Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

A renormalization group approach to the stick-slip behavior of faults

A fault which is treated as an array of asperities with a perscribed statistical distribution of strengths is described. For a linear array the stress is transferred to a single adjacent asperity and for a two dimensional array to three adjacent asperities. It is shown that the solutions bifurcate at a critical applied stress. At stresses less than the critical stress virtually no asperities fail on a large scale and the fault is locked. At the critical stress the solution bifurcates and asperity failure cascades away from the nucleus of failure. It is found that the stick slip behavior of most faults can be attributed to the distribution of asperities on the fault. The observation of stick slip behavior on faults rather than stable sliding, why the observed level of seismicity on a locked fault is very small, and why the stress on a fault is less than that predicted by a standard value of the coefficient of friction are outlined.

Smalley, R. F., Jr.↗

Dislocation model for aseismic fault slip in the transverse ranges of Southern California

Geodetic data at a plate boundary can reveal the pattern of subsurface displacements that accompany plate motion. These displacements are modelled as the sum of rigid block motion and the elastic effects of frictional interaction between blocks. The frictional interactions are represented by uniform dislocation on each of several rectangular fault patches. The block velocities and fault parameters are then estimated from geodetic data. Bayesian inversion procedure employs prior estimates based on geological and seismological data. The method is applied to the Transverse Ranges, using prior geological and seismological data and geodetic data from the USGS trilateration networks. Geodetic data imply a displacement rate of about 20 mm/yr across the San Andreas Fault, while the geologic estimates exceed 30 mm/yr. The prior model and the final estimates both imply about 10 mm/yr crustal shortening normal to the trend of the San Andreas Fault. Aseismic fault motion is a major contributor to plate motion. The geodetic data can help to identify faults that are suffering rapid stress accumulation; in the Transverse Ranges those faults are the San Andreas and the Santa Susana.

Cheng, A.↗

A preliminary transient-fault experiment on the SIFT computer system

This paper presents the results of a preliminary experiment to study the effectiveness of a fault-tolerant system's ability to handle transient faults. The primary goal of the experiment was to develop the techniques to measure the parameters needed for a reliability analysis of the SIFT computer system which includes th effects of transient faults. A key aspect of such an analysis is the determination of the effectiveness of the operating system's ability to discriminate between transient and permanent faults. A detailed description of the preliminary transient fault experiment along with the results from 297 transient fault injections are given. Although not enough data was obtained to draw statistically significant conclusions, the foundation has been laid for a large-scale transient fault experiment.

Butler, Ricky W.↗

Hardware fault insertion and instrumentation system: Mechanization and validation

Automated test capability for extensive low-level hardware fault insertion testing is developed. The test capability is used to calibrate fault detection coverage and associated latency times as relevant to projecting overall system reliability. Described are modifications made to the NASA Ames Reconfigurable Flight Control System (RDFCS) Facility to fully automate the total test loop involving the Draper Laboratories' Fault Injector Unit. The automated capability provided included the application of sequences of simulated low-level hardware faults, the precise measurement of fault latency times, the identification of fault symptoms, and bulk storage of test case results. A PDP-11/60 served as a test coordinator, and a PDP-11/04 as an instrumentation device. The fault injector was controlled by applications test software in the PDP-11/60, rather than by manual commands from a terminal keyboard. The time base was especially developed for this application to use a variety of signal sources in the system simulator.

Benson, J. W.↗

Design and validation of fault-tolerant flight systems

Flight systems must be validated to show that they are consistent with the requirements of their intended applications. While high reliability is difficult to validate, the additional complexity of fault tolerance further compounds the validation problem. The objective of NASA’s research is to develop a methodology for designing validatable fault-tolerant systems. Under the design-for-validation philosophy, emphasis is placed on developing validation methods that can be incorporated into the design process right from the start and design methods and guidance which, while incorporating fault tolerance, can assure validatability. This paper examines the statistical issues of validating highly reliable, fault tolerant system. There are many problems associated with traditional methods of designing and validating these potentially complex hardware and software systems. Useful design-for-validation methods, which include structured specification and design methodologies, mathematical proof techniques, analytical modeling, simulation and emulation, and physical testing, are discussed. Important design issues associated with fault tolerance are presented along with the related validation concerns which must be addressed. Experience has shown that synchronization and Byzantine resilience must accompany fault tolerance. Other design attributes associated with fault tolerance may be used by a designer on the basis of cost, weight, performance, and validation considerations.

Computer systems↗

An autonomous fault detection, isolation, and recovery system for a 20-kHz electric power distribution test bed

Future space explorations will require long term human presence in space. Space environments that provide working and living quarters for manned missions are becoming increasingly larger and more sophisticated. Monitor and control of the space environment subsystems by expert system software, which emulate human reasoning processes, could maintain the health of the subsystems and help reduce the human workload. The autonomous power expert (APEX) system was developed to emulate a human expert's reasoning processes used to diagnose fault conditions in the domain of space power distribution. APEX is a fault detection, isolation, and recovery (FDIR) system, capable of autonomous monitoring and control of the power distribution system. APEX consists of a knowledge base, a data base, an inference engine, and various support and interface software. APEX provides the user with an easy-to-use interactive interface. When a fault is detected, APEX will inform the user of the detection. The user can direct APEX to isolate the probable cause of the fault. Once a fault has been isolated, the user can ask APEX to justify its fault isolation and to recommend actions to correct the fault. APEX implementation and capabilities are discussed.

Quinn, Todd M.↗

Delivery and application of precise timing for a traveling wave powerline fault locator system

The Bonneville Power Administration (BPA) has successfully operated an in-house developed powerline fault locator system since 1986. The BPA fault locator system consists of remotes installed at cardinal power transmission line system nodes and a central master which polls the remotes for traveling wave time-of-arrival data. A power line fault produces a fast rise-time traveling wave which emanates from the fault point and propagates throughout the power grid. The remotes time-tag the traveling wave leading edge as it passes through the power system cardinal substation nodes. A synchronizing pulse transmitted via the BPA analog microwave system on a wideband channel sychronizes the time-tagging counters in the remote units to a different accuracy of better than one microsecond. The remote units correct the raw time tags for synchronizing pulse propagation delay and return these corrected values to the fault locator master. The master then calculates the power system disturbance source using the collected time tags. The system design objective is a fault location accuracy of 300 meters. BPA's fault locator system operation, error producing phenomena, and method of distributing precise timing are described.

Street, Michael A.↗

A verified design of a fault-tolerant clock synchronization circuit: Preliminary investigations

Schneider demonstrates that many fault tolerant clock synchronization algorithms can be represented as refinements of a single proven correct paradigm. Shankar provides mechanical proof that Schneider's schema achieves Byzantine fault tolerant clock synchronization provided that 11 constraints are satisfied. Some of the constraints are assumptions about physical properties of the system and cannot be established formally. Proofs are given that the fault tolerant midpoint convergence function satisfies three of the constraints. A hardware design is presented, implementing the fault tolerant midpoint function, which is shown to satisfy the remaining constraints. The synchronization circuit will recover completely from transient faults provided the maximum fault assumption is not violated. The initialization protocol for the circuit also provides a recovery mechanism from total system failure caused by correlated transient faults.

Miner, Paul S.↗

Parallel fault-tolerant robot control

A shared memory multiprocessor architecture is used to develop a parallel fault-tolerant robot controller. Several versions of the robot controller are developed and compared. A robot simulation is also developed for control observation. Comparison of a serial version of the controller and a parallel version without fault tolerance showed the speedup possible with the coarse-grained parallelism currently employed. The performance degradation due to the addition of processor fault tolerance was demonstrated by comparison of these controllers with their fault-tolerant versions. Comparison of the more fault-tolerant controller with the lower-level fault-tolerant controller showed how varying the amount of redundant data affects performance. The results demonstrate the trade-off between speed performance and processor fault tolerance.

Hamilton, D. L.↗

A formally verified algorithm for interactive consistency under a hybrid fault model

Consistent distribution of single-source data to replicated computing channels is a fundamental problem in fault-tolerant system design. The 'Oral Messages' (OM) algorithm solves this problem of Interactive Consistency (Byzantine Agreement) assuming that all faults are worst-cass. Thambidurai and Park introduced a 'hybrid' fault model that distinguished three fault modes: asymmetric (Byzantine), symmetric, and benign; they also exhibited, along with an informal 'proof of correctness', a modified version of OM. Unfortunately, their algorithm is flawed. The discipline of mechanically checked formal verification eventually enabled us to develop a correct algorithm for Interactive Consistency under the hybrid fault model. This algorithm withstands $a$ asymmetric, $s$ symmetric, and $b$ benign faults simultaneously, using $m+1$ rounds, provided $n is greater than 2a + 2s + b + m$, and $m\geg a$. We present this algorithm, discuss its subtle points, and describe its formal specification and verification in PVS. We argue that formal verification systems such as PVS are now sufficiently effective that their application to fault-tolerance algorithms should be considered routine.

Lincoln, Patrick↗

Multiple Fault Isolation in Redundant Systems

We consider the problem of sequencing tests to isolate multiple faults in redundant (fault-tolerant) systems with minimum expected testing cost (time). It can be shown that single faults and minimal faults, i.e., minimum number of failures with a failure signature different from the union of failure signatures of individual failures, together with their failure signatures, constitute the necessary information for fault diagnosis in redundant systems. In this paper, we develop an algorithm to find all the minimal faults and their failure signatures. Then, we extend the Sure diagnostic strategies [1] of our previous work to diagnose multiple faults in redundant systems. The proposed algorithms and strategies are illustrated using several examples.

Shakeri, M.↗

Robust Fault Detection for Aircraft Using Mixed Structured Singular Value Theory and Fuzzy Logic

The purpose of fault detection is to identify when a fault or failure has occurred in a system such as an aircraft or expendable launch vehicle. The faults may occur in sensors, actuators, structural components, etc. One of the primary approaches to model-based fault detection relies on analytical redundancy. That is the output of a computer-based model (actually a state estimator) is compared with the sensor measurements of the actual system to determine when a fault has occurred. Unfortunately, the state estimator is based on an idealized mathematical description of the underlying plant that is never totally accurate. As a result of these modeling errors, false alarms can occur. This research uses mixed structured singular value theory, a relatively recent and powerful robustness analysis tool, to develop robust estimators and demonstrates the use of these estimators in fault detection. To allow qualitative human experience to be effectively incorporated into the detection process fuzzy logic is used to predict the seriousness of the fault that has occurred.

Collins, Emmanuel G.↗

Robust Fault Detection

This research used mixed structured singular value theory to develop new estimator (or observer) based approaches to fault detection for dynamic systems. The initial developments were based on minimizing the H-infinity, I-1 and H2 system norms. The resultant fault detection algorithms were each shown to be successful, but the fault detection algorithm based on the I-1 norm was best able to detect abrupt faults. This latter technique was further improved by using fuzzy logic for the fault evaluation. Based on an anomaly observed in this research and apparently ignored in the literature, current research focuses on the determination of a fault using a norm of the change in the residual (the difference between the output of the system and observer) and not simply a norm of the residual itself. This research may lead to a fundamental contribution to research in fault detection and isolation.

Guo, Ten-Huei↗

Application of a Bank of Kalman Filters for Aircraft Engine Fault Diagnostics

In this paper, a bank of Kalman filters is applied to aircraft gas turbine engine sensor and actuator fault detection and isolation (FDI) in conjunction with the detection of component faults. This approach uses multiple Kalman filters, each of which is designed for detecting a specific sensor or actuator fault. In the event that a fault does occur, all filters except the one using the correct hypothesis will produce large estimation errors, thereby isolating the specific fault. In the meantime, a set of parameters that indicate engine component performance is estimated for the detection of abrupt degradation. The proposed FDI approach is applied to a nonlinear engine simulation at nominal and aged conditions, and the evaluation results for various engine faults at cruise operating conditions are given. The ability of the proposed approach to reliably detect and isolate sensor and actuator faults is demonstrated.

Kobayashi, Takahisa↗

Secondary Fracturing of Europa's Crust in Response to Combined Slip and Dilation Along Strike-Slip Faults

A commonly observed feature in faulted terrestrial rocks is the occurrence of secondary fractures alongside faults. Depending on exact morphology, such fractures have been termed tail cracks, wing cracks, kinks, or horsetail fractures, and typically form at the tip of a slipping fault or around small jogs or steps along a fault surface. The location and orientation of secondary fracturing with respect to the fault plane or the fault tip can be used to determine if fault motion is left-lateral or right-lateral.

Kattenhorn, S. A.↗

Parameter Transient Behavior Analysis on Fault Tolerant Control System

In a fault tolerant control (FTC) system, a parameter varying FTC law is reconfigured based on fault parameters estimated by fault detection and isolation (FDI) modules. FDI modules require some time to detect fault occurrences in aero-vehicle dynamics. This paper illustrates analysis of a FTC system based on estimated fault parameter transient behavior which may include false fault detections during a short time interval. Using Lyapunov function analysis, the upper bound of an induced-L2 norm of the FTC system performance is calculated as a function of a fault detection time and the exponential decay rate of the Lyapunov function.

Belcastro, Christine↗

Immunity-Based Aircraft Fault Detection System

In the study reported in this paper, we have developed and applied an Artificial Immune System (AIS) algorithm for aircraft fault detection, as an extension to a previous work on intelligent flight control (IFC). Though the prior studies had established the benefits of IFC, one area of weakness that needed to be strengthened was the control dead band induced by commanding a failed surface. Since the IFC approach uses fault accommodation with no detection, the dead band, although it reduces over time due to learning, is present and causes degradation in handling qualities. If the failure can be identified, this dead band can be further A ed to ensure rapid fault accommodation and better handling qualities. The paper describes the application of an immunity-based approach that can detect a broad spectrum of known and unforeseen failures. The approach incorporates the knowledge of the normal operational behavior of the aircraft from sensory data, and probabilistically generates a set of pattern detectors that can detect any abnormalities (including faults) in the behavior pattern indicating unsafe in-flight operation. We developed a tool called MILD (Multi-level Immune Learning Detection) based on a real-valued negative selection algorithm that can generate a small number of specialized detectors (as signatures of known failure conditions) and a larger set of generalized detectors for unknown (or possible) fault conditions. Once the fault is detected and identified, an adaptive control system would use this detection information to stabilize the aircraft by utilizing available resources (control surfaces). We experimented with data sets collected under normal and various simulated failure conditions using a piloted motion-base simulation facility. The reported results are from a collection of test cases that reflect the performance of the proposed immunity-based fault detection algorithm.

Dasgupta, D.↗

Arc burst pattern analysis fault detection system

A method and apparatus are provided for detecting an arcing fault on a power line carrying a load current. Parameters indicative of power flow and possible fault events on the line, such as voltage and load current, are monitored and analyzed for an arc burst pattern exhibited by arcing faults in a power system. These arcing faults are detected by identifying bursts of each half-cycle of the fundamental current. Bursts occurring at or near a voltage peak indicate arcing on that phase. Once a faulted phase line is identified, a comparison of the current and voltage reveals whether the fault is located in a downstream direction of power flow toward customers, or upstream toward a generation station. If the fault is located downstream, the line is de-energized, and if located upstream, the line may remain energized to prevent unnecessary power outages.

Russell, B. Don↗