Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

A numerical Poisson solver with improved radial solutions for a self-consistent locally scaled self-interaction correction method

Abstract The universal applicability of density functional approximations is limited by self-interaction error made by these functionals. Recently, a novel one-electron self-interaction-correction (SIC) method that uses an iso-orbital indicator to apply the SIC at each point in space by scaling the exchange-correlation and Coulomb energy densities was proposed. The locally scaled SIC (LSIC) method is exact for the one-electron densities, and unlike the well-known Perdew–Zunger SIC (PZSIC) method recovers the uniform electron gas limit of the uncorrected density functional approximation, and reduces to PZSIC method as a special case when isoorbital indicator is set to the unity. Here, we present a numerical scheme that we have adopted to evaluate the Coulomb potential of the electron density scaled by the iso-orbital indicator required for the self-consistent LSIC calculations. After analyzing the behavior of the finite difference method (FDM) and the green function solution to the radial part of the Poisson equation, we adopt a hybrid approach that uses the FDM for the Coulomb potential due to the monopole and the GF for all higher-order terms. The performance of the resultant hybrid method is assessed using a variety of systems. The results show improved accuracy than earlier numerical schemes. We also find that, even with a generic set of radial grid parameters, accurate energy differences can be obtained using a numerical Coulomb solver in standard density functional studies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of setup error using different reference images: a phantom and lung cancer patients study

The purpose of this study was to compare setup errors obtained with kilovoltage cone-beam computed tomography (CBCT) and 2 different kinds of reference images, free-breathing 3D localization CT images (FB-CT) and the average images of 4-D localization CT images (AVG-CT) for phantom and lung cancer patients. This study also explored the correlation between the difference of translational setup errors and the gross tumor volume (GTV) motion. A respiratory phantom and 14 patients were enrolled in this study. For phantom and each patient, 3D helical CT and 4D CT images were acquired, and AVG-CT images were generated from the 4D CT. The setup errors were determined based on the image registration between the CBCT and the 2 different reference images, respectively. The data for both translational and rotational setup errors were analyzed and compared. The GTV centroid movement as well as its correlation with the translational setup error differences was also evaluated. In the phantom study, the AVG-CT method was more accurate than the FB-CT method. For patients, the translational setup errors based on FB-CT were significantly larger than those from AVG-CT in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions (p < 0.05). Translational setup errors differed by >1 mm in 32.6% and >2 mm in 12.9% of CBCT scans. The rotational setup errors from FB-CT were significantly different from those from AVG-CT in the LR and AP directions (p < 0.05). The correlation coefficient of the translational setup error differences and the GTV centroid movement in the LR, SI, and AP directions was 0.515 (p = 0.060), 0.902 (p < 0.001), and 0.510 (p = 0.062), respectively. For lung cancer patients, respiration may affect the on-line target position location. AVG-CT provides different reference information than FB-CT. The difference in SI direction caused by the 2 methods increases with the GTV movement. Therefore, AVG-CT should be the prefered choice of reference images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Three sources of errors in the Ehrenfest treatment of inelastic scattering and possible ways of resolving them

In order to identify the origin of possible errors in the mixed quantum/classical approach to inelastic scattering [A. Semenov and D. Babikov, J. Chem. Phys. 140, 044306 (2014) and A. Semenov, M.-L. Dubernet, and D. Babikov, J. Chem. Phys. 141, 114304 (2014)], a simplified model is considered that consists of one intermolecular degree of freedom and two intramolecular states, coupled by a simple potential. For this system, analytic derivations are carried out to determine (i) the exact quantum mechanical solution of the inelastic scattering problem, (ii) a simplified version of it with all oscillatory terms neglected, and (iii) the Ehrenfest solution in which the translational motion is described by the mean-field trajectory while the internal molecular motion is treated by the time-dependent Schrodinger equation. It is shown that the appropriate choice of velocity for the mean-field trajectory permits to enforce microscopic reversibility and gives results in excellent agreement with full-quantum results. The average velocity method of Billing is rigorously derived as a limiting case (of this more general approach), when reversibility is enforced locally, at the initial moment of time only. It is demonstrated that errors of state-to-state transition probabilities in the Ehrenfest approach occur at lower values of total energy E if the magnitudes of excitation energy ΔE, potential energy difference between the two states ΔV, and coupling of two states V12 are large. Possible ways of applying this concept to rotational transitions in real molecules are explored, using examples from CO + CO inelastic scattering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Objective assessment of deformable image registration in radiotherapy: A multi-institution study

The looming potential of deformable alignment tools to play an integral role in adaptive radiotherapy suggests a need for objective assessment of these complex algorithms. Previous studies in this area are based on the ability of alignment to reproduce analytically generated deformations applied to sample image data, or use of contours or bifurcations as ground truth for evaluation of alignment accuracy. In this study, a deformable phantom was embedded with 48 small plastic markers, placed in regions varying from high contrast to roughly uniform regional intensity, and small to large regional discontinuities in movement. CT volumes of this phantom were acquired at different deformation states. After manual localization of marker coordinates, images were edited to remove the markers. The resulting image volumes were sent to five collaborating institutions, each of which has developed previously published deformable alignment tools routinely in use. Alignments were done, and applied to the list of reference coordinates at the inhale state. The transformed coordinates were compared to the actual marker locations at exhale. A total of eight alignment techniques were tested from the six institutions. All algorithms performed generally well, as compared to previous publications. Average errors in predicted location ranged from 1.5 to 3.9 mm, depending on technique. No algorithm was uniformly accurate across all regions of the phantom, with maximum errors ranging from 5.1 to 15.4 mm. Larger errors were seen in regions near significant shape changes, as well as areas with uniform contrast but large local motion discontinuity. Although reasonable accuracy was achieved overall, the variation of error in different regions suggests caution in globally accepting the results from deformable alignment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the Viability of Video Imaging in Leak Rate Quantification: A Theoretical Error Analysis

Optical gas imaging through multispectral cameras is a promising technique for mitigation of methane emissions through localization and quantification of emissions sources. While more advanced cameras developed in recent years have led to lower uncertainties in measuring gas concentrations, a systematic analysis of the uncertainties associated with leak rate estimation have been overlooked. We present a systematic categorization of the involved uncertainties with a focus on a theoretical analysis of projection uncertainties that are inherent to this technique. The projection uncertainties are then quantified using Large Eddy Simulation experiments of a point source release into the atmosphere. Our results show that while projection uncertainties are typically about 5% of the emission rate, low acquisition times and observation of the gas plume at small distances from the emission source (<10 m) can amount to errors of about 20%. Further, we found that acquisition times on the order of tens of seconds are sufficient to significantly reduce (>50%) the projection uncertainties. These findings suggest robust procedures on how to reduce projection uncertainties, however, a balance between other sources of uncertainty due to operational conditions and the employed instrumentation are required to outline more practical guidelines.

47 OTHER INSTRUMENTATION↗

The Area Localized Coupled Model for Analytical Mean Flow Prediction in Arbitrary Wind Farm Geometries

This work introduces the area localized coupled (ALC) model, which extends the applicability of approaches that couple classical wake superposition models and atmospheric boundary layer models to wind farms with arbitrary layouts. Coupling wake and top–down boundary layer models is particularly challenging since the latter requires averaging over planform areas associated with turbine-specific regions of the flow that need to be specified. The ALC model uses Voronoi tessellation to define this local area around each turbine. A top–down description of a developing internal boundary layer is then applied over Voronoi cells upstream of each turbine to estimate the local mean velocity profile. Coupling between the velocity at hub-height based on this localized top–down model and a wake model is achieved by enforcing a minimum least-square-error in mean velocity in each cell. The wake model in the present implementation takes into account variations in wind farm inflow velocity and represents the wake profile behind each turbine as a super-Gaussian function that smoothly transitions between a top-hat shape in the region immediately following the turbine to a Gaussian profile downstream. Detailed comparisons to large-eddy simulation (LES) data from two different wind farms demonstrate the efficacy of the model in accurately predicting both wind farm power output and local turbine hub-height velocity for different wind farm geometries. These validations using data generated from two different LES codes demonstrate the model's versatility with respect to capturing results from different simulation setups and wind farm configurations.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Dual-map framework for noise characterization of quantum computers

In order to understand the capabilities and limitations of quantum computers, it is necessary to develop methods that efficiently characterize and benchmark error channels present on these devices. In this paper, we present a method that faithfully reconstructs a marginal (local) approximation of the effective noise (MATEN) channel, that acts as a single layer at the end of the circuit. We first introduce a dual-map framework that allows us to analytically derive expectation values of observables with respect to noisy circuits. These findings are supported by numerical simulations of the quantum approximate optimization algorithm (QAOA) that also justify the MATEN, even in the presence of nonlocal errors that occur during a circuit. Finally, we demonstrate the performance of the method on Rigetti's Aspen-11 quantum computer for QAOA circuits up to six qubits, successfully predicting the observed measurements on a majority of the qubits.

Sud, James↗

Radio follow-up of gravitational-wave triggers during advanced LIGO O1

We present radio follow-up observations carried out with the Karl G. Jansky Very Large Array during the first observing run (O1) of the Advanced Laser Interferometer Gravitational-wave Observatory (LIGO). A total of three gravitational-wave triggers were followed-up during the ≈4 months of O1, from 2015 September to 2016 January. Two of these triggers, GW150914 and GW151226, are binary black hole (BH) merger events of high significance. A third trigger, G194575, was subsequently declared as an event of no interest (i.e., a false alarm). Our observations targeted selected optical transients identified by the intermediate Palomar Transient Factory in the Advanced LIGO error regions of the three triggers, and a limited region of the gravitational-wave localization area of G194575 not accessible to optical telescopes due to Sun constraints, where a possible high-energy transient was identified. No plausible radio counterparts to GW150914 and GW151226 were found, in agreement with expectations for binary BH mergers. We show that combining optical and radio observations is key to identifying contaminating radio sources that may be found in the follow-up of gravitational-wave triggers, such as emission associated with star formation and active galactic nuclei. We discuss our results in the context of the theoretical predictions for radio counterparts to gravitational-wave transients, and describe our future plans for the radio follow-up of Advanced LIGO (and Virgo) triggers.

79 ASTRONOMY AND ASTROPHYSICS↗

A B-spline based gradient-enhanced micropolar implicit material point method for large localized inelastic deformations

The quasi-brittle response of cohesive-frictional materials in numerical simulations is commonly represented by softening plasticity or continuum damage models, either individually or in combination. However, classical models, particularly when coupled with non-associated plasticity, often suffer from ill-posedness and a lack of objectivity in numerical simulations. Moreover, the performance of the finite element method significantly degrades in simulations involving finite strains when mesh distortion reaches excessive levels. This represents a challenge for modeling cohesive-frictional materials, given their tendency to experience strongly localized deformations, such as those occurring during shear band dominated failure. Hence, accurate modeling of the response of cohesive-frictional solids is a demanding task. To address these challenges, we present an extension of the material point method (MPM) for the unified gradient-enhanced micropolar continuum, aiming at the analysis of finite localized inelastic deformations in cohesive-frictional materials. The generalized gradient-enhanced micropolar continuum formulation is employed to tackle challenges related to localization and softening material behavior, while the MPM addresses issues arising from excessive deformations. The method utilizes a B-spline formulation for the rigid background mesh to mitigate the well-known cell crossing errors of the MPM. To demonstrate the performance of the method, 2D and 3D numerical studies on localized failure in sandstone in plane strain compression and triaxial extension tests are presented. A comparison with finite element results confirms the suitability of the formulation. Moreover, an efficient numerical implementation of the formulation is presented, and it is demonstrated that the additional MPM specific overhead is negligible.

B-spline↗

Approximating Quasiparticle and Excitation Energies from Ground State Generalized Kohn–Sham Calculations

Quasiparticle energies and fundamental band gaps specifically are critical properties of molecules and materials. It was rigorously established that the generalized Kohn–Sham HOMO and LUMO orbital energies are the chemical potentials of electron removal and addition and thus good approximations to band edges and fundamental gaps from a density functional approximation (DFA) with minimal delocalization error. For other quasiparticle energies, their connection to the generalized Kohn–Sham orbital energies has not been established but remains highly interesting. We provide the comparison of experimental quasiparticle energies for many finite systems with calculations from the GW Green function and localized orbitals scaling correction (LOSC), a recently developed correction to semilocal DFAs, which has minimal delocalization error. Extensive results with over 40 systems clearly show that LOSC orbital energies achieve slightly better accuracy than the GW calculations with little dependence on the semilocal DFA, supporting the use of LOSC DFA orbital energies to predict quasiparticle energies. This also leads to the calculations of excitation energies of the N-electron systems from the ground state DFA calculations of the (N – 1)-electron systems. Findings show good performance with accuracy similar to TDDFT and the delta SCF approach for valence excitations with commonly used DFAs with or without LOSC. For Rydberg states, good accuracy was obtained only with the use of LOSC DFA. Our report highlights the pathway to quasiparticle and excitation energies from ground density functional calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement theory in local quantum physics

In this paper, we aim to establish foundations of measurement theory in local quantum physics. For this purpose, we discuss a representation theory of completely positive (CP) instruments on arbitrary von Neumann algebras. We introduce a condition called the normal extension property (NEP) and establish a one-to-one correspondence between CP instruments with the NEP and statistical equivalence classes of measuring processes. We show that every CP instrument on an atomic von Neumann algebra has the NEP, extending the well-known result for type I factors. Moreover, we show that every CP instrument on an injective von Neumann algebra is approximated by CP instruments with the NEP. The concept of posterior states is also discussed to show that the NEP is equivalent to the existence of a strongly measurable family of posterior states for every normal state. Two examples of CP instruments without the NEP are obtained from this result. It is thus concluded that in local quantum physics not every CP instrument represents a measuring process, but in most of physically relevant cases every CP instrument can be realized by a measuring process within arbitrary error limits, as every approximately finite dimensional von Neumann algebra on a separable Hilbert space is injective. To conclude the paper, the concept of local measurement in algebraic quantum field theory is examined in our framework. In the setting of the Doplicher-Haag-Roberts and Doplicher-Roberts theory describing local excitations, we show that an instrument on a local algebra can be extended to a local instrument on the global algebra if and only if it is a CP instrument with the NEP, provided that the split property holds for the net of local algebras.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative Density Functional Theory Study of Magnetic Exchange Couplings in Dinuclear Transition-Metal Complexes

Multicenter transition-metal complexes (MCTMs) with magnetically interacting ions have been proposed as components for information-processing devices and storage units. For any practical application of MCTMs as magnetic units, it is crucial to characterize their magnetic behavior, and in particular, the isotropic magnetic exchange coupling, J, between its magnetic centers. Due to the large size of typical MCTMs, density functional theory is the only practical electronic structure method for evaluating the J coupling. Here, we assess the accuracy of different density functional approximations for predicting the magnetic couplings of eight dinuclear transition-metal complexes, including five dimanganese, two dicopper, and one divanadium with known reliable experimental J couplings spanning from ferromagnetic to strong antiferromagnetic. The density functionals considered include global hybrid functionals which mix semilocal density functional approximations and exact exchange with a fixed admixing parameter, six local hybrid functionals where the admixing parameters are extended to be spatially dependent, the SCAN and r 2 SCAN meta-generalized gradient approximations (GGAs), and two widely used GGAs. We found that global hybrids tested in this work have a tendency to over-correct the error in magnetic coupling parameters from the Perdew–Burke–Ernzerhof (PBE) GGA as seen for manganese complexes. The performance of local hybrid density functionals shows no improvement in terms of bias and is scattered without a clear trend, suggesting that more efforts are needed for the extension from global to local hybrid density functionals for this particular property. The SCAN and r 2 SCAN meta-GGAs are found to perform as well as benchmark global hybrids on most tested complexes. We further analyze the charge density redistribution of meta-GGAs as well as global and local hybrid density functionals with respect to that of PBE, in connection to the self-interaction error or delocalization error.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic ionization: sd energy imbalance and Perdew–Zunger self-interaction correction energy penalty in 3d atoms

To accurately describe the energetics of transition metal systems, density functional approximations (DFAs) must provide a balanced description of s- and d- electrons. One measure of this is the sd transfer error, which has previously been defined as E ( 3 d n − 1 4 s 1 ) − E ( 3 d n − 2 4 s 2 ) . Theoretical concerns have been raised about this definition due to its evaluation of excited-state energies using ground-state DFAs. A more serious concern appears to be strong correlation in the 4s 2 configuration. Here, we define a ground-state measure of the sd energy imbalance, based on the errors of s- and d-electron second ionization energies of the 3d atoms, that effectively circumvents the aforementioned problems. We find an improved performance as we move from the local spin density approximation (LSDA) to the Perdew-Burke-Ernzerhof (PBE) generalized gradient approximation (GGA) to the regularized and restored Strongly Constrained and Appropriately Normed (r 2 SCAN) meta-GGA for first-row transition metal atoms. However, we find large (∼2 eV) ground-state sd energy imbalances when applying a Perdew–Zunger 1981 self-interaction correction. This is attributed to an “energy penalty” associated with the noded 3d orbitals. A local scaling of the self-interaction correction to LSDA results in a balance of s- and d-errors.

Science & Technology - Other Topics↗

The galactic halo in mixed dark matter cosmologies

A possible solution to the small scale problems of the cold dark matter (CDM) scenario is that the dark matter consists of two components, a cold and a warm one. We perform a set of high resolution simulations of the Milky Way halo varying the mass of the WDM particle (m{sub WDM}) and the cosmic dark matter mass fraction in the WDM component ( f-bar {sub W}). The scaling ansatz introduced in combined analysis of LHC and astroparticle searches postulates that the relative contribution of each dark matter component is the same locally as on average in the Universe (e.g. f{sub W,s}un = f-bar {sub W}). Here we find however, that the normalised local WDM fraction (f{sub W,s}un / f-bar {sub W}) depends strongly on m{sub WDM} for m{sub WDM} < 1 keV. Using the scaling ansatz can therefore introduce significant errors into the interpretation of dark matter searches. To correct this issue a simple formula that fits the local dark matter densities of each component is provided.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-G-BRA-07: An Innovative Fiducial-Less Tracking Method for Radiation Treatment of Abdominal Tumors by Diaphragm Disparity Analysis

Purpose: To investigate the feasibility of tracking abdominal tumors without the use of gold fiducial markers Methods: In this simulation study, an abdominal 4DCT dataset, acquired previously and containing 8 phases of the breathing cycle, was used as the testing data. Two sets of DRR images (45 and 135 degrees) were generated for each phase. Three anatomical points along the lung-diaphragm interface on each of the Digital Reconstructed Radiograph(DRR) images were identified by cross-correlation. The gallbladder, which simulates the tumor, was contoured for each phase of the breathing cycle and the corresponding centroid values serve as the measured center of the tumor. A linear model was created to correlate the diaphragm’s disparity of the three identified anatomical points with the center of the tumor. To verify the established linear model, we sequentially removed one phase of the data (i.e., 3 anatomical points and the corresponding tumor center) and created new linear models with the remaining 7 phases. Then we substituted the eliminated phase data (disparities of the 3 anatomical points) into the corresponding model to compare model-generated tumor center and the measured tumor center. Results: The maximum difference between the modeled and the measured centroid values across the 8 phases were 0.72, 0.29 and 0.30 pixels in the x, y and z directions respectively, which yielded a maximum mean-squared-error value of 0.75 pixels. The outcomes of the verification process, by eliminating each phase, produced mean-squared-errors ranging from 0.41 to 1.28 pixels. Conclusion: Gold fiducial markers, requiring surgical procedures to be implanted, are conventionally used in radiation therapy. The present work shows the feasibility of a fiducial-less tracking method for localizing abdominal tumors. Through developed diaphragm disparity analysis, the established linear model was verified with clinically accepted errors. The tracking method in real time under different radiation therapy platforms will be further investigated.

60 APPLIED LIFE SCIENCES↗

SU-F-BRF-03: Quality Assurance of Deformable Image Registration in Radiotherapy

Purpose: To introduce methods to analyze Deformable Image Registration (DIR) and identify regions of potential DIR errors. Methods: DIR Deformable Vector Fields (DVFs) quantifying patient anatomic changes were evaluated using the Jacobian determinant and the magnitude of DVF curl as functions of tissue density and tissue type. These quantities represent local relative deformation and rotation, respectively. Large values in dense tissues can potentially identify non-physical DVF errors. For multiple DVFs per patient, histograms and visualization of DVF differences were also considered. To demonstrate the capabilities of methods, we computed multiple DVFs for each of five Head and Neck (H'N) patients (P1–P5) via a Fast-symmetric Demons (FSD) algorithm and via a Diffeomorphic Demons (DFD) algorithm, and show the potential to identify DVF errors. Results: Quantitative comparisons of the FSD and DFD registrations revealed <0.3 cm DVF differences in >99% of all voxels for P1, >96% for P2, and >90% of voxels for P3. While the FSD and DFD registrations were very similar for these patients, the Jacobian determinant was >50% in 9–15% of soft tissue and in 3–17% of bony tissue in each of these cases. The volumes of large soft tissue deformation were consistent for all five patients using the FSD algorithm (mean 15%±4% volume), whereas DFD reduced regions of large deformation by 10% volume (785 cm{sup 3}) for P4 and by 14% volume (1775 cm{sup 3}) for P5. The DFD registrations resulted in fewer regions of large DVF-curl; 50% rotations in FSD registrations averaged 209±136 cm{sup 3} in soft tissue and 10±11 cm{sup 3} in bony tissue, but using DFD these values were reduced to 42±53 cm{sup 3} and 1.1±1.5 cm{sup 3}, respectively. Conclusion: Analysis of Jacobian determinant and curl as functions of tissue density can identify regions of potential DVF errors by identifying non-physical deformations and rotations. Collaboration with Phillips Healthcare, as indicated in authorship.

60 APPLIED LIFE SCIENCES↗

Tumor Localization Using Cone-Beam CT Reduces Setup Margins in Conventionally Fractionated Radiotherapy for Lung Tumors

Purpose: To determine whether setup margins can be reduced using cone-beam computed tomography (CBCT) to localize tumor in conventionally fractionated radiotherapy for lung tumors. Methods and Materials: A total of 22 lung cancer patients were treated with curative intent with conventionally fractionated radiotherapy using daily image guidance with CBCT. Of these, 13 lung cancer patients had sufficient CBCT scans for analysis (389 CBCT scans). The patients underwent treatment simulation in the BodyFix immobilization system using four-dimensional CT to account for respiratory motion. Daily alignment was first done according to skin tattoos, followed by CBCT. All 389 CBCT scans were retrospectively registered to the planning CT scans using automated soft-tissue and bony registration; the resulting couch shifts in three dimensions were recorded. Results: The daily alignment to skin tattoos with no image guidance resulted in systematic ({sigma}) and random ({sigma}) errors of 3.2-5.6 mm and 2.0-3.5 mm, respectively. The margin required to account for the setup error introduced by aligning to skin tattoos with no image guidance was approximately 1-1.6 cm. The difference in the couch shifts obtained from the bone and soft-tissue registration resulted in systematic ({sigma}) and random ({sigma}) errors of 1.5-4.1 mm and 1.8-5.3 mm, respectively. The margin required to account for the setup error introduced using bony anatomy as a surrogate for the target, instead of localizing the target itself, was 0.5-1.4 cm. Conclusion: Using daily CBCT soft-tissue registration to localize the tumor in conventionally fractionated radiotherapy reduced the required setup margin by up to approximately 1.5 cm compared with both no image guidance and image guidance using bony anatomy as a surrogate for the target.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-BRD-08: End-To-End Targeting Accuracy of the Gamma Knife for Trigeminal Neuralgia

Purpose: Current QA procedures verify accuracy of individual equipment parameters, but may not include CT and MRI localizers. This study uses an end-to-end approach to measure the overall targeting errors in individual patients previously treated for trigeminal neuralgia. Methods: The trigeminal nerve is simulated by a 3 mm long, 3.175 mm (1/8 inch) diameter MRI contrast-filled cavity embedded within a PMMA plastic capsule. The capsule is positioned within the head frame such that the cavity position matches the Gamma Knife coordinates of 10 previously treated patients. Gafchromic EBT2 film is placed at the center of the cavity in coronal and sagittal orientations. The films are marked with a pin prick to identify the cavity center. Treatments are planned for delivery with 4 mm collimators using MRI and CT scans acquired with the clinical localizer boxes and acquisition protocols. Coordinates of shots are chosen so that the cavity is centered within the 50% isodose volume. Following irradiation, the films are scanned and analyzed. Targeting errors are defined as the distance between the pin prick and the centroid of the 50% isodose line. Results: Averaged over 10 patient simulations, targeting errors along the x, y and z coordinates (patient left-to-right, posterior-anterior, head-to-foot) were, respectively, −0.060 +/− 0.363, −0.350 +/− 0.253, and 0.364 +/− 0.191 mm when MRI was used for treatment planning. Planning according to CT exhibited generally smaller errors, namely 0.109 +/− 0.167, −0.191 +/− 0.144, and 0.211 +/− 0.94 mm. The largest errors in MRI and CT planned treatments were, respectively, y = −0.761 and x = 0.428 mm. Conclusion: Unless patient motion or stronger MRI image distortion in actual treatments caused additional errors, all patients received the prescribed dose, i.e., the targeted section of the trig±eminal nerve was contained within the 50% isodose surface in all cases.

60 APPLIED LIFE SCIENCES↗