Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

NSTAR Ion Thruster and Breadboard Power Processor Functional Integration Test Results

A 2.3 kW Breadboard Power Processing Unit (BBPPU) was developed as part of the NASA Solar Electric Propulsion Technology Application Readiness (NSTAR) Program. The NSTAR program will deliver an electric propulsion system based on a 30 cm xenon ion thruster to the New Millennium (NM) program for use as the primary propulsion system for the initial NM flight. The final development test for the BBPPU, the Functional Integration Test, was carried out to demonstrate all aspects of BBPPU operation with an Engineering Model Thruster. Test objectives included: (1) demonstration and validation of automated thruster start procedures, (2) demonstration of stable closed loop control of the thruster beam current, (3) successful response and recovery to thruster faults, and (4) successful safing of the system during simulated spacecraft faults. These objectives were met over the specified 80-120 VDC input voltage range and 0.5-2.3 output power capability of the BBPPU. Two minor anomalies were noted in discharge and neutralizer keeper current. These anomalies did not affect the stability of the system and were successfully corrected.

Hamley, John A.↗

Short Circuit Current Contribution for Different Wind Turbine Generator Types

An important aspect of wind power plant (WPP) impact studies is to evaluate the short circuit (SC) current contribution of the plant into the transmission network under different fault conditions. This task can be challenging to protection engineers due to the topology differences between different types of wind turbine generators (WTGs) and the conventional generating units. This paper represents simulation results for short circuit current contribution for different types of WTGs obtained through transient analysis using generic WTG models. The obtained waveforms are analyzed to explain the behavior, such as peak values and rate of decay, of the WTG. The effect of fault types and location, and the effect of the control algorithms of power converters on SC current contribution are investigated. It is shown that the response of the WPP to faults will vary based on the type of the installed WTGs. While in Type 1 and Type 2 WTGs, short circuit current will be determined by the physical characteristics of the induction generator, the contribu-tion of Type 3 and Type 4 WTG will be mostly characterized by the power converters control algorithms which are usually considered proprietary information by the wind turbine manufacturers.

17 WIND ENERGY↗

Fault Management Algorithm Risk Assessment for the NASA Space Launch System

This presentation describes the false positive (FP) and false negative (FN) risk assessment process currently being conducted for the Space Launch System (SLS) Artemis II Fault Management (FM) detection functions. The analysis scope, general assumptions and guide rules, and key modeling concepts were discussed to establish the basis of the risk assessments conducted. Initial analyses indicated a dominance in the total risk by software and firmware failures. This paper presents efforts applied to refine the software risks and the overall impact of implementing those modifications. Current analyses conducted on the detection functions implemented for the SLS Artemis II mission indicate primary risk drivers for the individual FM detection functions are flight software failures, firmware design failures, and hardware Common Cause Failures (CCFs). There still remains issues of how to account for time and redundancy in the software risk estimations.

probability risk analysis↗

Fault Management Algorithm Risk Assessment for the NASA Space Launch System

This paper presents the false positive (FP) and false negative (FN) risk assessment process currently being conducted for the Space Launch System (SLS) Artemis II Fault Management (FM) detection functions. The analysis scope, general assumptions and guide rules, and key modeling concepts were discussed to establish the basis of the risk assessments conducted. Initial analyses indicated a dominance in the total risk by software and firmware failures. This paper presents efforts applied to refine the software risks and the overall impact of implementing those modifications. Current analyses conducted on the detection functions implemented for the SLS Artemis II mission indicate primary risk drivers for the individual FM detection functions are flight software failures, firmware design failures, and hardware Common Cause Failures (CCFs). There still remains issues of how to account for time and redundancy in the software risk estimations.

probability risk analysis↗

Cost-Effective Three-Phase Current Amplifier Interface for Real-time Simulator with Relays in-the-Loop

This paper presents a prototype of a simple and cost-effective design using a high-power monolithic power amplifier that allows the relay in-the-loop connectivity for protection and control applications using a real-time simulator. This low-cost amplifier interface increases the number of protective relays in-the-loop connected with the real-time simulator, expanding the scalability of protection devices that could be tested. The amplifier control design was developed in abc coordinates and utilizes integral and proportional-resonant controllers to provide a good tracking of both the fundamental component as the dc component that might be present during fault conditions. To validate the prototype, the current signals and tripping time of a relay interfaced with the current amplifier were compared against a reference relay connected to the low-voltage interface. Both protective relays were set with a U3 Very Inverse time overcurrent curve. The experimental results exhibited similar behaviors for the breaker currents, validating the amplifier interface prototype.

Ferrari Maglia, Max↗

Fault Management Techniques in Human Spaceflight Operations

This paper discusses human spaceflight fault management operations. Fault detection and response capabilities available in current US human spaceflight programs Space Shuttle and International Space Station are described while emphasizing system design impacts on operational techniques and constraints. Preflight and inflight processes along with products used to anticipate, mitigate and respond to failures are introduced. Examples of operational products used to support failure responses are presented. Possible improvements in the state of the art, as well as prioritization and success criteria for their implementation are proposed. This paper describes how the architecture of a command and control system impacts operations in areas such as the required fault response times, automated vs. manual fault responses, use of workarounds, etc. The architecture includes the use of redundancy at the system and software function level, software capabilities, use of intelligent or autonomous systems, number and severity of software defects, etc. This in turn drives which Caution and Warning (C&W) events should be annunciated, C&W event classification, operator display designs, crew training, flight control team training, and procedure development. Other factors impacting operations are the complexity of a system, skills needed to understand and operate a system, and the use of commonality vs. optimized solutions for software and responses. Fault detection, annunciation, safing responses, and recovery capabilities are explored using real examples to uncover underlying philosophies and constraints. These factors directly impact operations in that the crew and flight control team need to understand what happened, why it happened, what the system is doing, and what, if any, corrective actions they need to perform. If a fault results in multiple C&W events, or if several faults occur simultaneously, the root cause(s) of the fault(s), as well as their vehicle-wide impacts, must be determined in order to maintain situational awareness. This allows both automated and manual recovery operations to focus on the real cause of the fault(s). An appropriate balance must be struck between correcting the root cause failure and addressing the impacts of that fault on other vehicle components. Lastly, this paper presents a strategy for using lessons learned to improve the software, displays, and procedures in addition to determining what is a candidate for automation. Enabling technologies and techniques are identified to promote system evolution from one that requires manual fault responses to one that uses automation and autonomy where they are most effective. These considerations include the value in correcting software defects in a timely manner, automation of repetitive tasks, making time critical responses autonomous, etc. The paper recommends the appropriate use of intelligent systems to determine the root causes of faults and correctly identify separate unrelated faults.

O'Hagan, Brian↗

Stacking Faults Originating from Star-Defects in 4H-SiC

Intense efforts are currently in progress to study various sources of basal plane dislocations (BPDs) in SiC epitaxial layers. BPDs can generate Shockley-type stacking faults (SSFs) in SiC epitaxial layers, which have been shown to be associated with the degradation of power devices. This study shows that the star-shaped defect can be a source of several BPDs in the epitaxial layer. We investigate the complex microstructure of the star defect, the generation of BPDs, and expansion of SSFs using various complementary microscopy and optical techniques. We show direct evidence that star-defects can be a nucleation point of single-SSFs that can expand at the core of the defect. Newly found secondary dislocation arrays extending over a few centimeters away are found to be emanating from the primary arms of the star defect. The presence of such dislocation walls and the expansion of single-SSFs will affect the yield of numerous die on a wafer. Further understanding of the formation mechanism of stacking faults generated from star-defects as provided in this study helps understand their effect on SiC-based devices, which is crucial to assess device reliability.

36 MATERIALS SCIENCE↗

Development of a Converter-Based Transmission Line Emulator with Three-Phase Short-Circuit Fault Emulation Capability

A transmission line emulator has been developed to flexibly represent interconnected ac lines under normal operating conditions in a voltage source converter (VSC)-based power system emulation platform. As the most serious short-circuit fault condition, the three-phase short-circuit fault emulation is essential for power system studies. Here, this paper proposes a model to realize a three-phase short-circuit fault emulation at different locations along a single transmission line or one of several parallel-connected transmission lines. At the same time, a combination method is proposed to eliminate the undesired transients caused by the current reference step changes while switching between the fault state and the normal state. Experiment results verify the developed transmission line three-phase short-circuit fault emulation capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decision system and method for separating faults from attacks

According to some embodiments, a plurality of monitoring nodes may each generate a series of current monitoring node values over time that represent a current operation of the industrial asset. A node classification computer may determine, for each monitoring node, a classification result indicating whether each monitoring node is in a normal or abnormal state. A disambiguation engine may receive the classification results from the node classification computer and associate a Hidden Markov Model (“HMM”) with each monitoring node. For each node in an abnormal state, the disambiguation engine may execute the HMM associated with that monitoring node to determine a disambiguation result indicating if the abnormal state is a result of an attack or a fault and output a current status of each monitoring node based on the associated classification result and the disambiguation result.

Giani, Annarita↗

NASA ground terminal communication equipment automated fault isolation expert systems

The prototype expert systems are described that diagnose the Distribution and Switching System I and II (DSS1 and DSS2), Statistical Multiplexers (SM), and Multiplexer and Demultiplexer systems (MDM) at the NASA Ground Terminal (NGT). A system level fault isolation expert system monitors the activities of a selected data stream, verifies that the fault exists in the NGT and identifies the faulty equipment. Equipment level fault isolation expert systems are invoked to isolate the fault to a Line Replaceable Unit (LRU) level. Input and sometimes output data stream activities for the equipment are available. The system level fault isolation expert system compares the equipment input and output status for a data stream and performs loopback tests (if necessary) to isolate the faulty equipment. The equipment level fault isolation system utilizes the process of elimination and/or the maintenance personnel's fault isolation experience stored in its knowledge base. The DSS1, DSS2 and SM fault isolation systems, using the knowledge of the current equipment configuration and the equipment circuitry issues a set of test connections according to the predefined rules. The faulty component or board can be identified by the expert system by analyzing the test results. The MDM fault isolation system correlates the failure symptoms with the faulty component based on maintenance personnel experience. The faulty component can be determined by knowing the failure symptoms. The DSS1, DSS2, SM, and MDM equipment simulators are implemented in PASCAL. The DSS1 fault isolation expert system was converted to C language from VP-Expert and integrated into the NGT automation software for offline switch diagnoses. Potentially, the NGT fault isolation algorithms can be used for the DSS1, SM, amd MDM located at Goddard Space Flight Center (GSFC).

Tang, Y. K.↗

Soft Computing Application in Fault Detection of Induction Motor

The paper investigates the effectiveness of different patter classifier like Feed Forward Back Propagation (FFBPN), Radial Basis Function (RBF) and Support Vector Machine (SVM) for detection of bearing faults in Induction Motor. The steady state motor current with Park's Transformation has been used for discrimination of inner race and outer race bearing defects. The RBF neural network shows very encouraging results for multi-class classification problems and is hoped to set up a base for incipient fault detection of induction motor. SVM is also found to be a very good fault classifier which is highly competitive with RBF.

99 GENERAL AND MISCELLANEOUS↗

Soft-Fault Detection Technologies Developed for Electrical Power Systems

The NASA Glenn Research Center, partner universities, and defense contractors are working to develop intelligent power management and distribution (PMAD) technologies for future spacecraft and launch vehicles. The goals are to provide higher performance (efficiency, transient response, and stability), higher fault tolerance, and higher reliability through the application of digital control and communication technologies. It is also expected that these technologies will eventually reduce the design, development, manufacturing, and integration costs for large, electrical power systems for space vehicles. The main focus of this research has been to incorporate digital control, communications, and intelligent algorithms into power electronic devices such as direct-current to direct-current (dc-dc) converters and protective switchgear. These technologies, in turn, will enable revolutionary changes in the way electrical power systems are designed, developed, configured, and integrated in aerospace vehicles and satellites. Initial successes in integrating modern, digital controllers have proven that transient response performance can be improved using advanced nonlinear control algorithms. One technology being developed includes the detection of "soft faults," those not typically covered by current systems in use today. Soft faults include arcing faults, corona discharge faults, and undetected leakage currents. Using digital control and advanced signal analysis algorithms, we have shown that it is possible to reliably detect arcing faults in high-voltage dc power distribution systems (see the preceding photograph). Another research effort has shown that low-level leakage faults and cable degradation can be detected by analyzing power system parameters over time. This additional fault detection capability will result in higher reliability for long-lived power systems such as reusable launch vehicles and space exploration missions.

Button, Robert M.↗

Health Monitoring of a Planetary Rover Using Hybrid Particle Petri Nets

This paper focuses on the application of a Petri Net-based diagnosis method on a planetary rover prototype.The diagnosis is performed by using a model-based method in the context of health management of hybrid systems.In system health management, the diagnosis task aims at determining the current health state of a system and the fault occurrences that lead to this state. The Hybrid Particle Petri Nets (HPPN) formalism is used to model hybrid systems behavior and degradation, and to define the generation of diagnosers to monitor the health states of such systems under uncertainty. At any time, the HPPN-based diagnoser provides the current diagnosis represented by a distribution of beliefs over the health states. The health monitoring methodology is demonstrated on the K11 rover. A hybrid model of the K11 is proposed and experimental results show that the approach is robust to real system data and constraints.

health monitoring↗

Robust Disturbance Rejection Rotor Current Control of Doubly-Fed Induction Generators

This article proposes a robust transient disturbance rejection current controller (TDRCC) to improve the transient performance of doubly-fed induction generators (DFIGs) in wind turbines during grid disturbances, such as short circuits. Here, the proposed robust TDRCC replaces the proportional-integral-derivative (PID) current controllers conventionally used in the vector control scheme of the DFIG rotor side converter (RSC). The TDRCC estimates the transient disturbances caused by grid faults or other external disturbances and provides compensation to the DFIG rotor voltage in the current control loops of the RSC to improve the robustness of the controller to disturbance. A sliding-mode current controller (SMCC) is also designed to highlight the transient performance improvement of the DFIG using the TDRCC over the state-of-the-art control methods during grid short circuit faults. Simulation studies are conducted in PSCAD/EMTDC for a 3.6-MW DFIG wind turbine with the proposed TDRCC, the conventional PI controller, and the SMCC, respectively during the most severe balanced three-phase grid short circuit fault specified by the U.S. grid code as well as an unbalance single-phase grid short circuit fault. Hardware experiments are conducted on a 200-W DFIG wind turbine emulator with the three different controllers for the same three-phase short circuit fault. Simulation and hardware experiment results show that the TDRCC reduces the peak rotor current significantly when compared with the PI and SMCC controlled DFIG system and, therefore, would help prolong the lifespan of the DFIG's power electronics and reduce maintenance costs.

42 ENGINEERING↗

Automatic Detection of Electric Power Troubles (ADEPT)

ADEPT is an expert system that integrates knowledge from three different suppliers to offer an advanced fault-detection system, and is designed for two modes of operation: real-time fault isolation and simulated modeling. Real time fault isolation of components is accomplished on a power system breadboard through the Fault Isolation Expert System (FIES II) interface with a rule system developed in-house. Faults are quickly detected and displayed and the rules and chain of reasoning optionally provided on a Laser printer. This system consists of a simulated Space Station power module using direct-current power supplies for Solar arrays on three power busses. For tests of the system's ability to locate faults inserted via switches, loads are configured by an INTEL microcomputer and the Symbolics artificial intelligence development system. As these loads are resistive in nature, Ohm's Law is used as the basis for rules by which faults are located. The three-bus system can correct faults automatically where there is a surplus of power available on any of the three busses. Techniques developed and used can be applied readily to other control systems requiring rapid intelligent decisions. Simulated modelling, used for theoretical studies, is implemented using a modified version of Kennedy Space Center's KATE (Knowledge-Based Automatic Test Equipment), FIES II windowing, and an ADEPT knowledge base. A load scheduler and a fault recovery system are currently under development to support both modes of operation.

Wang, Caroline↗

Firmware Architecture of the ARMADAS Bolting Robot

The Automated Reconfigurable Mission Adaptive Digital Assembly Systems (ARMADAS) project, under development at NASA Ames Research Center, has demonstrated on-ground autonomous robotic assembly of extensive digital structures, and it is now moving forward towards in-space demonstration. The ARMADAS system comprises of the operation software, the operation user interface (opsUI), and a swarm of robots. The robotic system consists of a multitude of collaborative agents specifically designed to transport, place and bolt the building blocks, called voxels (volumetric pixels). This paper focuses on the bolting robot, referred to as Mobile Metamaterial Internal Co-Integrator (MMIC-I). MMIC-I is a battery-powered crawling robot. It navigates the structure through extension, contraction and gripping. Two distinct controller boards operate the robot's two symmetric modules, referred to as module A and B. Board A is the master board: it coordinates motion planning and motion primitives execution, hosts the WiFi client, performs periodic self-assessment and system idle check and triggers faults if anomalies are detected. Board B periodically sends a heartbeat to board A, through a wired communication channel that uses the Serial protocol. Additionally, board A's WiFi client receives heartbeat packet requests or motion/bolting commands from a dedicated server board, and acknowledges reception sending back a response heartbeat packet containing information about the overall robot status, e. g. electrical current and voltage values, target and actual angles, operating mode, fault status. Whenever a motion command is sent, the motion planning section of the firmware determines the current robot configuration, using Inertial Measurement Unit readings and the motors Pulse Width Modulation values. Afterwards, it calculates the list of primitives needed to reach the target state, and controls their execution in the proper order. MMIC-I can receive and execute motion and bolting commands only when it is in operational mode. MMIC-I has three operating modes: standby, operational and safed. Standby mode is automatically entered upon startup. While in standby mode, all motors are powered off, and the only accepted commands are the ones relative to a change of mode and heartbeat packet request. Fault detection causes the robot to automatically enter safed or standby mode. Whenever the detected fault occurs within a motion and requires immediate intervention, e. g. an over-current situation, the robot enters safed mode. Safed mode powers off all motors except for the locomotion module, thus preventing the robot from collapsing. Conversely, when the detected fault doesn't require immediate intervention (low battery warning, for instance), the robot enters standby mode after completing the ongoing motion. This paper provides a detailed discussion of MMIC-I's firmware architecture. It accurately describes the implementation approach for each module: sensor data reading, motor control and actuation, WiFi server-client communication, intra-boards Serial communication, operating modes and autonomous fault detection, motion planning, coordination and execution, etc. Moreover, in support of the software description, this paper includes a thorough characterization of MMIC-I's hardware and avionics.

In-space assembly↗

Novel Fault Location Method for Power Systems Based on Attention Mechanism and Double Structure GRU Neural Network

Fault location is one of the most essential techniques to maintain the stable operation of power systems. A fast and accurate fault location allows operators to restore power grids faster and avoid economic losses. Conventional methods rely on expert knowledge to extract the necessary features (e.g. DWT, DFT). For large systems, more coupling effects of transmission lines require more complex feature engineering, and incomplete features can easily introduce large errors. To overcome this, a deep learning approach without manual feature extraction is introduced to the fault location model under big data application. Towards this end, in the proposed method, the attention mechanism, the Bi-GRU and a dual structure network are applied to analyze the current data from different perspectives. Complete information for the fault features is extracted for the fault location. Based on a time series model and benefit from the ability to internally acquire the information architecture of faulty line, the established model is adaptive to the power grids with very complex topologies. Simulation results indicate that the proposed double-structure model reduces the maximum error and is less affected by noise. In comparison with different structures and different models, the proposed method shows better performance in IEEE 39-bus system.

42 ENGINEERING↗

Detecting faults in wind turbines

A wind turbine generator fault detection method is described. The method includes acquiring current data from a wind turbine generator during operation, determining frequency demodulated signals and amplitude demodulated signals by frequency demodulating and amplitude demodulating the current data, resampling the frequency and amplitude demodulated signals corresponding to the current data, monitoring a frequency spectra of the resampled frequency and amplitude demodulated signals corresponding to the current data to identify one or more excitations in the frequency spectra. In response to identifying one or more excitations in the frequency spectra at one or more of the variable fault characteristic frequencies, the method includes generating and transmitting an alert that indicates that a wind turbine generator fault is detected.

17 WIND ENERGY↗