Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “geometric models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Facility Targeting, Protection and Mission Decision Making Using the VISAC Code

The Visual Interactive Site Analysis Code (VISAC) is a Java-based graphical expert system developed by ORNL for the Defense Threat Reduction Agency, Nuclear Regulatory Commission (NRC) and other sponsors to aid in targeting facilities and to predict the associated collateral effects for the go, no go mission decision making process. VISAC integrates the three concepts of target geometric modeling, damage assessment capabilities, and an event/fault tree methodology for evaluating accident/incident consequences. It can analyze a variety of accidents/incidents at nuclear or industrial facilities, ranging from simple component sabotage to an attack with military or terroist weapons. For nuclear facilities, VISAC predicts the facility damage, estimated downtime, amount and timing of any radionuclides released. used in conunction with DTRA's HPAC code, VISAC also can analyze transport and dispersion of the radionuclides, levels of contamination of the surrounding area, and the population at risk. VISAC has also been used by the NRC to aid in the development of protective measures for nuclear facilities that may be subjected to attacks by car/truck bombs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Constructing Gold-Thiolate Oligomers and Polymers on Au(111) Based on the Linear S-Au-S Geometry

Although neat gold-thiolate oligomers and polymers made of linear S-Au-S bonds have been well-known, observation of RS-Au-SR linear complexes (RS- being an alkylthiolate group) on Au(111) has been reported only recently. On the basis of the unique geometry and bonding of the RS-Au-SR complex on Au(111), we construct simple geometric models of Au-SR oligomers and polymers on Au(111) by fusing linear S-Au-S units matched to the underlying Au(111) surface lattice. We then optimize these models by density functional theory. The hexagonal geometry of the Au(111) lattice determines three possible angles (60{sup o}, 120{sup o}, and 180{sup o}) for connecting two linear S-Au-S units, which lead to isomerism of the Au-SR oligomers and polymer on Au(111). Here we explore open dimers, trimers, and tetramers and cyclic trimers, tetramers, and hexamers of the Au-SR oligomers on Au(111). We also examine four isomers of the Au-SR polymer on Au(111). We find that the 120{sup o} Au-S-Au angle is preferred in constructing both oligomeric and polymeric isomers. The two polymeric isomers with 120{sup o} Au-S-Au angles are found to be energetically competitive with a previous model proposed for the Au-SR polymer on Au(111). We also discuss potential ways to create Au-SR oligomers on Au(111).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Iterative Reconstruction of Coded Source Neutron Radiographs

Use of a coded source facilitates high-resolution neutron imaging but requires that the radiographic data be deconvolved. In this paper, we compare direct deconvolution with two different iterative algorithms, namely, one based on direct deconvolution embedded in an MLE-like framework and one based on a geometric model of the neutron beam and a least squares formulation of the inverse imaging problem.

Coded Source Imaging↗

Flammability Analysis For Actinide Oxides Packaged In 9975 Shipping Containers

Packaging options are evaluated for compliance with safety requirements for shipment of mixed actinide oxides packaged in a 9975 Primary Containment Vessel (PCV). Radiolytic gas generation rates, PCV internal gas pressures, and shipping windows (times to reach unacceptable gas compositions or pressures after closure of the PCV) are calculated for shipment of a 9975 PCV containing a plastic bottle filled with plutonium and uranium oxides with a selected isotopic composition. G-values for radiolytic hydrogen generation from adsorbed moisture are estimated from the results of gas generation tests for plutonium oxide and uranium oxide doped with curium-244. The radiolytic generation of hydrogen from the plastic bottle is calculated using a geometric model for alpha particle deposition in the bottle wall. The temperature of the PCV during shipment is estimated from the results of finite element heat transfer analyses.

42 ENGINEERING↗

SCALE 6.2 Continuous-Energy TSUNAMI-3D Capabilities

The TSUNAMI (Tools for Sensitivity and UNcertainty Analysis Methodology Implementation) capabilities within the SCALE code system make use of sensitivity coefficients for an extensive number of criticality safety applications, such as quantifying the data-induced uncertainty in the eigenvalue of critical systems, assessing the neutronic similarity between different systems, quantifying computational biases, and guiding nuclear data adjustment studies. The need to model geometrically complex systems with improved ease of use and fidelity and the desire to extend TSUNAMI analysis to advanced applications have motivated the development of a SCALE 6.2 module for calculating sensitivity coefficients using three-dimensional (3D) continuous-energy (CE) Monte Carlo methods: CE TSUNAMI-3D. This paper provides an overview of the theory, implementation, and capabilities of the CE TSUNAMI-3D sensitivity analysis methods. CE TSUNAMI contains two methods for calculating sensitivity coefficients in eigenvalue sensitivity applications: (1) the Iterated Fission Probability (IFP) method and (2) the Contributon-Linked eigenvalue sensitivity/Uncertainty estimation via Track length importance CHaracterization (CLUTCH) method. This work also presents the GEneralized Adjoint Response in Monte Carlo method (GEAR-MC), a first-of-its-kind approach for calculating adjoint-weighted, generalized response sensitivity coefficients—such as flux responses or reaction rate ratios—in CE Monte Carlo applications. The accuracy and efficiency of the CE TSUNAMI-3D eigenvalue sensitivity methods are assessed from a user perspective in a companion publication, and the accuracy and features of the CE TSUNAMI-3D GEAR-MC methods are detailed in this paper.

42 ENGINEERING↗

CFD Analysis of Upper Plenum Flow for a Sodium-Cooled Small Modular Reactor

Upper plenum flow behavior is important for many operational and safety issues in sodium fast reactors. The Prototype Gen-IV Sodium Fast Reactor (PGSFR), a pool-type, 150 MWe output power design, was used as a reference case for a detailed characterization of upper plenum flow for normal operating conditions. Computational Fluid Dynamics (CFD) simulation was utilized with detailed geometric modeling of major structures. Core outlet conditions based on prior system-level calculations were mapped to approximate the outlet temperatures and flow rates for each core assembly. Core outlet flow was found to largely bypass the Upper Internal Structures (UIS). Flow curves over the shield and circulates within the pool before exiting the plenum. Cross-flows and temperatures were evaluated near the core outlet, leading to a proposed height for the core outlet thermocouples to ensure accurate assembly-specific temperature readings. A passive scalar was used to evaluate fluid residence time from core outlet to IHX inlet, which can be used to assess the applicability of various methods for monitoring fuel failure. Additionally, the gas entrainment likelihood was assessed based on the CFD simulation results. Based on the evaluation of velocity gradients and turbulent kinetic energies and the available gas entrainment criteria in the literature, it was concluded that significant gas entrainment is unlikely for the current PGSFR design.

computational fluid dynamics↗

DOSE RATE VERIFICATION FOR SNS SPENT STRUCTURES

Residual dose rate measurements were conducted on two Spallation Neutron Source spent structures, target vessel #13 and proton beam window #5, after extraction from their service locations. These measurements were used to verify calculation methods for radionuclide inventory assessment that are typically performed for nuclear waste characterization and transportation. Neutronics analyses for predicting residual dose rates were carried out using complex and rigorous geometric models of the structures and their surroundings. Calculational results were analyzed and compared to the measured dose rates

Popova, Irina I.↗

Experimental and Numerical Investigations on Dynamic Mechanical Properties of TPMS Structures

Triply Periodic Minimal Surface (TPMS) lattice structures have been of increasing interest due to their light weighting, enhanced mechanical properties, and energy absorption characteristics for automotive and biomedical applications. With the advent of additive manufacturing and geometric modeling software, TPMS lattices with complex geometries can be realized. In this work, TPMS lattice structures were fabricated with PLA using fused filament fabrication (FFF) and their dynamic properties are characterized through drop tower experiments. Although lightweight TPMS lattices are beneficial for their impact absorption capability, most of the existing works are limited to quasi-static compression and dynamic impact tests are rarely performed. The current study investigates the stress-strain and energy absorption characteristics of TPMS lattices through drop tower testing and numerical modeling. Finite element modeling for TPMS lattices is carried out to validate the experimental responses. The mechanical properties, deformation, and failure mechanisms of TPMS lattices under dynamic impact are summarized for potential future applications.

Pokkalla, Deepak↗

Development of a coupling code for PWR reactor cavity radiation streaming calculation

PWR reactor cavity radiation streaming is important for the safe of the personnel and equipment, thus calculation has to be performed to evaluate the neutron flux distribution around the reactor. For this calculation, the deterministic codes have difficulties in fine geometrical modeling and need huge computer resource; and the Monte Carlo codes require very long sampling time to obtain results with acceptable precision. Therefore, a coupling method has been developed to eliminate the two problems mentioned above in each code. In this study, we develop a coupling code named DORT2MCNP to link the Sn code DORT and Monte Carlo code MCNP. DORT2MCNP is used to produce a combined surface source containing top, bottom and side surface simultaneously. Because SDEF card is unsuitable for the combined surface source, we modify the SOURCE subroutine of MCNP and compile MCNP for this application. Numerical results demonstrate the correctness of the coupling code DORT2MCNP and show reasonable agreement between the coupling method and the other two codes (DORT and MCNP). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of the JENDL-4.0 nuclear data set for uncertainty analysis of the prototype FBR Monju

This paper deals with uncertainty analysis of the Monju reactor using JENDL-4.0 and the ERANOS code 1. In 2010 the Japan Atomic Energy Agency - JAEA - released the JENDL-4.0 nuclear data set. This new evaluation contains improved values of cross-sections and emphasizes accurate covariance matrices. Also in 2010, JAEA restarted the sodium-cooled fast reactor prototype Monju after about 15 years of shutdown. The long shutdown time resulted in a build-up of {sup 241}Am by natural decay from the initially loaded Pu. As well as improved covariance matrices, JENDL-4.0 is announced to contain improved data for minor actinides 2. The choice of Monju reactor as an application of the new evaluation seems then even more relevant. The uncertainty analysis requires the determination of sensitivity coefficients. The well-established ERANOS code was chosen because of its integrated modules that allow users to perform sensitivity and uncertainty analysis. A JENDL-4.0 cross-sections library is not available for ERANOS. Therefor a cross-sections library had to be made from the original ENDF files for the ECCO cell code (part of ERANOS). For confirmation of the newly made library, calculations of a benchmark core were performed. These calculations used the MZA and MZB benchmarks and showed consistent results with other libraries. Calculations for the Monju reactor were performed using hexagonal 3D geometry and PN transport theory. However, the ERANOS sensitivity modules cannot use the resulting fluxes, as these modules require finite differences based fluxes, obtained from RZ SN-transport or 3D diffusion calculations. The corresponding geometrical models have been made and the results verified with Monju restart experimental data 4. Uncertainty analysis was performed using the RZ model. JENDL-4.0 uncertainty analysis showed a significant reduction of the uncertainty related to the fission cross-section of Pu along with an increase of the uncertainty related to the capture cross-section of {sup 238}U compared with the previous JENDL-3.3 version. Covariance data recently added in JENDL-4.0 for {sup 241}Am appears to have a non-negligible contribution. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

3D Reconstruction, Augmented Reality, and Telerobotic Operation - 18297

For nuclear facility decommissioning and waste cleanup, it is necessary to deploy simple and robust robots in remote sites performing precise and dexterous manipulation under teleoperation. To meet the challenge, this paper presents a new remote operation method based on augmented reality for intuitive and efficient teleoperation. The enhanced teleoperation system incorporates three technology components - 3D sensing and reconstruction, augmented reality, and teleoperation. The 3D reconstruction technology utilizes 3D cameras and constructs a 3D geometric model of the environment. Compared to the state-of-the- art technology, the presented 3D reconstruction has greater spatial precision and dynamic object tracking capability, which enhances the precision of manipulation tasks in a dynamic environment. The augmented reality technology entails generation of virtual surfaces of various geometries and dynamic characteristics, as well as consistent perceptual overlay in camera, robot and operator hand control spaces. Teleoperation is demonstrated with a dual-arm robot system operated under Robot Operating System (ROS). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

First Step in Validating the Radiological Inventories of the Current French Nuclear Fleet - 19000

To anticipate the evolution of the mechanical characteristics of its PWR vessels, EDF developed a vessels fluence monitoring program. This program was based on vessel samples and neutron dosimeters deployed between the fuel assemblies and vessels. These samples and dosimeters are regularly analyzed in laboratories. To calculate the radioactive inventories, we have developed a calculation scheme which includes a 3D mapping of the neutron flux, the calculation of the radiological inventories of the structures of interest, and finally the validation of the results. The validation needs samples to propose calculation/measurement ratios. Unfortunately before the final shut down, the internal and vessel samplings are not possible. To anticipate the decommissioning of the current French nuclear fleet, this paper shows how the samples of the vessels fluence monitoring program can be used to validate the calculated radiological inventories. Using state-of-the-art simulations (i.e. 3D geometric model, 3D neutron sources, 3D neutron propagation, operational fuel loading coupled with effective power distributions) we calculated the radiological inventories of some vessel fluence monitoring program samples. The comparisons between calculated and measured results were done on 'standard chemical elements'. To qualify a chemical element as 'standard', many criteria must be satisfied such as a high concentration level, a low uncertainty about concentration, activation into an expanded cross section range, production of radionuclides having significant half-lives and finally no difficulties measuring the radionuclides produced. The retained 'standard' is Fe which produces, under neutrons flux, Fe-55. The comparisons show that the calculations slightly overestimate the measurements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Commissioning of Robotic Inspection and Automated Analysis System for Assay of Gas Diffusion Piping - 19500

Robotic, in-pipe, nondestructive assay (NDA) is a revolutionary and important means for measuring, analyzing, and reporting radioactive holdup deposits in enrichment piping. This innovation promises vast advantages for efficiency, safety, and cost savings. Payoff, however, lies in utilization much more than innovation. Crossing that threshold from a technical capability to an everyday tool occurs only after rigorous commissioning, adoption, and infusion. This must meet the highest standard, and there can be no compromise. Certification of a new NDA technology must meet the highest standards for quality, safety, and efficacy. Prior to this work, there was no precedent of procedure and method for certification of a robotic methodology for this purpose. The best of robotics had not certified NDA. The best of NDA had not certified robotics. Hence, a great deal of discovery, resourcefulness, and collaboration contributed to this success. This paper chronicles the first-of-kind chartering, co-development, testing, documentation, and site integration that certified this trailblazing in-pipe, robotic NDA. Commissioning had to demonstrate and certify end-to-end NDA automation from robot traversal to computer analysis to report generation of contaminated process piping at the Portsmouth, Ohio gaseous diffusion facility. This was a rigorous campaign of tests, evaluations, and documentation. Highlights included multiple tests in four elevated pipes exercised the gamut of NDA and robotic capabilities. Each of the four test pipes presented a unique loading of U-235. The tests demonstrated operations in both 30- inch and 42-inch diameter pipes with varying lengths and terminated by a variety of valves and fittings. Tests in a fifth pipe at floor level demonstrated deployment and applicability for pipes at this ground height and robot recognition of another fitting type. All operations, calibration, deployment, auto-reporting, and analysis were handled by Portsmouth site personnel. These tests concluded a series of component-level acceptance tests which certified all constituent technologies and operational features. Test metrics included comparison of reported to ground truth results and assessment of data quality from quality assurance and replicate measurement comparison. Beyond the radiometry associated with any NDA method, this unique commissioning path exercised and evaluated all the robotic features that are intrinsic to automation. These include odometry, geometric modeling, autonomy, remote launch and recovery, and end-to-end data flow. Each of these required verification and certification. These evaluations were first-of-kind for the decommissioning community, requiring innovation and resourcefulness in their own right. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dose rate verification for SNS spent structures - 25433

Residual dose rate measurements were conducted on two Spallation Neutron Source spent structures, target vessel no. 13 and proton beam window no. 5, after extraction from their service locations. These measurements were used to verify calculation methods for radionuclide inventory assessment that are typically performed for nuclear waste characterization and transportation. Neutronics analyses for predicting residual dose rates were carried out using complex and rigorous geometric models of the structures and their surroundings. Calculational results were analyzed and compared to the measured dose rates. (authors)

43 PARTICLE ACCELERATORS↗

The experiment filtering tool in the MACSENS workbench - 14341

The MACSENS (outils Moret d'Aide a la Caracterisation et aux etudes de SENSibilite) workbench is dedicated to the advanced validation work for criticality studies. The aim of this kind of tool is to determine the experiments from a validation database being the 'closest' to an application case and, from there, to evaluate a calculation bias with a related uncertainty. To achieve this goal, the MACSENS workbench relies on different kind of information stored in various databases depending on the origin of the data. Two main kinds of data can be identified. The first one concerns the data used to describe the experiments of the validation database (e.g. the inputs needed to perform a calculation). These values characterize the chemical and geometrical models. They can be considered as constant, as they do not vary once evaluated, and some of them can be from a non-numerical nature (reflector material for example...). The second kind of data gathers the results obtained with the use of a simulation code, such as reaction rates, fluxes and leakages, sensitivities, k{sub eff}, etc. These values depend on the version of the code and are purely numerical. In the early 2000's, regarding the increasing number of experiments evaluated in the ICSBEP handbook, the OECD/NEA (Organization for Economic Co-operation and Development/Nuclear Energy Agency), under the ICSBEP (International Criticality Safety Benchmark Evaluation Project) working group direction, decided to store such information in a database and to provide a software, called DICE (Database for the International Criticality safety benchmark Evaluation project), allowing users to search easily criticality experiments of interest. Up to now, more than 4400 critical or subcritical configurations have been compiled by ICSBEP, described and stored in the DICE database. Over time, a validation work has been done on the data, with the participation of IRSN, and a quality assurance policy has been defined. For these reasons, the DICE database is highly reliable. These features were fundamental for the MACSENS developers, who were looking for a database containing descriptive data of the experiments included in the MORET code validation database. The paper describes the solution chosen by IRSN to take advantage of the DICE database content and to overcome the DICE limits. It also explains the quality assurance policy applied to guaranty the reliability of the stored data. It will also discuss the use of the experiment-filtering module of the MACSENS workbench to select a set of experiments and to examine numerical parameter trends for an application case. (authors)

42 ENGINEERING↗

SCALE 6.2 Continuous-energy Tsunami- 3D capabilities - 14566

The TSUNAMI (Tools for Sensitivity and Uncertainty Analysis Methodology Implementation) capabilities within the SCALE code system make use of sensitivity coefficients for an extensive number of criticality safety applications, such as quantifying the data-induced uncertainty in the eigenvalue of critical systems, assessing the neutronic similarity between different systems, quantifying computational biases, and guiding nuclear data adjustment studies. The need to model geometrically complex systems with improved ease of use and fidelity and the desire to extend TSUNAMI analysis to advanced applications have motivated the development of a SCALE 6.2 module for calculating sensitivity coefficients using three-dimensional (3D) continuous-energy (CE) Monte Carlo methods: CE TSUNAMI-3D. This paper provides an overview of the theory, implementation, and capabilities of the CE TSUNAMI-3D sensitivity analysis methods. CE TSUNAMI contains two methods for calculating sensitivity coefficients in eigenvalue sensitivity applications: (1) the Iterated Fission Probability (IFP) method and (2) the Contribution-Linked eigenvalue sensitivity/Uncertainty estimation via Track length importance Characterization (CLUTCH) method. This work also presents the Generalized Adjoint Response in Monte Carlo method (GEAR-MC), a first-of-its-kind approach for calculating adjoint-weighted, generalized response sensitivity coefficients - such as flux responses or reaction rate ratios - in CE Monte Carlo applications. The accuracy and efficiency of the CE TSUNAMI-3D eigenvalue sensitivity methods are assessed from a user perspective in a companion publication, and the accuracy and features of the CE TSUNAMI-3D GEAR-MC methods are detailed in this paper. (authors)

42 ENGINEERING↗

14-MeV Neutron Generator Used as a Thermal Neutron Source

One of the most important applications of the general purpose Monte Carlo N-Particle (MCNPS and MCNPX) codes is neutron shielding design. We employed this method to simulate the shield of a 14-MeV neutron generator used as a thermal neutron source providing an external thermal neutron beam for testing large area neutron detectors developed for diffraction studies in biology and also useful for national security applications. Nuclear reactors have been the main sources of neutrons used for scientific applications. In the past decade, however, a large number of reactors have been shut down, and the importance of other, smaller devices capable of providing neutrons for research has increased. At Brookhaven National Laboratory a moderated Am-Be neutron source with shielding is used for neutron detector testing. This source is relatively weak, but provides a constant flux of neutrons, even when not in use. The use of a 14 MeV energized neutron generator, with an order of magnitude higher neutron flux has been considered to replace the Am-Be source, but the higher fast neutron yield requires a more careful design of moderator and shielding. In the present paper we describe a proposed shielding configuration based on Monte Carlo calculations, and provide calculated neutron flux and dose distributions. We simulated the neutron flux distribution of our existing Am-Be source surrounded by a paraffin thermalizer cylinder (radius of 17.8 cm), 0.8 mm cadmium, and borated polyethylene as biological shield. The thermal neutrons are available through a large opening through the polyethylene and cadmium. The geometrical model for the MCNPS and MCNPX2 simulations is shown in Fig. 1. We simulated the Am-Be source neutron energy distribution as a point source having an energy distribution of four discrete lines at 3.0 (37%), 5.0 (35%), 8.0 (20%) and 11.0 (8%) MeV energies. The estimated source strength based on the original specifications is 6.6 {center_dot} 10{sup 6} neutrons/sec. The simulation accurately predicts the measured thermal neutron flux at the collimator (Figure 2), thus providing validation for this method. Using MCNPX we simulated the neutron and photon dose distribution and also obtained a good agreement with the measured values. Having established a validated framework for the shield calculation we then scaled up the Am-Be arrangement to simulate the shielding required for the higher neutron energy and flux of the neutron generator (-10{sup 8} neutrodsec at 14 MeV). Given the physical dimensions of the generator we have chosen a cylindrical geometry, where the generator tube is placed vertically into a cylindrical thermalizer (25 cm paraffin) from above. The thermalizer is surrounded by 0.8 mm cadmium, and a cylindrical borated polyethylene shield. A cylindrical opening (radius of 7.6 cm) serves to direct the neutrons out towards the experimental area (on the right side). The initial model is shown in figure 3. The first goal of the calculations was to establish the minimal required radius of the biological shield. For this purpose we performed MCNPX neutron and photon dose distribution calculations by tallying the absorbed dose on a 200 x 200 cm mesh in the vertical center plane superimposed over the geometry. Figure 4. displays the neutron dose distribution along the central horizontal (X) axis. As observed from the figure, a shielding radius of -80 cm is sufficient to obtain a dose level of < -4 mrem/hour outside the shield (except from the open neutron channel on the right). In the next step we studied the optimization of the thickness of the paraffin thermalizer by increasing the depth of the neutron exit channel into the paraffin cylinder. It was found, that the thermal flux greatly increases if we have thinner paraffin layer, an optimal value being about 5 cm thickness. But as a drawback the flux of fast neutrons also increased. A thicker thermalizer layer, in fact, acts as shielding. A slightly off centered, tangential placement of the neutron channel provides a solution which maximizes the thermal flux to fast neutron yield. Figure 5. and 6. display the final results, where we included an outside biological shield (20 cm thickness) providing a shielded experimental area. There is a 10-100 n/cm{sup 2}sec flux near the neutron beam exit, and outside the shield the neutron dose is below the radiation area limit (-5 mrem/hour).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗