Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human performance measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Promoting Crew Autonomy in a Human Spaceflight Earth Analog Mission through Self-Scheduling

Deep space exploration missions face the challenge of communication transmission latencies between ground stations and astronaut crews due to increasing distance between the Earth and spacecraft in transit. To address this, research at NASA has aimed toward supporting crew autonomy by enabling astronauts to schedule their own timelines with minimal oversight from Mission Control. While self-scheduling has been shown to be feasible, it is yet to be studied as an integral part of autonomous crew operations. The current paper reviews the operationalization of self-scheduling and a number of related objectives during Campaign 6 of HERA, a Human Exploration Research Analog. Research objectives include studying the effects of phasic autonomy over the course of a 45-day mission, evaluating differences in scheduling performance produced by software interface aids, and deploying a novel measure of crew attitudes toward self-scheduling and plan execution.

crew autonomy↗

Promoting Crew Autonomy in a Human Spaceflight Earth Analog Mission through Self-Scheduling

Deep space exploration missions face the challenge of communication transmission latencies between ground stations and astronaut crews due to increasing distance between the Earth and spacecraft in transit. To address this, research at NASA has aimed toward supporting crew autonomy by enabling astronauts to schedule their own timelines with minimal oversight from Mission Control. While self-scheduling has been shown to be feasible, it is yet to be studied as an integral part of autonomous crew operations. The current paper reviews the operationalization of self-scheduling and a number of related objectives during Campaign 6 of HERA, a Human Exploration Research Analog. Research objectives include studying the effects of phasic autonomy over the course of a 45-day mission, evaluating differences in scheduling performance produced by software interface aids, and deploying a novel measure of crew attitudes toward self-scheduling and plan execution.

crew autonomy↗

Eye-tracking of nodule detection in lung CT volumetric data

Purpose: Signal detection on 3D medical images depends on many factors, such as foveal and peripheral vision, the type of signal, and background complexity, and the speed at which the frames are displayed. In this paper, the authors focus on the speed with which radiologists and naïve observers search through medical images. Prior to the study, the authors asked the radiologists to estimate the speed at which they scrolled through CT sets. They gave a subjective estimate of 5 frames per second (fps). The aim of this paper is to measure and analyze the speed with which humans scroll through image stacks, showing a method to visually display the behavior of observers as the search is made as well as measuring the accuracy of the decisions. This information will be useful in the development of model observers, mathematical algorithms that can be used to evaluate diagnostic imaging systems. Methods: The authors performed a series of 3D 4-alternative forced-choice lung nodule detection tasks on volumetric stacks of chest CT images iteratively reconstructed in lung algorithm. The strategy used by three radiologists and three naïve observers was assessed using an eye-tracker in order to establish where their gaze was fixed during the experiment and to verify that when a decision was made, a correct answer was not due only to chance. In a first set of experiments, the observers were restricted to read the images at three fixed speeds of image scrolling and were allowed to see each alternative once. In the second set of experiments, the subjects were allowed to scroll through the image stacks at will with no time or gaze limits. In both static-speed and free-scrolling conditions, the four image stacks were displayed simultaneously. All trials were shown at two different image contrasts. Results: The authors were able to determine a histogram of scrolling speeds in frames per second. The scrolling speed of the naïve observers and the radiologists at the moment the signal was detected was measured at 25–30 fps. For the task chosen, the performance of the observers was not affected by the contrast or experience of the observer. However, the naïve observers exhibited a different pattern of scrolling than the radiologists, which included a tendency toward higher number of direction changes and number of slices viewed. Conclusions: The authors have determined a distribution of speeds for volumetric detection tasks. The speed at detection was higher than that subjectively estimated by the radiologists before the experiment. The speed information that was measured will be useful in the development of 3D model observers, especially anthropomorphic model observers which try to mimic human behavior.

60 APPLIED LIFE SCIENCES↗

Characterization of a novel EPID designed for simultaneous imaging and dose verification in radiotherapy

Purpose: Standard amorphous silicon electronic portal imaging devices (a-Si EPIDs) are x-ray imagers used frequently in radiotherapy that indirectly detect incident x-rays using a metal plate and phosphor screen. These detectors may also be used as two-dimensional dosimeters; however, they have a well-characterized nonwater-equivalent dosimetric response. Plastic scintillating (PS) fibers, on the other hand, have been shown to respond in a water-equivalent manner to x-rays in the energy range typically encountered during radiotherapy. In this study, the authors report on the first experimental measurements taken with a novel prototype PS a-Si EPID developed for the purpose of performing simultaneous imaging and dosimetry in radiotherapy. This prototype employs an array of PS fibers in place of the standard metal plate and phosphor screen. The imaging performance and dosimetric response of the prototype EPID were evaluated experimentally and compared to that of the standard EPID.Methods: Clinical 6 MV photon beams were used to first measure the detector sensitivity, linearity of dose response, and pixel noise characteristics of the prototype and standard EPIDs. Second, the dosimetric response of each EPID was evaluated relative to a reference water-equivalent dosimeter by measuring the off-axis and field size response in a nontransit configuration, along with the off-axis, field size, and transmission response in a transit configuration using solid water blocks. Finally, the imaging performance of the prototype and standard EPIDs was evaluated quantitatively by using an image quality phantom to measure the contrast to noise ratio (CNR) and spatial resolution of images acquired with each detector, and qualitatively by using an anthropomorphic phantom to acquire images representative of human anatomy.Results: The prototype EPID's sensitivity was 0.37 times that of the standard EPID. Both EPIDs exhibited responses that were linear with delivered dose over a range of 1–100 monitor units. Over this range, the prototype and standard EPID central axis responses agreed to within 1.6%. Images taken with the prototype EPID were noisier than those taken with the standard EPID, with fractional uncertainties of 0.2% and 0.05% within the central 1 cm{sup 2}, respectively. For all dosimetry measurements, the prototype EPID exhibited a near water-equivalent response whereas the standard EPID did not. The CNR and spatial resolution of images taken with the standard EPID were greater than those taken with the prototype EPID.Conclusions: A prototype EPID employing an array of PS fibers has been developed and the first experimental measurements are reported. The prototype EPID demonstrated a much morewater-equivalent dose response than the standard EPID. While the imaging performance of the standard EPID was superior to that of the prototype, the prototype EPID has many design characteristics that may be optimized to improve imaging performance. This investigation demonstrates the feasibility of a new detector design for simultaneous imaging and dosimetry treatment verification in radiotherapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Mobile Motion Analysis System Using Intertial Sensors for Analysis of Lower Limb Prosthetics

Soldiers returning from the global war on terror requiring lower leg prosthetics generally have different concerns and requirements than the typical lower leg amputee. These subjects are usually young, wish to remain active and often desire to return to active military duty. As such, they demand higher performance from their prosthetics, but are at risk for chronic injury and joint conditions in their unaffected limb. Motion analysis is a valuable tool in assessing the performance of new and existing prosthetic technologies as well as the methods in fitting these devices to both maximize performance and minimize risk of injury for the individual soldier. We are developing a mobile, low-cost motion analysis system using inertial measurement units (IMUs) and two custom force sensors that detect ground reaction forces and moments on both the unaffected limb and prosthesis. IMUs were tested on a robot programmed to simulate human gait motion. An algorithm which uses a kinematic model of the robot and an extended Kalman filter (EKF) was used to convert the rates and accelerations from the gyro and accelerometer into joint angles. Compared to encoder data from the robot, which was considered the ground truth in this experiment, the inertial measurement system had a RMSE of <1.0 degree. Collecting kinematic and kinetic data without the restrictions and expense of a motion analysis lab could help researchers, designers and prosthetists advance prosthesis technology and customize devices for individuals. Ultimately, these improvements will result in better prosthetic performance for the military population.

Mueller, John Kyle P↗

Measurement of human pilot dynamic characteristics in flight simulation

Fast Fourier Transform (FFT) and Least Square Error (LSE) estimation techniques were applied to the problem of identifying pilot-vehicle dynamic characteristics in flight simulation. A brief investigation of the effects of noise, input bandwidth and system delay upon the FFT and LSE techniques was undertaken using synthetic data. Data from a piloted simulation conducted at NASA Ames Research Center was then analyzed. The simulation was performed in the NASA Ames Research Center Variable Stability CH-47B helicopter operating in fixed-basis simulator mode. The piloting task consisted of maintaining the simulated vehicle over a moving hover pad whose motion was described by a random-appearing sum of sinusoids. The two test subjects used a head-down, color cathode ray tube (CRT) display for guidance and control information. Test configurations differed in the number of axes being controlled by the pilot (longitudinal only versus longitudinal and lateral), and in the presence or absence of an important display indicator called an 'acceleration ball'. A number of different pilot-vehicle transfer functions were measured, and where appropriate, qualitatively compared with theoretical pilot- vehicle models. Some indirect evidence suggesting pursuit behavior on the part of the test subjects is discussed.

Reedy, James T.↗

Mars Atmosphere Resource Verification INsitu (MARVIN) - In Situ Resource Demonstration for the Mars 2020 Mission

The making of oxygen from resources in the Martian atmosphere, known as In Situ Resource Utilization (ISRU), has the potential to provide substantial benefits for future robotic and human exploration. In particular, the ability to produce oxygen on Mars for use in propulsion, life support, and power systems can provide significant mission benefits such as a reducing launch mass, lander size, and mission and crew risk. To advance ISRU for possible incorporation into future human missions to Mars, NASA proposed including an ISRU instrument on the Mars 2020 rover mission, through an announcement of opportunity (AO). The purpose of the the Mars Atmosphere Resource Verification INsitu or (MARVIN) instrument is to provide the first demonstration on Mars of oxygen production from acquired and stored Martian atmospheric carbon dioxide, as well as take measurements of atmospheric pressure and temperature, and of suspended dust particle sizes and amounts entrained in collected atmosphere gases at different times of the Mars day and year. The hardware performance and environmental data obtained will be critical for future ISRU systems that will reduce the mass of propellants and other consumables launched from Earth for robotic and human exploration, for better understanding of Mars dust and mitigation techniques to improve crew safety, and to help further define Mars global circulation models and better understand the regional atmospheric dynamics on Mars. The technologies selected for MARVIN are also scalable for future robotic sample return and human missions to Mars using ISRU.

Sanders, Gerald B.↗

Methodology, Methods, and Metrics for Testing and Evaluating Augmented Cognition Systems

The augmented cognition research community seeks cognitive neuroscience-based solutions to improve warfighter performance by applying and managing mitigation strategies to reduce workload and improve the throughput and quality of decisions. The focus of augmented cognition mitigation research is to define, demonstrate, and exploit neuroscience and behavioral measures that support inferences about the warfighter’s cognitive state that prescribe the nature and timing of mitigation. A research challenge is to develop valid evaluation methodologies, metrics and measures to assess the impact of augmented cognition mitigations. Two considerations are external validity, which is the extent to which the results apply to operational contexts; and internal validity, which reflects the reliability of performance measures and the conclusions based on analysis of results. The scientific rigor of the research methodology employed in conducting empirical investigations largely affects the validity of the findings. External validity requirements also compel us to demonstrate operational significance of mitigations. Thus it is important to demonstrate effectiveness of mitigations under specific conditions. This chapter reviews some cognitive science and methodological considerations in designing augmented cognition research studies and associated human performance metrics and analysis methods to assess the impact of augmented cognition mitigations.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Measurements of intermediate-frequency electric and magnetic fields in households

Historically, assessment of human exposure to electric and magnetic fields has focused on the extremely-low-frequency (ELF) and radiofrequency (RF) ranges. However, research on the typically emitted fields in the intermediate-frequency (IF) range (300 Hz to 1 MHz) as well as potential effects of IF fields on the human body remains limited, although the range of household appliances with electrical components working in the IF range has grown significantly (e.g., induction cookers and compact fluorescent lighting). In this study, an extensive measurement survey was performed on the levels of electric and magnetic fields in the IF range typically present in residences as well as emitted by a wide range of household appliances under real-life circumstances. Using spot measurements, residential IF field levels were found to be generally low, while the use of certain appliances at close distance (20 cm) may result in a relatively high exposure. Overall, appliance emissions contained either harmonic signals, with fundamental frequencies between 6 kHz and 300 kHz, which were sometimes accompanied by regions in the IF spectrum of rather noisy, elevated field strengths, or much more capricious spectra, dominated by 50 Hz harmonics emanating far in the IF domain. The maximum peak field strengths recorded at 20 cm were 41.5 V/m and 2.7 A/m, both from induction cookers. Finally, none of the appliance emissions in the IF range exceeded the exposure summation rules recommended by the International Commission on Non-Ionizing Radiation Protection guidelines and the International Electrotechnical Commission (IEC 62233) standard at 20 cm and beyond (maximum exposure quotients EQ{sub E} 1.0 and {sub E}Q{sub H} 0.13). - Highlights: • Survey of residential electric and magnetic fields at intermediate frequencies (IF). • IF-EF and -MF emitted by 280 household appliances were characterised. • Strongest emitters were induction cookers, CFLs, LCD-TVs, and microwave ovens. • No emissions exceeded ICNIRP limits (highest exposure quotient was 1.00).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predicting human developmental toxicity of pharmaceuticals using human embryonic stem cells and metabolomics

Teratogens, substances that may cause fetal abnormalities during development, are responsible for a significant number of birth defects. Animal models used to predict teratogenicity often do not faithfully correlate to human response. Here, we seek to develop a more predictive developmental toxicity model based on an in vitro method that utilizes both human embryonic stem (hES) cells and metabolomics to discover biomarkers of developmental toxicity. We developed a method where hES cells were dosed with several drugs of known teratogenicity then LC-MS analysis was performed to measure changes in abundance levels of small molecules in response to drug dosing. Statistical analysis was employed to select for specific mass features that can provide a prediction of the developmental toxicity of a substance. These molecules can serve as biomarkers of developmental toxicity, leading to better prediction of teratogenicity. In particular, our work shows a correlation between teratogenicity and changes of greater than 10% in the ratio of arginine to asymmetric dimethylarginine levels. In addition, this study resulted in the establishment of a predictive model based on the most informative mass features. This model was subsequently tested for its predictive accuracy in two blinded studies using eight drugs of known teratogenicity, where it correctly predicted the teratogenicity for seven of the eight drugs. Thus, our initial data shows that this platform is a robust alternative to animal and other in vitro models for the prediction of the developmental toxicity of chemicals that may also provide invaluable information about the underlying biochemical pathways.

60 APPLIED LIFE SCIENCES↗

Optical properties of human colon tissues in the 350 – 2500 nm spectral range

We present the optical characteristics of the mucosa and submucosa of human colon tissue. The experiments are performed in vitro using a LAMBDA 950 spectrophotometer in the 350 – 2500 nm spectral range. The absorption and scattering coefficients and the scattering anisotropy factor are calculated based on the measured diffuse reflectance and total and collimated transmittance spectra using the inverse Monte Carlo method. (laser biophotonics)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Biochemical assays on plasminogen activators and hormones from kidney sources

Investigations were established for the purpose of analyzing the conditioned media from human embryonic kidney cell subpopulations separated in space by electrophoresis. This data is based on the experiments performed on STS-8 on the continuous flow electrophoresis system. The primary biological activity that was analyzed was plasminogen activator activity, but some assays for erythropoeitin and human granulocyte colony stimulating activity were also performed. It is concluded that a battery of assays are required to completely define the plasminogen activator profile of a conditioned media from cell culture. Each type of assay measures different parts of the mixture and are influenced by different parameters. The functional role of each assay is given along with an indication of which combination of assays are required to answer specific questions. With this type of information it is possible by combinations of assays with mathematical analysis to pinpoint a specific component of the system.

Barlow, Grant H.↗

Fibre Size and Capillary Supply in Human M.vastus Lateralis after Long-Duration Spaceflight: Effects of Countermeasure Exercise Training

Muscle fiber atrophy is shown to be induced in human m.vastus lateralis even during short duration spaceflight. A study carried out to evaluate the effects of long duration spaceflight on human skeletal muscle fiber characteristics is reported on. Muscle fiber size and capillary supply were measured in samples obtained from the m.vastus lateralis of astronauts before and after a long duration flight. Most of the astronauts performed more than 80 percent of the recommended exercise training loads in terms of volume and intensity. Very slight fiber changes were found in fiber size and muscle capillary supply indices. It is concluded that the main factor which maintained fiber characteristics in the astronauts was the exercise measures taken by them.

Shenkman, Boris S.↗

Using Videos Derived from Simulations to Support the Analysis of Spatial Awareness in Synthetic Vision Displays

The evaluation of human-centered systems can be performed using a variety of different methodologies. This paper describes a human-centered systems evaluation methodology where participants watch 5-second non-interactive videos of a system in operation before supplying judgments and subjective measures based on the information conveyed in the videos. This methodology was used to evaluate the ability of different textures and fields of view to convey spatial awareness in synthetic vision systems (SVS) displays. It produced significant results for both judgment based and subjective measures. This method is compared to other methods commonly used to evaluate SVS displays based on cost, the amount of experimental time required, experimental flexibility, and the type of data provided.

Boton, Matthew L.↗

Custom Integration of Multiple Medical Functionalities

INTRODUCTION: Previous spaceflight experience and results from probabilistic risk assessment of spaceflight medical risk have highlighted the need for vital sign measurements, medical scopes, and clinical imaging tools for managing medical conditions during spaceflight. The Human Research Program’s Exploration Medical Capability (ExMC) Element and the Mars Campaign Office’s Exploration Medical Integrated Product Team (XMIPT) have performed ground-based evaluations of two Commercial-off-the-Shelf (COTS) Multi-functional Integrated Medical (MIM) devices, which integrate various medical capabilities together in one device. The key findings from these evaluations are presented in a complementary presentation, leaving this presentation to focus on forward recommendations for customized integration of multiple medical functionalities. KEY COMPONENTS: The key features of a custom integration of multiple medical functionalities includes devices and capabilities that optimally reduce medical risk. The COTS MIM devices incorporated functionality for best supporting Earth-based, emergency, pre-hospital care. Our custom integration will use probabilistic risk assessment tools, such as the Medical Extensible Dynamic Probabilistic Risk Assessment Tool (MEDPRAT), to determine the optimal functionality to include based on medical risk minimization. An additional feature of custom integration includes the ability to adapt to different requirements within different vehicles and/or missions. The COTS MIM devices store data in patient specific records, however, the format of the records is not modifiable, and data are not easily transferred from the MIM device to a central data architecture outside of the manufacturer’s established system. Our concept for custom integration will use devices that have an open application programming interface, which can easily connect to independent data architectures and third-party visualization software. The ultrasound capabilities included within the COTS MIM devices did not satisfy many of the Artemis Research and Operations Working Group’s ultrasound functional needs, and therefore, incorporation of higher quality ultrasound capabilities within a customized integration will be beneficial. The COTS MIM devices included minimal procedural guidance and clinical decision support tools. Supplemental tools of this type would need to be supplied along with the COTS MIM devices if they were to be used operationally, so another advantage of customization is the ability to integrate these support tools along with the medical functionality, for a more streamlined user experience. CONCLUSION: Investigation of a customized integration of medical functionality provides a method for further understanding the needs of a long-term exploration spaceflight medical system. The crew members of these exploration missions will need to operate more and more independently from Earth-based ground support. Therefore, having an optimized, streamlined medical system, which contains the functionality and supporting information needed, while remaining within mission and vehicle constraints, will help to maintain crew health and performance, which is necessary for achieving high levels of mission success.

B E Lewandowski↗

Distinct Pattern of Oculomotor Impairment Associated with Acute Sleep Loss and Circadian Misalignment

Sleep loss and circadianmisalignment have long been known to impair human cognitive and motor performance with significant societal and health consequences. It is well known that human reaction time to a visual cue is impaired following sleep loss and circadian misalignment, but it has remained unclear how more complex visuomotor control behaviour is altered under these conditions. In this study, we measured 14 parameters of the voluntary ocular tracking response of 12 human participants (six females) to systematically examine the effects of sleep loss and circadianmisalignment using a constant routine 24 h acute sleep-deprivation paradigm. The combination of state-of-the-art oculometric and sleep-research methodologies allowed us to document, for the first time, large changes in many components of pursuit, saccades and visual motion processing as a function of time awake and circadian phase. Further, we observed a pattern of impairment across our set of oculometric measures that is qualitatively different from that observed previously with other mild neural impairments. We conclude that dynamic vision and visuomotor control exhibit a distinct pattern of impairment linked with time awake and circadian phase. Therefore, a sufficiently broad set of oculometric measures could provide a sensitive and specific behavioural biomarker of acute sleep loss and circadian misalignment. We foresee potential applications of such oculometric biomarkers assisting in the assessment of readiness-to-perform higher risk tasks and in the characterization of sub-clinical neural impairment in the face of a multiplicity of potential risk factors, including disrupted sleep and circadian rhythms.

Stone, Leland S.↗

Prediction and analysis of human performance in a VTOL hover task

An optimal control model is used to predict pilot performance in a series of longitudinal hovering tasks. Configurational changes are considered that alter significantly the system response to both control and disturbance inputs. Model predictions of mean-squared performance are compared with measurements obtained in an independent experimental study of the task. In addition, the optimal control model is used to predict describing functions that correspond to the loop closing pilot transfer functions frequently employed in classical multiloop manual control analyses.

Baron, S.↗