Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error vector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Crystal structure representations for machine learning models of formation energies

Here we introduce and evaluate a set of feature vector representations of crystal structures for machine learning (ML) models of formation energies of solids. ML models of atomization energies of organic molecules have been successful using a Coulomb matrix representation of the molecule. We consider three ways to generalize such representations to periodic systems: (i) a matrix where each element is related to the Ewald sum of the electrostatic interaction between two different atoms in the unit cell repeated over the lattice; (ii) an extended Coulomb-like matrix that takes into account a number of neighboring unit cells; and (iii) an ansatz that mimics the periodicity and the basic features of the elements in the Ewald sum matrix using a sine function of the crystal coordinates of the atoms. The representations are compared for a Laplacian kernel with Manhattan norm, trained to reproduce formation energies using a dataset of 3938 crystal structures obtained from the Materials Project. For training sets consisting of 3000 crystals, the generalization error in predicting formation energies of new structures corresponds to (i) 0.49, (ii) 0.64, and (iii) urn:x-wiley:00207608:media:qua24917:qua24917-math-0001 for the respective representations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

J-PLUS: Support vector regression to measure stellar parameters

Stellar parameters are among the most important characteristics in studies of stars which, in traditional methods, are based on atmosphere models. However, time, cost, and brightness limits restrain the efficiency of spectral observations. The Javalambre Photometric Local Universe Survey (J-PLUS) is an observational campaign that aims to obtain photometry in 12 bands. Owing to its characteristics, J-PLUS data have become a valuable resource for studies of stars. Machine learning provides powerful tools for efficiently analyzing large data sets, such as the one from J-PLUS, and enables us to expand the research domain to stellar parameters. The main goal of this study is to construct a support vector regression (SVR) algorithm to estimate stellar parameters of the stars in the first data release of the J-PLUS observational campaign. The training data for the parameter's regressions are featured with 12-waveband photometry from J-PLUS and are crossidentified with spectrum-based catalogs. These catalogs are from the Large Sky Area Multi-Object Fiber Spectroscopic Telescope, the Apache Point Observatory Galactic Evolution Experiment, and the Sloan Extension for Galactic Understanding and Exploration. We then label them with the stellar effective temperature, the surface gravity, and the metallicity. Ten percent of the sample is held out to apply a blind test. We develop a new method, a multi-model approach, in order to fully take into account, the uncertainties of both the magnitudes and the stellar parameters. The method utilizes more than 200 models to apply the uncertainty analysis. We present a catalog of 2 493 424 stars with the root mean square error of 160 K in the effective temperature regression, 0.35 in the surface gravity regression, and 0.25 in the metallicity regression. We also discuss the advantages of this multi-model approach and compare it to other machine-learning methods.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-D-BRF-05: Quantitative Dual-Energy CT Imaging for Proton Stopping Power Computation

Purpose: To extend the two-parameter separable basis-vector model (BVM) to estimation of proton stopping power from dual-energy CT (DECT) imaging. Methods: BVM assumes that the photon cross sections of any unknown material can be represented as a linear combination of the corresponding quantities for two bracketing basis materials. We show that both the electron density (ρe) and mean excitation energy (Iex) can be modeled by BVM, enabling stopping power to be estimated from the Bethe-Bloch equation. We have implemented an idealized post-processing dual energy imaging (pDECT) simulation consisting of monogenetic 45 keV and 80 keV scanning beams with polystyrene-water and water-CaCl2 solution basis pairs for soft tissues and bony tissues, respectively. The coefficients of 24 standard ICRU tissue compositions were estimated by pDECT. The corresponding ρe, Iex, and stopping power tables were evaluated via BVM and compared to tabulated ICRU 44 reference values. Results: BVM-based pDECT was found to estimate ρe and Iex with average and maximum errors of 0.5% and 2%, respectively, for the 24 tissues. Proton stopping power values at 175 MeV, show average/maximum errors of 0.8%/1.4%. For adipose, muscle and bone, these errors result range prediction accuracies less than 1%. Conclusion: A new two-parameter separable DECT model (BVM) for estimating proton stopping power was developed. Compared to competing parametric fit DECT models, BVM has the comparable prediction accuracy without necessitating iterative solution of nonlinear equations or a sample-dependent empirical relationship between effective atomic number and Iex. Based on the proton BVM, an efficient iterative statistical DECT reconstruction model is under development.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of deformable registration on the dose calculated in radiation therapy planning CT scans of lung cancer patients

Purpose: To characterize the effects of deformable image registration of serial computed tomography (CT) scans on the radiation dose calculated from a treatment planning scan. Methods: Eighteen patients who received curative doses (≥60 Gy, 2 Gy/fraction) of photon radiation therapy for lung cancer treatment were retrospectively identified. For each patient, a diagnostic-quality pretherapy (4–75 days) CT scan and a treatment planning scan with an associated dose map were collected. To establish correspondence between scan pairs, a researcher manually identified anatomically corresponding landmark point pairs between the two scans. Pretherapy scans then were coregistered with planning scans (and associated dose maps) using the demons deformable registration algorithm and two variants of the Fraunhofer MEVIS algorithm (“Fast” and “EMPIRE10”). Landmark points in each pretherapy scan were automatically mapped to the planning scan using the displacement vector field output from each of the three algorithms. The Euclidean distance between manually and automatically mapped landmark points (d{sub E}) and the absolute difference in planned dose (|ΔD|) were calculated. Using regression modeling, |ΔD| was modeled as a function of d{sub E}, dose (D), dose standard deviation (SD{sub dose}) in an eight-pixel neighborhood, and the registration algorithm used. Results: Over 1400 landmark point pairs were identified, with 58–93 (median: 84) points identified per patient. Average |ΔD| across patients was 3.5 Gy (range: 0.9–10.6 Gy). Registration accuracy was highest using the Fraunhofer MEVIS EMPIRE10 algorithm, with an average d{sub E} across patients of 5.2 mm (compared with >7 mm for the other two algorithms). Consequently, average |ΔD| was also lowest using the Fraunhofer MEVIS EMPIRE10 algorithm. |ΔD| increased significantly as a function of d{sub E} (0.42 Gy/mm), D (0.05 Gy/Gy), SD{sub dose} (1.4 Gy/Gy), and the algorithm used (≤1 Gy). Conclusions: An average error of <4 Gy in radiation dose was introduced when points were mapped between CT scan pairs using deformable registration, with the majority of points yielding dose-mapping error <2 Gy (approximately 3% of the total prescribed dose). Registration accuracy was highest using the Fraunhofer MEVIS EMPIRE10 algorithm, resulting in the smallest errors in mapped dose. Dose differences following registration increased significantly with increasing spatial registration errors, dose, and dose gradient (i.e., SD{sub dose}). This model provides a measurement of the uncertainty in the radiation dose when points are mapped between serial CT scans through deformable registration.

60 APPLIED LIFE SCIENCES↗

SU-C-209-02: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Clinical Patient Images

Purpose: We develop a method to generate time varying volumetric images (3D fluoroscopic images) using patient-specific motion models derived from four-dimensional cone-beam CT (4DCBCT). Methods: Motion models are derived by selecting one 4DCBCT phase as a reference image, and registering the remaining images to it. Principal component analysis (PCA) is performed on the resultant displacement vector fields (DVFs) to create a reduced set of PCA eigenvectors that capture the majority of respiratory motion. 3D fluoroscopic images are generated by optimizing the weights of the PCA eigenvectors iteratively through comparison of measured cone-beam projections and simulated projections generated from the motion model. This method was applied to images from five lung-cancer patients. The spatial accuracy of this method is evaluated by comparing landmark positions in the 3D fluoroscopic images to manually defined ground truth positions in the patient cone-beam projections. Results: 4DCBCT motion models were shown to accurately generate 3D fluoroscopic images when the patient cone-beam projections contained clearly visible structures moving with respiration (e.g., the diaphragm). When no moving anatomical structure was clearly visible in the projections, the 3D fluoroscopic images generated did not capture breathing deformations, and reverted to the reference image. For the subset of 3D fluoroscopic images generated from projections with visibly moving anatomy, the average tumor localization error and the 95th percentile were 1.6 mm and 3.1 mm respectively. Conclusion: This study showed that 4DCBCT-based 3D fluoroscopic images can accurately capture respiratory deformations in a patient dataset, so long as the cone-beam projections used contain visible structures that move with respiration. For clinical implementation of 3D fluoroscopic imaging for treatment verification, an imaging field of view (FOV) that contains visible structures moving with respiration should be selected. If no other appropriate structures are visible, the images should include the diaphragm. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

TH-EF-207A-01: Respiratory Motion Correction in 4D-Multi Pinhole Small Animal SPECT

Purpose: Respiration causes lesion smearing, image blurring and quality degradation, affecting lesion contrast and the ability to define correct lesion size. The spatial resolution of current multi pinhole SPECT (MPHS) scanners is sub-millimeter. Therefore, the effect of motion is more noticeable in comparison to conventional SPECT scanner. Gated imaging aims to reduce motion artifacts. A major issue in gating is the lack of statistics and individual reconstructed frames are noisy. The increased noise in each frame, deteriorates the quantitative accuracy of the MPHS Images. The objective of this work, is to enhance the image quality in 4D-MPHS imaging, by 4D image reconstruction. Methods: The new algorithm requires deformation vector fields (DVFs) that are calculated by non-rigid Demons registration. The algorithm is based on the motion-incorporated version of ordered subset expectation maximization (OSEM) algorithm. This iterative algorithm is capable to make full use of all projections to reconstruct each individual frame. To evaluate the performance of the proposed algorithm a simulation study was conducted. A fast ray tracing method was used to generate MPHS projections of a 4D digital mouse phantom with a small tumor in liver in eight different respiratory phases. To evaluate the 4D-OSEM algorithm potential, tumor to liver activity ratio was compared with other image reconstruction methods including 3D-MPHS and post reconstruction registered with Demons-derived DVFs. Results: Image quality of 4D-MPHS is greatly improved by the 4D-OSEM algorithm. When all projections are used to reconstruct a 3D-MPHS, motion blurring artifacts are present, leading to overestimation of the tumor size and 24% tumor contrast underestimation. This error reduced to 16% and 10% for post reconstruction registration methods and 4D-OSEM respectively. Conclusion: 4D-OSEM method can be used for motion correction in 4D-MPHS. The statistics and quantification are improved since all projection data are combined together to update the image.

60 APPLIED LIFE SCIENCES↗

Geometric Interpretation of the Cluster Location Problem Part I: Theory

We present a new framing of the seismic location problem using principles drawn from differential geometry. Our interpretation relies upon the common assumption that travel times observed across a network are continuous, differentiable functions of source location. In consequence, travel‐time functions constitute a differentiable map between the source region and a Riemannian manifold. The manifold is said to be the image of the source region embedded in a generally high‐dimension travel‐time vector space. A cluster of events in the source region has an image of discrete points on the manifold, that, except in the simplest cases, cannot be viewed directly. However, it is possible to project the image of a cluster into a tangent space of the manifold for direct visualization. The projection operator can be computed directly from the data without a velocity model, but produces a distorted rendering of the cluster geometry. With a model we can predict the distortions and correct them to estimate cluster geometry. We develop these points with the simplest possible example, one for which direct visualization of the manifold is possible, using the example as an introduction to the relevant concepts from differential geometry in a familiar setting. The tangent space, a local linearization of the manifold, plays a key role. We develop a metric to estimate the limits of linearization, that is, to determine when the curvature of the manifold invalidates the linear assumption. We also examine the interplay of model error, inadequate network geometry, and pick error. We then generalize our results from the simple case to the general case of 3D source regions observed by general networks. Although we do suggest a new “project and correct” method for location, we do not develop it into a practical algorithm. In conclusion, our intention rather is to highlight new analytical methods grounded in differential geometry.

East Pacific Ocean Islands↗

Ancilla-entangling Floquet kicks for accelerating quantum algorithms

Quantum simulation with adiabatic annealing can provide insight into difficult problems that are impossible to study with classical computers. However, it deteriorates when the systems scale up due to the shrinkage of the excitation gap and thus places an annealing rate bottleneck for high success probability. Here, in this study, we accelerate quantum simulation using digital multiqubit gates that entangle primary system qubits with ancillary qubits. The practical benefits originate from tuning the ancillary gauge degrees of freedom to enhance the quantum algorithm's original functionality in the system registry. For simple but nontrivial short-ranged, infinite long-ranged transverse-field Ising models, and the hydrogen molecule model after qubit encoding, we show improvement in the time to solution by one hundred percent but with higher accuracy through exact state-vector numerical simulation in a digital-analog setting. The findings are further supported by time-averaged Hamiltonian theory.

97 MATHEMATICS AND COMPUTING↗

Noise Decoherence and Errors from Entanglement-function Theory for Quantum Computing

A significant problem in quantum computing is the development of physical realizations of algorithms that are robust against noise. One way to examine and mitigate noise would be to simulate large sets of qubits coupling to the external environment on classical computers. This is extremely challenging as quantum information processing is in some sense tied to computing resources that scale exponentially with the number of computing elements (qubits). In this LDRD, we set the foundation for a computational framework potentially allowing simulations of 1000s of qubits vs. 10s now possible. Exact wave-function-based methods demand exponentially increasing resources with system size. The method proposed, entanglement-functional theory (EFT), requires vastly fewer resources. The crucial step is to map the information contained in the wave-functions into a simpler object with associated 1.) auxiliary gate operations and 2.) entanglement functionals of this object. This is similar to the Time-dependent Density Functional Theory (TDDFT) approach that has revolutionized chemistry and materials science. Instead of dealing with the exponentially large wave-function, EFT works with a polynomially large set of projections (the density) that are easily manipulated through unitary operations. For a given set of quantum gates, an isomorphism exists that relates the sequence of events to the time-dependent density. A system of entangled qubits can be simulated at drastically reduced cost relative to existing state-of-the-art vector-state simulation codes.

97 MATHEMATICS AND COMPUTING↗

TH-A-BRF-08: Deformable Registration of MRI and CT Images for MRI-Guided Radiation Therapy

Purpose: To evaluate the quality of a commercially available MRI-CT image registration algorithm and then develop a method to improve the performance of this algorithm for MRI-guided prostate radiotherapy. Methods: Prostate contours were delineated on ten pairs of MRI and CT images using Eclipse. Each pair of MRI and CT images was registered with an intensity-based B-spline algorithm implemented in Velocity. A rectangular prism that contains the prostate volume was partitioned into a tetrahedral mesh which was aligned to the CT image. A finite element method (FEM) was developed on the mesh with the boundary constraints assigned from the Velocity generated displacement vector field (DVF). The resultant FEM displacements were used to adjust the Velocity DVF within the prism. Point correspondences between the CT and MR images identified within the prism could be used as additional boundary constraints to enforce the model deformation. The FEM deformation field is smooth in the interior of the prism, and equal to the Velocity displacements at the boundary of the prism. To evaluate the Velocity and FEM registration results, three criteria were used: prostate volume conservation and center consistence under contour mapping, and unbalanced energy of their deformation maps. Results: With the DVFs generated by the Velocity and FEM simulations, the prostate contours were warped from MRI to CT images. With the Velocity DVFs, the prostate volumes changed 10.2% on average, in contrast to 1.8% induced by the FEM DVFs. The average of the center deviations was 0.36 and 0.27 cm, and the unbalance energy was 2.65 and 0.38 mJ/cc3 for the Velocity and FEM registrations, respectively. Conclusion: The adaptive FEM method developed can be used to reduce the error of the MIbased registration algorithm implemented in Velocity in the prostate region, and consequently may help improve the quality of MRI-guided radiation therapy.

60 APPLIED LIFE SCIENCES↗

Leveraging machine learning to enhance aerosol classification using Single-Particle Mass Spectrometry

Advancing automated classification of atmospheric aerosols from Single-Particle Mass Spectrometry (SPMS) data remains challenging due to overlapping ion signatures, compositional diversity, and limited labeled data. This study evaluates supervised and semi-supervised learning frameworks to enhance aerosol identification by jointly leveraging labeled and unlabeled spectra. Four models were compared: a supervised Support Vector Machine (SVM), a self-training SVM, a stacked autoencoder classifier, and a stacked autoencoder trained using a temporal-ensembling Mean Teacher approach. All models achieved high and stable accuracies (90.0 %–91.1 %), surpassing previous results on the same dataset (87 %) and matching the performance of state-of-the-art deep learning methods. Despite small global metric differences (≤ 1 %), semi-supervised variants yielded up to 5 %–10 % improvements for compositionally rare particle types – such as soot (0.77 % of spectra, F1-score: 0.93–0.97) and hazelnut pollen (0.98 % of spectra, F1-score: 0.97–1.00) – equating to roughly ∼ 187 additional correctly classified spectra. These gains are scientifically significant, as such rare particles exert disproportionate influence on radiative absorption and ice nucleation processes; their improved detection reduces modeled uncertainties in aerosol absorption optical depth and mixed-phase cloud ice nucleation rates. The models' residual misclassifications (≈ 9 %) largely arise from true spectral overlap among chemically adjacent species (e.g., Na- vs. K-feldspar, coated vs. uncoated feldspars), reflecting physical compositional continuity rather than algorithmic error. Collectively, these findings demonstrate that leveraging unlabeled data to learn robust spectral representations and refine classification enhances both fidelity and interpretability, bridging data-driven analysis with aerosol–climate process understanding.

54 ENVIRONMENTAL SCIENCES↗

Overview of new MAST physics in anticipation of first results from MAST Upgrade

We report that the mega amp spherical tokamak (MAST) was a low aspect ratio device (R/a = 0.85/0.65 ~ 1.3) with similar poloidal cross-section to other medium-size tokamaks. The physics programme concentrates on addressing key physics issues for the operation of ITER, design of DEMO and future spherical tokamaks by utilising high resolution diagnostic measurements closely coupled with theory and modelling to significantly advance our understanding. An empirical scaling of the energy confinement time that favours higher power, lower collisionality devices is consistent with gyrokinetic modelling of electron scale turbulence. Measurements of ion scale turbulence with beam emission spectroscopy and gyrokinetic modelling in up-down symmetric plasmas find that the symmetry of the turbulence is broken by flow shear. Near the non-linear stability threshold, flow shear tilts the density fluctuation correlation function and skews the fluctuation amplitude distribution. Results from fast particle physics studies include the observation that sawteeth are found to redistribute passing and trapped fast particles injected from neutral beam injectors in equal measure, suggesting that resonances between the m = 1 perturbation and the fast ion orbits may be playing a dominant role in the fast ion transport. Measured D–D fusion products from a neutron camera and a charged fusion product detector are 40% lower than predictions from TRANSP/NUBEAM, highlighting possible deficiencies in the guiding centre approximation. Modelling of fast ion losses in the presence of resonant magnetic perturbations (RMPs) can reproduce trends observed in experiments when the plasma response and charge-exchange losses are accounted for. Measurements with a neutral particle analyser during merging-compression start-up indicate the acceleration of ions and electrons. Transport at the plasma edge has been improved through reciprocating probe measurements that have characterised a geodesic acoustic mode at the edge of an ohmic L-mode plasma and particle-in-cell modelling has improved the interpretation of plasma potential estimates from ball-pen probes. The application of RMPs leads to a reduction in particle confinement in L-mode and H-mode and an increase in the core ionization source. The ejection of secondary filaments following type-I ELMs correlates with interactions with surfaces near the X-point. Simulations of the interaction between pairs of filaments in the scrape-off layer suggest this results in modest changes to their velocity, and in most cases can be treated as moving independently. A stochastic model of scrape-off layer profile formation based on the superposition of non-interacting filaments is in good agreement with measured time-average profiles. Transport in the divertor has been improved through fast camera imaging, indicating the presence of a quiescent region devoid of filament near the X-point, extending from the separatrix to $ψ_n$ ~ 1.02. Simulations of turbulent transport in the divertor show that the angle between the divertor leg on the curvature vector strongly influences transport into the private flux region via the interchange mechanism. Coherence imaging measurements show counter-streaming flows of impurities due to gas puffing increasing the pressure on field lines where the gas is ionised. MAST Upgrade is based on the original MAST device, with substantially improved capabilities to operate with a Super-X divertor to test extended divertor leg concepts. SOLPS-ITER modelling predicts the detachment threshold will be reduced by more than a factor of 2, in terms of upstream density, in the Super-X compared with a conventional configuration and that the radiation front movement is passively stabilised before it reaches the X-point. 1D fluid modelling reveals the key role of momentum and power loss mechanisms in governing detachment onset and evolution. Analytic modelling indicates that long legs placed at large major radius, or equivalently low at the target compared with the X-point are more amenable to external control. With MAST Upgrade experiments expected in 2019, a thorough characterisation of the sources of the intrinsic error field has been carried out and a mitigation strategy developed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging

Purpose: 4D cone beam CT (4D-CBCT) has been utilized in radiation therapy to provide 4D image guidance in lung and upper abdomen area. However, clinical application of 4D-CBCT is currently limited due to the long scan time and low image quality. The purpose of this paper is to develop a new 4D-CBCT reconstruction method that restores volumetric images based on the 1-min scan data acquired with a standard 3D-CBCT protocol. Methods: The model optimizes a deformation vector field that deforms a patient-specific planning CT (p-CT), so that the calculated 4D-CBCT projections match measurements. A forward-backward splitting (FBS) method is invented to solve the optimization problem. It splits the original problem into two well-studied subproblems, i.e., image reconstruction and deformable image registration. By iteratively solving the two subproblems, FBS gradually yields correct deformation information, while maintaining high image quality. The whole workflow is implemented on a graphic-processing-unit to improve efficiency. Comprehensive evaluations have been conducted on a moving phantom and three real patient cases regarding the accuracy and quality of the reconstructed images, as well as the algorithm robustness and efficiency. Results: The proposed algorithm reconstructs 4D-CBCT images from highly under-sampled projection data acquired with 1-min scans. Regarding the anatomical structure location accuracy, 0.204 mm average differences and 0.484 mm maximum difference are found for the phantom case, and the maximum differences of 0.3–0.5 mm for patients 1–3 are observed. As for the image quality, intensity errors below 5 and 20 HU compared to the planning CT are achieved for the phantom and the patient cases, respectively. Signal-noise-ratio values are improved by 12.74 and 5.12 times compared to results from FDK algorithm using the 1-min data and 4-min data, respectively. The computation time of the algorithm on a NVIDIA GTX590 card is 1–1.5 min per phase. Conclusions: High-quality 4D-CBCT imaging based on the clinically standard 1-min 3D CBCT scanning protocol is feasible via the proposed hybrid reconstruction algorithm.

60 APPLIED LIFE SCIENCES↗

First-Principles Quantum Transport Modeling of Spin-Transfer and Spin-Orbit Torques in Magnetic Multilayers

A unified approach for computing (i) spin-transfer torque in magnetic trilayers like spin valve and magnetic tunnel junction, where injected charge current flows perpendicularly to interfaces, and (ii) spin-orbit torque in magnetic bilayers of the type ferromagnet/spin-orbit-coupled material, where injected charge current flows parallel to the interface, was reviewed. The experimentally explored and technologically relevant spin-orbit-coupled materials include 5d heavy metals, topological insulators, Weyl semimetals, and transition metal dichalcogenides. This approach requires to construct the torque operator for a given Hamiltonian of the device and the steady-state nonequilibrium density matrix, where the latter is expressed in terms of the nonequilibrium Green’s functions and split into three contributions. Tracing these contributions with the torque operator automatically yields field-like and damping-like components of spin-transfer torque or spin-orbit torque vector, which is particularly advantageous for spin-orbit torque where the direction of these components depends on the unknown-in-advance orientation of the current-driven nonequilibrium spin density in the presence of spin-orbit coupling. Illustrative examples are provided by computing spin-transfer torque in a one-dimensional toy model of a magnetic tunnel junction and realistic Co/Cu/Co spin valve, both of which are described by first-principles Hamiltonians obtained from noncollinear density functional theory calculations, as well as by computing spin-orbit torque in a ferromagnetic layer described by a tight-binding Hamiltonian which includes spin-orbit proximity effect within ferromagnetic monolayers assumed to be generated by the adjacent monolayer transition metal dichalcogenide. In addition, it is shown here how spin-orbit proximity effect, quantified by computing (via first-principles retarded Green’s function) spectral functions and spin textures on monolayers of realistic ferromagnetic material like Co in contact with heavy metal or monolayer transition metal dichalcogenide, can be tailored to enhance the magnitude of spin-orbit torque. Furthermore, errors made in the calculation of spin-transfer torque are quantified when using Hamiltonian from collinear density functional theory, with rigidly rotated magnetic moments to create noncollinear magnetization configurations, instead of proper (but computationally more expensive) self-consistent Hamiltonian obtained from noncollinear density functional theory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Online adaptive basis refinement and compression for reduced-order models via vector-space sieving

In many applications, projection-based reduced-order models (ROMs) have demonstrated the ability to provide rapid approximate solutions to high-fidelity full-order models (FOMs). However, there is no a priori assurance that these approximate solutions are accurate; their accuracy depends on the ability of the low-dimensional trial basis to represent the FOM solution. As a result, ROMs can generate inaccurate approximate solutions, e.g., when the FOM solution at the online prediction point is not well represented by training data used to construct the trial basis. To address this fundamental deficiency of standard model-reduction approaches, this work proposes a novel online-adaptive mechanism for efficiently enriching the trial basis in a manner that ensures convergence of the ROM to the FOM, yet does not incur any FOM solves. The mechanism is based on the previously proposed adaptive $h$-refinement method for ROMs, but improves upon this work in two crucial ways. First, the proposed method enables basis refinement with respect to any orthogonal basis (not just the Kronecker basis), thereby generalizing the refinement mechanism and enabling it to be tailored to the physics characterizing the problem at hand. Second, the proposed method provides a fast online algorithm for periodically compressing the enriched basis via an efficient proper orthogonal decomposition (POD) method, which does not incur any operations that scale with the FOM dimension. We report these two features allow the proposed method to serve as (1) a failsafe mechanism for ROMs, as the method enables the ROM to satisfy any prescribed error tolerance online (even in the case of inadequate training), and (2) an efficient online basis-adaptation mechanism, as the combination of basis enrichment and compression enables the basis to adapt online while controlling its dimension.

42 ENGINEERING↗

Bounding entanglement entropy with Clifford double cosets

Following on our previous work studying the orbits of quantum states under Clifford circuits via reachability graphs, we introduce contracted graphs whose vertices represent classes of quantum states with the same entropy vector. These contracted graphs represent the double cosets of the Clifford group, where the left cosets are built from the stabilizer subgroup of the starting state and the right cosets are built from the entropy-preserving operators. We study contracted graphs for stabilizer states, as well as 𝑊 states and Dicke states, discussing how the diameter of a state's contracted graph constrains the entropic diversity of its two-qubit Clifford orbit. We derive an upper bound on the number of entropy vectors that can be generated using any 𝑛-qubit Clifford circuit, for any quantum state. Here, we speculate on the holographic implications for the relative proximity of gravitational duals of states within the same Clifford orbit. Although we concentrate on how entropy evolves under the Clifford group, our double-coset formalism, and thus the contracted graph picture, is extendable to generic gate sets and generic state properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerically approximating centrality for graph ranking guarantees

Many real-world datasets can be represented as graphs. Using iterative solvers to approximate graph centrality measures allows us to obtain a ranking vector on the nodes of the graph, consisting of a number for each vertex in the graph identifying its relative importance. In this study the centrality measures we use are Katz Centrality and PageRank. Given an approximate solution, we use the residual to accurately estimate how much of the ranking matches the ranking given by the exact solution. Using probabilistic matrix norms, we obtain bounds on the accuracy of the approximation compared to the exact solution with respect to the highly ranked nodes and apply numerical analysis to the computation of centrality with iterative methods. This relates the numerical accuracy of the linear solver to the data analysis accuracy of finding the correct ranking. In particular, we answer the question of which pairwise rankings are reliable given an approximate solution to the linear system. Experiments on many real-world undirected and directed networks up to several million vertices and several hundred million edges validate our theory and show that we are able to accurately estimate large portions of the approximation. We also analyze the difference between global centrality scores and personalized scores (w.r.t. specific seed vertices). By analyzing convergence error, we develop confidence in the ranking schemes of data mining. We show we are able to accurately guarantee ranking of vertices with an approximation to centrality metrics faster than current methods.

97 MATHEMATICS AND COMPUTING↗

WE-G-BRF-04: Robust Real-Time Volumetric Imaging Based On One Single Projection

Purpose: Real-time volumetric imaging is highly desirable to provide instantaneous image guidance for lung radiation therapy. This study proposes a scheme to achieve this goal using one single projection by utilizing sparse learning and a principal component analysis (PCA) based lung motion model. Methods: A patient-specific PCA-based lung motion model is first constructed by analyzing deformable vector fields (DVFs) between a reference image and 4DCT images at each phase. At the training stage, we “learn” the relationship between the DVFs and the projection using sparse learning. Specifically, we first partition the projections into patches, and then apply sparse learning to automatically identify patches that best correlate with the principal components of the DVFs. Once the relationship is established, at the application stage, we first employ a patchbased intensity correction method to overcome the problem of different intensity scale between the calculated projection in the training stage and the measured projection in the application stage. The corrected projection image is then fed to the trained model to derive a DVF, which is applied to the reference image, yielding a volumetric image corresponding to the projection. We have validated our method through a NCAT phantom simulation case and one experiment case. Results: Sparse learning can automatically select those patches containing motion information, such as those around diaphragm. For the simulation case, over 98% of the lung region pass the generalized gamma test (10HU/1mm), indicating combined accuracy in both intensity and spatial domain. For the experimental case, the average tumor localization errors projected to the imager are 0.68 mm and 0.4 mm on the axial and tangential direction, respectively. Conclusion: The proposed method is capable of accurately generating a volumetric image using one single projection. It will potentially offer real-time volumetric image guidance to facilitate lung radiotherapy. This study is supported in part by NIH (1R01CA154747-01), The Core Technology Research in Strategic Emerging Industry, Guangdong, China(2011A081402003)

60 APPLIED LIFE SCIENCES↗