Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heart rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Certain cardiovascular indices predict syncope in the postural tachycardia syndrome

Patients with postural tachycardia syndrome (POTS) represent a patient population with orthostatic intolerance; some are prone to syncope, others are not. The underlying neurocardiovascular mechanisms are not completely understood. The current study was undertaken to assess if certain cardiovascular indices are predictive of syncope in POTS. We compared the response to tilt-up and the Valsalva maneuver in four groups: POTS patients who fainted (POTS-f; n = 11;31 +/- 11 years): POTS patients who did not faint (POTS-nf; n = 9; 29 +/- 9 years); normal controls (NLS; n = 13; 39 +/- 11 years); patients with generalized autonomic failure with orthostatic hypotension and syncope (n = 10; 59 +/- 14 years). Beat-to-beat heart rate (HR), systolic arterial pressure, diastolic arterial pressure (DAP) and pulse pressure (PP) were monitored using Finapres. Cardiac output, stroke volume (SV) and end-diastolic volume (EDV), and calculated total peripheral resistance (TPR) were recorded using thoracic electrical bioimpedance. An autonomic reflex screen which quantitates the distribution and severity of autonomic failure was also done. With the patient supine, all POTS patients (POTS-nf; POTS-f) had increased HR (p < 0.001) and reduced SV/EDV (p < 0.001) when compared with NLS. On tilt-up, POTS-f patients were significantly different from both NLS and POTS-nf patients; the most consistent alteration was a fall instead of an increase in TPR; other changes were a greater reduction in PP, a reduction (instead of an increment) in DAP, and a different pattern of changes during the Valsalva maneuver (excessive early phase II, attenuated or absent late phase II). Our results suggest alpha-adrenergic impairment with increased pooling or hypovolemia in POTS-f patients. We conclude that it is possible to identify the mechanism of syncope in POTS patients, and perhaps other patients with orthostatic intolerance and an excessive liability to syncope.

NASA Discipline Number 14-10↗

Effect of dynamic exercise on human carotid-cardiac baroreflex latency

We compared the beat-to-beat responses of heart rate (HR) after brief activation of carotid baroreceptors in resting humans with the responses obtained during mild-to-moderate levels of dynamic exercise [25 and 50% of peak O2 uptake (VO2peak)] to investigate the effect of exercise on baroreflex latency. Carotid baroreceptors were activated by a pressure pulse (5 s) of neck suction (NS, -80 Torr) and neck pressure (NP, +40 Torr) during held expiration. At rest the peak change in HR to NS/NP occurred during the first several heartbeats (1st-3rd beat), whereas during mild and moderate exercise peak HR responses occurred near the end of the NS/NP pulse (6th-8th beat). In contrast, time (s) to the peak change in HR was not different between rest and exercise (P > 0.05). Reflex tachycadia to NP progressively decreased during exercise (17 +/- 3, 10 +/- 1, and 4 +/- 1% of control, rest vs. 25% VO2peak, vs. 50% VO2peak, respectively, P < 0.05), and a strong positive correlation was found between the magnitude of the reflex tachycardia and a measure of HR variability (cardiac vagal tone index, r = 0.74, P < 0.0001). Reflex bradycardia to NS gradually increased during exercise (13 +/- 2, 17 +/- 2, and 18 +/- 2% of control, rest vs. 25% VO2peak, vs. 50% VO2peak, respectively, P = 0.10) and was negatively correlated with cardiac vagal tone (r = 0.42, P < 0.06).(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Program Space Physiology and Countermeasures↗

Influence of Gravity on Blood Volume and Flow Distribution

In our previous experiments during NASA Shuttle flights SLS 1 and 2 (9-15 days) and EUROMIR flights (30-90 days) we observed that pulmonary blood flow (cardiac output) was elevated initially, and surprisingly remained elevated for the duration of the flights. Stroke volume increased initially and then decreased, but was still above 1 Gz values. As venous return was constant, the changes in SV were secondary to modulation of heart rate. Mean blood pressure was at or slightly below 1 Gz levels in space, indicating a decrease in total peripheral resistance. It has been suggested that plasma volume is reduced in space, however cardiac output/venous return do not return to 1 Gz levels over the duration of flight. In spite of the increased cardiac output, central venous pressure was not elevated in space. These data suggest that there is a change in the basic relationship between cardiac output and central venous pressure, a persistent "hyperperfusion" and a re-distribution of blood flow and volume during space flight. Increased pulmonary blood flow has been reported to increase diffusing capacity in space, presumably due to the improved homogeneity of ventilation and perfusion. Other studies have suggested that ventilation may be independent of gravity, and perfusion may not be gravity- dependent. No data for the distribution of pulmonary blood volume were available for flight or simulated microgravity. Recent studies have suggested that the pulmonary vascular tree is influenced by sympathetic tone in a manner similar to that of the systemic system. This implies that the pulmonary circulation is dilated during microgravity and that the distribution of blood flow and volume may be influenced more by vascular control than by gravity. The cerebral circulation is influenced by sympathetic tone similarly to that of the systemic and pulmonary circulations; however its effects are modulated by cerebral autoregulation. Thus it is difficult to predict if cerebral perfusion is increased and if there is edema in space. Anecdotal evidence suggests there may be cerebral edema early in flight. Cerebral artery velocity has been shown to be elevated in simulated microgravity. The elevated cerebral artery velocity during simulated microgravity may reflect vasoconstriction of the arteries and not increased cerebral blood flow. The purpose of our investigations was to evaluate the effects of alterations in simulated gravity (+/-), resulting in changes in cardiac output (+/-), and on the blood flow and volume distribution in the lung and brain of human subjects. The first hypothesis of these studies was that blood flow and volume would be affected by gravity, but their distribution in the lung would be independent of gravity and due to vasoactivity changing vascular resistance in lung vessels. The vasodilitation of the lung vasculature (lower resistance) along with increased "compliance" of the heart could account for the absence of increased central venous pressure in microgravity. Secondly, we postulate that cerebral blood velocity is increased in microgravity due to large artery vasoconstriction, but that cerebral blood flow would be reduced due to autoregulation.

Pendergast, D.↗

Autoregulation of cerebral blood flow in orthostatic hypotension

BACKGROUND AND PURPOSE: We sought to evaluate cerebral autoregulation in patients with orthostatic hypotension (OH). METHODS: We studied 21 patients (aged 52 to 78 years) with neurogenic OH during 80 degrees head-up tilt. Blood flow velocities (BFV) from the middle cerebral artery were continuously monitored with transcranial Doppler sonography, as were heart rate, blood pressure (BP), cardiac output, stroke volume, CO2, total peripheral resistance, and cerebrovascular resistance. RESULTS: All OH patients had lower BP (P<.0001), BFV_diastolic (P<.05), CVR (P<.007), and TPR (P<.02) during head-up tilt than control subjects. In control subjects, no correlations between BFV and BP were found during head-up tilt, suggesting normal autoregulation. OH patients could be separated into those with normal or expanded autoregulation (OH_NA; n=16) and those with autoregulatory failure (OH_AF; n=5). The OH_NA group showed either no correlation between BFV and BP (n=8) or had a positive BFV/BP correlation (R2>.75) but with a flat slope. An expansion of the "autoregulated" range was seen in some patients. The OH_AF group was characterized by a profound fall in BFV in response to a small reduction in BP (mean deltaBP <40 mm Hg; R2>.75). CONCLUSIONS: The most common patterns of cerebral response to OH are autoregulatory failure with a flat flow-pressure relationship or intact autoregulation with an expanded autoregulated range. The least common pattern is autoregulatory failure with a steep flow-pressure relationship. Patients with patterns 1 and 2 have an enhanced capacity to cope with OH, while those with pattern 3 have reduced capacity.

Non-NASA Center↗

Physiological response of rats to delivery of helium and xenon: implications for hyperpolarized noble gas imaging

The physiological effects of various hyperpolarized helium and xenon MRI-compatible breathing protocols were investigated in 17 Sprague-Dawley rats, by continuous monitoring of blood oxygen saturation, heart rate, EKG, temperature and endotracheal pressure. The protocols included alternating breaths of pure noble gas and oxygen, continuous breaths of pure noble gas, breath-holds of pure noble gas for varying durations, and helium breath-holds preceded by two helium rinses. Alternate-breath protocols up to 128 breaths caused a decrease in oxygen saturation level of less than 5% for either helium or xenon, whereas 16 continuous-breaths caused a 31.5% +/- 2.3% decrease in oxygen saturation for helium and a 30.7% +/- 1. 3% decrease for xenon. Breath-hold protocols up to 25 s did not cause the oxygen saturation to fall below 90% for either of the noble gases. Oxygen saturation values below 90% are considered pathological. At 30 s of breath-hold, the blood oxygen saturation dropped precipitously to 82% +/- 0.6% for helium, and to 76.5% +/- 7. 4% for xenon. Breath-holds longer than 10 s preceded by pre-rinses caused oxygen saturation to drop below 90%. These findings demonstrate the need for standardized noble gas inhalation procedures that have been carefully tested, and for continuous physiological monitoring to ensure the safety of the subject. We find short breath-hold and alternate-breath protocols to be safe procedures for use in hyperpolarized noble gas MRI experiments. Copyright 2000 John Wiley & Sons, Ltd.

NASA Discipline Life Sciences Technologies↗

Changes in autonomic activity preceding onset of nonsustained ventricular tachycardia

Background: The triggering role of the autonomic nervous system in the initiation of ventricular tachycardia has not been established. To investigate the relationship between changes in autonomic activity and the occurrence of nonsustained ventricular tachycardia (NSVT) we examined heart rate variability (HRV) during the 2-hour period preceding spontaneous episodes of NSVT. Twenty-four subjects were identified retrospectively as having had one episode of NSVT during 24-hour Holter ECC recording. Methods: We measured the mean interval between normal heats (meanRR), the standard deviation of the intervals between beats (SD), the percentage of counts of sequential intervals between normal beats with a change of >50 ms (%RR50), the logarithms of low- and high-frequency spectral components (lnLF, lnHF) of HRV for sequential 10-minute segments preceding NSVT. The correlation dimension (CDim) of HRV was calculated similarly for sequential 20-minute segments. We assessed the significance of the time-course change of each marker over the 120-minute period prior to NSVT onset. Results: MeanRR (P < 0.05), lnLF (P < 0.0001), lnHF (P < 0.0001), the natural logarithm of the ratio of LF to HF (ln[LF/HF]; P < 0.05), and CDim (P < 0.05) showed significant time-course changes during that period, while SD and %RR50 did not. MeanRR, lnLF, lnHF, and CDim all decreased prior to the onset of NSVT, whereas ln(LF/HF) increased. We divided the subjects into two groups: one consisting of 12 patients with coronary artery disease; and the second group of 12 patients without known coronary artery disease. Both groups showed significant changes (P < 0.05) of CDim, lnLF, and lnHF preceding the episodes of NSVT. Conclusions: Changes in the pattern of HRV prior to the onset of episodes of NSVT suggest that changes in autonomic activity may commonly play a role in the triggering of spontaneous episodes of NSVT in susceptible patients. The measured changes suggest a reduction in parasympathetic activity, perhaps in conjunction with an increase in sympathetic activity, may trigger NSVT.

Non-NASA Center↗

T wave alternans as a predictor of recurrent ventricular tachyarrhythmias in ICD recipients: prospective comparison with conventional risk markers

INTRODUCTION: The current standard for arrhythmic risk stratification is electrophysiologic (EP) testing, which, due to its invasive nature, is limited to patients already known to be at high risk. A number of noninvasive tests, such as determination of left ventricular ejection fraction (LVEF) or heart rate variability, have been evaluated as additional risk stratifiers. Microvolt T wave alternans (TWA) is a promising new risk marker. Prospective evaluation of noninvasive risk markers in low- or moderate-risk populations requires studies involving very large numbers of patients, and in such studies, documentation of the occurrence of ventricular tachyarrhythmias is difficult. In the present study, we identified a high-risk population, recipients of an implantable cardioverter defibrillator (ICD), and prospectively compared microvolt TWA with invasive EP testing and other risk markers with respect to their ability to predict recurrence of ventricular tachyarrhythmias as documented by ICD electrograms. METHODS AND RESULTS: Ninety-five patients with a history of ventricular tachyarrhythmias undergoing implantation of an ICD underwent EP testing, assessment of TWA, as well as determination of LVEF, baroreflex sensitivity, signal-averaged ECG, analysis of 24-hour Holter monitoring, and QT dispersion from the 12-lead surface ECG. The endpoint of the study was first appropriate ICD therapy for electrogram-documented ventricular fibrillation or tachycardia during follow-up. Kaplan-Meier survival analysis revealed that TWA (P < 0.006) and LVEF (P < 0.04) were the only significant univariate risk stratifiers. EP testing was not statistically significant (P < 0.2). Multivariate Cox regression analysis revealed that TWA was the only statistically significant independent risk factor. CONCLUSIONS: Measurement of microvolt TWA compared favorably with both invasive EP testing and other currently used noninvasive risk assessment methods in predicting recurrence of ventricular tachyarrhythmias in ICD recipients. This study suggests that TWA might also be a powerful tool for risk stratification in low- or moderate-risk patients, and needs to be prospectively evaluated in such populations.

Non-NASA Center↗

Comparison of aortic and carotid baroreflex stimulus-response characteristics in humans

In order to characterize the stimulus-response relationships of the arterial, aortic, and carotid baroreflexes in mediating cardiac chronotropic function, we measured heart rate (HR) responses elicited by acute changes in mean arterial pressure (MAP) and carotid sinus pressure (CSP) in 11 healthy individuals. Arterial (aortic + carotid) baroreflex control of HR was quantified using ramped changes in MAP induced by bolus injection of phenylephrine (PE) and sodium nitroprusside (SN). To assess aortic-cardiac responses, neck pressure (NP) and suction (NS) were applied during PE and SN administration, respectively, to counter alterations in CSP thereby isolating the aortic baroreflex. Graded levels of NP and NS were delivered to the carotid sinus using a customized neck collar device to assess the carotid-cardiac baroreflex, independent of drug infusion. The operating characteristics of each reflex were determined from the logistic function of the elicited HR response to the induced change in MAP. The arterial pressures at which the threshold was located on the stimulus-response curves determined for the arterial, aortic and carotid baroreflexes were not significantly different (72+/-4, 67+/-3, and 72+/-4 mm Hg, respectively, P > 0.05). Similarly, the MAP at which the saturation of the reflex responses were elicited did not differ among the baroreflex arcs examined (98+/-3, 99+/-2, and 102+/-3 mm Hg, respectively). These data suggest that the baroreceptor populations studied operate over the same range of arterial pressures. This finding indicates each baroreflex functions as both an important anti-hypotensive and anti-hypertensive mechanism. In addition, this investigation describes a model of aortic baroreflex function in normal healthy humans, which may prove useful in identifying the origin of baroreflex dysfunction in disease- and training-induced conditions.

Non-NASA Center↗

Age alters the cardiovascular response to direct passive heating

During direct passive heating in young men, a dramatic increase in skin blood flow is achieved by a rise in cardiac output (Qc) and redistribution of flow from the splanchnic and renal vascular beds. To examine the effect of age on these responses, seven young (Y; 23 +/- 1 yr) and seven older (O; 70 +/- 3 yr) men were passively heated with water-perfused suits to their individual limit of thermal tolerance. Measurements included heart rate (HR), Qc (by acetylene rebreathing), central venous pressure (via peripherally inserted central catheter), blood pressures (by brachial auscultation), skin blood flow (from increases in forearm blood flow by venous occlusion plethysmography), splanchnic blood flow (by indocyanine green clearance), renal blood flow (by p-aminohippurate clearance), and esophageal and mean skin temperatures. Qc was significantly lower in the older than in the young men (11.1 +/- 0.7 and 7.4 +/- 0.2 l/min in Y and O, respectively, at the limit of thermal tolerance; P < 0. 05), despite similar increases in esophageal and mean skin temperatures and time to reach the limit of thermal tolerance. A lower stroke volume (99 +/- 7 and 68 +/- 4 ml/beat in Y and O, respectively, P < 0.05), most likely due to an attenuated increase in inotropic function during heating, was the primary factor for the lower Qc observed in the older men. Increases in HR were similar in the young and older men; however, when expressed as a percentage of maximal HR, the older men relied on a greater proportion of their chronotropic reserve to obtain the same HR response (62 +/- 3 and 75 +/- 4% maximal HR in Y and O, respectively, P < 0.05). Furthermore, the older men redistributed less blood flow from the combined splanchnic and renal circulations at the limit of thermal tolerance (960 +/- 80 and 720 +/- 100 ml/min in Y and O, respectively, P < 0. 05). As a result of these combined attenuated responses, the older men had a significantly lower increase in total blood flow directed to the skin.

Clinical Trial↗

Cardiovascular function following reduced aerobic activity

PURPOSE: The aim of this study was to test the hypothesis that a sustained reduction of physical activity (deconditioning) would alter the cardiovascular regulatory function. METHODS: Nineteen young, healthy volunteers participated in physical deconditioning for a period of 8 wk. Before (pre) and following (post) physical deconditioning, the responses of heart rate (HR), mean arterial pressure (MAP, measured by Finapres), central venous pressure (CVP), stroke volume (SV, Doppler), and forearm blood flow (FBF, plethysmography) were determined during lower body negative pressure (LBNP). The carotid baroreflex (CBR) function was assessed using a train of pulsatile neck pressure (NP) and suction, and the aortic baroreflex control of HR was assessed during steady-state phenylephrine (PE) infusion superimposed by LBNP and NP to counteract the PE increased CVP and carotid sinus pressure, respectively. RESULTS: Active physical deconditioning significantly decreased maximal oxygen uptake (-7%) and LBNP tolerance (-13%) without a change in baseline hemodynamics. Plasma volume (-3% at P = 0.135), determined by Evans Blue dilution, and blood volume (-4% at P = 0.107) were not significantly altered. During LBNP -20 to -50 torr, there was a significantly greater drop of SV per unit decrease in CVP in the post- (14.7 +/- 1.6%/mm Hg) than predeconditioning (11.2 +/- 0.7%/mm Hg) test accompanied by a greater tachycardia. Deconditioning increased the aortic baroreflex sensitivity (pre vs post: -0.61 +/- 0.12 vs -0.84 +/- 0.14 bpm.mm-1 Hg, P = 0.009) and the slope of forearm vascular resistance (calculated from [MAP-CVP]/FBF) to CVP (-2.75 +/- 0.26 vs -4.94 +/- 0.97 PRU/mm Hg, P = 0.086). However, neither the CBR-HR (-0.28 +/- 0.03 VS -0.39 +/- 0.10 bpm.mm-1 Hg) nor the CBR-MAP (-0.37 +/- 0.16 vs -0.25 +/- 0.07 mm Hg/mm Hg) gains were statistically different between pre- and postdeconditioning. CONCLUSIONS: We concluded that the functional modification of the cardiac pressure-volume relationship resulted in the reduced LBNP tolerance, despite the accentuated aortic and cardiopulmonary baroreflex function following deconditioning.

Non-NASA Center↗

Effects of volume loading and pressor agents in idiopathic orthostatic tachycardia

BACKGROUND: Idiopathic orthostatic tachycardia (IOT) is characterized by an increase in heart rate (HR) with standing of > or = 30 bpm that is associated with elevated catecholamine levels and orthostatic symptoms. A dynamic orthostatic hypovolemia and alpha1-adrenoreceptor hypersensitivity have been demonstrated in IOT patients. There is evidence of an autonomic neuropathy affecting the lower-extremity blood vessels. METHODS AND RESULTS: We studied the effects of placebo, the alpha1-adrenoreceptor agonist midodrine (5 to 10 mg), the alpha2-adrenoreceptor agonist clonidine (0.1 mg), and I.V. saline (1 L) in 13 patients with IOT. Supine and upright blood pressure (BP) and HR were measured before and at 1 and 2 hours after intervention. Midodrine decreased both supine and upright HR (all HR values are given as bpm) at 2 hours (from 78+/-2 supine to 108+/-5 upright before treatment and from 69+/-2 supine to 95+/-5 upright after treatment, P<.005 for supine and P<.01 for upright). Saline decreased both supine and upright HR (from 80+/-3 supine to 112+/-5 upright before infusion and from 77+/-3 supine to 91+/-3 upright 1 hour after infusion, P<.005 for supine and P<.001 for upright). Clonidine decreased supine HR (from 78+/-2 to 74+/-2, P<.03) but did not affect the HR increase with standing. Clonidine very significantly decreased supine systolic BP (from 109+/-3 at baseline to 99+/-2 mm Hg at 2 hours, P<.001), and midodrine decreased supine systolic BP mildly. CONCLUSIONS: IOT responds best acutely to saline infusion to correct the underlying hypovolemia. Chronically, this can be accomplished with increased salt and water intake in conjunction with fludrocortisone. The response of patients to the alpha1-agonist midodrine supports the hypothesis of partial dysautonomia and indicates that the use of alpha1-agonists to pharmacologically replace lower-extremity postganglionic sympathetics is an appropriate overall goal of therapy. These findings are consistent with our hypothesis that the tachycardia and elevated catecholamine levels associated with IOT are principally due to hypovolemia and loss of adequate lower-extremity vascular tone.

Non-NASA Center↗

MetaHeart: Metasurface enabled biometrics camouflage

Privacy-invading biometrics monitoring is becoming a prominent security threat as modern sensing systems move to higher operating frequencies (mmWave, sub-THz), increasing sensing resolution and accuracy. As such, developing systems that can protect or obfuscate biometrics from adversarial intrusion becomes pivotal to preserving user privacy. In this work, we develop and implement MetaHeart, a real-time biometrics misinformation system based on reflective, programmable metasurfaces and dynamic phase-front manipulation of radar inferences. MetaHeart’s key goal is to prevent the leakage of a legitimate user’s heartbeat biometrics by spoofing fake heartbeat signals at a malicious, radar-equipped, heart rate sensing intruder. Furthermore, we experimentally demonstrate MetaHeart’s ability to fake Alice’s presence when she is not there and to fool Trudy’s inferences even when Alice is present, achieving an overall accuracy above 98%. Finally, we conduct a robustness analysis to determine MetaHeart’s required spatial placement within the intruder’s monitoring area that would allow for effective spoofing.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Exploring thermal state in mixed immersive virtual environments

Combining immersive virtual environment (IVE) with a controlled environment is a potential solution for analyzing human thermal experience during building design. Existing studies in this field have not adequately analyzed scenarios involving stabilized comfortable and uncomfortable temperature conditions using both thermal state votes and physiological responses, or the influence of the seasons. By combining IVE with a climate chamber, called mixed IVE (MIVE) in this study, experiments were conducted to test the hypothesis that participants' virtual experience did not significantly alter their thermal experience compared to their in-situ experience. Response variables were the control temperature distribution, the thermal state vote (at temperature steps 18.3 °C, 23.8 °C, and 29.4 °C), and physiological responses (heart rate and skin temperature). The results show that the first two response variables were not significantly different between the MIVE and in-situ settings (except for one case). Due to the heat development of the head mounted display device, the mean forehead skin temperature in the MIVE experiments was significantly higher than that in the in-situ experiments in most cases. Furthermore, such difference in skin temperature did not seem to affect general thermal state votes. In addition, significant skin temperature differences at some locations were also observed between the MIVE and in-situ settings.

42 ENGINEERING↗

Do we owe our existence to gravitational waves?

Two heavy elements essential to human biology are thought to have been produced by the astrophysical r-process, which occurs in neutron-rich environments: iodine is a constituent of thyroid hormones that affect many physiological processes including growth and development, body temperature and heart rate, and bromine is essential for tissue development and architecture. Collisions of neutron stars (kilonovae) have been identified as sources of r-process elements including tellurium, which is adjacent to iodine in the periodic table, and lanthanides. Neutron-star collisions arise from energy loss due to gravitational-wave emission from binary systems, leading us to suggest that gravitational waves have played a key role in enabling human life by producing iodine and bromine. We propose probing this proposal by searching in lunar material for live 129 I deposited by a recent nearby kilonova explosion.

Human biochemistry↗

Electrocardiographic changes predate Parkinson’s disease onset

Autonomic nervous system involvement precedes the motor features of Parkinson’s disease (PD). Our goal was to develop a proof-of-concept model for identifying subjects at high risk of developing PD by analysis of cardiac electrical activity. We used standard 10-s electrocardiogram (ECG) recordings of 60 subjects from the Honolulu Asia Aging Study including 10 with prevalent PD, 25 with prodromal PD, and 25 controls who never developed PD. Various methods were implemented to extract features from ECGs including simple heart rate variability (HRV) metrics, commonly used signal processing methods, and a Probabilistic Symbolic Pattern Recognition (PSPR) method. Extracted features were analyzed via stepwise logistic regression to distinguish between prodromal cases and controls. Stepwise logistic regression selected four features from PSPR as predictors of PD. The final regression model built on the entire dataset provided an area under receiver operating characteristics curve (AUC) with 95% confidence interval of 0.90 [0.80, 0.99]. The five-fold cross-validation process produced an average AUC of 0.835 [0.831, 0.839]. We conclude that cardiac electrical activity provides important information about the likelihood of future PD not captured by classical HRV metrics. Machine learning applied to ECGs may help identify subjects at high risk of having prodromal PD.

59 BASIC BIOLOGICAL SCIENCES↗

Ultrafast two-photon fluorescence imaging of cerebral blood circulation in the mouse brain in vivo

Characterizing blood flow dynamics in vivo is critical to understanding the function of the vascular network under physiological and pathological conditions. Existing methods for hemodynamic imaging have insufficient spatial and temporal resolution to monitor blood flow at the cellular level in large blood vessels. By using an ultrafast line-scanning module based on free-space angular chirped enhanced delay, we achieved two-photon fluorescence imaging of cortical blood flow at 1,000 two-dimensional (2D) frames and 1,000,000 one-dimensional line scans per second in the awake mouse. This orders-of-magnitude increase in temporal resolution allowed us to measure cerebral blood flow at up to 49 mm/s and observe pulsatile blood flow at harmonics of heart rate. Directly visualizing red blood cell (RBC) flow through vessels down to >800 µm in depth, we characterized cortical layer–dependent flow velocity distributions of capillaries, obtained radial velocity profiles and kilohertz 2D velocity mapping of multifile blood flow, and performed RBC flux measurements from penetrating blood vessels.

59 BASIC BIOLOGICAL SCIENCES↗

Myosin in autoinhibited off state(s), stabilized by mavacamten, can be recruited in response to inotropic interventions

Mavacamten is a FDA-approved small-molecule therapeutic designed to regulate cardiac function at the sarcomere level by selectively but reversibly inhibiting the enzymatic activity of myosin. It shifts myosin toward ordered off states close to the thick filament backbone. It remains elusive whether these myosin heads in the off state(s) can be recruited in response to physiological stimuli when required to boost cardiac output. We show that cardiac myosins stabilized in these off state(s) by mavacamten are recruitable by 1) Ca 2+ , 2) increased chronotropy [heart rate (HR)], 3) stretch, and 4) β-adrenergic (β-AR) stimulation, all known physiological inotropic interventions. At the molecular level, we show that Ca 2+ increases myosin ATPase activity by shifting mavacamten-stabilized myosin heads from the inactive super-relaxed state to the active disordered relaxed state. At the myofilament level, both Ca 2+ and passive lengthening can shift mavacamten-ordered off myosin heads from positions close to the thick filament backbone to disordered on states closer to the thin filaments. In isolated rat cardiomyocytes, increased stimulation rates enhanced shortening fraction in mavacamten-treated cells. This observation was confirmed in vivo in telemetered rats, where left-ventricular dP/dt max , an index of inotropy, increased with HR in mavacamten-treated animals. Finally, we show that β-AR stimulation in vivo increases left-ventricular function and stroke volume in the setting of mavacamten. Our data demonstrate that the mavacamten-promoted off states of myosin in the thick filament are at least partially activable, thus preserving cardiac reserve mechanisms.

59 BASIC BIOLOGICAL SCIENCES↗

Superiority of compensatory reserve measurement compared with the Shock index for early and accurate detection of reduced central blood volume status

Shock index (SI) equals the ratio of heart rate (HR) to systolic blood pressure (SBP) with clinical evidence that it is more sensitive for trauma patient status assessment and prediction of outcome compared with either HR or SBP alone. We used lower body negative pressure (LBNP) as a human model of central hypovolemia and compensatory reserve measurement (CRM) validated for accurate tracking of reduced central blood volume to test the hypotheses that SI: (1) presents a late signal of central blood volume status; (2) displays poor sensitivity and specificity for predicting the onset of hemodynamic decompensation; and (3) cannot identify individuals at greatest risk for the onset of circulatory shock. We measured HR, SBP, and CRM in 172 human subjects (19–55 years) during progressive LBNP designed to determine tolerance to central hypovolemia as a model of hemorrhage. Subjects were subsequently divided into those with high tolerance (HT) (n = 118) and low tolerance (LT) (n = 54) based on completion of 60 mm Hg LBNP. The time course relationship between SI and CRM was determined and receiver operating characteristic (ROC) area under the curve (AUC) was calculated for sensitivity and specificity of CRM and SI to predict hemodynamic decompensation using clinically defined thresholds of 40% for CRM and 0.9 for SI. The time and level of LBNP required to reach a SI = 0.9 (~60 mm Hg LBNP) was significantly greater (p < 0.001) compared with CRM that reached 40% at ~40 mm Hg LBNP. Shock index did not differ between HT and LT subjects at 45 mm Hg LBNP levels. ROC AUC for CRM was 0.95 (95% CI = 0.94–0.97) compared with 0.91 (0.89–0.94) for SI (p = 0.0002). Despite high sensitivity and specificity, SI delays time to detect reductions in central blood volume with failure to distinguish individuals with varying tolerances to central hypovolemia.

60 APPLIED LIFE SCIENCES↗