Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Development of a phase contrast imaging system based on a yttrium aluminum garnet laser with folded beam for observations of density fluctuations in compact helical system

A near-infrared laser phase contrast optical system incorporating a folded beam was developed in order to measure the distribution of density fluctuations in a high-temperature plasma. The coherent light source used was an yttrium aluminum garnet laser stabilized by a ring oscillator. The probe beam system separates and reflects the incident and exiting beams with a polarizer and a fully reflective mirror with a waveplate. This system was employed with a compact helical system to detect fluctuations at the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tomographic imaging system for measuring impurity line emission in a field-reversed configuration

A 16 chord optical tomography system has been developed and implemented in the flux coil generated-field reversed configuration (FRC). The chords are arranged in two fans of eight, which cover {approx}35% of the vessel area at the midplane. Each illuminate separate photomultiplier tubes (PMTs) which are fitted with narrow band-pass filters. In this case, filters are centered at 434.8 nm to measure emission from singly ionized argon. PMT crosstalk is negligible. Background noise due to electron radiation and H{sub {gamma}} line radiation is <10% of argon emission. The spatial resolution of the reconstruction is 1.5 cm. Argon is introduced using a puff valve and tube designed to impart the gas into the system as the FRC is forming. Reconstruction of experimental data results in time-dependent, 2D emissivity profiles of the impurity ions. Analysis of these data show radial, cross-field diffusion to be in the range of 10-10{sup 3} m{sup 2}/s during FRC equilibrium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a 3-D visible limiter imaging system for the HSX stellarator

A visible camera diagnostic has been developed to study the Helically Symmetric eXperiment (HSX) limiter plasma interaction. A straight line view from the camera location to the limiter was not possible due to the complex 3D stellarator geometry of HSX, so it was necessary to insert a mirror/lens system into the plasma edge. A custom support structure for this optical system tailored to the HSX geometry was designed and installed. This system holds the optics tube assembly at the required angle for the desired view to both minimize system stress and facilitate robust and repeatable camera positioning. The camera system has been absolutely calibrated and using H α and C-III filters can provide hydrogen and carbon photon fluxes, which through an S/XB coefficient can be converted into particle fluxes. The resulting measurements have been used to obtain the characteristic penetration length of hydrogen and C-III species. Here, the hydrogen λ iz value shows reasonable agreement with the value predicted by a 1D penetration length calculation.

47 OTHER INSTRUMENTATION↗

Infrared imaging systems for wall protection in the W7-X stellarator (invited)

Here, Wendelstein 7-X aims at quasi-steady state operation with up to 10 MW of heating power for 30 min. Power exhaust will be handled predominantly via 10 actively water cooled CFC (carbon-fiber-reinforced carbon) based divertor units designed to withstand power loads of 10 MW/m 2 locally in steady state. If local loads exceed this value, a risk of local delamination of the CFC and failure of entire divertor modules arises. Infrared endoscopes to monitor all main plasma facing components are being prepared, and near real time software tools are under development to identify areas of excessive temperature rise, to distinguish them from non-critical events, and to trigger alarms. Tests with different cameras were made in the recent campaign. Long pulse operation enforces additional diagnostic design constraints: for example, the optics need to be thermally decoupled from the endoscope housing. In the upcoming experimental campaign, a graphite scraper element, in front of the island divertor throat, will be tested as a possible means to protect the divertor pumping gap edges during the transient discharge evolution.

47 OTHER INSTRUMENTATION↗

A Pixel Readout Chip in 40 nm CMOS Process for High Count Rate Imaging Systems with Minimization of Charge Sharing Effects

We present a prototype chip in 40 nm CMOS technology for readout of hybrid pixel detector. The prototype chip has a matrix of 18x24 pixels with a pixel pitch of 100 μm. It can operate both in single photon counting (SPC) mode and in C8P1 mode. In SPC the measured ENC is 84 e ₋ rms (for the peaking time of 48 ns), while the effective offset spread is below 2 mV rms. In the C8P1 mode the chip reconstructs full charge deposited in the detector, even in the case of charge sharing, and it identifies a pixel with the largest charge deposition. The chip architecture and preliminary measurements are reported.

Rad Hard Vertex Detector↗

Poster – 13: Evaluation of an in-house CCD camera film dosimetry imaging system for small field deliveries

Purpose: Radiochromic film dosimetry is a standard technique used in clinics to verify modern conformal radiation therapy delivery, and sometimes in research to validate other dosimeters. We are using film as a standard for comparison as we improve high-resolution three-dimensional gel systems for small field dosimetry; however, precise film dosimetry can be technically challenging. We report here measurements for fractionated stereotactic radiation therapy (FSRT) delivered using volumetric modulated arc therapy (VMAT) to investigate the accuracy and reproducibility of film measurements with a novel in-house readout system. We show that radiochromic film can accurately and reproducibly validate FSRT deliveries and also benchmark our gel dosimetry work. Methods: VMAT FSRT plans for metastases alone (PTV{sub MET}) and whole brain plus metastases (WB+PTV{sub MET}) were delivered onto a multi-configurational phantom with a sheet of EBT3 Gafchromic film inserted mid-plane. A dose of 400 cGy was prescribed to 4 small PTV{sub MET} structures in the phantom, while a WB structure was prescribed a dose of 200 cGy in the WB+PTV{sub MET} iterations. Doses generated from film readout with our in-house system were compared to treatment planned doses. Each delivery was repeated multiple times to assess reproducibility. Results and Conclusions: The reproducibility of film optical density readout was excellent throughout all experiments. Doses measured from the film agreed well with plans for the WB+PTV{sub MET} delivery. But, film doses for PTV{sub MET} only deliveries were significantly below planned doses. This discrepancy is due to stray/scattered light perturbations in our system during readout. Corrections schemes will be presented.

60 APPLIED LIFE SCIENCES↗

The Eagle ALDRIS (Agile Low-Does Radiographic Imaging System)

The overall project was to design a mobile (truck-based) cargo scanning system that can be deployed at different stations according to need. In addition, the project would optimize the use of the electron beam thereby reducing the overall radiation produced and to help make the radiation shielding lighter. The SLAC work for this project done through this CRADA was to design the beam-line from the output of the alpha-magnet at the end of the Varian linac to the photon production target. The beam is required to hit the photon production target at the same point but with a range of vertical angles from +/- 25°. In addition, the scope of work by SLAC was to provide an alternate design for the linac based on new linac and RF source technology developed at SLAC.

43 PARTICLE ACCELERATORS↗