/s telemetry rate is required.

Ogilvie, K. W.↗

Rocket observations of solar radiation during the eclipse of 26 February 1979

Three Nike Tomahawk rockets were launched in Red Lake, Ontario, one previous to, and two during, the total eclipse of the Sun, for the purpose of studying the atmosphere and its interaction with solar radiation. The method and preliminary results of three experiments that were used to measure solar radiation in the X-ray, Lyman-alpha, and visible parts of the spectrum are described. The instrumentation designed for this investigation is discussed as well as post-flight data processing techniques. The retrieved data were processed to some extent to verify that a valid representation of the solar radiation was obtained. The Lyman-alpha experiment yielded very good results, and preliminary data are included. The visible radiation experiment served as support for the other experiments and also functioned well. Due to a high level of energetic particles during the eclipse, the X-ray data were contaminated and are not presented. However, satellite observations indicate no appreciable level of X-rays from the Sun during the time of the eclipse.

Bliss, H. M.↗

The Pioneer Venus Orbiter plasma wave investigation

The Pioneer Venus plasma wave instrument has a self-contained balanced electric dipole (effective length = 0.75 m) and a 4-channel spectrum analyzer (30% bandwidth filters with center frequencies at 100 Hz, 730 Hz, and 30 kHz). The channels are continuously active and the highest Orbiter telemetry rate (2048 bits/sec) yields 4 spectral scans/sec. The total mass of 0.55 kg includes the electronics, the antenna, and the antenna deployment mechanism. This report contains a brief description of the instrument design and a discussion of the in-flight performance.

Scarf, F. L.↗

Submillimeter wave survey of the galactic plane

The survey measured, over virtually the entire galactic plane, the distribution and basic physical conditions of the coolest dust component of the interstellar medium. The instrument designed for observations of extended, low surface brightness continuum emission consisted of a balloon borne, gyro stablized, 1.2 m Cassegrain telescope and a liquid cooled photometer. The design, integration, tests, and flight operation of the survey are presented.

Cheung, L. H.↗

Auroral X-ray detection from rocket overflights

Remote sensing of auroral X-rays from the topside can provide both local and global information concerning X-ray and energetic particle deposition within the middle atmosphere. Usually, contamination of X-ray detectors by corpuscular radiation can severely affect the scope and accuracy of the measurement. Preliminary results obtained with a rocket-borne instrument designed to operate cleanly in a precipitating particle environment are reported. Two dimensional images of the atmospheric bremsstrahlung X-ray sources were also constructed from the detector scan produced by payload translation and coning.

Goldberg, A.↗

The retarding ion mass spectrometer on dynamics Explorer-A

An instrument designed to measure the details of the thermal plasma distribution combines the ion temperature-determining capability of the retarding potential analyzer with the compositional capabilities of the mass spectrometer and adds multiple sensor heads to sample all directions relative to the spacecraft ram directions. The retarding ion mass spectrometer, its operational modes and calibration are described as well as the data reduction plan, and the anticipated results.

Chappell, C. R.↗

Transfer-matrices for series-type microwave antenna circuits

Transfer matrices are developed which permit analysis and computer evaluation of certain series type microwave antenna circuits associated with an L-Band microwave radiometer (LBMR) under investigation at Goddard Space Flight Center. This radiometer is one of several diverse instrument designs to be used for the determination of soil moisture, sea state, salinity, and temperature data. Four port matrix notation is used throughout for the evaluation of LBMR circuits with mismatched couplers and lossy transmission lines. Matrix parameters in examples are predicted on an impedance analysis and an assumption of an array aperture distribution. The notation presented is easily adapted to longer and more varied chains of matrices, and to matrices of larger dimension.

Schmidt, R. F.↗

Development of a fast ion mass spectrometer for space research

An ion mass spectrometer having a cylindrical E bar x B bar analyzer and either a cylindrical or spherical electrostatic analyzer is described. The instrument has two nested channels and a postacceleration between the electrostatic and E bar x B bar analyzers for wide ranges of energy and mass responses. It is noted that the dual-channel construction not only doubles the data acquisition rate but also permits a reversal of the electrostatic field orientation in the inner channel for lighter ions. The outer channel is then optimized for ions of medium to high mass numbers, resulting in increased mass resolution for such heavy ions. When combined with a cylindrical E bar x B bar analyzer, a 90-deg-deflection angle spherical electrostatic analyzer provides an extremely wide viewing angle. The angular distribution of ions can be derived from such geometry if a position-sensitive resistive anode or a detector array is used at the exit aperture. Details on the principles of operation, the instrument design, and calibration are presented.

Hahn, S. F.↗

Effect of atmospheric scattering and surface reflection on upwelling solar radiation

A study is presented of the solar radiation transfer in the complete earth-atmosphere system, and numerical results are compared with satellite data obtained during the Earth Radiation Budget Experiment on Nimbus 6, in August, 1975. Emphasis is placed on the upwelling radiance distribution at the top of the atmosphere, assumed to be at 50 km. The numerical technique is based on the finite difference method, which includes azimuth and spectral variations for the entire solar wavelength range. Detailed solar properties, atmospheric physical properties, and optical properties are used. However, since the property descriptions are based on a trade-off between accuracy and computational realities, aerosol and cloud optical properties are treated with simple approximations. The radiative transfer model is in good agreement with the satellite radiance observations. The method provides a valuable tool in analyzing satellite- and ground-based radiation budget measurements and in designing instrumentation.

Suttles, J. T.↗

Development of a polysilicon process based on chemical vapor deposition (phase 1)

A dichlorosilane-based reductive chemical vapor deposition (CVD) process demonstrated is capable of producing, at low cost, high quality polycrystalline silicon. Testing of decomposition reactor heat shields to insure that the shield provides adequate personnel protection assuming a worst case explosion was completed. Minor modifications to a production reactor heat shield provided adequate heat shield integrity. Construction of the redesigned PDU (Process Development Unit) to accommodate all safety related information proceeded on schedule. Structural steel work was completed as is the piping and instrumentation design work. Major pieces of process equipment were received and positioned in the support structure and all transfer piping and conduits to the PDU were installed. Construction was completed on a feed system for supplying DCS to an intermediate sized reactor. The feed system was successfully interfaced with a reactor equipped with a modified heat shield. Reactor checkout was completed.

Mccormick, J.↗

A Wolter type I LAMAR

Observational objectives for the LAMAR and their influence on the instrument design are discussed. It is concluded that the most important design parameter is the angular resolution of the LAMAR modules since it so strongly influences sensitivity, optical identifications, source confusion, spectral resolution for objective gratings and the ability to resolve small extended sources. A high resolution Wolter Type I LAMAR module is described, its hardware status discussed, and the performance of a LAMAR observatory presented. A promising technique for enhancing the reflectivity of Wolter Type I X-ray optics in a selected bandpass at high energy has been investigated and the performance of the LAMAR module, utilizing this method, has been calculated.

Catura, R. C.↗