Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Reconstruction Techniques for Sparse Multistatic Linear Array Microwave Imaging

Sequentially-switched linear arrays are an enabling technology for a number of near-field microwave imaging applications. Electronically sequencing along the array axis followed by mechanical scanning along an orthogonal axis allows dense sampling of a two-dimensional aperture in near real-time. In this paper, a sparse multi-static array technique will be described along with associated Fourier-Transform-based and back-projection-based image reconstruction algorithms. Simulated and measured imaging results are presented that show the effectiveness of the sparse array technique along with the merits and weaknesses of each image reconstruction approach.

concealed-weapon detection↗

Detection of Obstacles in Monocular Image Sequences

The ability to detect and locate runways/taxiways and obstacles in images captured using on-board sensors is an essential first step in the automation of low-altitude flight, landing, takeoff, and taxiing phase of aircraft navigation. Automation of these functions under different weather and lighting situations, can be facilitated by using sensors of different modalities. An aircraft-based Synthetic Vision System (SVS), with sensors of different modalities mounted on-board, complements the current ground-based systems in functions such as detection and prevention of potential runway collisions, airport surface navigation, and landing and takeoff in all weather conditions. In this report, we address the problem of detection of objects in monocular image sequences obtained from two types of sensors, a Passive Millimeter Wave (PMMW) sensor and a video camera mounted on-board a landing aircraft. Since the sensors differ in their spatial resolution, and the quality of the images obtained using these sensors is not the same, different approaches are used for detecting obstacles depending on the sensor type. These approaches are described separately in two parts of this report. The goal of the first part of the report is to develop a method for detecting runways/taxiways and objects on the runway in a sequence of images obtained from a moving PMMW sensor. Since the sensor resolution is low and the image quality is very poor, we propose a model-based approach for detecting runways/taxiways. We use the approximate runway model and the position information of the camera provided by the Global Positioning System (GPS) to define regions of interest in the image plane to search for the image features corresponding to the runway markers. Once the runway region is identified, we use histogram-based thresholding to detect obstacles on the runway and regions outside the runway. This algorithm is tested using image sequences simulated from a single real PMMW image.

Kasturi, Rangachar↗

Remote Sensing Time Series Product Tool

The TSPT (Time Series Product Tool) software was custom-designed for NASA to rapidly create and display single-band and band-combination time series, such as NDVI (Normalized Difference Vegetation Index) images, for wide-area crop surveillance and for other time-critical applications. The TSPT, developed in MATLAB, allows users to create and display various MODIS (Moderate Resolution Imaging Spectroradiometer) or simulated VIIRS (Visible/Infrared Imager Radiometer Suite) products as single images, as time series plots at a selected location, or as temporally processed image videos. Manually creating these types of products is extremely labor intensive; however, the TSPT development tool makes the process simplified and efficient. MODIS is ideal for monitoring large crop areas because of its wide swath (2330 km), its relatively small ground sample distance (250 m), and its high temporal revisit time (twice daily). Furthermore, because MODIS imagery is acquired daily, rapid changes in vegetative health can potentially be detected. The new TSPT technology provides users with the ability to temporally process high-revisit-rate satellite imagery, such as that acquired from MODIS and from its successor, the VIIRS. The TSPT features the important capability of fusing data from both MODIS instruments onboard the Terra and Aqua satellites, which drastically improves cloud statistics. With the TSPT, MODIS metadata is used to find and optionally remove bad and suspect data. Noise removal and temporal processing techniques allow users to create low-noise time series plots and image videos and to select settings and thresholds that tailor particular output products. The TSPT GUI (graphical user interface) provides an interactive environment for crafting what-if scenarios by enabling a user to repeat product generation using different settings and thresholds. The TSPT Application Programming Interface provides more fine-tuned control of product generation, allowing experienced programmers to bypass the GUI and to create more user-specific output products, such as comparison time plots or images. This type of time series analysis tool for remotely sensed imagery could be the basis of a large-area vegetation surveillance system. The TSPT has been used to generate NDVI time series over growing seasons in California and Argentina and for hurricane events, such as Hurricane Katrina.

Predos, Don↗

MO-G-BRF-02: Enhancement of Texture-Based Metastasis Prediction Models Via the Optimization of PET/MRI Acquisition Protocols

Purpose: We have previously identified a prediction model of lung metastases at diagnosis of soft-tissue sarcomas (STS) that is composed of two textural features extracted from FDG-PET and T1-weighted (T1w) MRI scans. The goal of this study is to evaluate whether the optimization in FDGPET and MRI acquisition parameters would enhance the prediction performance of texture-based models. Methods: Ten FDG-PET and T1w- MRI digitized tumor models were generated from imaging data of STS patients who underwent pre-treatment clinical scans between 2005 and 2011. Five of ten patients eventually developed lung metastases. Numerically simulated MR images were produced using echo times (TE) of 2 and 4 times the nominal clinical parameter (TEc), and repetition times (TR) of 0.5, 0.67, 1.5 and 2 times the nominal clinical parameter (TRc) found in the DICOM headers (TEc range: 9–13 ms, TRc range: 410-667 ms). PET 2D images were simulated using Monte-Carlo and were reconstructed using an ordered-subsets expectation maximization (OSEM) algorithm with 1 to 32 iterations and a post-reconstruction Gaussian filter of 0, 2, 4 or 6 mm width. For all possible combinations of PET and MRI acquisition parameters, the prediction model was constructed using logistic regression with new coefficients, and its associated prediction performance for lung metastases was evaluated using the area under the ROC curve (AUC). Results: The prediction performance over all simulations yielded AUCs ranging from 0.7 to 1. Notably, TR values below or equal to TRc and higher PET post-reconstruction filter widths yielded higher prediction performance. The best results were obtained with a combination of 4*TEc, TRc, 30 OSEM iterations and 2mm filter width. Conclusion: This work indicates that texture-based metastasis prediction models could be improved using optimized choices of FDG-PET and MRI acquisition protocols. This principle could be generalized to other texture-based models.

60 APPLIED LIFE SCIENCES↗

Efficient linear phase contrast in scanning transmission electron microscopy with matched illumination and detector interferometry

The ability to image light elements in soft matter at atomic resolution enables unprecedented insight into the structure and properties of molecular heterostructures and beam-sensitive nanomaterials. In this study, we introduce a scanning transmission electron microscopy technique combining a pre-specimen phase plate designed to produce a probe with structured phase with a high-speed direct electron detector to generate nearly linear contrast images with high efficiency. We demonstrate this method by using both experiment and simulation to simultaneously image the atomic-scale structure of weakly scattering amorphous carbon and strongly scattering gold nanoparticles. Our method demonstrates strong contrast for both materials, making it a promising candidate for structural determination of heterogeneous soft/hard matter samples even at low electron doses comparable to traditional phase-contrast transmission electron microscopy. Ultimately, simulated images demonstrate the extension of this technique to the challenging problem of structural determination of biological material at the surface of inorganic crystals.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Computer Simulation of a Digital Global Velocimeter

The objective is to continue the development of a Monte-Carlo simulation of a Doppler Global Velocimetry (DGV) optical system starting with the Mie scattering from the particles in the fluid to the collection optics, through the beamsplitter, Iodine absorption cell and finally to the CCD sensor. The simulation program will read in a configuration file that completely describes the attributes of a DGV system (optical, physical layout, location of detectors, laser properties, CCD sensor noise characteristics...). The simulation program will output a set of images that simulate the data collected from a DGV system. NASA GRC has the DGV software developed at NASA Langley and this simulation program will prove invaluable for determining the accuracy of the DGV technique and provide insight into optimizing the data reduction techniques. The DGV simulation software will also prove valuable in a DDF funded projected entitled Planar Particle Imaging Doppler Velocimetry (PPIDV), which was recently awarded in March 2002.

Cheung, H. Mike↗

Panoramic cone beam computed tomography

Purpose: Cone-beam computed tomography (CBCT) is the main imaging tool for image-guided radiotherapy but its functionality is limited by a small imaging volume and restricted image position (imaged at the central instead of the treatment position for peripheral lesions to avoid collisions). In this paper, the authors present the concept of ''panoramic CBCT,'' which can image patients at the treatment position with an imaging volume as large as practically needed. Methods: In this novel panoramic CBCT technique, the target is scanned sequentially from multiple view angles. For each view angle, a half scan (180 deg. + {theta}{sub cone} where {theta}{sub cone} is the cone angle) is performed with the imaging panel positioned in any location along the beam path. The panoramic projection images of all views for the same gantry angle are then stitched together with the direct image stitching method (i.e., according to the reported imaging position) and full-fan, half-scan CBCT reconstruction is performed using the stitched projection images. To validate this imaging technique, the authors simulated cone-beam projection images of the Mathematical Cardiac Torso (MCAT) thorax phantom for three panoramic views. Gaps, repeated/missing columns, and different exposure levels were introduced between adjacent views to simulate imperfect image stitching due to uncertainties in imaging position or output fluctuation. A modified simultaneous algebraic reconstruction technique (modified SART) was developed to reconstruct CBCT images directly from the stitched projection images. As a gold standard, full-fan, full-scan (360 deg. gantry rotation) CBCT reconstructions were also performed using projection images of one imaging panel large enough to encompass the target. Contrast-to-noise ratio (CNR) and geometric distortion were evaluated to quantify the quality of reconstructed images. Monte Carlo simulations were performed to evaluate the effect of scattering on the image quality and imaging dose for both standard and panoramic CBCT. Results: Truncated images with artifacts were observed for the CBCT reconstruction using projection images of the central view only. When the image stitching was perfect, complete reconstruction was obtained for the panoramic CBCT using the modified SART with the image quality similar to the gold standard (full-scan, full-fan CBCT using one large imaging panel). Imperfect image stitching, on the other hand, lead to (streak, line, or ring) reconstruction artifacts, reduced CNR, and/or distorted geometry. Results from Monte Carlo simulations showed that, for identical imaging quality, the imaging dose was lower for the panoramic CBCT than that acquired with one large imaging panel. For the same imaging dose, the CNR of the three-view panoramic CBCT was 50% higher than that of the regular CBCT using one big panel. Conclusions: The authors have developed a panoramic CBCT technique and demonstrated with simulation data that it can image tumors of any location for patients of any size at the treatment position with comparable or less imaging dose and time. However, the image quality of this CBCT technique is sensitive to the reconstruction artifacts caused by imperfect image stitching. Better algorithms are therefore needed to improve the accuracy of image stitching for panoramic CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image processing methods used to simulate flight over remotely sensed data

It has been demonstrated that image processing techniques can provide an effective means of simulating flight over remotely sensed data (Hussey et al. 1986). This paper explains the methods used to simulate and animate three-dimensional surfaces from two-dimensional imagery. The preprocessing techniques used on the input data, the selection of the animation sequence, the generation of the animation frames, and the recording of the animation is covered. The software used for all steps is discussed.

Mortensen, H. B.↗

AAPM Truth‐based CT (TrueCT) reconstruction grand challenge

Background: This Special Report summarizes the 2022, AAPM grand challenge on Truth-based CT image reconstruction. Purpose: To provide an objective framework for evaluating CT reconstruction methods using virtual imaging resources consisting of a library of simulated CT projection images of a population of human models with various diseases. Methods: Two hundred unique anthropomorphic, computational models were created with varied diseases consisting of 67 emphysema, 67 lung lesions, and 66 liver lesions. The organs were modeled based on clinical CT images of real patients. The emphysematous regions were modeled using segmentations from patient CT cases in the COPDGene Phase I dataset. For the lung and liver lesion cases, 1–6 malignant lesions were created and inserted into the human models, with lesion diameters ranging from 5.6 to 21.9 mm for lung lesions and 3.9 to 14.9 mm for liver lesions. The contrast defined between the liver lesions and liver parenchyma was 82 ± 12 HU, ranging from 50 to 110 HU. Similarly, the contrast between the lung lesions and the lung parenchyma was defined as 781 ± 11 HU, ranging from 725 to 805 HU. For the emphysematous regions, the defined HU values were −950 ± 17 HU ranging from −918 to −979 HU. The developed human models were imaged with a validated CT simulator. The resulting CT sinograms were shared with the participants. The participants reconstructed CT images from the sinograms and sent back their reconstructed images. Further, the reconstructed images were then scored by comparing the results against the corresponding ground truth values. The scores included both task-generic (root mean square error [RMSE] and structural similarity matrix [SSIM]), and task-specific (detectability index [d’] and lesion volume accuracy) metrics. For the cases with multiple lesions, the measured metric was averaged across all the lesions. To combine the metrics with each other, each metric was normalized to a range of 0 to 1 per disease type, with “0” and “1” being the worst and best measured values across all cases of the disease type for all received reconstructions. Results: The True-CT challenge attracted 52 participants, out of which 5 successfully completed the challenge and submitted the requested 200 reconstructions. Across all participants and disease types, SSIM absolute values ranged from 0.22 to 0.90, RMSE from 77.6 to 490.5 HU, d’ from 0.1 to 64.6, and volume accuracy ranged from 1.2 to 753.1 mm3. The overall scores demonstrated that participant “A” had the best performance in all categories, except for the metrics of d’ for lung lesions and RMSE for liver lesions. Participant “A” had an average normalized score of 0.41 ± 0.22, 0.48 ± 0.32, and 0.42 ± 0.33 for the emphysema, lung lesion, and liver lesion cases, respectively. Conclusions: The True-CT challenge successfully enabled objective assessment of CT reconstructions with the unique advantage of access to a diverse population of diseased human models with known ground truth. This study highlights the significant potential of virtual imaging trials in objective assessment of medical imaging technologies.

60 APPLIED LIFE SCIENCES↗

A simulation pipeline for fast neutron imaging and spectroscopy using quantified detector attributes

Radiation imaging capabilities, essential in the nuclear nonproliferation regime, facilitate source localization and, in certain cases, spectroscopy. Scatter-based neutron cameras, which can measure the neutron signatures from special nuclear material, hold particular interest. Systems incorporating organic scintillators can extract neutron energy spectra, potentially distinguishing fission neutron sources from others, such as alpha-neutron sources. The development and testing of a scatter-based neutron imager, however, can be challenging without having an accurate simulation model or first constructing a prototype. This work describes a simulation pipeline that takes output from MCNPX-PoliMi simulations and creates the expected back-projection neutron images and neutron energy spectra. This pipeline was developed to improve the modeling of fast neutron imagers and bridge the current gap in literature, which predominantly focuses on gamma-ray Compton imager models. This work also reports on the significance of various real-world system considerations and their effects on the simulated detector responses. The pipeline was verified and validated with experimental data collected using a 252 Cf spontaneous fission source using a fast neutron scattering imager developed at the University of Michigan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heteroepitaxial growth and surface structure of L1 0 -MnGa(111) ultra-thin films on GaN(0001)

L1 0 -structured MnGa(111) ultra-thin films were heteroepitaxially grown on GaN(0001) under lightly Mn-rich conditions using molecular beam epitaxy. Room-temperature scanning tunneling microscopy (STM) investigations reveal smooth terraces and angular step edges, with the surface structure consisting primarily of a 2x2 reconstruction along with small patches of 1x2. Theoretical calculations were undertaken using density functional theory, and the simulated STM images were calculated using the Tersoff-Hamann approximation, demonstrating that a stoichiometric 1x2 and a Mn-rich 2x2 surface structure give the best agreement with the observed experimental images.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Repulsive tip tilting as the dominant mechanism for hydrogen bond-like features in atomic force microscopy imaging

Experimental atomic force microscopy (AFM) studies have reported distinct features in regions with little electron density for various organic systems. These unexpected features have been proposed to be a direct visualization of intermolecular hydrogen bonding. Here, we apply a computational method using ab initio real-space pseudopotentials along with a scheme to account for tip tilting to simulate AFM images of the 8-hydroxyquinoline dimer and related systems to develop an understanding of the imaging mechanism for hydrogen bonds. We find that contrast for the observed “hydrogen bond” feature comes not from the electrostatic character of the bonds themselves but rather from repulsive tip tilting induced by neighboring electron-rich atoms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MO-G-17A-04: Internal Dosimetric Calculations for Pediatric Nuclear Imaging Applications, Using Monte Carlo Simulations and High-Resolution Pediatric Computational Models

Purpose: Our purpose is to evaluate the administered absorbed dose in pediatric, nuclear imaging studies. Monte Carlo simulations with the incorporation of pediatric computational models can serve as reference for the accurate determination of absorbed dose. The procedure of the calculated dosimetric factors is described, while a dataset of reference doses is created. Methods: Realistic simulations were executed using the GATE toolkit and a series of pediatric computational models, developed by the “IT'IS Foundation”. The series of the phantoms used in our work includes 6 models in the range of 5–14 years old (3 boys and 3 girls). Pre-processing techniques were applied to the images, to incorporate the phantoms in GATE simulations. The resolution of the phantoms was set to 2 mm3. The most important organ densities were simulated according to the GATE “Materials Database”. Several used radiopharmaceuticals in SPECT and PET applications are being tested, following the EANM pediatric dosage protocol. The biodistributions of the several isotopes used as activity maps in the simulations, were derived by the literature. Results: Initial results of absorbed dose per organ (mGy) are presented in a 5 years old girl from the whole body exposure to 99mTc - SestaMIBI, 30 minutes after administration. Heart, kidney, liver, ovary, pancreas and brain are the most critical organs, in which the S-factors are calculated. The statistical uncertainty in the simulation procedure was kept lower than 5%. The Sfactors for each target organ are calculated in Gy/(MBq*sec) with highest dose being absorbed in kidneys and pancreas (9.29*10{sup 10} and 0.15*10{sup 10} respectively). Conclusion: An approach for the accurate dosimetry on pediatric models is presented, creating a reference dosage dataset for several radionuclides in children computational models with the advantages of MC techniques. Our study is ongoing, extending our investigation to other reference models and evaluating the results with clinical estimated doses.

60 APPLIED LIFE SCIENCES↗

GREAT3 results - I. Systematic errors in shear estimation and the impact of real galaxy morphology

The study present first results from the third GRavitational lEnsing Accuracy Testing (GREAT3) challenge, the third in a sequence of challenges for testing methods of inferring weak gravitational lensing shear distortions from simulated galaxy images. GREAT3 was divided into experiments to test three specific questions, and included simulated space- and ground-based data with constant or cosmologically varying shear fields. The simplest (control) experiment included parametric galaxies with a realistic distribution of signal-to-noise, size, and ellipticity, and a complex point spread function (PSF). The other experiments tested the additional impact of realistic galaxy morphology, multiple exposure imaging, and the uncertainty about a spatially varying PSF; the last two questions will be explored in Paper II. The 24 participating teams competed to estimate lensing shears to within systematic error tolerances for upcoming Stage-IV dark energy surveys, making 1525 submissions overall. GREAT3 saw considerable variety and innovation in the types of methods applied. Several teams now meet or exceed the targets in many of the tests conducted (to within the statistical errors). We conclude that the presence of realistic galaxy morphology in simulations changes shear calibration biases by ~1 per cent for a wide range of methods. Other effects such as truncation biases due to finite galaxy postage stamps, and the impact of galaxy type as measured by the Sérsic index, are quantified for the first time. Our results generalize previous studies regarding sensitivities to galaxy size and signal-to-noise, and to PSF properties such as seeing and defocus. Almost all methods’ results support the simple model in which additive shear biases depend linearly on PSF ellipticity.

79 ASTRONOMY AND ASTROPHYSICS↗

Strong Lensing Parameter Estimation on Ground-Based Imaging Data Using Simulation-Based Inference

Current ground-based cosmological surveys, such as the Dark Energy Survey (DES), are predicted to discover thousands of galaxy-scale strong lenses, while future surveys, such as the Vera Rubin Observatory Legacy Survey of Space and Time (LSST) will increase that number by 1-2 orders of magnitude. The large number of strong lenses discoverable in future surveys will make strong lensing a highly competitive and complementary cosmic probe. To leverage the increased statistical power of the lenses that will be discovered through upcoming surveys, automated lens analysis techniques are necessary. We present two Simulation-Based Inference (SBI) approaches for lens parameter estimation of galaxy-galaxy lenses. We demonstrate the successful application of Neural Posterior Estimation (NPE) to automate the inference of a 12-parameter lens mass model for DES-like ground-based imaging data. We compare our NPE constraints to a Bayesian Neural Network (BNN) and find that it outperforms the BNN, producing posterior distributions that are for the most part both more accurate and more precise; in particular, several source-light model parameters are systematically biased in the BNN implementation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave Imaging Reflectometry for the study of Edge Harmonic Oscillations on DIII-D [Microwave Imaging Reflectometry (MIR) for the study of Edge Harmonic Oscillations (EHOs) on DIII-D]

Quiescent H-mode (QH) is an ELM free mode of operation in which edge-localized harmonic oscillations (EHOs) are believed to enhance particle transport, thereby stabilizing ELMs and preventing damage to the divertor and plasma facing components. Microwave Imaging Reflectometer (MIR) enabling direct comparison between the measured and simulated 2D images of density fluctuations near the edge can determine the 2D structure of density oscillation which can help to explain the physics behind EHO modes. MIR data sometimes indicates a counter-propagation between higher (n>1) and dominant (n=1) harmonics of coherent EHOs in the steep gradient regions of the pedestal. To preclude diagnostic artifacts, we have performed forward modeling that includes possible optical misalignments to show that offsets between transmitting and receiving antennas do not account for this feature. We have also simulated the non-uniform rotation of the EHO structure, which induces multiple harmonics that are properly characterized in the synthetic diagnostic. Excluding these possible explanations for the data, the counter-propagation observed in MIR data, which is not corroborated by external Mirnov coil array measurements, may be due to subtleties of the eigenmode structure, such as an inversion radius consistent with a magnetic island. Similar effects are observed in analysis of internal ECE-Imaging and BES data. Furthermore, the identification of a non-ideal structure motivates further exploration of nonlinear models of this instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo simulation of PET and SPECT imaging of {sup 90}Y

Purpose: Yittrium-90 ({sup 90}Y) is traditionally thought of as a pure beta emitter, and is used in targeted radionuclide therapy, with imaging performed using bremsstrahlung single-photon emission computed tomography (SPECT). However, because {sup 90}Y also emits positrons through internal pair production with a very small branching ratio, positron emission tomography (PET) imaging is also available. Because of the insufficient image quality of {sup 90}Y bremsstrahlung SPECT, PET imaging has been suggested as an alternative. In this paper, the authors present the Monte Carlo-based simulation–reconstruction framework for {sup 90}Y to comprehensively analyze the PET and SPECT imaging techniques and to quantitatively consider the disadvantages associated with them. Methods: Our PET and SPECT simulation modules were developed using Monte Carlo simulation of Electrons and Photons (MCEP), developed by Dr. S. Uehara. PET code (MCEP-PET) generates a sinogram, and reconstructs the tomography image using a time-of-flight ordered subset expectation maximization (TOF-OSEM) algorithm with attenuation compensation. To evaluate MCEP-PET, simulated results of {sup 18}F PET imaging were compared with the experimental results. The results confirmed that MCEP-PET can simulate the experimental results very well. The SPECT code (MCEP-SPECT) models the collimator and NaI detector system, and generates the projection images and projection data. To save the computational time, the authors adopt the prerecorded {sup 90}Y bremsstrahlung photon data calculated by MCEP. The projection data are also reconstructed using the OSEM algorithm. The authors simulated PET and SPECT images of a water phantom containing six hot spheres filled with different concentrations of {sup 90}Y without background activity. The amount of activity was 163 MBq, with an acquisition time of 40 min. Results: The simulated {sup 90}Y-PET image accurately simulated the experimental results. PET image is visually superior to SPECT image because of the low background noise. The simulation reveals that the detected photon number in SPECT is comparable to that of PET, but the large fraction (approximately 75%) of scattered and penetration photons contaminates SPECT image. The lower limit of {sup 90}Y detection in SPECT image was approximately 200 kBq/ml, while that in PET image was approximately 100 kBq/ml. Conclusions: By comparing the background noise level and the image concentration profile of both the techniques, PET image quality was determined to be superior to that of bremsstrahlung SPECT. The developed simulation codes will be very useful in the future investigations of PET and bremsstrahlung SPECT imaging of {sup 90}Y.

07 ISOTOPE AND RADIATION SOURCES↗