Combined Cr and S poisoning behaviors of La 1-x Sr x MnO 3±δ and La 1-x Sr x Co 1-y FeyO 3-δ cathodes in solid oxide fuel cells
Although the individual effects of airborne Cr and S contaminants on SOFC cathode performance degradation have been extensively studied, the combined effects of Cr and S contaminants remain largely unexplored. Under the real SOFC operating condition where the Cr and S species coexist, their effects may compete, affecting the poisoning behavior. Here, our investigation reveals that the combined Cr and S poisoning behavior of LSCF remains different from those of individual Cr and S poisonings, while the combined poisoning mechanism of LSM is equivalent to the sum of those of individual Cr and S effects. For LSCF electrode, gaseous Cr species are deposited mainly at the LSCF/GDC interface by electrochemical reduction, rather than forming SrCrO 4 on LSCF surfaces (as in the case of Cr-only poisoning), indicating no reaction between Cr vapors and SrO on the LSCF surface. Thermodynamic analysis demonstrates that the SrO on LSCF surface absorbs SO 2 (g) and thereby loses the Cr-gettering effect, allowing Cr vapors to flow through LSCF and to reach the LSCF/GDC interface where the Cr deposition occurs. Unlike LSCF, LSM electrode shows cumulative effects of Cr and S, as Cr accumulation occurs at the triple-phase boundary and S absorption takes place at localized Sr-rich regions.