Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Neutron-Friendly Li-Ion Battery Coin Cell for In Situ 3D Visualization of Li Plating

Advanced battery characterization using in situ/operando neutron imaging is critical for uncovering degradation modes such as lithium (Li) plating in Li-ion batteries (LIBs). However, conventional LIBs hinder operando neutron radiography (NR) and in situ neutron micro-computed tomography (N-μCT) for visualizing Li plating near the graphite-separator interface due to strong attenuation from hydrogen-rich components like PP–PE–PP separators, electrolyte, and Fe-based spacers. In this work, we designed and tested a neutron-friendly battery (NFB) optimized for in situ Li detection during extreme fast charging (XFC). Guided by neutron attenuation cross-sections and material transmission, the NFB enables clear visualization at the graphite–separator interface, which is typically opaque in standard LIBs. Electrochemical tests show the NFB exhibits voltage/current responses like standard cells for up to 50 XFC cycles. However, its lower reversibility and capacity are likely due to Cu-coated Al spacer degradation from delamination or corrosion. We propose titanium spacers as a more stable alternative, albeit requiring custom machining. Using this optimized cell, we achieved simultaneous neutron tomography of multiple cells, capturing in situ 3D images of dead Li accumulation, particularly near graphite edges. These heterogeneous deposits and disconnected Li clusters suggest localized current density hotspots during XFC.

25 ENERGY STORAGE↗

Strong Correlation Between Superconductivity and Ferromagnetism in an Fe-Chalcogenide Superconductor

The interplay among topology, superconductivity, and magnetism promises to bring a plethora of exotic and unintuitive behaviors in emergent quantum materials. The family of Fe-chalcogenide superconductors FeTe x Se 1–x are directly relevant in this context due to their intrinsic topological band structure, high-temperature superconductivity, and unconventional pairing symmetry. Despite enormous promise and expectation, the local magnetic properties of FeTe x Se 1–x remain largely unexplored, which prevents a comprehensive understanding of their underlying material properties. Exploiting nitrogen vacancy (NV) centers in diamond, here we report nanoscale quantum sensing and imaging of magnetic flux generated by exfoliated FeTe x Se 1–x flakes, demonstrating strong correlation between superconductivity and ferromagnetism in FeTe x Se 1–x . The coexistence of superconductivity and ferromagnetism in an established topological superconductor opens up new opportunities for exploring exotic spin and charge transport phenomena in quantum materials. The demonstrated coupling between NV centers and FeTe x Se 1–x may also find applications in developing hybrid architectures for next-generation, solid-state-based quantum information technologies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dose-Weighted Radiographic Source-Spot Size

The spatial resolution of a flash radiograph is determined by the time-integrated size of the radiation source. Since the radiation pulse includes the beam head and tail, which may be substantially larger than the beam body, the radiation source is larger than the focused flattop of the electron beam pulse. Moreover, the radiation dose rate is weighted by both beam current and electron energy, and it is the radiation dose that forms the radiograph image. Therefore, in order to estimate radiographic resolution from computer simulations of a focused electron beam, one should use a dose weighted moment analysis of the radiation source distribution. This approach is used to show that, in the absence of beam effects other than space-charge and emittance, radiographic resolution for Scorpius exceeds requirements, regardless of reasonable timing options for current and gap-voltage pulses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The DUNE Far Detector Vertical Drift Technology. Technical Design Report

DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise. In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered. This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.

47 OTHER INSTRUMENTATION↗

Anodic Interfacial Evolution in Extremely Fast Charged Lithium-Ion Batteries

Interfacial reaction mechanisms at the anode/separator interface play a central role in the performance and safety of lithium-ion batteries during fast charging. We report a mechanistic study on the evolution and interactions of the aging mechanisms at the anode/separator interface in lithium cobalt oxide/graphite pouch cells charged with variable charging rates (1–6C) over 10 cycles. In situ electrochemical measurements, including voltage relaxation, Coulombic efficiency, and direct current internal resistance, indicated an incremental lithium loss until the C rates were ≤5C. A substantial capacity fade is observed in the first few cycles of fast charging, but the magnitude of capacity fade progressively diminishes with the number of cycles, indicating a suppression in the lithium deposition mechanism. Post-mortem film thickness, X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM) analyses were performed to elucidate the evolution of electrolyte decomposition, the solid–electrolyte interface (SEI), lithium plating, and film fracture mechanisms with C rate. XPS measurements confirmed an increasing lithium concentration in an SEI film with an increase in the C rate. SEM images showed a growth of dendritic lithium on the anode surface from 1C to 3C. Precrack formation leading to an interfacial film fracture was observed at higher C rates. Furthermore, a differential analysis of the discharge capacity indicated a possible two-phase delithiation from the anode and reduced cathodic lithiation due to lithium loss at high C rates.

36 MATERIALS SCIENCE↗

CaloFlow for CaloChallenge dataset 1

CALOFLOW is a new and promising approach to fast calorimeter simulation based on normalizing flows. Applying CALOFLOW to the photon and charged pion ≥ant showers of Dataset 1 of the Fast Calorimeter Simulation Challenge 2022, we show how it can produce high-fidelity samples with a sampling time that is several orders of magnitude faster than ≥ant. We demonstrate the fidelity of the samples using calorimeter shower images, histograms of high level features, and aggregate metrics such as a classifier trained to distinguish CALOFLOW from ≥ant samples.

Physics↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

Transport characterization and pinning analysis of BaFe 1.9 Ni 0.1 As 2.05 thin films

In this paper, we report on the vortex-glass transition and superconducting performance of BaFe 1.9 Ni 0.1 As 2.05 thin films with T c = 17.8 K on CaF 2 (00 l ) single crystals by pulsed laser deposition. Atomic force microscopy characterization indicates the volumes of droplets appearing on the film surface increase with thickness and Magneto-optical imaging proves slight inhomogeneities in the current flow within the ab -plane of thin film. The thin films show a transport current density J c of ~1.14 MA cm –2 in self-field, and 0.34 and 0.28 MA cm –2 for H // c and H // ab up to 9 T at 4.2 K. Pinning mechanism associated with the fluctuations in the mean free path of the charge carries is found to be dominant in the thin films. The vortex-glass (VG) to vortex-liquid phase transition is identified in terms of the plots of the logarithmic derivative of the resistivity curves under different fields, allowing us to deduce the values of the VG transition temperature T g , and the critical exponent s . The ρ – T curves are well scaled by VG theory. A phase diagram combining the VG transition temperature, irreversibility field and upper critical field is constructed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of Particle Mixing and Gravitational Settling on Charge Transport in Carbon Flow-Electrode Cells

Flowable carbon slurries are actively studied and under development for charge transport in various electrochemical systems including flow capacitors, capacitive deionization cells, semi-solid flow batteries, and lithium extraction. However, much less is known about in operando slurry flow dynamics and their corresponding effect on charge transport. We performed an experimental study of mixing and settling dynamics of slurry electrodes within an electrochemical flow cell during continuous operations. The electrochemical cell consisted of two horizontal co-flowing channels, separated by a cation-exchange membrane (CEM). Here we used high-speed optical imaging of planes parallel to gravity and simultaneous electrochemical measurements. At low flow rates, dense yet dynamic particle beds formed on the bottom electrode in each channel, which unexpectedly yielded the highest currents. This approach enables the operation of the flow cell at low system-average particle concentrations while leveraging gravity-driven particle settling to locally enhance carbon concentrations precisely at the current collector sites. Conversely, high flow rates were characterized by thin particle beds and well-mixed particle flows. In the latter case, the electrodes in closest proximity (located on either side of the CEM) achieved a current higher than the other electrode pairs. The observations have implications for slurry control and electrode designs in electrochemical systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atmospheric pressure plasmas interacting with wet and dry microchannels: reverse surface ionization waves

Atmospheric pressure plasma jets (APPJs) are increasingly being used to functionalize polymers and dielectric materials for biomedical and biotechnology applications. Once such application is microfluidic labs-on-a-chip consisting of dielectric slabs with microchannel grooves hundreds of microns in width and depth. The periodic channels, an example of a complex surface, present challenges in terms of directly and uniformly exposing the surface to the plasma. In this paper, we discuss results from computational and experimental investigations of negative APPJs sustained in Ar/N 2 mixtures flowing into ambient air and incident onto a series of microchannels. Results from two-dimensional plasma hydrodynamics modeling are compared to experimental measurements of electric field and fast-camera imaging. The propagation of the plasma across dry microchannels largely consists of a sequence of surface ionization waves (SIWs) on the top ridges of the channels and bulk ionization waves (IWs) crossing over the channels. The IWs are directed into electric field enhanced vertices of the next ridge. The charging of these ridges produce reverse IWs responsible for the majority of the ionization. The propagation of the plasma across water filled microchannels evolve into hopping SIWs between the leading edges of the water channels, regions of electric enhancement due to polarization of the water. Positive, reverse IWs follow the pre-ionized path of the initial negative waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PHOENIX Electrostatic Design

PHOENIX (Portable, High-efficiency, Optimal ENergy Imaging X-rays) is a quasi-DC, electrostatic, vacuum-diode designed as a portable x-ray source with national defense and commercial applications. The patent-pending PHOENIX concept combines a megavoltage, Cockroft-Walton voltage multiplier with a Van de-Graaff electrostatic charge-storage dome to create a vacuum-diode suitable for x-ray production. Naturally this structure must minimize internal electric fields to reduce electrical breakdown while simultaneously reducing size and weight to enhance portability. In this paper we describe the optimization process and model results obtained using the COMSOL multi-physics code. We describe three models: a prototype model built to demonstrate the PHOENIX concept as part of Laboratory Directed Research and Development (LDRD) Mission Foundation Research (MFR) Phase-I , a “back-of-the-envelope” design used as a starting point for further COMSOL optimization, and finally, the optimized geometry implemented in the MFR Phase-II. In all cases compromises resulting from cost, schedule, and manufacturing constraints were taken into account as the design progressed.

42 ENGINEERING↗

Understanding the chemical contribution to the enhancement mechanism in SERS: Connection with Hammett parameters

The enhancement mechanism due to the molecule-surface chemical interaction in surface-enhanced Raman scattering (SERS) has been characterized using a theoretical approach based on time dependent density functional theory. This includes a systematic study of the chemical mechanism (CM) to the SERS enhancement for halogen substituted benzenethiols interacting with a silver cluster. Changing the halogen on benzenethiol enables us to systematically modulate interactions between the benzenethiol ring and the metal cluster. We observe a decrease in the CM enhancement factor with an increase in atomic number of the halogen for para- substitutions. For meta- substitutions, there is no such trend. However, the results scale linearly with the Hammett parameters for both meta and para halogens, which provides an important predictive tool for interpreting chemical enhancements. We also study the effect of solvation on the CM, showing that there is a systematic increase in enhancement with increasing solvent dielectric constant. As a result, the correlation of CM with other properties, such as the amount of charge transfer between adsorbate and metal, or the excitation energies of charge transfer states, is much less predictive than the Hammett parameter correlation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DNA origami protection and molecular interfacing through engineered sequence-defined peptoids

DNA nanotechnology has established approaches for designing programmable and precisely controlled nanoscale architectures through specific Watson−Crick base-pairing, molecular plasticity, and intermolecular connectivity. In particular, superior control over DNA origami structures could be beneficial for biomedical applications, including biosensing, in vivo imaging, and drug and gene delivery. However, protecting DNA origami structures in complex biological fluids while preserving their structural characteristics remains a major challenge for enabling these applications. Here, we developed a class of structurally well-defined peptoids to protect DNA origamis in ionic and bioactive conditions and systematically explored the effects of peptoid architecture and sequence dependency on DNA origami stability. The applicability of this approach for drug delivery, bioimaging, and cell targeting was also demonstrated. A series of peptoids (PE1–9) with two types of architectures, termed as “brush” and “block,” were built from positively charged monomers and neutral oligo-ethyleneoxy monomers, where certain designs were found to greatly enhance the stability of DNA origami. Through experimental and molecular dynamics studies, we demonstrated the role of sequence-dependent electrostatic interactions of peptoids with the DNA backbone. We showed that octahedral DNA origamis coated with peptoid (PE2) can be used as carriers for anticancer drug and protein, where the peptoid modulated the rate of drug release and prolonged protein stability against proteolytic hydrolysis. Finally, we synthesized two alkyne-modified peptoids (PE8 and PE9), conjugated with fluorophore and antibody, to make stable DNA origamis with imaging and cell-targeting capabilities. Our results demonstrate an approach toward functional and physiologically stable DNA origami for biomedical applications.

36 MATERIALS SCIENCE↗

Visualization of Plasmonic Couplings Using Ultrafast Electron Microscopy

Hybrids of graphene and metal plasmonic nanostructures are promising building blocks for applications in optoelectronics, surface-enhanced scattering, biosensing, and quantum information. An understanding of the coupling mechanism in these hybrid systems is of vital importance to its applications. Previous efforts in this field mainly focused on spectroscopic studies of strong coupling within the hybrids with no spatial resolution. In this study, we report direct imaging of the local plasmonic coupling between single Au nanocapsules and graphene step edges at the nanometer scale by photon-induced near-field electron microscopy in an ultrafast electron microscope for the first time. The proximity of a step in the graphene to the nanocapsule causes asymmetric surface charge density at the ends of the nanocapsules. Computational electromagnetic simulations confirm the experimental observations. The results reported here indicate that this hybrid system could be used to manipulate the localized electromagnetic field on the nanoscale, enabling promising future plasmonic devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Unraveling the Unconventional Order of a High-Mobility Indacenodithiophene-Benzothiadiazole Copolymer

We report a new class of donor–acceptor (D-A) copolymers found to produce high charge carrier mobilities competitive with amorphous silicon (>1 cm 2 V –1 s –1 ) exhibit the puzzling microstructure of substantial local order, however lacking long-range order and crystallinity previously deemed necessary for achieving high mobility. Here, we demonstrate the application of low-dose transmission electron microscopy to image and quantify the nanoscale and mesoscale organization of an archetypal D-A copolymer across areas comparable to electronic devices (≈9 μm 2 ). The local structure is spatially resolved by mapping the backbone (001) spacing reflection, revealing nanocrystallites of aligned polymer chains throughout nearly the entire film. Analysis of the nanoscale structure of its ordered domains suggests significant short- and medium-range order and preferential grain boundary orientations. Moreover, we provide insights into the rich, interconnected mesoscale organization of this new family of D-A copolymers by analysis of the local orientational spatial autocorrelations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Skipper-CCD sensors for the Oscura experiment: requirements and preliminary tests

Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2–10 electron ionization-signal region for the full 30 kg-year exposure, with a radiation background rate of 0.01 dru.[1 dru (differential rate unit) corresponds to 1 event/kg/day/keV.] In order to achieve this goal, Oscura must address each potential source of background events, including instrumental backgrounds. In this work, we discuss the main instrumental background sources and the strategy to control them, establishing a set of constraints on the sensors' performance parameters. We present results from the tests of the first fabricated Oscura prototype sensors, evaluate their performance in the context of the established constraints and estimate the Oscura instrumental background based on these results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗