Control Oriented Model of Cabin-HVAC System in a Long-Haul Trucks for Energy Management Applications

Super Truck II is a 48V mild hybrid class 8 truck with an all auxiliary loads powered purely by the battery pack. Electric Heating Ventilation and Air Conditioning (HVAC) load is the most prominent battery load during the hotel period, when the truck driver is resting inside the sleeper. For the PACCAR Super Truck II (ST-II) project a 48 V battery system provides the required power during the hotel period. A cabin-HVAC model estimates the electric load on the 48V battery system, allowing the control system to implement an efficient energy management strategy that avoids engine idling during the hotel period. The thermal model accounts for the sun load due to the time of day and the geographic location of the truck during the hotel period. The cabin-HVAC model has two parts. First, a grey box model with two heat exchangers (Condenser and Evaporator) working in unison with refrigerant mass flow rate as an input and HVAC load as an output. Second, a two-node cabin model formulated to estimate the cabin temperature as a function of the Global Horizontal Irradiance (GHI), HVAC load and ambient temperature. The models are calibrated using experimental cabin-HVAC system data as for long-haul class 8 truck (e.g. ST-II). Here, the model simulations show that the overall Root Mean Square Error (RMSE) value of 0.4°C between the experimental and simulated cabin temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical Validation of Multi-Zone HVAC System Model: Evaluation of Existing Infiltration Models used in Building Energy Simulation

Infiltration can have a significant impact on building loads. Studies have shown that infiltration can account for 15-40% of annual space conditioning needs in commercial buildings (Emmerich et al. 2019; Younes et al. 2012). The driving force of infiltration is the pressure difference across the building envelope caused by wind, the stack effect (known as buoyancy effect), and the operation of ventilation equipment. Wind pressure is governed by wind direction, speed, building shape, and other structures around the building. The stack effect is a function of the building height and air density differences of ambient air (Han, 2015). The effect of wind is dominant in low-rise residential buildings, and the stack effect is dominant in highrise buildings (ASHRAE 2017). In building energy simulation programs (e.g., EnergyPlus), various empirical infiltration models (e.g., the effective leakage area model, the flow coefficient model) are available to simulate infiltration rates. To help users in selecting a proper infiltration model for modeling of the two-story Flexible Research Platform (FRP), the team evaluates the existing infiltration models in EnergyPlus based on field measurements from the FRP. The blower door and tracer gas decay tests were performed in the FRP. The blower door test result was used to estimate input parameters required in the infiltration models. The actual infiltration rates were estimated with the tracer gas decay test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A conservative, interface-resolved, compressible framework for the modeling and simulation of liquid/gas phase change

This paper presents a method for simulating evaporation in a compressible, interface-resolved framework appropriate for modeling problems of engineering interest. In order to achieve robustness and broad applicability, the method has been designed to discretely enforce consistent mass and thermal energy transport at the phase interface, to globally conserve mass, momentum, and energy, and to be capable of modeling compressible and incompressible systems. Verification is performed via the Sod-shock test, one-dimensional heat conduction, evaporation from a planar interface, and evaporation of three-dimensional droplets. Convergence with increasing mesh resolution is demonstrated in all tested configurations, and conservation is maintained near machine precision for a translating droplet. Conservation and accurate phase change rates are preserved at the low numerical resolutions commonly encountered in engineering calculations. Following verification, the method is validated by comparison to an empirical correlation for evaporating droplets in high temperature crossflow, and the presentation concludes with the simulation of an iso-octane spray at conditions representative of gasoline direct injection. In conclusion, successful verification, validation, and demonstrated practical utility suggest the method to be an accurate, efficient, and robust approach for the study of phase change in engineering systems.

97 MATHEMATICS AND COMPUTING↗

Scaling Energy Efficient Retrofits for Small Commercial Apartment Buildings

With support from the U.S. Department of Energy’s (DOE) Building Technologies Office (BTO), the International Center for Appropriate and Sustainable Technology (ICAST) recently completed a three-year cooperative agreement to scale energy efficiency retrofits (EER) on small multifamily (MF) buildings. ICAST EER strategies ranged from low-hanging “direct install” of measures such as LED lighting, low-flow showerheads and aerators, and smart thermostats to major strategies such as HVAC replacement with high-efficiency boilers or heat pumps. As feasible, some projects also included the addition of renewable energy sources such as photo voltaic (PV) solar. When ICAST began the BTO project, it operated in two states and oversaw EER at approximately 80 MF buildings per year. With assistance from BTO, ICAST has grown significantly and now has staff in six states with MF EER projects in another seven, and performed EER on 956 MF buildings. ). ICAST was able to successfully execute this project by 1) Improving viability and efficiency of its processes, 2) Launching two new services and 3) Creating an affiliate program. For the most part, ICAST focused on a specific type of MF property: naturally occurring affordable housing (NOAH), because it is a significantly underserved market within the hard-to-serve MF market. NOAHs are typically smaller properties (5 to 64 units), owned by small organizations or individual investors looking for positive cash flow. ICAST believes the NOAH market can be successfully served with a one-stop-shop approach that makes it easy, hassle-free, and cost-effective for owners to acquire green upgrades for their property(ies). With the assistance of BTO funding, ICAST successfully used the cited EER methods and strategies to scale-up its OSS approach to service a greater number of MF housing and expand into new geographies. Additionally, support from BTO helped ICAST create self-sustaining programs which will not need to rely on on-going funding.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dual Impacts of Space Heating Electrification and Climate Change Increase Uncertainties in Peak Load Behavior and Grid Capacity Requirements in Texas

Around 60% of households in Texas currently rely on electricity for space heating. As decarbonization efforts increase, non‐electrified households could adopt electric heat pumps, significantly increasing peak (highest) electricity demand in winter. Simultaneously, anthropogenic climate change is expected to increase temperatures, the potential for summer heat waves, and associated electricity demand for cooling. Uncertainty regarding the timing and magnitude of these concurrent changes raises questions about how they will jointly affect the seasonality of peak demand, firm capacity requirements, and grid reliability. This study investigates the net effects of residential space heating electrification and climate change on long‐term demand patterns and load shedding potential, using climate change projections, a predictive load model, and a direct current optimal power flow (DCOPF) model of the Texas grid. Results show that full electrification of residential space heating by replacing existing fossil fuel use with higher efficiency heat pumps could significantly improve reliability under hotter futures. Less efficient heat pumps may result in more severe winter peaking events and increased reliability risks. As heating electrification intensifies, system planners will need to balance the potential for greater resource adequacy risk caused by shifts in seasonal peaking behavior alongside the benefits (improved efficiency and reductions in emissions).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of dissipative baryon current in heavy-ion collisions at RHIC-BES energies

The CLVisc (3+1)D viscous hydrodynamic model is extended to include the equation of net baryon conservation and the Israel-Stewart-like equations for dissipative baryon current. Using the NEOSB equation of state, we simulate the dynamical evolution and collectivity of the quark-gluon plasma with finite chemical potential, assuming smooth energy density and net baryon density distributions at the initial proper time. Numerical results are shown for the impact of net-baryon dissipation on particle yields and p T spectra in heavy-ion collisions at beam energy scan energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental investigation on heat transfer performance of drain water heat recovery heat exchangers

Water heating accounts for 18 % of residential energy consumption, and a substantial portion of this energy can be recovered through drain water heat recovery systems. Here, this paper investigates the heat transfer performance of drain water heat recovery heat exchangers. Two heat exchanger configurations were studied: vertical (gravity film exchanger) and horizontal. The heat recovery performance of the exchangers was quantified using sensible effectiveness and characteristic curves following the ε-NTU approach. Depending on the flow conditions, heat exchangers with a vertical configuration offered higher heat transfer effectiveness compared with the horizontal configuration under similar operating conditions. Furthermore, the results showed that properly designed and sized heat exchangers can effectively recover considerable amounts of waste heat from drains, depending on flow rates. Additionally, in the vertical heat exchanger configuration, low flow rates result in partially wet conditions, resulting in lower heat transfer effectiveness. Therefore, two distributor configurations are proposed to improve the heat transfer performance of vertically configured heat exchangers at low flow rates. The proposed distributor configurations and data presented in this paper will be useful in the design and development of drain water heat recovery systems in building applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

First implementation of gyrokinetic exact linearized Landau collision operator and comparison with models

Gyrokinetic simulations are fundamental to understanding and predicting turbulent transport in magnetically confined fusion plasmas. Previous simulations have used model collision operators with approximate field-particle terms of unknown accuracy and/or have neglected collisional finite Larmor radius (FLR) effects. We have implemented the linearized Fokker–Planck collision operator with exact field-particle terms and full FLR effects in a gyrokinetic code (GENE). The new operator, referred to as “exact” in this paper, allows the accuracy of model collision operators to be assessed. The conservative Landau form is implemented because its symmetry underlies the conservation laws and the H-theorem, and enables numerical methods to preserve this conservation, independent of resolution. The implementation utilizes the finite-volume method recently employed to discretize the Sugama collision model in GENE, allowing direct comparison between the two operators. Results show that the Sugama model appears accurate for the growth rates of trapped electron modes (TEMs) driven only by density gradients, but appreciably underestimates the growth rates as the collisionality and electron temperature gradient increase. The TEM turbulent fluxes near the nonlinear threshold using the exact operator are similar to the Sugama model for the n e = d ln T e /d ln n e = 0 case, but substantially larger than the Sugama model for the n e = 1 case. The FLR effects reduce the growth rates increasingly with wavenumber deepening a “valley” at the intermediate binormal wavenumber as the unstable mode extends from the TEM regime to the electron temperature gradient instability regime. Application to the Hinton–Rosenbluth problem shows that zonal flows decay faster as the radial wavenumber increases and the exact operator yields weaker decay rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cooling Strategies for an Electric Motor with Additively Manufactured Hollow Conductors and Distributed Power Electronics Integrated with Heat Pipes

This paper discusses design tradeoffs and thermal modeling explored in cooling strategies for an aircraft propulsion electric motor with additively manufactured coils and distributed power electronics integrated with heat pipes. Design tradeoffs include heat pipe Qmax performance related to inclination, condenser configuration, coolant type, coolant flow path complexity, and ease of access to modular power electronics. Three cooling strategies were selected and realized into CAD models. These models were further evaluated using 3D thermal FEA and optimization tools to explore cooling geometry details that include fin thickness, spacing and count with the objective to minimize fin mass under a set of constraints. Lastly, motorette test data is presented comparing air versus liquid cooling of heat pipes.

additive manufacturing↗

An Evaluation Framework for State Energy Offices' Energy Efficiency and Clean Energy Workforce Programs

Historic levels of funding for energy efficiency and clean energy projects from the Bipartisan Infrastructure Law and Inflation Reduction Act will be flowing through State Energy Offices (SEOs) in the coming years, including funds specifically for supporting workforce development efforts. This report offers a workforce evaluation framework that they can use to track and measure the progress, performance, and effectiveness of energy efficiency and clean energy workforce programs that they fund and/or implement. This evaluation step is essential to ensuring that SEOs' workforce efforts remain relevant to the evolving needs of the energy efficiency and clean energy sector and advance a workforce that is inclusive and diverse thus maximizing the success of their programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Component and efficient plate and frame absorber

An absorber for an absorption refrigeration system for a vertically mounted plate absorber has fins positioned over the plate to promote distribution of a fluid under flow as a nearly continuous thin film. The absorber has rows of fins that are evenly spaced with the fins occupying a portion of the active width of the plate with adjacent rows offset by the width of the plate. A combined evaporator-absorber module is constructed with the absorbing face of the absorber parallel with an evaporating surface of an evaporator where absorber solution and refrigerant fall as parallel falling sheets of liquid. The absorber is covered with a porous hydrophobic membrane to isolate the falling absorber solution from the falling liquid refrigerant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Characterization of High-Surface Area Thermal Energy Storage

There is growing interest in energy storage technologies due to the expansion of renewable energy sources that are inherently intermittent and the increasing frequency of extreme weather events that disturb the power grid. Power consumption in buildings makes up approximately 76% of all electricity usage on the grid and is primarily used for thermal applications such as space conditioning, hot water, and cooking. This makes thermal energy storage (TES) an ideal solution for many of these applications. Many TES technologies rely on latent energy storage, which utilizes the melting/solidification of phase change materials (PCM) to store energy. Typically, TES designs suffer from low power density due to their low inherent thermal conductivity. This limitation makes the deployment of TES in active applications difficult as the ease of access to energy is essential for effective use. Common routes for improving power density include high thermal conductivity additives or extended features such as fins that increase cost. This study presents an alternative approach to improving performance through increasing the overall surface area to volume ratio of the device, to increase the available area for convection to occur between the working fluid and PCM. In the study a commercial PCM was selected with a transition temperature ideal for space heating applications. The heat exchanger design utilizes a unique application of triply periodic minimal surfaces (TPMS) for macro-encapsulation of the PCM. The use of TPMS for heat exchangers has been growing in interest due to their high-surface area to volume ratios, which were previously unmanufacturable until the development of additive manufacturing. A modular system was designed and manufactured with a stereolithography resin printing system that is then backfilled with PCM. An experiment test set-up is designed to test the charge and discharge performance of the thermal storage using a conditioned air stream. The pressure drop of the design is tested across a variety of flow rates. When compared to existing experimental data within literature, there is excellent agreement based on the Reynolds number at similar hydraulic diameters. Several inlet temperatures are tested at consistent temperature differences from the phase change temperature for both charging and discharging. Additionally, the volumetric flow rate is varied for each temperature set point. It was found that increasing flow rate had diminishing returns in reducing the overall charge time of the TES. The temperature delta from the melting temperature was the primary contributor to the change in average heat flux with limited variation in average heat transfer rate between charging and discharging at similar inlet temperatures and flow rates. The TPMS heat exchanger design has a high air-side pressure drop but it provides high heat transfer rates. This helps maintain a high outlet temperature during discharge, which is important to thermal comfort applications. The design, manufacturing, and experimental characterization of the TES device will be presented as part of this study.

25 ENERGY STORAGE↗

Effects of additively manufactured surface roughness on small diameter plenums with multiple side discharges for high temperature gas turbine blade cooling applications

Combined heat and power (CHP) applications have significant environmental and economic benefits that are consistent with the goals of the U.S. Department of Energy (DOE). One area that is currently being studied includes the potential benefits of CHP turbine operation at higher turbine inlet temperatures. Internal cooling concepts enabled by additive manufacturing (AM) are of primary interest. Here, the effectiveness of internal cooling is hindered by many factors such as velocity distribution of the cooling air to the hot surface considering impingement cooling. To simulate cooling air exiting from a series of orifices for internal cooling in an airfoil, a straight smooth wall tubing with multiple side discharging orifices is used and compared to additively manufactured tubing (Ti6Al4V Grade 23) with orifice size and spacing as well as inner and outer diameters identical to the smooth wall tubing. Similar to flow discharging form perforated pipes, the flow discharged from individual orifices along the tubes in this study is found to be nonuniformly distributed, and the horizontal (axial direction) momentum can be observed from the experimental data. Discharge velocities have been measured with two-dimensional (2D) particle imaging velocimetry (PIV) and single element hot wire anemometry. Numerical analysis has also been conducted to predict the velocity distributions along the orifices in the smooth wall and additive manufacturing (AM) tubing, which are inherited with surface roughness. Numerical and measured results in this study are compared, presented, and discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Abstract for CRADA between Capture6 CORP and NETL

The National Energy Technology Laboratory (NETL) and Capture6 CORP (Participant) will collaborate to refine Capture6’s transformative air contactor design for optimal direct air capture (DAC) under an awarded project from the Department of Energy’s Direct Air Capture Pre-Commercialization Technology Prize. Current cooling tower designs require exponentially more resources as the concentration of CO 2 in the gas phase decreases, resulting in a low conversion rate of carbonates, a large physical footprint, and high evaporation of water, which consequently limits the energy and water benefits that a DAC process can create. Capture6’s innovative tower design AURA (Absorption Unit Reactor for Ambient air) seeks to improve the mass transfer characteristics of legacy cooling towers and reduces total energy demand by: (1) introducing laminar and turbulent flow to increase mass transfer, (2) generating a solvent gradient to improve CO 2 absorption, (3) leveraging venturi and packed towers to increase the surface for the mass-transfer process, (4) adding charged/cool plates to reduce overall water loss in the system, and (5) utilizing surfactant additives to increase mass transfer. The collaboration will facilitate the deployment of technologies that reduce the total energy required and carbon footprint of solvent-based carbon dioxide removal (CDR) technologies. The anticipated results support NETL’s goal of fostering rapid development and commercialization pathways for technologies that remove CO 2 from the atmosphere.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methane liquefaction with an active magnetic regenerative refrigerator

This manuscript reports liquefaction of methane using an active magnetic regenerative refrigerator (AMRR). The AMRR used to cool from 285 K to 135 K has two identical regenerators fabricated with adjacent layers of four ferromagnetic refrigerants, each with sequentially lower Curie temperatures and lesser masses from hot to cold temperatures. The dual multilayer regenerators were assembled in opposition with a single cold region between them. For this set of experiments equal mass of helium gas was pumped through all layers of the regenerators during the two flow steps of the four-step AMR cycle. After successfully reaching 135 K, a compact condensing coil-fin tube heat exchanger (HEX) with a small storage vessel was mounted in the cold region of the dual regenerator assembly to be cooled during the hot-to-cold helium flow from alternatively demagnetized regenerators. The cold HEX was used to cool and liquefy a process stream of methane gas supplied at 295 K and different pressures in different runs. Further, by measuring time to liquefy a known volume of methane at three different pressures, cooling powers of the AMRR as a function of temperature were determined. The resultant data were compared to those predicted by the AMRR performance model. Conclusions from these experiments and suggestions for future work are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

Bio-inspired alula-based winglet design for enhanced heat transfer in high temperature fin-and-tube heat exchangers

Fin-and-tube heat exchangers (FTHEs) are widely used for high-temperature flue-gas heat recovery, but their performance is often limited by wake regions and non-uniform fin-surface temperatures. This study proposes and numerically evaluates four bio-inspired longitudinal vortex generator (VG) configurations in a high-temperature FTHE with flue-gas inlet temperature ∼1230 K: double-delta, curved double-delta, alula, and a new curved-alula geometry. The reference fin is not hydraulically plain; it already incorporates leading-edge separation columns and convex protrusions, so the alula-type winglets are assessed as downstream add-ons acting on a strongly disturbed flow. In a second step, perforations (one, two and three circular holes) are introduced into the curved-alula VGs to further tailor the flow field. Three-dimensional simulations with the Shear Stress Transpor (SST) $k - ω$ model, temperature-dependent flue-gas properties and conjugate conduction are carried out for gas-side Reynolds numbers $Re_g ≈ 8.0$ x $10^2 - 3.6$ x $10^3$ (mass flow rates 0.5 – 2.5 g/s), and the designs are compared in terms of surface heat flux, Nusselt number, friction factor and hydrothermal performance factor (HTPF). For this already-promoted fin, the additional downstream winglets provide moderate, incremental hydrothermal gains. At the highest Reynolds number, the best non-perforated design (curved-alula) increases surface heat flux from 1630.9 to 1794.7 kW/m² (∼ 10 % gain) and the Nusselt number from 227.6 to 242.6 (∼ 7 % gain), while the friction factor rises from 0.26 to about 0.30, yielding HTPF values close to unity (∼ 0.9 – 1.0). Introducing circular perforations into the curved-alula winglets acts mainly as a wake-bleeding refinement: the three-hole configuration provides a heat flux of 1824.7 kW/m² and a pressure drop of 127.9 Pa, with HTPF in the range ∼ 1.03 – 1.14 and a small (∼ 1 – 3 %) improvement over the solid curved-alula design. Flow-field analysis shows that the perforated curved-alula VGs shrink tube-wake regions, thin the thermal boundary layer and homogenize the fin-surface temperature (outlet-gas temperature ∼ 510 – 520 K and fin-surface temperature ∼ 420 – 421 K for the three-hole case). An optimal flue-gas mass flow rate of ∼ 1 g/s ($Re_g ≈ 1.5$ x $10^3$) is identified, beyond which additional heat-transfer gains are offset by rapidly increasing pressure losses. Overall, the results highlight that initial fin geometry and VG placement are as important as VG shape: alula-based winglets are expected to yield larger relative gains on simpler flat-fin layouts or when positioned closer to the fin leading edge and tube

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Supply Chain Energy and Greenhouse Gas Analysis Using the Materials Flows through Industry (MFI) Tool: Examination of Decarbonization Technology Scenarios for the U.S. Glass Manufacturing Sector

Glass manufacturing is a major part of the U.S. economy, and glass products in multiple sectors - flat glass, container glass, and fiberglass - are a part of everyday life. Despite glass manufacturing's long history, there are still many opportunities for glass production to improve in terms of both in overall energy consumption and greenhouse gas (GHG) emission reduction. Scenarios for the flat, container, and fiberglass sectors show the effect that each improvement has on primary energy demand and GHG emissions, starting from an industry baseline that reflects current manufacturing practices. Using the National Renewable Energy Laboratory's Material Flows through Industry tool, multiple scenarios are examined for each glass sector by applying a combination of energy reduction, increased electrification, hydrogen cofiring, a more renewable electric grid, and increased use of cullet. Additional decarbonization options are possible for glass but are left for later analysis due to cost, feasibility, or data issues. Primary energy demand can be reduced by 75%-83% compared to baseline inputs, depending on the sector, and GHG emissions are reduced by 82%-86%. Applying the maximum level of improvements listed here has the potential to save over 300 million GJ and 25 million metric tons of GHGs by 2050.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗