Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fringe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

VLBI observations of SS 433 at 3.6 and 13 centimeters

SS 433 was detected and partially resolved at 2290 MHz on baselines with fringe spacings of 1.4, 0.1, and 0.003 arcsec. It was also detected at 8420 MHz on a baseline with a fringe spacing of 0.009 arcsec. Simple models of the source, consistent with the limited data, have elongated structures greater than 0.1 arcsec in size with position angles in 1979 May that were within about 10 deg of the position angle of the apparent bulges of the supernova remnant W50. The data also imply that the source contains a core less than 0.002 arcsec in size with a brightness temperature greater than 10 to the 9th K. The bright core and aligned structures that seem to be present in SS 433 and W50 resemble the structures seen in powerful extragalactic radio sources which are many orders of magnitude larger.

Walker, R. C.↗

Very high resolution observations of SS433 at 10.65 GHz

Observations of SS433 made on June 12, 1979, from West Germany, Massachusetts, and West Virginia are discussed. It is noted that SS433 did not show fringes on any baseline although all the calibration sources were seen at their expected strengths. The measured total flux density of SS433 was found to be approximately 0.5 Jy, consistent with previous observations. The source was observed by on-offs at each telescope, which indicates that they were all pointed properly during the observations. The absence of fringes is not attributed to poor observing conditions or instrumental difficulties. It is concluded that if all the 10.65 GHz radiation emanates from a single component, then that component is at least 0.005 arcsec (approximately 10 to the 14th cm) in size. The measurements made on more sensitive intercontinental baselines indicate that there is no component of SS433 smaller than 0.001 arcsec emitting 10.65 GHz radiation above a level of 50 mJy.

Geldzahler, B. J.↗

Alignment of a two-beam interferometer

Two beam interferometers have been proposed for space applications such as sensing the shape of a large antenna. Since alignment and adjustment of interferometers have long been considered difficult laboratory tasks, the question of making their operation sufficiently automatic for space applications is a serious one. As a first step in addressing this question certain manual procedures, which may not be well known, have been collected from widely scattered sources. These techniques are illustrated by two examples: (1) the alignment of a Mach-Zehnder interferometer and the adjustment of fringe location. (2) The adjustment of a Michelson interferometer for zero path difference (white light fringes).

Tubbs, E. F.↗

Dynamic Moire Methods for Detection of Loosened Space Shuttle Tiles

Moire fringe methods for detecting loose space shuttle tiles were investigated with a test panel consisting of a loose tile surrounded by four securely bonded tiles. The test panel was excited from 20 to 150 Hz with in-plane sinusoidal acceleration of 2 g (peak). If the shuttle orbiter can be subjected to periodic excitation of 1 to 2 g (peak) and rigid-body periodic displacements do not mask the change in the Moire pattern due to tile looseness, then the use of projected Moire fringes to detect out-of-plane rockin appears to be the most viable indicator of tile looseness since no modifications to the tiles are required.

Snow, W. L.↗

Advances in Moire interferometry for thermal response of composites

An experimental technique for the precise measurement of the thermal response of both sides of a laminated composite coupon specimen uses Moire interferometry with fringe multiplication which yields a sensitivity of 833 nm (32.8 micro in.) per fringe. The reference gratings used are virtual gratings and are formed by partially mirrorized glass prisms in close proximity to the specimen. Results are compared with both results obtained from tests which used Moire interferometry on one side of composite laminates, and with those predicted by classical lamination theory. The technique is shown to be capable of producing the sensitivity and accuracy necessary to measure a wide range of thermal responses and to detect small side to side variations in the measured response. Tests were conducted on four laminate configurations of T300/5208 graphite epoxy over a temperature range of 297 K (75 F) to 422 K (300 F). The technique presented allows for the generation of reference gratings for temperature regimes well outside that used in these tests.

Brooks, E. W., Jr.↗

Dual exposure interferometry

The application of dual exposure differential interferometry to gas dynamics and flow visualization is discussed. A differential interferometer with Wallaston prisms can produce two complementary interference fringe systems, depending on the polarization of the incident light. If these two systems are superimposed on a film, with one exposure during a phenomenon, the other before or after, the phenomenon will appear on a uniform background. By regulating the interferometer to infinite fringe distance, a resolution limit of approximately lambda/500 can be obtained in the quantitative analysis of weak phase objects. This method was successfully applied to gas dynamic investigations.

Smeets, G.↗

Development of a simplified optical technique for the simultaneous measurement of particle size distribution and velocity

Existing techniques were surveyed, an experimental procedure was developed, a laboratory test model was fabricated, limited data were recovered for proof of principle, and the relationship between particle size distribution and amplitude measurements was illustrated in an effort to develop a low cost, simplified optical technique for measuring particle size distributions and velocities in fluidized bed combustors and gasifiers. A He-Ne laser illuminated Rochi Rulings (range 10 to 500 lines per inch). Various samples of known particle size distributions were passed through the fringe pattern produced by the rulings. A photomultiplier tube converted light from the fringe volume to an electrical signal which was recorded using an oscilloscope and camera. The signal amplitudes were correlated against the known particle size distributions. The correlation holds true for various samples.

Smith, J. L.↗

Projection moire for remote contour analysis

Remote projection and viewing of moire contours are examined analytically for a system employing separate projection and viewing optics, with specific attention paid to the practical limitations imposed by the optical systems. It is found that planar contours are possible only when the optics are telecentric (exit pupil at infinity) but that the requirement for spatial separability of the contour fringes from extraneous fringes is independent of the specific optics and is a function only of the angle separating the two optic axes. In the nontelecentric case, the contour separation near the object is unchanged from that of the telecentric case, although the contours are distorted into low-eccentricity (near-circular) ellipses. Furthermore, the minimum contour spacing is directly related to the depth of focus through the resolution of the optics.

Doty, J. L.↗

Urban change detection procedures using Landsat digital data

Landsat multispectral scanner data was applied to an urban change detection problem in Denver, CO. A dichotomous key yielding ten stages of residential development at the urban fringe was developed. This heuristic model allowed one to identify certain stages of development which are difficult to detect when performing digital change detection using Landsat data. The stages of development were evaluated in terms of their spectral and derived textural characteristics. Landsat band 5 (0.6-0.7 micron) and texture data produced change detection maps which were approximately 81 percent accurate. Results indicated that the stage of development and the spectral/textural features affect the change in the spectral values used for change detection. These preliminary findings will hopefully prove valuable for improved change detection at the urban fringe.

Jensen, J. R.↗

Very long baseline interferometry at a wavelength of 3.4 mm

The first detection of interference fringes by VLBI at a wavelength of 3.4 mm during observations of 3C84 are reported. The compact source in the nucleus of 3C84 was observed for a 9-hr period on the 485 km baseline between the Owens Valley Radio Observatory and the Hat Creek Observatory. The fringe data are given and the derivation of the correlated flux densities is described. The findings are discused in the context of previous obervations. The results demonstrate that there are no unforeseen technical difficulties associated with millimeter VLBI, and that the sensitivity of existing systems is sufficient to observe objects brighter than a few Jy. The observations are consistent with the millimeter wavelength radio structure of 3C84 being more compact than its centimeter wavelength structure.

Readhead, A. C. S.↗

Exact modeling of lineshape and wavenumber variations for off-axis detectors in Fourier transform spectrometers (FTS) sensor systems

The utilization of detector arrays in the focal planes of FTS sensor systems allows simultaneous spectral and spatial measurements. However, spectral lineshapes and wavenumber locations depend upon the size and location of the detector elements with respect to the Haidinger fringe pattern of the FTS sensor. These spectral distortions can be generalized as a shift and shape change of the FTS sensor lineshape. Depending on the distortions that can be tolerated, a degree of field-widening can be obtained for a given Haidinger fringe pattern. An exact model for predicting the FTS lineshape distortions is presented. The model is applied to several contemporary applications in order to quantify the magnitude of distortions to be expected.

Niple, E.↗

Calibration of diode laser spectra using a confocal etalon

The dual-beam diode laser spectrometer described by Jennings (1980) is adapted to use a 50-cm confocal etalon for frequency calibration. The collimated radiation from the laser is split at a wedged ZnSe window, and the reference beam is then focused at the midpoint of the etalon length. After the etalon, the reference beam is recollimated and continues its regular path to the monochromator and detectors. An aperture is placed before the etalon in order to limit the entrance beam diameter to approximately 5 mm. Both ends of the etalon are furnished with two-axis adjustments. Initial alignment is achieved using an He-Ne laser, and final optimization involves adjustment of the cavity length as well as the etalon pitch and yaw. The 50-cm confocal etalon produces fringes separated by 150 MHz (0.005/cm). With the aid of a CO2 laser, it is found to have fringe widths (FWHM) of 2 MHz. The confocal etalon makes it possible to improve the accuracy of relative frequency measurements in diode laser spectra and to check the spectral purity and stability of the laser during the recording of spectra.

Jennings, D. E.↗

Deformation measurements of composite multi-span beam shear specimens by Moire interferometry

Experimental analyses were performed for determination of in plane deformations and shear strains in unidirectional and quasi-isotropic graphite-epoxy beams. Forty-eight ply beams were subjected to 5 point and 3 point flexure. Whole field measurements were recorded at load levels from about 20% to more than 90% of failure loads. Contour maps of U and W displacement fields were obtained by moire interferometry, using reference gratings of 2400 lines/mm. Clearly defined fringes with fringe orders exceeding 1000 were obtained. Whole field contour maps of shear strains were obtained by a method developed for these tests. Various anomalous effects were detected in the displacement fields. Their analysis indicated excess shear strains in resin rich zones in regions of shear tractions; free edge shear strains in quasi-isotropic specimens in regions of normal stresses; and shear stresses associated with cyclic shear compliances of quasi-isotropic plies in regions of shear tractions. Their contributions could occur independently or in superposition. Qualitative analyses addressed questions of relaxation; influence of contact stress distribution; specimen failure; effect of specimen overhang; nonlinearity; and qualities of 5 and 3 point flexure tests.

Post, D.↗

A comparison of electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry for flow measurements

Electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry are compared as methods for the accurate measurement of refractive index and density change distributions of phase objects. Experimental results are presented to show that the two methods have comparable accuracy for measuring the first derivative of the interferometric fringe shift. The phase object for the measurements is a large crystal of KD*P, whose refractive index distribution can be changed accurately and repeatably for the comparison. Although the refractive index change causes only about one interferometric fringe shift over the entire crystal, the derivative shows considerable detail for the comparison. As electronic phase measurement methods, both methods are very accurate and are intrinsically compatible with computer controlled readout and data processing. Heterodyne moire is relatively inexpensive and has high variable sensitivity. Heterodyne holographic interferometry is better developed, and can be used with poor quality optical access to the experiment.

Decker, A. J.↗

Moire interferometry for deformation and strain studies

Recent advances in high sensitivity more interferometry are described. In-plane displacement fields are shown for very challenging problem areas: adhesive joints in tension and in bending, flexure of quasi-isotropic composite laminates, and fatigue cracks in aluminum. Reference gratings with 2400 lines/mm (60,690 l/in) were used, providing a sensitivity of 0.417 micron/fringe order (16.4 microinch./fringe order). Excellent fringe contrast was obtained in all cases, even for gradients of 64 fringes/mm (1600 fringes/in.). A four-beam optical system to produce two orthogonal virtual reference gratings was employed. The question of unknown relative displacements in two-body problems was answered by use of a soft bridge between the bodies to provide a continous path for the fringe count.

Post, D.↗

Moire deflectometry with deferred electronic heterodyne readout

The electronic heterodyne technique is applied to the task of deferred readout of phase objects' moire fringes. In combination with the heterodyne readout technique, moire deflectometry constitutes a powerful tool for the study of phase objects, exhibiting high sensitivity, ease of automation and recording, low cost, use of incoherent illumination, and independence from fringe contrast variations.

Stricker, J.↗

Finding Brazing Voids by Holography

Vibration-induced interference fringes reveal locations of defects. Holographic apparatus used to view object while vibrated ultrasonically. Interference fringes in hologram reveal brazing defects. Holographic technique locates small voids in large brazed joints. Identifies unbrazed regions 1 in. to second power (6 cm to the second power) or less in area.

Galluccio, R.↗

A tomographic technique for aerodynamics at transonic speeds

Computer aided tomography (CAT) provides a means of noninvasively measuring the air density distribution around an aerodynamic model. This technique is global in that a large portion of the flow field can be measured. A test of the applicability of CAT to transonic velocities was studied. A hemispherical-nose cylinder afterbody model was tested at a Mach number of 0.8 with a new laser holographic interferometer at the 2- by 2-Foot Transonic Wind Tunnel. Holograms of the flow field were taken and were reconstructed into interferograms. The fringe distribution (a measure of the local densities) was digitized for subsequent data reduction. A computer program based on the Fourier-transform technique was developed to convert the fringe distribution into three-dimensional densities around the model. Theoretical aerodynamic densities were calculated for evaluating and assessing the accuracy of the data obtained from the tomographic method.

Lee, G.↗