Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Fueling method for small, steady-state, aneutronic FRC fusion reactors

A system and method for fueling a fusion reactor. The system includes a reactor chamber containing a stable plasma including a fusion fuel; a heating system configured to heat the plasma and increase an ion energy of the plasma to a level sufficient for producing net power from fusion reactions in the stable plasma; a plurality of magnets coaxial to the reactor chamber, the plurality of magnets producing a magnetic field sufficient to confine the stable plasma and promote rapid loss of fusion products into a scrape off layer; and a neutral beam injection system configured to inject additional quantities of the fusion fuel to sustain the power output of the fusion reaction.

Cohen, Samuel A.↗

Coupling Subsurface and Above-Surface Models for Optimizing the Design of Borefields and District Heating and Cooling Systems

Accurate dynamic energy simulation is important for the design and sizing of district heating and cooling systems with geothermal heat exchange for seasonal energy storage. Current modeling approaches in building and district energy simulation tools typically consider heat conduction through the ground between boreholes without flowing groundwater. While detailed simulation tools for subsurface heat and mass transfer exist, these fall short in simulating above-surface energy systems. To support the design and operation of such systems, the study developed a coupled model including a software package for building and district energy simulation, and software for detailed heat and mass transfer in the subsurface. For the first, it uses the open-source Modelica Buildings Library, which includes dynamic simulation models for building and district energy and control systems. For the heat and mass transfer in the soil, it uses the TOUGH simulator. The TOUGH family of codes can model heat and multi-phase, multi-component mass transport for a variety of fluid systems, as well as chemical reactions, in fractured porous media. The study validated the coupled modeling approach by comparing the simulation results with one from the g-function based ground response model. It then looked into effects when the water table and the regional groundwater flow are considered in the ground, from the perspective of heat exchange between borehole and ground, and the electrical consumption of the district heating and cooling systems. To access the simulation models, please find the links in the submission: -- For coupled approach validation: see model Buildings.Fluid.Geothermal.Borefields.Examples.BorefieldsWithTough and Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from the "Modelica Building Library" resource, branch issue1495_tough_interface, commit a2667c0. -- For the study of the effect of water table: see model Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from he "Modelica Building Library" resource, branch issue1495_tough_interface_moreIO, commit 760de49. -- For the study of the effect of regional groundwater flow: see Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from he "Modelica Building Library" resource, branch issue1495_tough_interface_moreIO_3D, commit c2a2d2a. The coupling interface script "GrounResponse.py" can be found from the above links in the folder Buildings/Resources/Python-Sources. Also, the needed files for TOUGH simulation are in the folder Buildings/Resources/Python-Sources/ToughFiles that can be accessed through the above links. A brief description of these files is given below; detailed specifications for the first three files may be found in the TOUGH3 Users Guide (Jung et al., 2018) https://tough.lbl.gov/documentation/tough-manuals/. (1) INCON - initial conditions for each grid block (2) INFILE - main input file with material properties and control parameters (3) MESH - description of the computational grid (4) readsave - Modelica/TOUGH interface program: read the final output of TOUGH simulation after TOUGH time step and prepare for transfer to Modelica for next Modelica time step (5) readsave.inp - input parameters for program readsave (6) writeincon - Modelica/TOUGH interface program: write the output of Modelica after Modelica time step and prepare for transfer to TOUGH as initial conditions for the next TOUGH step (7) writeincon.inp - input parameters for program writeincon

15 GEOTHERMAL ENERGY↗

Strategies to Mitigate Ammonia Release on the International Space Station

International Space Station (ISS) is crucial to its continuous operation. Off-nominal situations can arise from virtually any aspect of ISS operations. One situation of particular concern is the inadvertent release of a chemical into the ISS atmosphere. In sufficient quantities, a chemical release can render the ISS uninhabitable regardless of the chemical s toxicity as a result of its effect on the hardware used to maintain the environment. This is certainly true with system chemicals which are integral components to the function and purpose of the system. Safeguards, such as design for minimum risk, multiple containment, hazard assessments, rigorous safety reviews, and others, are in place to minimize the probability of a chemical release to the ISS environment thereby allowing the benefits of system chemicals to outweigh the risks associated with them. The thermal control system is an example of such a system. Heat generated within the ISS is transferred from the internal thermal control system (ITCS) to the external thermal control system (ETCS) via two, single-barrier interface heat exchangers (IFHX). The ITCS and ETCS are closed-loop systems which utilize water and anhydrous ammonia, respectively, as heat-transfer fluids. There is approximately 1200 lbs. (208 gallons) of anhydrous ammonia in the ETCS circulating through the two heat exchangers, transferring heat from the ITCS water lines. At the amounts present in the ETCS, anhydrous ammonia is one system chemical that can easily overwhelm the station atmosphere scrubbing capabilities and render the ISS uninhabitable in the event of a catastrophic rupture. Although safeguards have certainly minimized the risk of an ammonia release into the Station atmosphere, credible release scenarios and controls to manage these scenarios are examined.

Macatangay, Ariel V.↗

Solar residential heating and cooling system development test program

A solar heating and cooling system is described, which was installed in a simulated home at Marshall Space Flight Center. Performance data are provided for the checkout and initial operational phase for key subsystems and for the total system. Valuable information was obtained with regard to operation of a solar cooling system during the first summer of operation. Areas where improvements and modifications are required to optimize such a system are discussed.

Humphries, W. R.↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Tool Development and Validation for Solar Industry Process Heat Using Particle Thermal Energy Storage

U.S. industry sectors used 26.2 quadrillion Btu and accounted for 33% of total energy consumption in 2021 according to the Energy Information Agency. Industrial process heat accounts for 70% of industrial energy use with application temperatures ranging from 60 degrees -1100 degrees C. Industry processes, heavily relying on fossil fuels of cheap coal or natural gas, differ widely in operating conditions and load requirements which makes them difficult to standardize and imposes great challenges in decarbonization. Industry processes require reliable energy supply and vary widely in temperature ranges. Storing energy from renewable sources is necessary to improve reliability and to mitigate renewable intermittency when replacing carbon fuel-based heat supplies to achieve energy savings and reduce emissions. To this end, we have developed a particle-based thermal energy storage (TES) technology using low-cost and highly stable silica sand as a storage medium. The economic and performance-based analysis is key for renewable energy sources to reliably supply industry process heat and ultimately displace fossil fuels for decarbonization. The diversified industrial processes need case-by-case analysis and design. Therefore, an adaptive modeling tool is key for renewable power with energy storage to meet industry demands. Thus, a modeling tool to simulate a solar industry process heat system using the particle TES has been developed using the object-oriented equation-based language Modelica and the commercial platform of Modelon Impact. The Modelica-based software tool provides a general simulation environment for the design of reliable solar energy sources integrated with TES for various industrial process applications at different temperatures for economic competence with fossil fuels such as coal and natural gases. It uses both customized and standard component modeling modules in Modelon libraries for the flexibility to be adapted to a specific energy demand application. The particle TES system establishes a uniform energy supply platform with an efficient heat exchanger and particle thermal energy reservoir integrated with renewable powers. The particle TES system can provide a wide temperature range and can have a large storage temperature difference that increases storage energy density; therefore, it can be an adaptable energy storage system integrated with renewable power to supply 24/7 heat for industry decarbonization.

concentrated solar thermal↗

Performance evaluation of the Solar Building Test Facility

The general performance of the NASA Solar Building Test Facility (SBTF) and its subsystems and components over a four year operational period is discussed, and data are provided for a typical one year period. The facility consists of a 4645 sq office building modified to accept solar heated water for operation of an absorption air conditioner and a baseboard heating system. An adjoining 1176 sq solar flat plate collector field with a 114 cu tank provides the solar heated water. The solar system provided 57 percent of the energy required for heating and cooling on an annual basis. The average efficiency of the solar collectors was 26 percent over a one year period.

Jensen, R. N.↗

Solar heating and hot water system installed at Municipal Building complex, Abbeville, South Carolina

Information on the solar energy system installed at the new municipal building for the City of Abbeville, SC is presented, including a description of solar energy system and buildings, lessons learned, and recommendations. The solar space heating system is a direct air heating system. The flat roof collector panel was sized to provide 75% of the heating requirement based on an average day in January. The collectors used are job-built with two layers of filon corrugated fiberglass FRP panels cross lapped make up the cover. The storage consists of a pit filled with washed 3/4 in - 1 1/2 in diameter crushed granite stone. The air handler includes the air handling mechanism, motorized dampers, air circulating blower, sensors, control relays and mode control unit. Solar heating of water is provided only those times when the hot air in the collector is exhausted to the outside.

Source record↗

In situ observation of irradiation-induced enhancement to the desorption pressure of zirconium hydride in a nuclear reactor

We quantify the effect of a nuclear-reactor environment on the hydrogen isotope equilibrium vapor pressure over pure zirconium and zirconium hydride. A vacuum-sealed capsule containing a zirconium foil with 6 atom% deuterium was irradiated at a neutron flux of ~10 14 cm -2 s -1 at the University of Missouri Research Reactor (MURR). The internal stainless-steel (SS) sample holder acted as the heat source via gamma absorption. To measure low desorption pressures in a high-flux environment, we developed a method to transduce pressure from the measured sample temperature during irradiation, calibrating with known deuterium pressures in unirradiated capsules at various heating powers using an internal filament-heated system designed to mimic irradiation-induced heating. Our temperature-pressure transduction method operates similarly to a Pirani or thermocouple pressure gauge. The in-reactor measurements revealed a roughly 4-fold enhancement in desorption pressure after only 6 h of irradiation (~2 × 10 18 cm -2 neutron fluence) compared to thermal desorption in control experiments, indicating a nonthermal contribution from neutron irradiation. The slower temperature/pressure stabilization rate in the reactor suggests that desorption pressure enhancement increases with neutron fluence. Further, this enhancement signifies increased solubility of hydrogen isotopes in zirconium during irradiation. We propose that high-energy neutron collisions with hydrogen isotopes in hydrides lead to their decomposition at lower temperatures, supersaturating the surrounding αZr lattice and resulting in higher desorption pressure, which continues to rise as more hydrides dissolve with increasing neutron fluence.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Self-regenerating desiccant system

Compact system uses inherent diurnal cyclic airflow in system and energy of sun as drying heat. System requires no power for operation, has no moving parts to wear out, requires no blowers or manifolds, and is relatively inexpensive to produce.

Anthony, K. G.↗

Solar heating and cooling system design and development

The development of eight prototype solar heating and combined heating and cooling systems is reported. Manufacture, test, installation, maintenance, problem resolution, and monitoring the operation of prototype systems is included. Heating and cooling equipment for single family residential and commercial applications and eight operational test sites (four heating and four heating and cooling) is described.

Source record↗

Thermal Technology Development Activities at the Goddard Space Flight Center - 2001

This presentation provides an overview of thermal technology development activities carried out at NASA's Goddard Space Flight Center during 2001. Specific topics covered include: two-phase systems (heat pipes, capillary pumped loops, vapor compression systems and phase change materials), variable emittance systems, advanced coatings, high conductivity materials and electrohydrodynamic (EHD) thermal coatings. The application of these activities to specific space missions is also discussed.

Butler, Dan↗

Performances of the Heat Melt Compactor System in Various Operational Scenarios

The Heat Melt Compactor (HMC) system has been developed to manage the waste generated on board spacecraft during long-duration missions. The quantity and composition of spacecraft trash depends upon the mission and can have a very high daily variability. This requires a flexible system able to manage extreme waste scenarios. Most missions will generate on average about one kilograms of trash per astronaut per day, derived mainly from the spacecraft logistics supplies and consisting of clothing, food & beverage residues, packaging, paper, plastic, hygiene wipes, and many other personal or scientific items used and discarded by the crew. Uncontained and unprocessed waste is a health hazard and a habitat storage problem. However, trash also contains valuable resources such as water. HMC is designed to provide volume reduction, microbial safening and stabilization, water recovery, and radiation shielding material. The final byproduct generated by HMC is a sterilized tile with the consistency of hard plastic that can be safely handled, easily stored, and used for radiation protection. This paper provides the summary of an extensive campaign of testing performed using the HMC system to simulate different nominal and extreme operational scenarios and to generate the data necessary to finalize requirements for proto-flight hardware to be deployed to an International Space Station (ISS) EXPRESS Rack.

HMC↗

Solar energy control system

A solar energy control system for a hot air type solar energy heating system wherein thermocouples are arranged to sense the temperature of a solar collector, a space to be heated, and a top and bottom of a heat storage unit is disclosed. Pertinent thermocouples are differentially connected together, and these are employed to effect the operation of dampers, a fan, and an auxiliary heat source. In accomplishing this, the differential outputs from the thermocouples are amplified by a single amplifier by multiplexing techniques. Additionally, the amplifier is corrected as to offset by including as one multiplex channel a common reference signal.

Currie, J. R.↗

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar-Heated Health Education Center -- North Carolina

Solar heating system described in 55-page report uses 171 collectors, roof-mounted in two arrays. System is designed to supply about 45 percent of heat needs of building with minimal effects on existing structure, mechanical systems, and appearance.

Source record↗

Solar-Heated Office Building -- Dallas, Texas

Solar heating system designed to supply 87 percent of space heating and 100 percent of potable hot-water needs of large office building in Dallas, Texas. Unique feature of array serves as roofing over office lobby and gives building attractive triangular appearance. Report includes basic system drawings, test data, operating procedures, and maintenance instructions.

Source record↗