Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Science Capabilities of the GLAST Burst Monitor

The Large Area Telescope (LAT) on GLAST will make pioneering observations of gamma-ray bursts in the energy range above about 20 MeV. The primary function of the GLAST Burst Monitor (GBM) is to extend the energy range for GRB observations down to about 10 keV, allowing time-resolved spectroscopy over an energy range of six decades or more for strong bursts. The GBM will also generate alerts for strong bursts outside the LAT field-of-view, permitting re-orientation of the spacecraft so that the LAT can observe prompt or delayed high-energy emission. Burst locations will be disseminated rapidly to ground observers. The GBM will also provide data suitable for a variety of other studies, including discovery of gamma-ray transient sources, monitoring of Soft Gamma Repeaters, and observations of solar flares.

Meegan, Charles↗

State-of-the-art of data collection, analytics, and future needs of transmission utilities worldwide to account for the continuous growth of sensing data

Nowadays, transmission system operators require higher degree of observability in real-time to gain situational awareness and improve the decision-making process to guarantee a safe and reliable operation. Digitalization of energy systems allows utilities to monitor the system dynamic performance in real-time at fast time scales. The use of such technologies has unlocked new opportunities to introduce new data driven algorithms for improving the stability assessment and control of the system. Motivated by these challenges, a group of experts have worked together to highlight and establish a baseline set of these common concerns, which can be used as motivation to propose innovative analytics and data-driven solutions. In this document, the results of a survey on 10 transmission system operators around the world are presented and it aims to understand the current practices of the participating companies, in terms of data acquisition, handling, storage, modelling and analytics. The overall objective of this document is to capture the actual needs from the interviewed utilities, thereby laying the groundwork for setting valid assumptions for the development of advanced algorithms in this field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A semiparametric latent factor model for large scale temporal data with heteroscedasticity

Large scale temporal data have flourished in a vast array of applications, and their sophisticated structures, especially the heteroscedasticity among subjects with inter- and intra-temporal dependence, have fueled a great demand for new statistical models. In this paper, with covariate information, we consider a flexible model for large scale temporal data with subject-specific heteroscedasticity. Formally, the model employs latent semiparametric factors to simultaneously account for the subject-specific heteroscedasticity and the contemporaneous and/or serial correlations. The subject-specific heteroscedasticity is modeled as the product of the unobserved factor process and subject’s covariate effect, which is further characterized via additive models. For estimation, we propose a two-step procedure. First, the latent factor process and nonparametric loading are recovered through projection-based methods, and following, we estimate the regression components by approaches motivated from the generalized least squares. By scrupulously examining the non-asymptotic rates for recovering the factor process and its loading, we show the consistency and efficiency of estimated regression coefficients in the absence of prior knowledge of latent factor process and subject’s covariate effect. Here, the statistical guarantees remain valid even for finite time points that makes our method particularly appealing when the subjects significantly outnumber the observation time points. Using comprehensive simulations, we demonstrate the finite sample performance of our method, which corroborates the theoretical findings. Finally, we apply our method to a data set of air quality and energy consumption collected at 129 monitoring sites in the United States in 2015.

97 MATHEMATICS AND COMPUTING↗

Ultrafast Formation of Jahn–Teller Polarons Revealed by State-Selective Excitation in Correlated Spinel Co 3 O 4

Jahn–Teller polarons are quasiparticles that stem from symmetry breaking and strong local electron–phonon coupling. They originate from an excess charge carrier being dressed by a local lattice distortion, caused by the Jahn–Teller effect, and they critically impact electrical, structural, and magnetic properties in transition metal oxides. The observation of the microscopic steps involved in their formation is essential for enabling control over material properties through the targeted activation of local, site-specific modifications with light pulses. While Jahn–Teller distortion associated with polaron formation was predicted to contribute significantly to changes in electronic band gap and optical properties in Co 3 O 4 , its experimental observation remains elusive, requiring signatures of local symmetry reduction. In this work, we demonstrate Jahn–Teller polaron formation in spinel Co 3 O 4 . By exciting electronic transitions at 3.10 eV and 1.55 eV, we target either the Oh Cobalt(III) or the Td Cobalt(II) ions, and drive the subsequent coherent responses of the system through two different pathways. For the former, we demonstrate that ligand-to-metal charge transfer leads to Jahn–Teller polaron formation, which is linked to the deformation potential and magnetoelastic coupling. For the latter, we identify the coherent excitation of a T 2g phonon mode launched by on-site d-d electronic transitions. Key to our observations is the ability to target site-specific electronic excitations in spinel Co 3 O 4 using ultrafast optical pulses, while monitoring the ensuing low-energy collective modes through the coherent time-domain response of the material. Our approach, which combines the comparative analysis of experimental fingerprints with the support from density functional theory calculations, is broadly applicable to systems in which Jahn–Teller polaron physics has been theoretically predicted but remains experimentally unverified, and it underscores the potential of electronic-state targeting as a route to selectively excite and probe quasiparticle dynamics in solids.

Lattices↗

Calibration of the Falcon Solid-state Energetic Electron Detector (SEED)

The Falcon Solid-state Energetic Electron Detector (FalconSEED) is an energetic charged particle sensor that has been developed and tested at the United States Air Force Academy in an effort to monitor electron flux across the energy range of 14 to 145 keV in geosynchronous orbit. This sensor has been developed to complement ongoing efforts by the Air Force Research Laboratory to advance a comprehensive space environment sensor suite, Compact Environmental Anomaly Sensor (CEASE3), for anomaly resolution. In addition, FalconSEED is intended to demonstrate the ability to operate a radiation sensor based on predominantly commercial off the shelf components in the geosynchronous environment. This paper describes the design, development, and calibration of FalconSEED. The electron energy spectrum of interest for the FalconSEED sensor is 14 to 145 keV, and is intended to supplement data acquired from the CEASE3 instrument for anomaly resolution. The calibrations at the Space Atmospheric Research Center at the United States Air Force Academy and Kirtland Air Force Base were used to first establish the conversion between histogram bin number and deposited energy in the sensor, and second have been used to determine the geometric factor as a function of energy. The FalconSEED will be integrated as a science payload on the Space Test Program Satellite-6 which also includes the first flight of the CEASE3 instrument and is scheduled to launch in 2021.

47 OTHER INSTRUMENTATION↗

Remotely Sensed High‐Resolution Soil Moisture and Evapotranspiration: Bridging the Gap Between Science and Society

This paper reviews the current state of high‐resolution remotely sensed soil moisture (SM) and evapotranspiration (ET) products and modeling, and the coupling relationship between SM and ET. SM downscaling approaches for satellite passive microwave products leverage advances in artificial intelligence and high‐resolution remote sensing using visible, near‐infrared, thermal‐infrared, and synthetic aperture radar sensors. Remotely sensed ET continues to advance in spatiotemporal resolutions from MODIS to ECOSTRESS to Hydrosat and beyond. These advances enable a new understanding of bio‐geo‐physical controls and coupled feedback mechanisms between SM and ET reflecting the land cover and land use at field scale (3–30 m, daily). Still, the state‐of‐the‐science products have their challenges and limitations, which we detail across data, retrieval algorithms, and applications. We describe the roles of these data in advancing 10 application areas: drought assessment, food security, precision agriculture, soil salinization, wildfire modeling, dust monitoring, flood forecasting, urban water, energy, and ecosystem management, ecohydrology, and biodiversity conservation. We discuss that future scientific advancement should focus on developing open‐access, high‐resolution (3–30 m), sub‐daily SM and ET products, enabling the evaluation of hydrological processes at finer scales and revolutionizing the societal applications in data‐limited regions of the world, especially the Global South for socio‐economic development.

54 ENVIRONMENTAL SCIENCES↗

Flux-assisted polytypism in the [Na 2 Cl]GaQ 2 heterolayered salt-inclusion chalcogenide family

Two polytypic heterolayered salt-inclusion chalcogenides, o-[Na 2 Cl]GaQ 2 and t-[Na 2 Cl]GaQ 2 , were obtained via a NaCl/NaI flux-assisted synthesis, as part of an investigation of the Na–Ga–Q (Q = S and Se) system. The use of a different flux, NaBr/NaI, in the Na–Ga–Se system did not lead to the formation of salt-inclusion phases, but instead the novel Na 2 GaSe 3 and Na 4 Ga 2 Se 5 phases were obtained. Thermal and electronic properties of [Na 2 Cl]GaS 2 materials were investigated with differential scanning calorimetry, post-quenching ex situ powder X-ray diffraction (PXRD), high-temperature PXRD, and enthalpy and electronic structure calculations via density functional theory. Those studies determined the absence of any temperature-induced phase transition between the o-[Na 2 Cl]GaS 2 and t-[Na 2 Cl]GaS 2 polytypic compounds. Moreover, herein we probed the suitability of the heterolayered [Na 2 Cl]GaS 2 single crystals as a sorbent for UO 2 2+ uptake and monitored this process by energy-dispersive and infrared spectroscopies and PXRD, which revealed that the [Na 2 Cl]+ insert could be exchanged with UO 2 2+ on the surface while the UO 2 2+ intercalation decomposes the [Na 2 Cl]GaS 2 structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward achieving cost-effective hexagonal BN semi-bulk crystals and BN neutron detectors via halide vapor phase epitaxy

Presently, thermal neutron detectors fabricated from boron-10 enriched hexagonal boron nitride (h-10BN) ultrawide bandgap semiconductor grown by metal organic chemical vapor deposition (MOCVD) hold the record high detection efficiency among all solid-state detectors at 59%. To overcome the short comings of MOCVD growth, including inherently low growth rate and unavoidable impurities such as carbon in metal organic source, we demonstrate here the growth of natural hexagonal boron nitride (h-BN) semi-bulk wafers using halide vapor phase epitaxy (HVPE), which is an established technique for producing GaN semi-bulk crystals at a high growth rate. Electrical transport characterization results revealed that these HVPE grown materials possess an electrical resistivity of 1 × 1013 Ω cm, and a charge carrier mobility and lifetime product of 2 × 10−4 cm2/V s. Detectors fabricated from a 100 μm thick h-BN wafer have demonstrated a thermal neutron detection efficiency of 20%, corresponding to a charge collection efficiency of ∼60% at an operating voltage of 500 V. This initial demonstration opens the door for mass producing high efficiency h-BN semiconductor neutron detectors at a reduced cost, which could create unprecedented applications in nuclear energy, national security, nuclear waste monitoring and management, the health care industry, and material sciences.

Physics↗

Photoelectron spectroscopy with entangled photons; enhanced spectrotemporal resolution

In this theoretical study, we show how photoelectron signals generated by time-energy entangled photon pairs can monitor ultrafast excited state dynamics of molecules with high joint spectral and temporal resolutions, not limited by the Fourier uncertainty of classical light. This technique scales linearly, rather than quadratically, with the pump intensity, allowing the study of fragile biological samples with low photon fluxes. Since the spectral resolution is achieved by electron detection and the temporal resolution by a variable phase delay, this technique does not require scanning the pump frequency and the entanglement times, which significantly simplifies the experimental setup, making it feasible with current instrumentation. Application is made to the photodissociation dynamics of pyrrole calculated by exact nonadiabatic wave packet simulations in a reduced two nuclear coordinate space. This study demonstrates the unique advantages of ultrafast quantum light spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessing the design of integrated methane sensing networks

Abstract While methane is the second largest contributor to global warming after carbon dioxide, it has a larger warming effect over a much shorter lifetime. Despite accelerated technological efforts to radically reduce global carbon dioxide emissions, rapid reductions in methane emissions are needed to limit near-term warming. Being primarily emitted as a byproduct from agricultural activities and energy extraction, methane is currently monitored via bottom–up (i.e. activity level) or top–down (via airborne or satellite retrievals) approaches. However, significant methane leaks remain undetected and emission rates are challenging to characterize with current monitoring frameworks. In this paper, we study the design of a layered monitoring approach that combines bottom–up and top–down approaches as an integrated sensing network. By recognizing that varying meteorological conditions and emission rates impact the efficacy of bottom–up monitoring, we develop a probabilistic approach to optimal sensor placement in its bottom–up network. Subsequently, we derive an inverse Bayesian framework to quantify the improvement that a design-optimized integrated framework has on emission-rate quantifications and their uncertainties. We find that under realistic meteorological conditions, the overall error in estimating the true emission rates is approximately 1.3 times higher, with their uncertainties being approximately 2.4 times higher, when using a randomized network over an optimized network, highlighting the importance of optimizing the design of integrated methane sensing networks. Further, we find that optimized networks can improve scenario coverage fractions by more than a factor of 2 over experimentally-studied networks, and identify a budget threshold beyond which the rate of optimized-network coverage improvement exhibits diminishing returns, suggesting that strategic sensor placement is also crucial for maximizing network efficiency.

54 ENVIRONMENTAL SCIENCES↗

UV-Fluorescence Imaging of Silicon PV Modules After Outdoor Aging and Accelerated Stress Testing

Fast, non-destructive, outdoor-compatible methods for photovoltaic module characterization are essential for monitoring module quality without disrupting energy production. UV-fluorescence (UVF) imaging of the encapsulant layer can be used for crack detection in the field. We show that UVF patterns vary widely between modules and types of applied stress. We propose that combining accelerated stress testing (e.g. thermal cycling and damp heat) with field investigations can help build understanding of different types of UVF, which are formed and subsequently quenched at varying rates. Ultimately, such understanding could enable estimating when cracks were formed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Toward “super-scintillation” with nanomaterials and nanophotonics

Abstract Following the discovery of X-rays, scintillators are commonly used as high-energy radiation sensors in diagnostic medical imaging, high-energy physics, astrophysics, environmental radiation monitoring, and security inspections. Conventional scintillators face intrinsic limitations including a low extraction efficiency of scintillated light and a low emission rate, leading to efficiencies that are less than 10 % for commercial scintillators. Overcoming these limitations will require new materials including scintillating nanomaterials (“nanoscintillators”), as well as new photonic approaches that increase the efficiency of the scintillation process, increase the emission rate of materials, and control the directivity of the scintillated light. In this perspective, we describe emerging nanoscintillating materials and three nanophotonic platforms: (i) plasmonic nanoresonators, (ii) photonic crystals, and (iii) high-Q metasurfaces that could enable high performance scintillators. We further discuss how a combination of nanoscintillators and photonic structures can yield a “super scintillator” enabling ultimate spatio-temporal resolution while enabling a significant boost in the extracted scintillation emission.

Carr Delgado, Hamish↗

Demonstration of Novel Monitoring Techniques for a North Dakota Carbon Capture and Storage Project

Conference paper presented at 16th International Conference on Greenhouse Gas Control Technologies (GHGT-16), Lyon, France, October 23–27, 2022. We present an overview and initial results of the novel and sustainable monitoring techniques developed by the Energy & Environmental Research Center (EERC) and its commercial partners associated with the Red Trail Energy (RTE) carbon capture and storage (CCS) project. RTE is an investor-owned 64-million-gallon dry mill ethanol production plant in Richardton, North Dakota, USA. Currently in operation as of June 2022, the RTE facility will capture 180,000 tonnes of carbon dioxide (CO 2 ) annually (>99% CO 2 ) that is otherwise emitted during the ethanol production process and inject it into the Broom Creek Formation, a deep saline aquifer, for permanent on-site geologic storage.

01 COAL, LIGNITE, AND PEAT↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Embedded High-Temperature Sensors: Enhancing Thermoelectrical Performance with Refractory Composites Gradient Layers

To monitor the stability of various energy and manufacturing systems, sensors capable of operating at temperatures exceeding 1000 °C in diverse environments for extended durations are essential. However, under harsh conditions, degradation of sensing materials is a concern that can be controlled by embedding the sensors into refractory oxides. Doped-LaCrO3 based composites are excellent candidates for high-temperature sensing applications due to their good thermoelectrical properties. However, chemical reactivity between the conductive phase and the refractory oxides can decrease the performance of the sensors. In this work, it was devised gradient-type protective layers safeguarding conductive phases within embedded thermocouples, which were fabricated and characterized by X-Ray Diffraction for phase development analysis, Scanning Electron Microscopy and Energy-dispersive X-ray spectroscopy for microstructure and cationic interdiffusion kinetics, long-term thermoelectric testing was completed up to 1400 °C. The enhanced performance of these novel sensors addresses a critical limitation, rendering them viable for long-term high-temperature applications.

20 FOSSIL-FUELED POWER PLANTS↗

TLS characterization using multilevel decay of a fixed-frequency transmon

Transmon qubits are a cornerstone of superconducting quantum computing platforms, yet their coherence times often exhibit temporal fluctuations that degrade processor performance. These variations are commonly attributed to shifts in the resonance frequencies of individual two-level systems (TLSs) near the qubit transition. In this study, we monitor the lifetimes of multiple energy levels of a fixed-frequency transmon and examine their temporal correlations. Our measurements reveal that one or more TLSs—detuned by more than 100 MHz from the qubit transition—can still significantly influence coherence. The proposed method provides a powerful tool for TLS spectroscopy without the need to tune the transmon frequency, either via a flux-tunable inductor or AC-Stark shifts.

Roy, Tanay [Fermilab] (ORCID:000000019442862X)↗

TLS characterization using multilevel decay of a fixed-frequency transmon

Transmon qubits are a cornerstone of superconducting quantum computing platforms, yet their coherence times often exhibit temporal fluctuations that degrade processor performance. These variations are commonly attributed to shifts in the resonance frequencies of individual two-level systems (TLSs) near the qubit transition. In this study, we monitor the lifetimes of multiple energy levels of a fixed-frequency transmon and examine their temporal correlations. Our measurements reveal that one or more TLSs—detuned by more than 100 MHz from the qubit transition—can still significantly influence coherence. The proposed method provides a powerful tool for TLS spectroscopy without the need to tune the transmon frequency, either via a flux-tunable inductor or AC-Stark shifts.

Roy, Tanay [Fermilab] (ORCID:000000019442862X)↗

Synthesis and Ultrahigh Pressure Compression of High-Entropy Boride (Hf0.2Mo0.2Nb0.2Ta0.2Zr0.2)B2 to 220 GPa

The high-entropy boride (Hf0.2Mo0.2Nb0.2Ta0.2Zr0.2)B2 material was synthesized under high-pressures and high-temperatures in a large-volume Paris-Edinburgh (PE) press from a ball-milled powder mix of HfO2, MoO3, Nb2O5, Ta2O5, ZrO2, carbon black, and boron carbide. The transformation process was monitored in situ by energy-dispersive x-ray diffraction with conversion starting at 1100 °C and completed by 2000 °C with the formation of a single hexagonal AlB2-type phase. The synthesized sample was recovered, powdered, and mixed with platinum pressure marker and studied under high pressure by angle-dispersive x-ray diffraction in a diamond anvil cell. The hexagonal AlB2-type phase of (Hf0.2Mo0.2Nb0.2Ta0.2Zr0.2)B2 was found to be stable up to the highest pressure of 220 GPa reached in this study (volume compression V/V0 = 0.70). The third order Birch-Murnaghan equation of state fit to the high-pressure data up to 220 GPa results in an ambient pressure unit cell volume V0=28.16±0.04 Å3, bulk modulusKo = 407 ± 6 GPa, pressure derivative of bulk-modulus K0′ = 2.73 ± 0.045 GPa. Our study indicates that this high-entropy boride (Hf0.2Mo0.2Nb0.2Ta0.2Zr0.2)B2 material is stable to ultrahigh pressures and temperatures and exhibit high bulk modulus similar to other incompressible transition metal borides like ReB2 and Os2B3.

36 MATERIALS SCIENCE↗