Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Impact of Insulation Strategies of Cross-Laminated Timber Assemblies on Energy Use, Peak Demand, and Carbon Emissions

Cross-Laminated Timber (CLT) panels have many structural benefits but do not have much thermal resistance. We have developed a solution to insulate CLT structures that uses high-performance insulation panels that provide R-values up to R40/inch. The CLT panels are made of layers of wood laminates (three, five, seven or more). The solution replaces some of the wood laminates in the CLT production with the insulation panels in a staggered fashion so that the wood laminates maintain contact throughout the panel, ensuring the CLT panel’s structural integrity. The insulated CLT panels have factory-installed water-resistive barriers reducing the installation time by eliminating installing insulation and water-resistive barriers on site. Per simulations, the CLT/insulation panel achieved code-required insulation levels with commonly available insulation materials. The significance of the thermal mass of CLT/insulation hybrid building envelopes was quantified by comparing the whole building energy performance and peak demand of traditional low mass and CLT wall assemblies resulting in up to 7% reduction in peak demand for cooling in Knoxville, TN, in a multifamily building. Buildings contribute over 40 percent of carbon emissions. The proposed CLT/insulation hybrid building envelope addresses both operational and embodied carbon by having high thermal resistances due to the embedded insulation sections and eliminating the use of high embodied carbon materials such as steel and concrete. The carbon benefit is estimated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Valuation of Wind Energy Turbines Using Volatility of Wind and Price

The limitedness of the nonrenewable local energy resources in Israel, even in the background of the later gas fields’ findings, continues to force the state to devote various efforts towards ‘green’ energy development. These efforts include installations, both for the solar and for wind energy, thus improving the diversity of energy sources. While the standard discounted cash flow (DCF) method using the net present value (NPV) criterion is extensively adopted to evaluate investments, the standard DCF method is inappropriate for the rapidly changing investment climate and for the managerial flexibility in investment decisions. In recent years, the real options analysis (ROA) technique has been widely applied in many studies for the valuation of renewable energy investment projects. Taking into account the above background, we apply, in this study, the real options analysis approach for the valuation of wind energy turbines and apply it to the analysis of wind energy economic potential in Israel, which is the context of our work. We hypothesize that due to nature of wind energy production uncertainties, the ROA method is better than the alternative. The novelty of this paper includes the following: real world wind statistics of the Merom Golan site in Israel (velocity 3.73 m/s, with a standard deviation of 2.03 m/s), a realistic power generation estimation (power generation of 1205.84 kW with a standard deviation of about 0.5% in annual value which is worth about 1.3 M$ per annum), and an economic model to evaluate the profitability of such a project. We thus discuss the existing challenges of diversifying renewable energy sources in Israel by adding wind installations. Our motivation is to introduce a method which will allow investors and officials to take into account uncertainties when deciding in investing in such wind installations. The outcomes of the paper, which are obtained using the method of Weibull statistics and the Black–Scholes ROA technique, include the result that market price volatility adds to the uncertainties much more than any wind fluctuations, provided that the analysis is integrated over a long enough time.

17 WIND ENERGY↗

Estimating the Performance Loss Rate of Photovoltaic Systems Using Time Series Change Point Analysis

The accurate quantification of the performance loss rate of photovoltaic systems is critical for project economics. Following the current research activities in the photovoltaic performance and reliability field, this work presents a comparative assessment between common change point methods for performance loss rate estimation of fielded photovoltaic installations. An extensive testing campaign was thus performed to evaluate time series analysis approaches for performance loss rate evaluation of photovoltaic systems. Historical electrical data from eleven photovoltaic systems installed in Nicosia, Cyprus, and the locations’ meteorological measurements over a period of 8 years were used for this investigation. The application of change point detection algorithms on the constructed monthly photovoltaic performance ratio series revealed that the obtained trend might not always be linear. Specifically, thin film photovoltaic systems showed nonlinear behavior, while nonlinearities were also detected for some crystalline silicon photovoltaic systems. When applying several change point techniques, different numbers and locations of changes were detected, resulting in different performance loss rate values (varying by up to 0.85%/year even for the same number of change points). The results highlighted the importance of the application of nonlinear techniques and the need to extract a robust nonlinear model for detecting significant changes in time series data and estimating accurately the performance loss rate of photovoltaic installations.

photovoltaics↗

Techno-Economic Assessment of CHP Systems in Wastewater Treatment Plants

Wastewater treatment plant (WWTP) utilization of combined heat and power (CHP) systems allows for the efficient use of on-site biogas production, as well as increased annual savings in utility costs. In this paper, a review of biogas energy recovery options, CHP prime mover technologies, and the costs associated with biogas cleaning give a broad summary of the current state of CHP technology in WWTPs. Even though there are six different prime mover technologies, the main ones currently being implemented in WWTPs are micro turbines, fuel cells and reciprocating engines. Different prime movers offer varying efficiencies, installation costs, and biogas impurity (H2S, siloxanes, HCl) tolerances. To evaluate the long-term savings capabilities, a techno-economic assessment of a CHP installation at a case study WWTP shows the payback, annual savings, and initial costs associated with the installation of a CHP system. In this case, a study a payback of 5.7 years and a net present value of USD 709,000 can be achieved when the WWTP generates over 2,000,000 m3 of biogas per year and utilizes over 36,000 GJ of natural gas per year.

54 ENVIRONMENTAL SCIENCES↗

Agrivoltaic Decision Tools for Perennial and Field Crop Farmers

This article describes a series of spreadsheet-based tools to help farmers estimate costs, revenues, and yields from agricultural production under different configurations of agrivoltaic installations for field and perennial crops. Crop-specific log books allow farmers to project changes in activity-level costs from the field due to agrivoltaic installations. The whole-farm tool helps farmers aggregate activity-level net returns up to the farm level to calculate projections of trade-offs between crop production with or without agrivoltaic installations. We present tools for lettuce and cranberries, but the tools are comprehensive and inclusive and so can be modified for other perennial and field crops.

14 SOLAR ENERGY↗

MIRC-X: A Highly Sensitive Six-telescope Interferometric Imager at the CHARA Array

Michigan InfraRed Combiner-eXeter (MIRC-X) is a new highly sensitive six-telescope interferometric imager installed at the CHARA Array that provides an angular resolution equivalent of up to a 330 m diameter baseline telescope in J- and H-band wavelengths ((λ/(2B))∼0.6 mas). We upgraded the original Michigan InfraRed Combiner (MIRC) instrument to improve sensitivity and wavelength coverage in two phases. First, a revolutionary sub-electron noise and fast-frame-rate C-RED ONE camera based on an SAPHIRA detector was installed. Second, a new-generation beam combiner was designed and commissioned to (i) maximize sensitivity, (ii) extend the wavelength coverage to J band, and (iii) enable polarization observations. A low-latency and fast-frame-rate control software enables high-efficiency observations and fringe tracking for the forthcoming instruments of the CHARA Array. Since mid-2017, MIRC-X has been offered to the community and has demonstrated best-case H-band sensitivity down to 8.2 correlated magnitude. MIRC-X uses single-mode fibers to coherently combine the light from six telescopes simultaneously with an image-plane combination scheme and delivers a visibility precision better than 1%, and closure phase precision better than 1°. MIRC-X aims at (i) imaging protoplanetary disks, (ii) detecting exoplanets with precise astrometry, and (iii) imaging stellar surfaces and starspots at an unprecedented angular resolution in the near-infrared. In this paper, we present the instrument design, installation, operation, and on-sky results, and demonstrate the imaging capability of MIRC-X on the binary system ι Peg. The purpose of this paper is to provide a solid reference for studies based on MIRC-X data and to inspire future instruments in optical interferometry.

79 ASTRONOMY AND ASTROPHYSICS↗

LHCspin: a Polarized Gas Target for LHC

The goal of the LHCspin project is to develop innovative solutions for measuring the 3D structure of nucleons in high-energy polarized fixed-target collisions at LHC, exploring new processes and exploiting new probes in a unique, previously unexplored, kinematic regime. A precise multi-dimensional description of the hadron structure has, in fact, the potential to deepen our understanding of the strong interactions and to provide a much more precise framework for measuring both Standard Model and Beyond Standard Model observables. This ambitious task poses its basis on the recent experience with the successful installation and operation of the SMOG2 unpolarized gas target in front of the LHCb spectrometer. Besides allowing for interesting physics studies ranging from astrophysics to heavy-ion physics, SMOG2 provides an ideal benchmark for studying beam-target dynamics at the LHC and demonstrates the feasibility of simultaneous operation with beam-beam collisions. With the installation of the proposed polarized target system, LHCb will become the first experiment to simultaneously collect data from unpolarized beam-beam collisions at $\sqrt{s}$=14 TeV and polarized and unpolarized beam-target collisions at $\sqrt{s_{NN}}\sim$100 GeV. LHCspin has the potential to open new frontiers in physics by exploiting the capabilities of the world's most powerful collider and one of the most advanced spectrometers. This document also highlights the need to perform an R&D campaign and the commissioning of the apparatus at the LHC Interaction Region 4 during the Run 4, before its final installation in LHCb. This opportunity could also allow to undertake preliminary physics measurements with unprecedented conditions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DGPS measurements of solifluction and hillslopes creep at the Teller 47 field site from 2017-2022, Seward Peninsula, AK

DGPS measurements of benchmarks locations were collected during the 2017, 2018, 2019, 2021 and 2022 summers at the NGEE Arctic Teller-47 solifluction site on the Seward Peninsula, Alaska. Benchmarks were installed in 2017 on several solifluction lobes and hillslope locations and re surveyed in 2018 and 2019 with a Trimble R10 DGPS instrument. In 2018, coincident with a UAS-based laser altimetry collection campaign, more ground control targets were installed and subsequently remeasured in 2019. Additional ground control targets were installed in 2021. Points were corrected using NOAA’s Online Positioning User Software (OPUS) and Trimble Business Center (TBC) software. An update to this dataset was made in July 2024, adding new data from 2021 and 2022. The dataset now contains ten total *.csv files: five are data files plus one file-level metadata and five data dictionaries, two *.jpg, four shape file folders, two *.kml, one archive folder of raw data, and one *.pdf. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

Impacts of Electric Space Heating in Multifamily Apartments in Juneau, Alaska [Slides]

The study objective was to understand the change in electrical consumption and cost after the addition of a ductless mini-split air-source heat pump (ASHP) across rental apartments heated by electrical resistance heating systems in multifamily buildings in Juneau, Alaska. Alaska Electric Light and Power Company (AELP), the utility in Juneau, Alaska, funded installation of 19 heat pumps across four buildings. Using electrical meter interval data, including the total apartment consumption and submeter data for each heating appliance (electric resistance baseboard and heat pump), the National Laboratory of the Rockies (NLR) calculated energy use metrics before and after heat pump installation and visualized results. Through this research, NLR compares electrical use (total and specific to heating appliances), adjusted for weather and apartment size, and electrical demand in the year before and after installation of an ASHP across study units. The results will inform the utility and residents of documented energy and cost savings from transitioning building heating systems to a higher-efficiency electricity-based appliance, deliver a basis for building energy modeling across other multifamily housing dwellings, and enable estimates of potential electricity savings to AELP grid under widespread adoption scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extended Plate Wall System Expands Adoption of High-R Envelope Solutions

For decades, the residential building industry has worked to expand opportunities to increase the thermal resistance of walls. Multiple high-R wall construction methods have been developed, yet market adoption remains low because of perceived complexity and cost. One appealing solution is an extended plate wall system (EPW). Framing for top and bottom plates is one nominal dimension larger than for studs, which provides space for a 2-inch layer of foam plastic insulative sheathing (FPIS). Wood structural sheathing (OSB or plywood) is then installed on the exterior, fastened directly to the plates and nailed through the foam to the studs. In contrast to the conventional method of installing FPIS as a fully exterior layer, the EPW greatly simplifies air sealing, installation and detailing of windows and doors, an application of a weather resistive barrier, and attachment of cladding.

Building America↗

Extended Plate Wall System Expands Adoption of High-R Envelope Solution

For decades, the residential building industry has worked to expand opportunities to increase the thermal resistance of walls. Multiple high-R wall construction methods have been developed, yet market adoption remains low because of perceived complexity and cost. One appealing solution is an extended plate wall system (EPW). Framing for top and bottom plates is one nominal dimension larger than for studs, which provides space for a 2-inch layer of foam plastic insulative sheathing (FPIS). Wood structural sheathing (OSB or plywood) is then installed on the exterior, fastened directly to the plates and nailed through the foam to the studs. In contrast to the conventional method of installing FPIS as a fully exterior layer, the EPW greatly simplifies air sealing, installation and detailing of windows and doors, an application of a weather resistive barrier, and attachment of cladding.

30 DIRECT ENERGY CONVERSION↗

Techno-Economic Analysis for GTI's Compact Hydrogen Generator

A technoeconomic analysis of the compact hydrogen generator compared to a traditional steam methane reformer (SMR) was performed for both processes with and without carbon capture. The project goal for the technoeconomic analysis was to demonstrate a minimum of 20% lower CAPEX and 15% lower levelized cost of hydrogen compared to SMR with and without carbon capture. GTI obtained baseline capital and costs for the SMR with and without and methodology to calculate the levelized cost of hydrogen from an IEAGHG Technical Report: 2017-02 Techno-Economic Evaluation of SMR Based Standalone (Merchant) Hydrogen Plant with CCS. This methodology was then applied to GTI’s compact hydrogen generator using direct material costs previously obtained from a reputable engineering procurement and construction company, CB&I Howe-Baker. The analysis was performed for plants producing 90MMSCFD (million standard cubic feed per day) of hydrogen. Direct material costs were converted to total installed costs and total capital requirements using the same multiplying factors for both processes. We have found that the direct materials cost of the compact hydrogen generator is less than half the direct materials cost required for SMR without capture, and about one quarter the direct materials cost of SMR with carbon capture. This low materials cost translates into a significant CAPEX savings and lower levelized cost of hydrogen that exceed the goals of the techno-economic assessment. We have found that the CHG has a 43% lower installed cost and capital requirement compared to SMR without capture, that results in a levelized cost of hydrogen that is 19% lower than SMR. When 90% CO2 capture is added to the plants, the advantages is even better. The CHG has a 51% lower installed and capital requirement compared to SMR with capture, resulting in a 28% lower levelized cost of hydrogen. A sensitivity analysis was performed and showed natural gas feedstock cost and discount rate to be the main contributors to hydrogen price sensitivity. Given these significant cost advantages, GTI is encouraged to continue to develop the technology and market the economic advantages as well as the efficiency gains and ability to inherently capture CO2.

08 HYDROGEN↗

Benefits and risks of lead halide perovskite photovoltaics

Photovoltaics (PV) do not emit anything during operation, but, over their life-cycle, emissions are generated from the use of fossil-fuels in the extraction and production of materials and in the manufacturing and installation of PV components and systems. Nonetheless, these emissions are always very small compared to those from conventional combustion-based generators of electricity. The case for CO2 emissions has been well documented; over their lifetime, they range from 10 g CO2-eq / kWh for CdTe PV system installed in high-irradiation (2300 kWh/(m2-yr) locations to 80 g CO2-eq / kWh for Chinese single-crystalline silicon PV systems installed in low-irradiation (1000 kWh/(m2-yr) locations,1 compared to ~1000 g CO2-eq/kWh for electricity from coal. However, in the case of the rapidly emerging lead halide perovskite PV (LHP-PV) technology, concerns are raised regarding the potential of emissions of lead from the life-cycles of LHP-PV, including at their end of life. This warranted an evaluation of lead emissions from PV and comparisons with emissions in other power generation life-cycles.

Perovskites, PV, Lead, Risks↗

Evaluation of Centralized Model-Based FLISR in a Lab Setup: Preprint

Utilities are installing advanced distribution management systems (ADMS) around the globe to improve the sensing and control of distribution systems. ADMS is becoming a critical component to improve the resiliency and reliability of distribution systems. These management systems host a multitude of applications that can be used to sense, control, and operate distribution systems. Fault location, isolation, and service restoration (FLISR) is one of the ADMS applications that is critical to improving resilience during fault conditions. FLISR applications use smart, controllable devices that are installed in the distribution system for FLISR operation. These controllable devices include distributed energy resources (DER) and reclosers. Evaluating such ADMS applications before installation in the field can help de-risk the field implementation and avoid costly failures in the field. This paper presents a background on experimental setup that are typically used to evaluate ADMS applications. This is followed by briefly presenting the setup used to evaluate the FLISR application in an off-the-shelf ADMS tool. Finally, results from the evaluation experiments are presented.

94 GMLC - Grid Modernization Laboratory Consortium↗

Pilot-Scale Testing of an Integrated Circuit for the Extraction of Rare Earth Minerals and Elements from Coal and Coal Byproducts Using Advanced Separation Technologies

The primary objective of this project was to develop and demonstrate an integrated pilot-scale circuitry for recovering high-value rare earth elements (REEs) from coal and coal byproducts. The target performance was to produce a mixed REE product with content of at least two percent by weight on a dry mass basis in a cost-effective and environmentally benign manner. During the first nine months of the project period (Phase 2 Budget Period 2), pilot plant construction was completed including all field site startup activities such as permitting, engineering design, procurement/bidding, unit fabrication, site construction, equipment installation, module assembly, safety training, and circuit shakedown. During the remaining 21 months of project period (Phase 2 Budget Period 3), detailed field-testing activities were performed including feedstock sample collection and preparation, exploratory testing, circuit modification, detailed parametric study, and performance optimization. A detailed techno-economic analysis was performed based on the pilot plant testing findings which provided various scenarios for REE production. The project successfully accomplished the proposed target performance by producing mixed rare earth oxide (REO) with greater than 90% purity by weight in a continuous pilot scale operation from two distinctly different coarse refuse materials (i.e., West Kentucky No. 13 and Fire Clay coal seams), and at least three secondary sources (i.e., heap leach process and naturally formed acid mine drainage system). Project partners included the University of Kentucky, Virginia Tech, West Virginia University, Alliance Coal, Blackhawk Mining, Mineral Refining Company, and Mineral Separation Technologies. The pilot scale test facility was constructed at a former mining complex owned by Alliance Natural Resource Partners (Alliance Coal). The site was rehabilitated to accommodate the equipment installation, construction and fabrication, electrical power requirement, water line management and containment. The process units constructed and installed included X-ray sorting unit, crushing and grinding unit, physical separation unit, acid leaching unit, solvent extraction unit, and wastewater management unit. A rare earth mineral concentration unit was constructed as a standalone unit for flexible operation. A detailed environmental assessment and control plan was carried out to identify and quantify any potential impacts of the pilot-scale processing circuitry on the human and eco-system health and well-being. Corresponding mitigation strategies and control measures were provided. A conceptual flowsheet was developed to effectively remove thorium and uranium from high purity rare earth oxide mix or any potential radionuclide enriched stream. The two distinct feedstock materials were secured from the Blackhawk Mining Complex in eastern Kentucky where the Fire Clay (Hazard No. 4) seam is processed. The West Kentucky No. 13 (Baker) coarse refuse material was collected from an active process stream at an Alliance coal preparation plant located in western Kentucky. Characterization analysis indicated that both of feed materials generated from the two sources contained >300 ppm of TREEs on a dry whole mass basis which met the requirements for a qualified feed stock. The two feedstocks were further upgraded using a dual x-ray sorter to prepare the feed material for hydrometallurgical circuit. Thermal treatment on feed material prior to leaching was found to: 1) improve the leaching recovery of REEs, 2) increase the leaching kinetics, and 3) allow the leaching reaction to occur at lower acidity. Roasting at 600°C was selected as the pre-treatment condition for both West Kentucky No. 13 and Fire Clay coarse refuse material. Over 40% of leaching recovery was achieved by roasting West Kentucky No. 13 material having a top particle size of 3 mm in the pilot scale operation using 1.2M sulfuric acid leaching at 75OC. Initial pilot scale testing involved continuous operation of the pilot plant for 94 hours. The leaching unit was operated at solid-to-liquid ratio of 1 to 10 (w/v) using 0.5M sulfuric acid solution at a temperature of 75°C. The continuous solvent extraction circuit utilized rougher and cleaner units with DEHPA and TBP as the extractants. An innovative stripping circuit was developed to accumulate the REE concentration in the stripping solution to a level above 600 ppm. A bleed stream from the recycled strip solution was treated using oxalic acid precipitation which produced a high grade rare earth oxalate. The oxalate product was roasted to remove the oxalate which produced a rare earth oxide product having a purity greater 90%. Due to high concentrations of contaminant ions in the pregnant leach solution (PLS), a modified flowsheet was developed that involved pre-concentration of the REEs using multiple stages of precipitation and redissolution. The advantage of this process was improved removal of contamination before the downstream purification process and a significant cost reduction relative to the circuit that utilized the solvent extraction process. The modified circuitry included processes involving leaching, multistage precipitation, redissolution, and oxalate precipitation followed by roasting of the oxalate product. The circuit produced a mixed REO that was 92.96% pure from the initial test. A detailed parametric test plan was carried out which involved varying key parameters including solids feed rate, acid flowrate, acid concentration, multistage precipitation pH, redissolution pH, oxalate precipitation dosage and pH. The response variables included REE recovery, contaminant recovery, REO product grade and overall chemical consumption. Test results indicated that the acid-to-solid ratio is the key parameter to leaching efficiency as performance deteriorated with an increase in solids concentration. The optimal pH determined for REE precipitation and redissolution was 6.5 and 2.5, respectively. Additional tests were conducted to further improve the flowsheet. Recirculating a portion of the PLS to the feed of the leach tanks improved the leaching performance by lowering the pH of the leaching system and reducing the contamination recovery by shortening the residence time. Moreover, the removal of Al prior to REE precipitation significantly reduced the oxalic acid consumption in the oxalate precipitation circuit. The modified circuit produced over 90% grade REO by weight from both West Kentucky No. 13 and Fire Clay coarse refuse material in pilot scale continuous test programs. A case analysis model was developed to project the REE and major contaminants concentration in each PLS stream based on the leaching condition, pH cut point, and oxalic acid dosage. A correlation was established using empirical and semi-empirical models. Using the models, chemical consumption required for each stage was predicted based on the projected performance of the hydrometallurgy circuit. After identifying the optimum conditions, validation tests were carried out for the treatment of both West Kentucky No. 13 and Fire Clay coarse refuse materials in the pilot plant. The actual circuit performance and chemical consumptions were very close to the model predictions. Other than the two coarse refuse sources, several secondary feedstocks were also tested in the pilot plant facility. A “heap leach” system was constructed using the coarse refuse material generated from cleaning the West Kentucky No. 13 seam coal. Using the two stage SX rougher and cleaner circuit, a concentrate with a grade >90% REO was produced while recovering >97% of the REEs from the heap leach PLS. Naturally generated acid mine drainage (AMD) from West Kentucky No.13 mine was processed using the multistage precipitation circuit in the pilot plant in a test conducted for a period of 32 hours. The final grade of the mix RE oxide produced from the AMD was 90.84% with an overall circuit recovery of 64%. The primary source of REE was the selective precipitation steps involving iron and aluminum rejection. The hydrophobic-hydrophilic separation (HHS) process was proven to effectively recover coal from fine waste materials. For REM recovery, the HHS process was able to produce concentrates at grades of approximately 1.8% REE on an ash basis; however, recovery values were typically low, <10%, under the optimal conditions determined in the laboratory-scale testing. Staged testing of the pilot-scale HHS process for coal recovery and semi-continuous laboratory testing for REM testing showed that a total concentration ratio of more than 15x was observed for the REM recovery process. A circuit simulation package was developed for REE extraction and purification using a spreadsheet-based platform (Microsoft Excel). The REESim circuit simulation package is configured to track the mass and volume flows of components passing through a series of unit operations specified and configured by the user. The mass rates can then be utilized by the user to determine important performance indicators such as product mass yields, concentrate purity levels, element-by-element recoveries, and so forth. The techno-economic analysis showed that the roasting and leaching operations were the most expensive capital items, each contributing approximately 30% to the total capital cost. One notable contributor to the high production costs was the low REE recovery observed in the pilot scale trials. The product basket price was shown to have a strong influence on the economic viability of the scenarios, with the scandium price being the most significant influencer. Operating cost was shown to be extremely sensitive to REE recovery, REE feed grade, and leaching acid consumption. An analysis of ten different scenarios for a 500 t/h commercial operation revealed that three were economically favorable, producing internal rates of return varying from 27.7% to 33.1% and payback periods of 4 to 5 years. The project successfully developed and demonstrated a process to recover REEs from coal and coal byproducts in a pilot-plant operation which consistently produced over 90% grade REO mix from varies types of feedstocks. Commercialization analysis showed that the technology readiness level successfully achieved TRL 6 at the end of the project and demonstrated the need and the potential for scaling the process to further advance the technologies toward the goal of providing a domestic supply of REEs at a commercial scale.

01 COAL, LIGNITE, AND PEAT↗

Performance Considerations for Ground Source Heat Pumps in Cold Climates: Preprint

Remote, cold climates present challenges to finding safe and affordable options to heat homes. In Alaska, residential ground source heat pumps (GSHPs) have been gaining in popularity to fill this gap. However, there is little research on their long-term performance or effect on soil temperatures. The extended heating season and cold soils of Alaska provide a harsh testing ground for GSHPs, even those designed and marketed for colder climates. The large and unbalanced heating load of cold climates creates a challenging environment for GSHPs. In 2013 the Cold Climate Housing Research Center (CCHRC) installed a GSHP at its Research and Testing Facility (RTF) in Fairbanks, Alaska. The heat pump replaced an oil-fired condensing boiler heating a 464 m2 office space via an in-floor hydronic radiant heating system. The ground heat exchanger (GHE) was installed in moisture-rich silty soils underlain with permafrost near 0°C. The intent of the installation was to observe and monitor the system over a 10-year period in order to develop a better understanding of the performance of GSHPs in sites with permafrost and to help inform future design. As of this writing, the heat pump system has been running for seven heating seasons. The efficiency in those seven heating seasons has been variable with ups and downs that have been difficult to explain. This paper seeks to understand the variability in performance as well as make recommendations for GSHP use in other cold climates.

cold climate↗

Integrated and Advanced Lighting Controls: The Next Frontier in Energy Savings?

Lighting energy use has significantly declined as a portion of overall building energy usage due largely to the uptake of more efficient light-emitting diode technology. Although the per unit cost of lighting controls has declined, the installation and use of lighting controls are low and the installation and use of advanced controls are abysmally low. Increased use of advanced and connected lighting controls, and the ability to integrate lighting with other building systems (e.g., heat and air, plug loads, miscellaneous loads) that make the building “smarter,” offer the potential for additional energy savings. Studies into the performance of new, advanced lighting control technologies in commercial buildings have generated new findings. Although each field evaluation has interesting results individually, an analysis of their collective findings across a spectrum of commercial building types will help establish the current state of the technology and implications related to market readiness. This paper will analyze results from available field evaluation studies (recently completed as well as ongoing) of retrofit sites and share findings and insights including: • The amount of energy savings that may be expected from these systems. • Cost effectiveness, monetization, and cost points of these systems. • Ideal characteristics of these systems the most viable. • Lessons learned from the installation, commissioning, and occupant response of these systems. The results will support Department of Energy research investments and help inform efficiency programs of the potential of these emerging technologies and how they may fit within the clean energy future.

Myer, Michael↗